Tender For Electrical Rewiring Of Pwd Colony Type-Iv/B Residence In District Badaun - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 2 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 3 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 4 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular swifch, connections etc. as required. 5 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required for AC/Power 6 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door 7 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door 8 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door 9 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole 10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole 11 S/F of63 A4 pole MCB(10KA)C curve. Cat A 12 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 13 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. 14 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as requiredfor inverter Wiring:-1x1.5 mm 15 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 16 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 17 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire 18 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire 19 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 10 sq. mm + 1 X 6 sq. mm earth wire 20 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 16 sq. mm + 1 X 6 sq. mm earth wire 21 S/L of 16 sqmm3.5 coreAl conductor pvc insulated armoured served sheathed cable 1100 V grade. Complete in all respect. 22 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 Ampere 23 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 24 Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing as required. 25 S/Fof Call Bell fixed etc.complete in all respect. 26 S/F of LED tube light batten Fitting suitable for upto 1X22watt LED tube light on surface.complete in all respect. 27 S/F of LED Bulb 15 watt P.W.D.Approved 28 S/F of 3w to 6w LED Decorative Mirror Lightfitting 29 S/F of Water tight oblong 10wLED Bulk Head luminaire havingDie cast Alluminium housingwithdriver set confirming to IP 65 and above protection ,suitable for 24 Hrs. CAT AAA 30 S/Fof Singlelight wall bracket fixedon matching M.D.F.E.G. Board baseetc. Upto 6 Watt 31 S/Fof Doublelight wall bracket fixedon matching M.D.F.E.G. Board baseetc. 32 S/F of 75w to90W LED Street Light Fitting havingdie cast Al body and diffuser,driver set. Complete in all respects. Cat AAA 33 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 34 S/O Ceilling Fan 1200mm sweep size as per P.W.D. Approved make 35 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 36 Supply and Installation of Fresh Air Fan 300 mm/900 rpm 37 Supply and Installation of Heavy duty Exhaust Fan 300 mm/1400 rpm 38 E & T of exhaust fan/Fresh air fan 39 L/C of dismentling old wiring