}

Tender For Yearly E.I. Maintenance Of Durgapur Sub-Division Hospital, (Residential And Nonresidential) Including Security Lighting System.Paschim Bardhaman..Some Supply Materials To Use Through Out The Year., durgapur-West Bengal

Public Works Department has published Tender For Yearly E.I. Maintenance Of Durgapur Sub-Division Hospital, (Residential And Nonresidential) Including Security Lighting System.Paschim Bardhaman..Some Supply Materials To Use Through Out The Year.. Submission Date for this Tender is 17-03-2025. Electrical Maintenance Tenders in durgapur West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

47985108
Tender For Yearly E.I. Maintenance Of Durgapur Sub-Division Hospital, (Residential And Nonresidential) Including Security Lighting System.Paschim Bardhaman..Some Supply Materials To Use Through Out The Year.
Open Tender
Indian
West Bengal
Durgapur
17-03-2025

Tender Documents

Tender Details

Tender For Yearly E.I. Maintenance Of Durgapur Sub-Division Hospital, (Residential And Nonresidential) Including Security Lighting System.Paschim Bardhaman..Some Supply Materials To Use Through Out The Year.- 1 Supplying and fixing 240 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.6-32 A SP MCB (Make-Legrand/Siemens/Schneider).a) 6A 2 b)10A 3 c)16A 4 d) 20A 5 e)32A DP 6 f) 40A DP 7 g) 40A FP 8 h)63A FP 9 Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make-Legrand/Siemens/Schneider).a)32A FP 10 b)40A FP 11 c)63A FP 12 d)100A FP 13 e) 32A DP 14 f) 40A DP 15 Supply & Fixing of 250v A.C Capacitor,a)2.50 mfd (tibcon steel body) 16 b)2.25 mfd (tibcon steel body) 17 S/F Single LED Tube Light fittingswith 18/20 watt Mas LED Tube.(Phillips- TMC 502 1xT-LED 22W ,Mas LEDTube 1200mm 18W 865 T8 I – 2100lm/havells/Orient) 18 Supply & Fixing of 230V 1200mm sweep ceiling fan (28Watt or less BLDC fan, class of insulation -B, SERVICE VALUE (CMM/W minimum 6.85, R.P.M. 350(min), THD <10%, supplied with remote control or wall mounted speed regulator, P.F. not less than 0.9, bult in 2.5KV SPD with complete accessories[Make: Usha Technix BLDC, Crompton, Bajaj, Atomberg, Havells, Orients, CG, RR or equivalent ](4 years warrenty) 19 Supply& Delivery of 1.5 Ton Split type room air conditioner machine (1:1) with rotary compressor and having 2/3 star (2021) rating as per BEEor as per model mention below with R-32/410A refrigarent and cordless LCD remote including refrigarant copper pipe line and connecting copper wire. Spcification - A)Cooling capacity nominal (BTU):18000BTUB) Star - 3 StarC) Rated Voltage -230v +/- 5%.D) Compressor Type - Rotaryas supplied with AC machine as per direction of EIC (MAKE-HITACHI/OGeneral-ASGA18BUTA-B (R32) /Daikin/Mitsubishi Electric)PCB Board of Indoor unit should be placed with in the metal Box. 20 Supply& Delivery of 2/1.8 Ton Split type room air conditioner machine (1:1) with rotary compressor and having 2/3 star (2021) rating as per BEEor as per model mention below with R-32/410A refrigarent and cordless LCD remote including refrigarant copper pipe line and connecting copper wire. Spcification : A)Cooling capacity nominal (BTU):24000.B) Star - 2/3 StarC) Rated Voltage -230v +/- 5%.D) Compressor Type - Rotary as supplied with AC machine as per direction of EIC (MAKE-HITACHI/OGeneral-ASGA24BUTA-B (R32) /Daikin/Mitsubishi Electric)PCB Board of Indoor unit should be placed with in the metal Box. 21 Installation of 1.5/1.8/2.0Ton capacity split type Air conditioner machine with S& F MS base plate, flastner,gutka,screws etc. nuts, bots & washers for outdoor unit as per direction of EIC.(Analysis Enclosed) 22 S/F 4 core 2.5sqmm PVCcu cable for connection between indoor & outdoor units. (polycab/kei/Gloster) 23 S/F 3 core 4sqmm PVC cu cable for connection between indoor & outdoor units. (polycab/kei/Gloster) 24 S& F of extra cooling cooper tube and cubee foam from inner unit to outer unit(condensing unit)A) 5/8 dia copper tube(ISI mark heavy gauge)with insulation with cubee foam and necy taping arrangement as per direction of EIC 25 B) 1/4 dia copper tube(ISI mark heavy gauge)with insulation with cubee foam and necy taping arrangement as per direction of EIC 26 Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator& necy.Connections(Make-Legrand/Anchor/Havels). 27 Supply & Fixing PVC drain pipe medium type(Make:Supreme/Astral) 28 Dismantling existing damaged & unservicecable electrical installation with owns tools & takles incl. Mending good damages as per GS and clearing/removing from the site. 29 Supply Wall mounted FanCrompton 450 mm WM SSTORM 2(3 blade Metal body. 30 Supply & installtion of 240V, Single phase, 5-30A digital energy meter (IEC Standereds) fixing on HW wooden board on wall with suitable fixing arrangement. (Make: L&T/HPL) 31 Supply & Fixing Bobin Insusator for ceiling Fans. 32 S&D of 1x1 sqmm pvc insulated Cu. Wire (make:finolex/polycab/Havells)(For ceiling rows to fan motor) 33 S&D of 1x0.5 sqmm pvc insulated Cu. Wire (make:finolex/polycab/Havells)(For ceiling rows to fan Tube light) 34 Supply & Fixing Split pin for ceiling Fans. 35 S&D of 5A, 3 pin Socket (piano key type) (Make- Anchor/Schindler/Havells) 36 S&D of 5/15A, 3 pin Socket (piano key type) (Make- Anchor/Schindler/Havells) 37 S&D of 5A piano key type switch (Make- Anchor/Schindler/Havells) 38 S& D Brass Screws 2 inch for switch board fixing etc. 39 S& D Gypsum Screws 1/2 inch for switch board fixing etc. 40 S& D Wooden SS Screws 2 inch for switch board fixing etc. 41 Supply only Single LED Tube Light 20WCrompton ULTRON Cat No-LTB-20-865-(2) LED Polycarbonate T8 tube with in built driver and metal heat sink. (Phillips/havells/Crompton) 42 SITC of 1000VA 230V online UPS to provide back up of 30 to 45mins having following specifications A)Nominal Input Voltage : 230V,Input Freq: 40-70Hz, Input Connections: Hard wire 3wire. Input voltage range for main operations: 160-285V B) Output Power Capacity : 0.8 kWatts/1.0KVA Nominal Output Voltage : 230V. O/P Voltage Distortion : Less than 5% Topology : Double Conversion Online Wave form type : Sine Wave Bypass : Build in Static Bypass.Back up time : 30 to 45mins on 100% load. Warranty : 2 Years on site warranty.(1 No.) 43 Supply & Delivery of 12V 150AH battery with Suitable size iron frame battery rack to fit all the batteries & also making connections with all the interlink cables. ( 1 Nos of battery racks.) 44 Charges for modification of some electrical wirings, Changing of some of the BDBs, PDBs to provide suitable electrical connection for smooth operation of above mentioned 1 Nos UPS. 45 Add GST @18% On total from item no 1 to 31. 46 Add LWC @1% On total from item no 1 to 32.

Key Value

Document Fees
Refer document
EMD
INR 32000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail