Tender For Tourism Development Of Kabir Dhuni/Gorakh Talaiya At Sahjanwa Distt. Gorakhpur - Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 3 Filling of carted earth. 4 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 5 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 6 Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. 7 (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 8 (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturers standard dilution) 9 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN LINTEL] 10 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN BEAM] 11 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN SLAB] 12 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN COLUMN] 13 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN FOOTING] 14 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 15 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 16 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 17 Same as in item No. 11 abovebutin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) 18 Ground Floor 19 First Floor 20 Same as in item no. 14 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 21 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars 22 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. 23 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand 24 Ground Floor 25 First Floor 26 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 finesand. 27 Ground Floor 28 First Floor 29 Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required. 30 Supply & fixing 6mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supply of all materials, labour and Tool & plants. 31 Supply & fixing 6mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supply of all materials, labour and Tool & plants. 32 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mm (Flooring) 33 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mm (Skirting) 34 Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm [IN FLOORING] 35 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment 36 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 37 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 38 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood 39 Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable doublenylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. 40 Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares anddrainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 41 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) 42 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) 43 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 44 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (Ceiling) 45 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 46 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. 47 Providing & fixingAluminiumsliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm. 48 Providing and fixingAluminium. anodised towerbolts (barrel type) with necessary screws etc. complete. 49 (a) 250 mm x 10mm 50 Providing and fixing S.S anodised handles with screws etc. complete (a) 125 mm. 51 Providing & laying brick coba 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30cm x cm and side wall parapet shall be mono tythic plaster wall upto 30 cm higher and junction 52 and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acelic water proofing compound @ 2% by weight & including S/o all material, labour, T & P etc complete for proper completion of work. 53 Painting with synthetic enamel paint of approved brand and manufacture of required colourto give an even shade : 54 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 55 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 56 Construction of drain alongwith apron. 57 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. 58 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc.p 59 Centering and shuttering including strutting, propping etc. and removal of form for : 60 (a) Foundations, footings, bases of columns, etc. for mass concrete 61 (b) Suspended floors, roofs, landings, balconies and access platform 62 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 63 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 64 Providingandfixingtiledfalseceilingofspecifiedmaterialsofsize 595x595mmintruehorizontallevel,suspendedoninterlockingmetalgrid ofhotdippedgalvanizedsteelsections(galvanized@120grams/sqm, bothsideinclusive)consistingofmain“T”runnerwithsuitablyspaced jointstogetrequiredlengthandofsize24x38mm madefrom0.30mm thick(minimum)sheet,spacedat1200mmcentertocenterandcross “T”ofsize24x25mmmadeof0.30mmthick(minimum)sheet,1200 mmlongspacedbetweenmain“T”at600mmcentertocentertoform agridof1200x600mmandsecondarycross“T”oflength600mmand size24x25mmmadeof0.30mmthick(minimum)sheettobeinterlocked atmiddleofthe1200x600mmpaneltoformgridsof600x600mmand wallangleofsize24x24x0.3mmand layingfalseceilingtilesofapproved textureinthegridincluding,requiredcutting/making, openingforservices likediffusers,grills,lightfittings,fixtures,smokedetectorsetc. 65 Main“T” runnerstobesuspendedfromceilingusingGIslottedcleatsofsize27x 37x25x1.6mmfixedtoceilingwith12.5mmdiaand50mmlongdash fasteners,4mmGIadjustablerodswithgalvanisedbutterflylevelclipsof size85x30x0.8mmspacedat1200mmcentertocenteralongmainT, bottomexposedwidthof24mmofallT-sectionsshallbepre-paintedwith polyesterpaint,allcompleteforallheightsasperspecifications,drawings andasdirectedbyEngineer-in-charge. 66 12.5mmthicksquareedgePVCLaminatedGypsum Tileofsize595x595mm,madeofGypsumplasterboard, manufacturedfromnaturalgypsumasperIS2095part|and laminatedwithwhite0.16mmthickfireretardantPVCfilm onthefacesideand12micronmetalizedpolyesteronthe backsidewithalledgessealedwiththefacesidePVCfilm whichgoesaroundandwrapstheedgesandisbondedto theedgesandthebacksidemetalizedpolyesterfilmsoasto makethetileacompletelysealedunit. 67 Internal Electrification (Yatri Hall) 68 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 69 Group C 70 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 71 Submains : 72 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 73 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 74 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 75 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 76 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 77 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 78 20 mm 79 25 mm 80 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 81 5/6 A switch 82 3 pin 5/6 A socket outlet 83 TV antenna socket outlet 84 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 85 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 86 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 87 1 or 2 Module (75mmX75mm) 88 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 89 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 90 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 91 Upto 450 mm sweep 92 MCBs & DB’s : 93 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 94 4 way (4 + 12), Double door 95 6 way (4 + 18), Double door 96 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 97 4 way (4 + 12), Double door 98 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 99 Single pole 100 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 101 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 102 100 A,30KA,FPMCCB 103 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 104 Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A 105 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 106 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 107 ELCB/RCCB Switches : 108 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 109 40 A 110 63 A 111 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 112 Earthing Work : 113 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 114 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 115 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 116 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 117 100 mm width X 50 mm depth X 1.6 mm thickness 118 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 119 Lighting Fixtures (Lights/Fans) : 120 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 121 Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect . 