Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-03-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-03-2025 |
| 2 | 11-03-2025 | amendment | BOQ | 20-03-2025 |
| Sl. No. | Item Description |
| 1 | Taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubbing down with water etc, and removing unserviceable material outside cantt area, complete all as specified and directed.Note :- Work will be carried out upto 2nd storey of bldgs also as per pirection of Engr-in-charge including necessary formwok and scaffolding required as per site conditions & no extra payment shall be made on this account. |
| 2 | Rendering 10+5 mm thick on fair faces of brick or concrete surface walls in two layers, in cement mortar 1:4 , rendering is to be finished even and fair without using extra cement (up to 2nd storey with necessary scaffolding) complete all as specified and directed. |
| 3 | M&L Rendering cement plaster, 10 mm thick on fair faces of brick/concrete surfacesof wall in cement mortar 1:6 finished even and smooth w/o using extra cement complete all as specified and directed. |
| 4 | Rendering 5 mm thick on fair faces of brick or concrete surfaceceilings, in cement mortar 1:3 , rendering is to be finished even and smooth without using extra cementcomplete all as specified and directed. |
| 5 | Demolition of cement concrete (unreinforced) ground floor to second floors and pavings n exc 15 cm thickness (below or above ground level ) and removingthe rubbish from the work site out side defence premises complete all as specified and directed. |
| 6 | Rendering 15mm thck in CM 1:3 or Plain Cement Concrete as in sunken floorswithout extra cement on walls/floors and including mixing of water proofing compound (WPC shall be measured and paid separately), complete all as specified and directed. |
| 7 | Cleaning of dust removal to all loose existing sunken floor any material manually and with heat tark gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. Repair all joints and cracks with highly elastic bituminous cold applied putty of tarplasic having penetration after setting upto 8mm. Levelling of surface to give proper slope will be done as per site requirements with Shalipatch or euqivalent make of approved by GE cold applied.Bituminous mortar and cold emulsion cum water proofing liquid of Shalikote-T-10 or equavalent make as approved by GE, createdSSD condition on surface with water. Prime the surface with Tarfelt LM or equivalent make as approved by GE mixed with portable water in the ratio of 1:1 and apply @ 400gm per Sqm (as per surface condition). Apply first coat of Tarfelt LM or equivalent make as approved by GE having alongwith 200% conforming to ASTM-C-412 & having crack bridging of 8mm conforming to ASTM-C-836 with tensile strength after 7 days0.50mm conforming to ASTM-C-412 with no diluation water on primed surface while the surface is still tacky with consumption of 700gm /Sqm.Apply 2nd coat on cured first coat with consumption @ 700gm/Sqm in opposite direction of 1st coat by brush or roller.Allow it to dry for 10-12 hrs after apply 3rd coat with consumption @ 700gm/Sqm. Ensure final curing time of 36 hrs before allowing/carrying out any further work. Conduct ponding test after minimum 7 days applying 2 coats of U V Resistand Elastomeric Exterior Axcrylic weather resistant water proof coating of Shalicryl - 215 or eauivalent make as approved by GE having elongation of 300% after curing of 14 days conforming to ASTM D-6083, for U V protection of bituminous Elastomeric Acrylic emulsified liquid membrance of Tarfelt LM or equivalent make as approved by GE to give long life and prevent its deterioration from sunlight. Note :Application of water proofing treatment will be done by authorised applicator only. |
| 8 | M&L Cement concrete type E-2, 1:5:10 ( 40 mm graded agregate) in Sunkanfilling and mass concrete complete all as specified and directed. |
| 9 | M&L 40 mm dia G I tubing heavy grade galvanised laid over floors as a spout pipe in sunken floors complete all as specified and directed. |
| 10 | Supply only Water proofing compound liquid. |
| 11 | M&L for repairing of concrete surfaces such asbalcony, chajjas, upward or downward facias ,column, pillar, ceiling and similar items with plain cement concrete 1:2:4type B-0 including minimum reinforcement or rendering 10-15mm thickas per site requirement in CM 1:3 without using extra cement finished even and fair complete all as specified and directed (Up to second storey bldgs and including necessory formwork and scaffolding and provision of minimum reinforcement required as per site condition also taking down or dismantling as required at site), complete all as specified and directed. |
| 12 | Demolition ofreinforced cement concrete of any discription ground to 2nd floors and removingthe rubbish from the work site out side defence premises complete all as specified and directed. |
| 13 | M&L for RCC, type B-1(1:2:4), using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specifiedand directed. |
| 14 | M&Lfor TMTmildsteel bars10mm dia and over, cutto length, bentto shape required, including cranking, bendingspirallyforhooping for column, hookingendandbinding withandincludingmildsteelwire(annealed) not lessthan0.9 mm dia or securing with clips, complete all as specified and directed. |
| 15 | M&L for use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete, complete all as specified and directed. |
| 16 | M&L for use and waste form work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roof and not exc. 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar workexc. 10cm but n.exc. 20cm wide for fair finished surfaces of concrete, complete all as specified & directed |
| 17 | Demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable materialfrom the work site ouside defence premises complete all as specified and directed. |
| 18 | Brick work with subclass \"B\" bricks, old size bricks, straight or curved onplan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 19 | Brick work with subclass \"B\" bricks, old size bricks, straight or curved onplan exceeding 6 metre mean radius built in cement mortar 1:6but except bricks complete all as specified and directed. |
| 20 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 21 | Dismantling water tanks and removing to store of water storage tanks (Cap. 250 ltr to 500 ltr ) complete all as specified and directed. |
| 22 | Supply and fixingRotational moulded polyethylene water storage tanks of 500 litres capacity,(cylindrical vertical with closed top) with plastic lid cover, triple layered, white, hoisted and fixed in position all as specified in SSR Part-I including PTMT Ball valves high pressure with epoxy coated Aluminium rod & high density plastic ball complete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections complete all as specified and directed. |
| 23 | Supply and fixing in repair Gun-metal, globe or gate valves, with iron wheel head,screwed both ends for iron pipe of 20 mm bore pipe, including making connections complete all as specified and directed. |
| 24 | Taking up or down steel tubing of 15 mm bore pipe and connections,including cleaning for re-fixing or removal to store, complete all as specified and directed. |
| 25 | Taking up or down steel tubing of 20 mm bore pipe and connections,including cleaning for re-fixing or removal to store, complete all as specified and directed. |
| 26 | Taking up or down steel tubing of 25 mm bore pipe and connections,including cleaning for re-fixing or removal to store, complete all as specified and directed. |
| 27 | Supply and fixing tubes \"medium grade\" galvanised, 15 mm bore, ISI marked with all fitting such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed. |
| 28 | Supply and fixing tubes \"medium grade\" galvanised,20 mm bore, ISI marked with all fitting such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed. |
| 29 | Supply and fixing tubes \"medium grade\" galvanised,25 mm bore, ISI marked with all fitting such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed. |
| 30 | M&L cutting chases, pinning in , making good to facings where required and pointing in cement mortar1:3 to ends or edges of landings,steps,cills,sunshades,shelves,lintels etc,and cutting chases for concealed water tubing or concealed conduit wiring,etc,and making good,cutting n.exc 10cm girth in brick walls. |
| 31 | Dismantling floor, hearth or wall tiling including cement mortar bedding, terrazo dado from wall surface(but not backing), removing serviceable tiles to store and rubbish off the premises. complete all as specified and directed. |
| 32 | Material and labourNon - skid , Ceramicjoint lesscoloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and set in neat cement slurry and pointed with coloured/white cement to match the surface over and including15 mm thick screed bed in CM 1:4.Complete all as specied and directed. |
| 33 | Material and labour glazed ceramic colouredtiles in vertical surface300x450x7 mm thick, set and jointed in neat cement slurry and pointed white or colored cement to match the surface over and including 10 mm thick CM 1:4 complete all as specified and directed. |
| 34 | Material and labourVitrifiedCeramic light shade tiles10 mm thick (square/ rectangular) polishedarea of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and set in neat cement slurry and pointed with coloured/white cement to matchover and including15 mm thick screed bed in CM 1:4., complete all as specified and directed. |
| 35 | Description all as item No 35 but as in vertical surfaces dado/skirting over and including a backing coat of CM 1:4, 10 mm thick complete all as specified and directed. |
| 36 | Material and labourNon - skid Ceramicjoint lesscoloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and set in neat cement slurry and pointed with coloured/white cement to match the surface over and including15 mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 37 | Description all as item No 37 but as in vertical surfaces dado/skirting over and including a backing coat of CM 1:4, 10 mm thick complete all as specified and directed. |
| 38 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) n.exc 1.5 Sqm each including cutting holes for taking out hold fast or dismantling brick work and removing from sitecomplete all as specified and directed. |
| 39 | Taking down chowkats or frames with shutter (without taking off shutter from the frame)exc 1.5 Sqm&n.exc 4 Sqm each including cutting holes for taking out hold fast or dismantling brick workand removing from site complete all as specified and directed. |
| 40 | S&F pressed steel framesof size 125mm x 60mm made outof size 1.25mm thick MS sheet for doorssingle rebated including mild steel hinges medium weight 100 mm long and 25mm x 3mm flat iron in holdfast,tie bar including necessary fixinglugs, hold fast, lock strike plate and fixing arrangement etc complete as specified and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 including PCC 1:3:6 as in back fill to chowkats complete all as specified and directed. |
| 41 | S&F pressed steel framesof size 105mm x 60mm made outof size 1.25mm thick MS sheet for doorsdouble rebated including mild steel hinges medium weight 100 mm long and 25mm x 3mm flat iron in holdfast,tie bar including necessary fixinglugs, hold fast, lock strike plate and fixing arrangement etc complete as specified and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 including PCC 1:3:6 as in back fill to chowkats complete all as specified and directed. |
| 42 | S&F Flush shutters, 30 mm thick solid core construction, Both side Lemination with glossey finish ,complete complete all as specified and directed. |
| 43 | Supply and fixing 35mm thick2nd Class hard wood glazed,gauzed and skelton shutters open rebated and prepare to receive glass, gauge etc but divided into squares with plain chamfered or rounded mitredand rebatedsash bars,stiles and rails as specified in SSR Part-I Sec 8 clause 8.24 (a)complete all as specified and directed. |
| 44 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm Plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specifications and drawing including making good to disturbed surface of walls, complete all as specified and directed. |
| 45 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppplyingand fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 46 | All as per srl item No. 45 but wire gauzed ie.panel will be of wire gauze in lieu of PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly.The quoted rate is included for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm, complete all as specified and directed. |
| 47 | Repair/ easing ofwooden door any type, glazed or panelled, by trimming the side of door shutter where rubbing with chowkhat, unscrew the hinges screws and lift the door and fix with screws, tightening of wire mesh etc complete all as specified and directed. |
| 48 | Pressed steel cup board frameof MS sheet 1.25 mm thick size of frame 60 x 40 mm with rebate of 20 mm wide and 12 mm deep including PCC 1:2:4 as in filling to back of chowkats includingbutt hinges 100 mm long. Piano hinges measured separately, complete all as specified and directed. |
| 49 | Prelaminated MDF board 19 mm thick as in shutters/shelves (exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame worknincluding lipping (15 mm thick three sides and 20 mm thick lipping hinge side) around the shutter complete all as specified and directed. |
| 50 | Dismantling Stone slabs in roofs, suspended floors, chajjas, landings, etc., any thickness, jointed in any mortar, complete all as specified and directed. |
| 51 | M&L 16 to 18mm thick green udaipur marble in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over 15 mm thick CM 1:4 complete all as specified and directed. |
| 52 | M&L 16 to 18mm thick Granite (of any type)work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over 15 mm thick CM 1:4 complete all as specified and directed. |
| 53 | M&L Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 54 | Supply and fixingin repair Galvanised mildsteelwire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 55 | S&F butt hinges of mild steel cold rolled medium weight of size 100mm complete all as specified and directed. |
| 56 | S&F Aluminium anodised, barrel tower boltssize 150 mm of extruded section and fixed complete all as specified and directed. |
| 57 | S&F Aluminium handles, fabricated type, anodised Size-100mm, anodised section and fixed complete all as specified and directed. |
| 58 | S&F Aluminium alloy, anodised, sliding door bolt Size- 250 mmwith hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 59 | S&F aluminium hanging floor door stopper,Twin rubber stopper,size 100mm , anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete all as specified and directed. |
| 60 | S&F in repair aluminium bottom door seal with brushes, length 1.2 mtr, fix with screw, suitable for wooden door complete all as specified and directed. |
| 61 | Supply and fixing in repair mild steelhelical ordinaryrat tail rod patternsprings300mm including roller and roller plate complete including fixing to pressed steel frames necessary welding work complete all as specified and directed. |
| 62 | Dismantling PVC/Cement/CI pipes 50 to 110 mm diaincluding allfittings like bend,branch pieces, connectors, heel rest bend etc and removing from site complete all as specified and directed. |
| 63 | S&F cast iron soil, waste and vent pipes 100 mm borein any length with or without ears, with cement joints,, laid in trenches or in floorscomplete all as specified and directed |
| 64 | S&F cast iron soil, waste and vent pipes 100 mm bore in any length with or without ears, with cement joints,fixed to wall , including stack clamp of GI flat 50 mm wide 5 mm thick fixed to wall with nail at spacing of 1m center to center , complete all as specified and directed. |
| 65 | S&F cast iron soil, waste and vent pipes 75 mm borein any length with or without ears, with cement joints,, laid in trenches or in floors complete all as specified and directed |
| 66 | S&F cast iron soil, waste and vent pipes 75 mm borein any length with or without ears, with cement joints,,fixed to wallincluding stack clamp of GI flat 50 mm wide 5 mm thick fixed to wall with nail at spacing of 1m center to center , complete all as specified and directed. |
| 67 | S&F CI Pipes 100 mm bore bends (diminishing pieces or tapper) any radius |
| 68 | S&F CI Pipes 75 mm bore bends (diminishing pieces or tapper) any radius |
| 69 | S&F CI Pipes 100 mm bore bends with access door(diminishing pieces or tapper) any radius |
| 70 | S&F CI Pipes 75 mm bore bends with access door(diminishing pieces or tapper) any radius |
| 71 | S&F CI Pipes Branch pieces single equale and Un equale ordinary and Inverted (spigot and socket type) or with Parallel branches 75 mm bore, complete all as specified and directed. |
| 72 | S&F Cast Iron Pipes (SWR) vent cowl 75 mm dia complete all as specified and directed. |
| 73 | S&F Cast Iron Pipes (SWR) vent cowl 100 mm dia complete all as specified and directed. |
| 74 | S&F in repair 25mm outer dia stainless steel decorative drapery rod of thickness 20 gauge and for every 01 RM length, with stainless steel brackets near to ends with stainless steel finialsfor 25mm dia drapery rod at both ends. The drapery rod shall be projecting 150 mm outer side from the clear opening of doors/windows, complete all as specified and directed. ( Including necessary fittings) |
| 75 | S&F in repair 15 mm bore Bib Cock long Bodywith wall flange cast copper alloy, chromium plated fancy type ,complete all as specified and directed. |
| 76 | S&Fin repair 15mm bore angle valve with wall flange , cast copper alloy, chromium plated fancy type screwedfor 15 mm iron pipe, complete all as specified and directed. |
| 77 | S&F in repair 15mm bore CP Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 78 | S&F in repair Tubular towel rail, 20mm dia, D type, 60cm long between flangescomplete all as specified and directed. |
| 79 | S&F in repair Chromium plated,towel ring, complete all as specified. |
| 80 | S&F in repair Corner Glass Shelf (with Bracket) as per directed by Engr-in-charge. |
| 81 | S&F in repair PVC connection 15 mm x 450 mm including brass check nut at both ends screwed for iron pipe of 15 mm bore. |
| 82 | S&F in repair, PVC cabinet mirror ofselected quality glass approved size (330mm x 430mm),fix with screw complete all as specified. |
| 83 | S&F in repairBrasschromiumplatedshower rosewith or without swivel joints, 125mm size, including fixing to steel pipe or union |
| 84 | S&F in repairVitreous China, wash basin white, flat back , size 400mmx300 including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32 mm dia, waste coupling of chromium plated brass.complete all as specified and as directed by Engineer-in-charge.. |
| 85 | S&F in repair full pedestal for WHBcomplete all as specified. |
| 86 | S&F in repair PVC valveless,syphonic action type, flushing cistern, low level,white with inlet, ball valve, float and handle including brackets, PVC 32 mm \"L\" bend of capacity 10.0 litres and making good to dismantled/damaged floor/surfaces, fixing in repair, complete all as specified and directed. |
| 87 | Supply and fixing in repair Vitreous china ware pedestal type water closet white, with \"P\" or \"S\" trap including self closing seat cover, closed pattern with flat bottom complete all as specified and directed. |
| 88 | Supply and fixing in repair for bevelled edge mirror of size (600x450mm), selected quality glass approved size , mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with SS screws and cup washers, complete all as specified and directed. |
| 89 | Supply and fixing in repairwall mixer non telephonic shower arrangement with connecting legs and wall flanges, chromium plated, complete all as specified and directed. |
| 90 | S&F in repairSink Mixer with Swinging Spout (Wall Mounted Model) with Connecting Legs & Wall Flanges complete all as specified and directed. |
| 91 | Supply and fixing in repair sinks made of stainless steel 1.00 mm thick kitchen orlaboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 610mm x 460mm bowl size 560mm x 410mm x 200mm complete with CP waste coupling & PVC waste pipe complete all as specified and directed. |
| 92 | S & F Kitchen stainless steel plate rack made out of 1 mm thick sheet and having partions as per sample. The over all size (30\"x36\"x10\") fixed with steel fastners or steel screw complete all as specified and directed. |
| 93 | S&F in repair PVC connection 15 mm x 600 mm including brass check nut at both ends screwed for iron pipe of 15 mm bore, complete all as specified and directed. |
| 94 | S&F in repair stainless steel lock grating plain/hole size 100 mmdiaincluding embeding in tiles with white cement, complete all as specified and directed. |
| 95 | Material ad labour for preparation of new plastered surfaces of walls & applying two coats of oil bound distemper over a coat of wall care puttyand one coat of primer complete all as specified and directed. |
| 96 | Preparationof newplastered/ concrete surfaces of walls to achieve smooth and even surfaceandapplying two coats of cement based paint over and includingone coat of primer (up to 2nd storey with necessary/scaffolding)complete all as specified and directed. |
| 97 | Preparation of old decorated brick /concrete, plastered /un-plastered surfaces of walls, pillars, cornices etc (upto 2nd storey bldgs) by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, rubbing with sand paperand applying one coat of lime white wash on the walls, pillars, cornices etc. complete all as specified and directed. |
| 98 | Complete removal of old decorated brick/concrete/ plastered/unplastered surfaces of walls, Pillars, cornices etcby booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, rubbing with sand paper and applying two coats of oil bound distemper onwalls, pillars,cornices surface including 1.0 to 2.0mmwall care putty coloured in same shade .complete all as specified and directed. |
| 99 | Preparationof old decorated surfaces including brooming down of steel wire scrapping down smokefoot moulds moss and efflorencet salts and trading oil and grasy spots etc. and applying one coatofoil bound distemper over 1.0 to 2.0 mm thk wall care putty on decorated old plastered or un-plastered surface in ceilingcomplete all as specified and directed. |
| 100 | Preparation of old decorated brick/concrete/ plastered/unplastered surfaces of walls, Pillars, cornices etcby booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, rubbing with sand paper and applying one coat of cement base paint on walls, pillars, cornice etc (upto 2nd storey with necessary scaffolding complete all as specified and directed. |
| 101 | Preparation of old painted wooden surfaces having width/girth exceeding 10 cm including necessry putty filling with knife of same colour where required to achieve smooth and even surface and applying one coat of synthetic enamel paint on wood surfaces of any description( up to 2nd storey with necessary scaffolding)complete all as specified and directed |
| 102 | Preparation of New painted wooden surfaces having width/girth exceeding 10 cm including necessry putty filling with knife of same colour where required to achieve smooth and even surface and applying twocoat of synthetic enamel paint on wood surfaces of any description( up to 2nd storey with necessary scaffolding) with a coat of pink primer,complete all as specified and directed. |
| 103 | M&L for 50mm thick cement concrete 1:3:6, type C1, using 20mm graded crushed stone aggregate as in plinth protection, laid in slope of 1:20 and surface finished even and smooth without using extra cement including making joint at 3m interval and at each corner the joint shall be filled with bitumen mastic filling to full depth (comprising one part hot blown bitumen 85/25 and two part of sand), complete all as specified and directed. |
| 104 | M&L Aluminum Power coated, sliding window/Ventilators three track with mosquito proofing with style 44.4x44.5x2mm thick including 4 mm thick coloured/tinted/frosted glass panes including all necessary fittings and fixtures complete all as specified and directed. |
| 105 | M&L Anodised aluminium grills, 6mm dia size 100x100mmfixed to aluminium windowsand thickness of powder coating not less than 50 micron, complete all as specified anddirected. |
| 106 | Supply and fixing Factory made, plain framed, panelled shutter (One/two Panel) 35mm thick,2nd class Hardwood with lock rail and panel of 9 mm B.W.P commercial ply. The size of rail and stiles as per as per IS:1003 (Part-I),kiln seasoned and chemically pressure treated complete all as specified anddirected. |
| 107 | Supply and fixing Galvanised mildsteelwire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specifiedfixed with stainless steel wire staples. |
| 108 | Hacking out old broken glass (any thickness,size quality or description) from any types of wooden/steel/alum (up to 4th storey) frames or stone concrete or brick surrounds glazed with putty or fixed with beads, complete all as specified anddirected. |
| 109 | S&F3.5 mm thick sheet glass ordinary quality glazing with oil putty or any type of beads in square n.exc. 0.5 Sq each pane in any type of frame of iron/Steel/Wood/Aluminium as required at site complete all as specified (uptofourth storey with necessary scaffolding), complete all as specified anddirected. |
| 110 | S&F 3.5 mm thick figured glass, pin head type and glazing with oil putty or any type of beads in square n.exc. 0.5 Sq each pane in any type of frame of iron/Steel/Wood/Aluminium as required at site complete all as specified (uptofourth storey with necessary scaffolding), complete all as specified anddirected. |
| 111 | S&F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165 |