122 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 123 Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter complete in all respect. 124 Armoured Cables (Cable/Gland/Lug) : 125 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 126 size 25 sq mm x 3-1/2core 127 size 35 sq mm x 3-1/2core 128 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable 129 size 25 sq mm x 3-1/2core 130 size 35 sq mm x 3-1/2core 131 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 132 size 25 sq mm 133 size 35 sq mm 134 L.T. Switch Panel Board : 135 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. 136 The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. 137 The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type 138 Incoming - 139 200 Amp MCCB-1 No. 140 Outgoing - 141 100 Amp 4P MCCB - 2 Nos. (for VTPN D.B. DBs) 142 100 Amp 4P MCCB - 2 Nos. (for VTPN D.B. DBs) 143 63 Amp 4P MCCB - 1 Nos. (for Terrace pump)) 144 40 Amp DP MCB - 2 Nos. (Spare) 145 (or As per requirment directed by Project Manager.) 146 Non-Schedule Items 147 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 148 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 149 INTERNAL SANITARY (Yatri Hall) 150 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required 151 W.C. pan with ISI marked white plastic seat and lid 152 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 153 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. 154 Providing and fixing wash basin with C.I. brackets, 15 mm dia C.P. brass Single Hole Basin Mixture approved quality and make ,including painting of fittings and brackets, cutting and making good the walls wherever require. 155 a)White Vitreous China wash basin size 550x 400 mm with 15 mm dia C.P. brass Single Hole Basin Mixture. 156 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 157 Semi rigid pipe 158 a) 32mm dia 159 b) 40mm dia 160 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 161 Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 162 15mm nominal bore 163 Providing and fixing CP Brass 32 mm sizeBottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. 164 Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. 165 a) 15mm dia nominal dia. 166 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 167 a) 100 mm diameter 168 Providing and fixing Toilet paper holder 169 a) C.P. brass 170 Providing & fixing 600x120x5 mm glass self with edges round off, supported on anodiesd aluminium angle framewith C.P. brass bracket and guard rail complete fixed with 40 mmlong screws, rawl plugs etc, complete. 171 Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. 172 Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. 173 Providing & fixing 32 # G.I. Pipes spout including cutting & making good the walls etc. 174 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 175 110mm diameter 176 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 177 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 178 110mm 179 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 180 Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. 181 (internal work) 182 Exposed on wall 183 32mm dia nominal bore 184 Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 185 32mm dia nominal bore. 186 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 187 internal work -Exposed on wall 188 20mm dia nominal outer dia pipes 189 25mm dia nominal outer dia pipes 190 32mm dia nominal outer dia pipes 191 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. 192 Concealed work including cutting chases and making good the walls etc. 193 15mm dia nominal outer dia pipes 194 20mm dia nominal outer dia pipes 195 25mm dia nominal outer dia pipes 196 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 197 15mm nominal bore 198 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 199 15mm nominal bore 200 Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 201 Providing and fixing gun metal gate valve with wheel of approved quality. 202 25mm dia nominal bore 203 20 mm dia nominal bore 204 32mm dia nominal bore 205 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 206 25 mm nominal bore 207 Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 208 Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, 209 in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. 210 Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. 211 Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 212 100mm diameter 213 150mm diameter 214 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 215 100mm diameterS.W. Pipe 216 150mm diameterS.W. Pipe 217 Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 218 150 x 100 mm. size P type 219 With Sewer bricks conforming to IS : 4885 220 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design 221 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). 222 With FPS bricks of class designation 75 223 (i) For Sewer Line 224 Extra for depth of man hole size 90x80 cm 225 Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. 226 Extra for depth of man hole size 90x120 cm 227 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design 228 With 20x20 mm square bar 229 EXTERNAL WATER SUPPLY SYSTEM 230 Provding and fixing gun metal non return valve of approved quality (screwed end) 231 50 mm nominal bore 232 Vertical 233 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. 234 External work 235 32mm nominal bore. 236 50mm nominal bore. 237 Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. 238 32 mm diameter pipe 239 50 mm diameter pipe 240 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 241 32 mm nominal bore 242 50 mm nominal bore 243 Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 244 With F.P.S. bricks 245 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 246 25 to 40 mm dia nominal bore 247 50 to 80 mm dia nominal bore 248 Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 249 90 mm O.D. 250 110 mm O.D. 251 Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. 252 Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. 253 Size 90 mm 254 Size 110 mm 255 Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. 256 Size 75/90 mm 257 Size 110 mm 258 Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. 259 Size 90x90x90 mm 260 Size 110x110x110 mm 261 Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. 262 Size 90 mm 263 Size 110 mm 264 FIRE FIGHTING 265 (A) Supplying, Installation, Testing & Commissioning ofElectric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required:(Terrace Pump) 266 (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520. 267 (C) Suitable HP Squirrel cage indution motor, TEFC type suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, confirming to IS-325. 268 (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. 269 (E) Suitable cement concrete foundation duly plastered with anti vibration pads. 270 450 lpm at 35 m head 271 Providing, laying, testing & Commissioning ofC class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 272 25 mm dia 273 100 mm dia 274 Supplying & fixing single headed internal yard hydrant valve with instantaneousGunmetal/Stainless Steel coupling of63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: 275 Single headed Gunmetal 276 Supplying, fixing, testing & commission of butterfly valve ofPN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 277 100 mm dia 278 Supplying & fixing orifice plate made out of 6 mm thick stainless steel(grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required: 279 Providing, installation, testing and commission of non-return valve offollowing sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 280 100 mm dia 281 Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: 282 Gun Metal 283 Supplying & fixing First-aid hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. 284 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 285 20 mm nominal internal dia gun metal globe valve & nozzle. 286 Drum and brackets for fixing the equipments on wall. 287 Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 288 30 m 289 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. 290 Gun Metal 291 Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 292 Providing & fixing of pressure switch in M.S. pipe line including connection etc as required. 293 Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 294 FIRE DETECTION & ALARM SYSTEM 295 Supplying, installation, testing & commissioning of Manual call Boxes of MS constuction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 296 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box(16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required. 297 Supplying & laying of 2X1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 298 Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 299 25mm 300 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilityes as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 301 4 Zone 302 Providing, laying, testing & Commissioning ofC class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 303 80 mm dia 304 100 mm dia 305 Supplying & fixing single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: 306 Single headed Gunmetal 307 Supplying, fixing, testing & commission of butterfly valve ofPN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 308 80 mm dia 309 100 mm dia 310 Providing, installation, testing and commission of non-return valve offollowing sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 311 100 mm dia 312 Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: 313 Gun Metal 314 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. 315 Gun Metal 316 Supplying & fixing ofFire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required. for suitable dia MS pipe connection conforming to IS 904 as required: 317 2 way-100 mm dia M.S. Pipe 318 Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 319 Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 320 Providing/Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted “FIRE” in red luminous paint. The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete.Make : Standard/Lifeguard or EQ. 321 Supplying and fixing of Fire man axe.Make :- Agni Suraksha (ASES) or EQ 322 Supply, Installation, Testing and Commissioning of electronic siren with suitable audible range of 1 k.m. approximately 4 watt.complete in all respects. Make :- Agni Suraksha (ASES) or EQ. 323 Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprisingof :a) 40 amp 3 Pole MCCB, 50Hz with breaking capacity 10KW.b)One Volt meter (0-500 V) with selector switch.c) One set including lamps.Make :- Make :- Agni Suraksha (ASES)/ABB/L&T or EQ. 324 SEPTIC TANK & SOAK PIT 325 Size :- Length = 5.00 M. Width = 2.00M Total Depth =3.00M 326 Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. 327 In all kind of soil upto 1.5m depth 328 In all kind of soil upto 1.5m to 3.0m. depth 329 In all kind of soil upto 3.0m to 4.5m. depth 330 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 20mm nominal size) 331 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 332 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) including centering and shuttering and reinforcement. 333 TMT Fe-500 in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 334 15mm cement plaster on rough side of mix 1:4 (1 cement : 4 coarse sand) 335 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 336 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 337 Providing & fixing 75mm dia vent pipes. 338 Providing & fixing of 75mm dia cast iron terminal guard. 339 M.D. -10- Circular shape 500mm internal diameter 340 M.D. -2.5- Circular shape 450mm internal diameter 341 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. 342 With F.P.S. bricks 343 Centering and shuttering including strutting, propping etc. and removal. 344 UPGRADATION OF BOUNDRY WALL (519.20 RM) 345 R.C.C. work in Beam 346 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 347 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 348 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick workbending for proper shap as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured. 349 M-150 Brick work in Super Structure in 1:6 cement and coarse sand mortar necessary cutting & moulding of brick as required thickness of walls not to be less than 1-1/2 brick. including supply of all materiallabour, Tools & Plants etc.required for proper completion of the work 350 12 mm cement plasterinsingle coat on fair sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth.(1)1 cement:6 fine sand 1.25 F.M. 351 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm 352 Steel reinforcement for R.C.C. work ready to use “cut and bend” rebars of approved make fromfactory/workshop to construction site includin placing in position and binding all complete above plinth level. 5.22C.1 Thermo-Mechanically Treated bars of grade Fe-500D or more. 353 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 354 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 355 Centering and shuttering including strutting, propping etc. and removal of form for 356 Lintels, beams, plinth beams, girders, bressumers andcantilevers 357 Centering and shuttering including strutting, propping etc. and removal of form for 358 Column 359 COST OF SIGNAGE /INTERPATION WALL about theme of Kabir das gurunanak ravidas & Guru Gorakhsh Nath & Sant Keshavdas (CIVIL WORK) (07 Nos) 360 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 361 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone ballast 40 mm nominal size) and curing complete,including cost of form- work, in foundation. 