| 112 | Material & labourfactory made steel windows double shutter box type, outer frame made out of ERW TUBE \"P\" section (60x45x25mm) and shutters of ERW TUBE \"P\" section (50x35x20mm) operable shutters side hung includding pistol hinges with two Nos of MS Tower bolts 150mm size on each shutter steel handle and stopper of \"Z\" section as specified complete with sash bars devetailed or welded ready for glass fixing and wire gauzed fixing with suitabel fittings/openning for cooler/AC where required .Steel windows will be double shutter external glazed and internal wire gauzed complete all as specifed and as per Drg No CEPZ/TD-324/07 1/3 to 3/3 all as specified and directed by Engr-in-Charge.NOTE: The quoted rate against the above item shall also include (i) 04 Nos MS Steel lugs of 20x5mm MS flat 20cm long over all welded to frames (ii) PCC block for embedding lugs. |
| 113 | Ditto all as per item No 113 but in Ventilators any size. |
| 114 | Providing and fixing of V-board-\"Visaka\"/E-board \"Everest\" make 600x600x4mm thick white prelaminated seif embosed reinforced designer ceiling board tiles of approved texture at all height laid on Hot dipped Galvanised iron imposed grid with 24 mm wide T-section exposed flanges which shall be power coated white. The frame work shall comprise of main runner made from 0.33mm thick G S sheet and of size 24x32x3000mm and spaced at 1200mm centers securely fixed to the structural soffits by approved hangers at 1200mm maximum centers. Hangers/suspended with 2 run of 2 mm dia of GI wire to be fixed by approved rawl plug, level and justers and screws etc. The last hanger at the end of each main runner shall be greater than 450mm from adjacent wall. Flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runners at 600mm center to form 1200x600mm modules cross tee longer than 600 mm to be supported independently.600x600 mm modulesto be formed by fitting 600 mm long cross Tee centrally between the 1200mm cross tee. Tee, Perimeter wall angle shall be of 0.45mm thick GS shgeet of size 19x19mm and 300 mm long of white colour all as specified by manufacture instruction. |
| 115 | Preparation of old painted steel surfaces having width/girth exceeding 10 cm including necessry rubbing with sand paper or grinding by hand grinder to achieve smooth and even surface and applying one coat of synthetic enamel paint on steel surfaces of any description( up to 2nd storey with necessary scaffolding)complete all as specified and directed |
| 116 | Preparation of New steel surfaces having width/girth exceeding 10 cm including necessry rubbing with sand paper or grinding by hand grinder to achieve smooth and even surface and applying two coat of synthetic enamel paint over a coat of Red oxide primer on steel surfaces of any description, complete all as specified and directed |
| 117 | Supply and fixing in repair mild steelhelical ordinaryrat tail rod patternsprings300mm including roller and roller plate complete including fixing to pressed steel frames necessary welding work complete all as specified anddirected. |
| 118 | S & F 3.5 mm thick sheet glass ordinary quality glazing with oil putty or any type of beads in square exc. 0.5 Sq each pane in any type of frame of on/Steel/Wood/Aluminium as required at site complete all as specified (uptofourth storey with necessary scaffolding), complete all as specified anddirected. |
| 119 | S&F in repair 25mm outer dia stainless steel decorative drapery rod of thickness 20 gauge and for every 01 RM length, with stainless steel brackets near to ends with stainless steel finialsfor 25mm dia drapery rod at both ends. The drapery rod shall be projecting 150 mm outer side from the clear opening of doors/windows. ( Including necessary fittings) |
| 120 | Taking down carefully copper/aluminium point wiring (light, fan, light & power socket) complete with fittings and fixtures such as switches,ceiling rose ,pendents ,regulators,socket,lampholders brackets,bulk head fitting,tube lights etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should bemade as per conditions separately) and also making good distrubed surfaces of wall,floors etc complete all as specified anddirected. |
| 121 | M & L for point wiring for one light/one fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) with in and including PVC concealed conduit having thickness not less than 1.8 mm with all fittings including steel sunken box,for moduler wiring, for switches and sockets , including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash /colour wash to matching with the existing colour and all as specified and directed.Note: (a) Insulation test of point wiring (b) colour coding is to bemaintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green) |
| 122 | One light/Fan point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sq mm earthing) |