362 R.C.C. (M-20) work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. 363 As in item 3 abovebut inR.C.C.beamwithapproved stone ballast.(Using1:1.5:3Mix concrete) 364 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in footing excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.(M-20) 365 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in columns excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.(M-20) 366 P/F TMT Bar -Fe 500 in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 367 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 368 Red sand stone - Exposed face machine cut and table rubbed with rough backing. 40 mm thick 369 Centering and shuttering including strutting, propping etc. and removal of form for : 370 (a) Foundations, footings, bases of columns, etc. for mass concrete 371 (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers 372 (c) Columns, Pillars, Piers, Abutments, Posts and Struts 373 INTERLOCKING PAVER front side parking (971.50 sqm) 374 Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. (DSR 2.8.1) 375 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 376 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 377 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge. 378 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern 379 SAND STONE PATHWAY (arround kund & green area) 1631 SQM) 380 Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. (DSR 2.8.1) 381 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 382 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 383 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone 384 HORTICULTURE AND LANDSCAPING 385 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 386 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 387 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). 388 Supplying and stacking well decomposed cow dung manure at site including royalty and carriage upto site (cow dung measured in stacked will be reduced by 8% for payment.) 389 Anti termite treatment of lawn area through premise 30.50% I P. one literpremise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. 390 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 391 GRASS PLANTING WORK 392 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge 393 GROUND COVER/ PLANTING WORKS 394 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) 395 SHRUB PLANTING WORKS 396 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) 397 Holes 60 cm dia, and 60 cm deep 398 Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge. 399 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35- 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 400 Providing and stacking of Ficus blackii (F.vivion) of height 45-60 cm. with 6- 8 branches healthy foliage in earthen pots of size 25 cm as per direction of the officer-in-charge. 401 Providing and Displaying Ficus black vivion piller Topiary (sylinder type) well developed with fresh & healthy 180 to 210 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge. 402 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 403 Providing and Displaying Bamboo Buddha Valley with fresh & healthy 5 to 6 suckers 1.80 m to 2.10m ht umbrella type well developed in 50 cm Cement Pot as per direction of the officer-in-charge. 404 Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge. 405 Providing and stacking of Polyalthia pendula (Ashok Pendula) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 406 External water suplly from submersiblepump (85 RM) (Detail As per TS Estimate) 407 GAZIBO (2 Nos) 408 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 409 Filling of Carted earth 410 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. 411 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 412 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground 413 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 414 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 415 R.C.C. work in slab 416 R.C.C.work in beams 417 R.C.C.work in footing foundation 418 R.C.C.work in Column 419 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 420 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 421 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 422 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 423 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 424 15 mm cement plaster on rough side of single or half brick wall of mix: 425 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 426 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 427 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 428 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 429 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 430 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,V epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 431 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 432 Centering and shuttering including strutting, propping etc. and removal of form for : 433 (a) Foundations, footings, bases of columns, etc. for mass concrete 434 (b) Suspended floors, roofs, landings, balconies and access platform 435 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 436 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 437 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 438 Red sand stone - Exposed face machine cut and table rubbed with rough backing 439 ELECTRICAL WORK 440 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 441 Group C 442 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 443 Submains : 444 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 445 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 446 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 447 20 mm 448 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 449 5/6 A switch 450 3 pin 5/6 A socket outlet 451 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 452 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 453 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 454 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 455 MCBs & DB’s : 456 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 457 4 way (4 + 12), Double door 458 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 459 Single pole 460 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 461 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 462 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 463 ELCB/RCCB Switches : 464 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 465 40 A 466 Earthing Work : 467 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 468 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 469 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 470 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 471 Non-Schedule Items 472 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 473 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 474 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 475 PLUMBING WORK 476 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 477 110 mm 478 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 479 110 mm 480 [GAZIBO ] EXTRA HEIGHT (02 Nos) 481 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 482 Filling of Carted earth 483 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. 484 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 485 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground 486 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 487 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 488 R.C.C. work in slab 489 R.C.C.work in beams 490 R.C.C.work in footing foundation 491 R.C.C.work in Column 492 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 493 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 494 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 495 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 496 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 497 15 mm cement plaster on rough side of single or half brick wall of mix: 498 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 499 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 500 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 501 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 502 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 503 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,V epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 504 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 505 Centering and shuttering including strutting, propping etc. and removal of form for : 506 (a) Foundations, footings, bases of columns, etc. for mass concrete 507 (b) Suspended floors, roofs, landings, balconies and access platform 508 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 509 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 510 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) includingpointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sides by means of cramps andpins which shall be paid for separately) : 511 Red sand stone - Exposed face machine cut and table rubbed with rough backing 512 ELECTRICAL WORK 513 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 514 Group C 515 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 516 Submains : 517 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 518 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 519 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 520 20 mm 521 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 522 5/6 A switch 523 3 pin 5/6 A socket outlet 524 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 525 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 526 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 527 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 528 MCBs & DB’s : 529 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 530 4 way (4 + 12), Double door 531 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 532 Single pole 533 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 534 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 535 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 536 ELCB/RCCB Switches : 537 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 538 40 A 539 Earthing Work : 540 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 541 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 542 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 543 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 544 Non-Schedule Items 545 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 546 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 547 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 548 PLUMBING WORK 549 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 550 110 mm 551 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 552 110 mm 553 COST OF STONE BENCHE (Supply, and fixing in position 3 seater sand Stone Benches, 1800*600*450 mm at site as per approved quality and design. including all cost of accesories, transportation etc. complete in all respect.) (Detail As per TS Estimate) 554 SOLAR LIGHTall in one Philips (Detail As per TS Estimate) 555 CONTROLLING WATER LOSSES IN GORAKH TALAIYA KUND 556 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. 557 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green.Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. 558 HDPE SHEET 1 Layer at pond bottom(800 MICRON) 559 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-III) including manufactured sand derived fromRecycled Concrete Aggregate (RCA) upto 25% : 3 graded stone aggregate 20 mm nominalsize including Recycled Concrete Aggregate (RCA) upto 25%). 560 Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 561 MINI POND & CONNECTION 562 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. 563 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 564 Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) 565 Raised and cut pointing on stone work in white cement mortar 1:3 (1 white cement : 3marble dust). 566 Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressedstones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. all complete. (Payment for Stone to be made separately). 567 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 568 400 mm dia 569 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design 570 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover108 kg and weight of frame 100 kg) : 571 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 572 (i) For PIPE Line 573 Extra for depth of man hole size 90x120 cm 574 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 575 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 576 For pipes 350 to 450 mm diameter 577 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete 578 450.mm diameter 579 Boring 580 T.W. boring of 200 mm dia with 150 mm dia P.V.C. pipe assembly, 7.50 H.P. submersible pump including supply of all accessories starter, panel etc. & pipe arrangements complete. 581 8 PVC casing pipe of ISI mark. 582 P/ F 3 GI pipe (B) class. 583 Nylon mesh for filter. 584 Plastic dori. 585 Solvent cement. 586 8 End cap. 587 8 Submersible cap. 588 3 MS clamp (Heavy). 589 3 GI elbow. 590 3 X 6 GI nipple. 591 7.5 HP 9 Stage submersible pump of ISI mark with automatic panel. 592 4.00 sqm. Submersible cable. 593 Drilling charges for16 dia tubewell. 594 Pea Gravel. 595 2 MS socket. 596 Rope with plastic coated 597 Cartage of material upto site. 598 water collection tank at ground lvl(haudi) 599 Shop 01 Nos 600 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 601 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 602 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 603 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 604 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground. 605 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 606 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 607 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 608 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 609 R.C.C. (M-20) work with cement approved coarse sand and 20 mm. guage approved stone grit in the proportion of 1:1.5:3 in Lighter Beam excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. 610 R.C.C. Work IN FOOTING 611 R.C.C. Work in column 612 M-150 brick work in one cement & 6 coarse sand 2.25 F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work. 613 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 614 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 615 M-150 Brick work in super-structure above plinth level up to floor two level (up to two storeys) includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) 616 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 617 Providing & laying brick Coba 120mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of 618 coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick 619 ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. 620 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 621 35 mm thick (Single Leaf) 622 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) both Side 623 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 624 Hold fast for chaukhats of doors/windows. 625 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a) Second class teak wood 626 TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 627 Fixing of Door, windows/ventilators chaukhats in position. 628 (a) Door 629 15 mm thick plaster with cement mortar in proportion of 1:4 (1 cement: 4 coarse sand) cement & coarse sand in plinth. 630 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25 631 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand. 2.25.F.M. 632 12 mm cement plaster in ceiling to finshed even and smooth with mix of 1 cement : 3 coarse sand. 633 Addforplasterdripcourse/grooveinplasteredsurfaceormouldingto R.C.C.projections. 634 Ground & First floor 635 40mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. 636 Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work excluding base concrete. 637 Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work excluding base concrete. 638 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 639 Granite of any colour and shade (Area of slab over 0.50 sqm) 640 Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3, Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt, dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. 641 Same as item above but on new wood surface. 642 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 643 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) 644 Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. 645 Supplying and fixing rolling SHUTTERS of approved make made 80x125mm (3x5) cold rolled M.S. lath inter locked throughout their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top cover and springs. 646 Providing and fixing ball bearing for rolling shutters. 647 Red Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 40 mm thick 648 S.S.Cramp 649 Making of draing along with apron 150 X 150 MM 650 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter 651 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermalexpansion. 110 mm bend 652 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 653 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 654 Centering and shuttering including strutting, propping etc. and removal of form for : 655 (a) Lintels, beams, plinth beams, girders, bressumers and cantilevers 656 (b) Suspended floors, roofs, landings, balconies and access platform 657 (c) Foundations, footings, bases of columns, etc. for mass concrete 658 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 659 ELECTRICAL WORK 660 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 661 Group C 662 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 663 Submains : 664 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 665 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 666 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 667 20 mm 668 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 669 5/6 A switch 670 3 pin 5/6 A socket outlet 671 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 672 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 673 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 674 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 675 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 676 Upto 450 mm sweep 677 MCBs & DB’s : 678 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 679 4 way (4 + 12), Double door 680 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 681 Single pole 682 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 683 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 684 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 685 ELCB/RCCB Switches : 686 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 687 40 A 688 Earthing Work : 689 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 690 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 691 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 692 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 693 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 694 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 695 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 696 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 697 EARTH FILLING ON SITE 698 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 699 High Mast Light 700 Supply & Installation of High Mast 12.0mtr. Long with 180 watt LED 6 No. fitting with IP 65 Protection complete in all respect.(Including Panel) 701 supply and fixing of 15 amp SPN automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors ,HRC fuse,isolating switch,metering instrument,and instrument box with CTs etc.complete in all respect. 702 Cables 703 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size 704 size 6 sq mm x 2 core 705 size 10 sq mm x 4 core 706 size 25 sq mm x 3-1/2core 707 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge.for cable 708 size 6 sq mm 709 size 10 sq mm 710 size 25 sq mm 711 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 712 size 6 sq mm 713 size 10 sq mm 714 External Painting on Existing Building 715 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 716 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on ceiling to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. (Inner walls) 717 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 718 Scraping old whit & colour wash including disposal of refuse as directed by the Engineer-in-charge with in a distance of 60m (Inner Wall) 719 SAND STONE FLOORING ON POND STEP & CHABUTRA EXTENSION & GRANIET FLOORING 720 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone 721 S.S. RAILING 722 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. 723 Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm [IN FLOORING] 724 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 725 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 726 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 727 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 728 Centering and shuttering including strutting, propping etc. and removal of form for : 729 (a) Lintels, beams, plinth beams, girders, bressumers and cantilevers 730 DRAIN 300X450 (LENTH =75+30.6 +117.7+45.7 MTR) (269 RMT) 731 Earth work in excavation 732 P.C.C. 1:4:8 733 Brick work in 1:4in foundation. 734 12 MM thick plaster (1:4) 735 C.C. flooring 736 DISMATELLING & RECONSTRUCTION OF BOUNDRY WALL TWO PANNEL FOR HYDROLIC MECH. ( 5.120 Rmt.) 737 As per Details TS Estimate 738 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 739 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 740 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick workbending for proper shap as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured. 741 M-150 Brick work in Super Structure in 1:6 cement and coarse sand mortar necessary cutting & moulding of brick as required thickness of walls not to be less than 1-1/2 brick. including supply of all materiallabour, Tools & Plants etc.required for proper completion of the work 742 12 mm cement plasterinsingle coat on fair sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth.(1)1 cement:6 fine sand 1.25 F.M. 743 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm 744 Steel reinforcement for R.C.C. work ready to use “cut and bend” rebars of approved make fromfactory/workshop to construction site includin placing in position and binding all complete above plinth level. 5.22C.1 Thermo-Mechanically Treated bars of grade Fe-500D or more. 745 As per Details TS Estimate 746 Two or more coats on new work over an under coat of suitable shade with ordinary paint ofapproved brand and manufacture 747 Centering and shuttering including strutting, propping etc. and removal of form for 748 Lintels, beams, plinth beams, girders, bressumers andcantilevers 749 Centering and shuttering including strutting, propping etc. and removal of form for 750 Column 751 Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 752 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - incharge. 753 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. cum 494.10 Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 754 WALL CUTTING 755 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 756 a) 110mm diameter 757 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing completeso as to make it leak proof. 758 KITCHEN 759 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 760 Filling of Carted earth 761 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. 762 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 763 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground 764 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 765 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 766 R.C.C. work in slab 767 R.C.C.work in beams 768 R.C.C.work in footing foundation 769 R.C.C.work in Column 770 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 771 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 772 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 773 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 774 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 775 15 mm cement plaster on rough side of single or half brick wall of mix: 776 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 777 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand 778 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 779 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) 780 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 781 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 782 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 783 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 784 Centering and shuttering including strutting, propping etc. and removal of form for : 785 (a) Foundations, footings, bases of columns, etc. for mass concrete 786 (b) Suspended floors, roofs, landings, balconies and access platform 787 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 788 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 789 Providing & laying brick coba 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30cm x cm and side wall parapet shall be mono tythic plaster wall upto 30 cm higher and junction 790 and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acelic water proofing compound @ 2% by weight & including S/o all material, labour, T & P etc complete for proper completion of work. 791 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut withthe zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 792 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut withthe zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 793 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 794 (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 795 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 796 Hold fast for chaukhats of doors/windows. 797 Door / windows & Staircase grill. 798 Angle iron chaukhats size 40x40x5 799 Z Section steel window 800 Fixing of Door, windows/ventilators chaukhats in position. 801 (a) Door 802 (b) Windows 803 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). 804 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 805 Providing & fixingAluminiumsliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm. 806 Providing and fixingAluminium. anodised towerbolts (barrel type) with necessary screws etc. complete. 807 (a)250 mm x 10mm 808 (a) 200 mm x 10mm 809 Providing and fixing S.S anodised handles with screws etc. complete (a) 125 mm. 810 Wiringforlightpoint/fanpoint/exhaustfan point/callbellpointwith1.5sq.mmFRLSPVC insulatedcopperconductorsinglecorecablein surface/recessedmediumclassPVCconduit, withmodulartypeswitch,modularplate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 811 Group C 812 Wiringforcircuit/sub-mainwiringalongwith earthwirewiththefollowingsizeofFRPVC insulatedcopperconductor,singlecorecablein surface/ recessedmediumclassPVC conduitasrequired. 813 2X1.5 sqmm + 1x1.5 sqmm earth wire 814 2X2.5 sqmm + 1x 2.5 sqmm earth wire 815 2X4.0 sqmm + 1x 4.0 sqmm earth wire 816 2X6.0 sqmm + 1x 6.0 sqmm earth wire 817 Supplyinganddrawingco-axialTVcableRG-6 graded,0.7mmsolidcopperconductorPE insulated,shieldedwithfinetinnedcopperbraid andprotectedwithPVCsheathintheexisting surface/ recessed steel/ PVC conduit asrequired. 818 Say Rs. 819 Supply and fixing of following size of PVC conduitalongwiththeaccessoriesinrecess includingpaintingincaseofsurfaceconduit,or cuttingthewallandmakinggoodthesameincase of recessed conduit as required: 820 20mm 821 Supplyingandfixingfollowingmodularswitch/ socketonthe existingmodularplate&switch boxincludingconnectionsbutexcludingmodular plate etc as required. 822 TV antenna socket outlet 823 Supply and fixing of stepped type electronic fan regulatorontheexistingmodularplateswitch boxincludingconnectionsbutexcluding modular plate etc. as required. 824 Supplying and fixing modular blanking plate on the existing modular plate & switch boxexcluding modular plate as required. 825 Supplying and fixingfollowing size/modules,GIboxalongwithmodularbase &coverplate for modular switches in recess etc as required. 826 1 or 2 module(75mm X 75 mm ) 827 SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modularsocketoutletand5/6Amodularswitch,connection etc. as required. 828 SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. 829 Supplyingandfixing3pin5Aceilingroseon the existing junction box/woodedn blockincluding connectionetc. as required. 830 Supplyingandfixingbrassbatten/angleholderincluding connectionetc. as required. 831 Instalation,testing&commissioningofwall bracket/ceilingfittingsofallsizesandshapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories includingconnection etc. as required. 832 Installation, testing and commissioning of prewired,flourescentfitting/compact fluorescent fitting of all types,completewithall accessoriesandtubesetc.directlyonceiling/ wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. 833 Installation, testing and commissioning of ceiling fan,includingwiring thedownrodsof standard length(upto30cm)with1.5sq.mmFRLSPVC insulated, copper conductor, single core cable etc. Includingprovidingandfixingphenolic laminated sheet cover on the fan box etc. asrequired. 834 Numbering of ceiling fan/ exhaust fan/fluorescent fittings as required. 835 Installationofexhaustfanintheexisting opening, including making good the damage, connections, testing, commissioning etc. as required. 836 upto 450 mm sweep. 837 Extraforfixingthelouvers/shutterscomplete with frame fro exhaust fans of all sizes. 838 Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB,`C`curveincludingconnections,paintingetc. as required. 839 Providing and fixing circular/Hexagonal cast ironorM.S.sheetboxforceilingfanclamp,of internal dia 140 mm,73mmheight,top lidof 1.5 mmthickM.S.sheetwithitstopsurfacehacked for proper bonding, top lid shall bescrewed into the cast iron/M.S. sheet box by means of 3.3 mm diaroundheadedscrewed,onelocatthe conrners.Clampshallbemade of12mmdiaM.S. bar bent to shape as per standard drawing. 840 Supply,Installation,TestingandCommissioning of1200mmsweep,BEE5starrated,ceilingfan with Brush Less Disect Current(BLDC) motor, classofinsulation:B,3nos.blades,30cmlong down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9,ServiceValue(CM/M/W)minimum6,Airdelivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than10%remoteorelectronicregulatorunitfor speedcontrolandallremainingaccessories including safety pin, nut bolts, washers, temperaturerise=75degreeC(max.),insulation resistancemorethan2megaohm,suitablefor 230V,50Hz,singlephaseACSupply,earthingetc. complete as required. 841 Supplyingandfixing following way,singlepole and neutral sheet steel, MCB distribution board, 240Vonsurface/recesscomplete with,tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthingetc. asrequired(ButwithoutMCB/ RCCB / Isolators). 842 12 way, Double door 843 Supplying and fixing 5 amps. to 32 amps. rating,240volts `Cseries, miniaturecircuit breaker (MCB)suitableforinductiveloadof following poles in theexisting MCB DB completewith connections,testingand commissioningetc.as required. 844 Single Pole 845 Double Pole 846 Supplyingandfixingsinglepole,blankingplate intheexistingMCBDBcompleteetc.asrequired. 847 EarthingwithGIearthpipe,600mmX600 mmX 6 mm thick including accessories and providingmasonaryenclosurewith coverplate having locking arrangementandwateringpipe of 2.7 metre long etc, with charcoal/cock and salt as required. 848 Supplying and Laying of 25 mm X 3 mm G.I strip at0.50metrebelowgroundasstripearth electrode, including connection / terminating withnut,bolt,spring,washeretc.asrequired.( jointing shall be done by overlapping and with 2 setsofG.I.nutbolt&springwasherspacedat50mm) 849 Supplying and Laying of 6 SWG G.I wireat 0.50 metre belowgroundlevelforconductorearth electrode, including connection / terminating with G.I. thimble etc. as required. 850 LayingofonenumberPVCinsulatedandPVC sheathed/XLPEpowercableof1.1KVgradeof following size direct in ground including excavation,sandcushioning,protectivecoveringand refilling the trench etc. as required. 851 Upto 35 sq. mm 852 Supplying&makingendterminationwithbrass compressionglandandaluminiumlugsforthe following size of PVC sheathed / XLPE aluminiumconductorcableof1.1KVgradeasrequired. 853 2 X 10 sqmm. (19mm) 854 Providing,layingandfixingfollowingdiaG.I. pipe(mediumclass)ingroundcompletewithG.I. fittings including trenching (75 cm deep) andrefilling etc as required. 855 50 mm Dia(Rate taken From Civil DSR 2021-18.12) 856 Supplyoffollowingsizeof1.1KVgrade multicore aluminium conductor PVC sheathedarmoured cable as per IS 1554. 857 10 sqmm 2 core 858 Supply & fixing of7/9 W LED BULB complete inall respect. 859 Supply and fixing of LED Tube Light with battensuitableforupto1X20wattLEDtube light complete including tube etc. on surfacecomplete in all respect. 860 Supply&fixingofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down LighterhavingPowdercoateddiecast aluminium housing with heat sink, diffuser/Reflectoranddriversetcompleteinallrespects. 861 Cat. AAA 862 Supply ofAC230/250Volts,50Hz55w1400 rpm exhaust fans including providing nuts, bolts, mountingframeandotheraccessoriesincluding connections etc. complete as required.-Make:Havells-STANDARD -Refresh Air-SPS 863 300mm sweep. 864 PLUMBING WORK (As per TS Estimate 865 DRINKING WATER BOOTH 866 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 867 Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 stone ballast 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. 868 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 869 M-150 brick work in one cement & 6 coarse sand 2.25 F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work. 870 R.C.C. work in slab (Using1:1.5:3Mix concrete) 871 As in item 5 abovebut inR.C.C.beamwithapproved stone ballast.(Using1:1.5:3Mix concrete) 872 As in item 5 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. 873 As in item 5 abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast. (Using1:1.5:3Mix concrete) 874 Class M-150 Brick work in super-structure above plinth level includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than one brick thick. (1:4 cement & coarse sand) 875 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) 876 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (Fe-500) 877 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete Granite of any colour and shade 878 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 879 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) 880 Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. 881 Providing and laying water proofing treatment in sunken portion of W.C., bathroom etc, by applying cement slurry mixed with water proofing cement compound consisting of applying :- (a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with water proofing cement compound @ 0.253 kg/Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 882 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 883 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :(15 mm dia) 884 Providing and fixing G.I. Union in G.I. pipeincluding cutting and threading the pipe and making long screws etc. complete (New work) :(15 mm dia) 885 Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc.(25 mm dia) 886 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 887 Supply of 110 mm dia PVC casing pipe for boring 6 kg/sqm ISI approved. 888 WATER TANK 889 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust)with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 890 Red Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 40 mm thick 891 Centering and shuttering including strutting, propping etc. and removal of form for : 892 (a) Foundations, footings, bases of columns, etc. for mass concrete 893 (b) Suspended floors, roofs, landings, balconies and access platform 894 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 895 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 896 GST Extra As per Applicable