| 123 | All as per srl item No 125 above but for call bell point complete all as specified and directed. |
| 124 | One 5 Amp socket outlet on independent board. |
| 125 | One 5 Amp socket outlet on same board. |
| 126 | All as per Item Srl No 125 above but for one socket outlet 15 Amps on Independent board using cable (2.5 Sq mm for Phase & neutral and 2.5 Sq mm for earthing). |
| 127 | S&F Sheet metal enclosure factory made (double door) shutter type for DB SPN, 240 Volts, 8 ways with 200 Amps rated bus bar, neutral link, earth bar complete. |
| 128 | S&Fin replacementSPN 40 to 63 Amp, type \"C\"10KA, 240 Volts. |
| 129 | S&Fin replacement MCB SP 5 to 32 Amp, \"C\"10KA, 240 Volts. |
| 130 | Supply and fixing switch modular 6amps 230 volts one way switch. |
| 131 | S&Fsocket 6Amps AC 230 VOLTS 2/3 pin combined 2 modular type complete all as specified and as directed. |
| 132 | S&Fsocket 6A/16Amps AC 230 VOLTS 2/3 pin combined 2 modular type complete all as specified and as directed. |
| 133 | Supply and fixing switch modular 16amps AC230 volts one way switch complete all as specified and as directed.. |
| 134 | Supply and fixingModular white cover plate with frame 2 module and metal flush box 2 module complete all as specified and as directed. |
| 135 | Supply and fixing modular fan regulator step type120W-2module |
| 136 | Supply and fixingModular white cover plate with frame 3 module and metal flush box 3 module complete all as specified and as directed. |
| 137 | Supply and fixingModular white cover plate with frame 4 module and metal flush box 4 module complete all as specified and as directed. |
| 138 | Supply and fixingModular white cover plate with frame 6 module and metal flush box 6 module complete all as specified and as directed. |
| 139 | Supply and fixingModular white cover plate with frame 8 module and metal flush box 8 module complete all as specified and as directed. |
| 140 | Supply and fixingmodular Bell push 6amps 230 volts 1 module |
| 141 | S&F ceiling rose 3 terminal size 50*65 mm surface type. |
| 142 | S&F LEDLights fitting 1x18 watt,220V, AC Decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified anddirected. |
| 143 | S&F Replacement for angular typeLamp holder PVC policarbonate type with back plate including Lamp 7Watt complete all as specified anddirected. |
| 144 | Earthing complete with galvanised earth plate electrode 60 cmx 60 cmx 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of the plate not less than 1.5M belownormal GL connected to GI wire 4mm as earthing lead by means of nut,bolts and check nut and washer,GI light grade protection pipe 15 mm dia. upto 7.5 m,GI watering pipe 20 mm dia,RCC cover with funnel,excavation in any type of soil,PCC pit charcoal ,salt all as shown in electrical plate No 5 of SSR Part I, including earth test point up to pannel board,all as specified or indicated including testing on completion, complete all as specified anddirected. |
| 145 | 22.S & F of sheet metal enclosures distribution boards, double door ,VTPN, 415 volts 4 ways (one incoming three phase & twelve out goings single phase )for MCCB & MCB,s comprising three phase four wire copper strip bus bar of appropriate capacitycomplete all as specified and directed and comprising of the following a) MCCB FOUR POLE 100 AMPS AC415 VOLTS16 KA=01 NO(for incoming )(b) MCB SP 63 amps = 04 Nos (for outgoings) . ( Note :- (i)TheDB shall be VTPN seriesof Make : Schneider ,cat part no:A9HVD04L or equivalentmake of L&T/ ABB/Legrand . (ii) The DB shall be flush fixed and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of the MCCBs/ MCBs with cableshall be made through appropriate size pin /bottle type thimble properly crimped.(iv)All the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. (vi) cutting chasing shall be part of job at no extra cost . |
| 146 | 23.S& F LED Street light fitting 35 watt 230 v AC out door type with high pressure die complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65/66 protection complete all as specified anddirected. |
| 147 | 24.M & L for submain wiring with copper conductor PVC insulated FRLS of size 2 x 10 sqmm alongwith earth wire of size 1 x 10sqmm on wall surfacewith and including PVC casing caping of suitable size complete all as specified anddirected. |
| 148 | Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail