Tender For Construction Of Stadium At Kakkanad,Thrikkakara Lac, Ernakulam - Kerb, Fencing, Drain and existing Retaining wall repair 2 2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 3 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 4 100.98.1008 : Engaging Coolie 5 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 6 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 7 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 8 4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 9 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 10 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 11 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 12 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 13 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 14 od72323/2024_2025 : Lifting, conveying and fixing the newly casted RCC covering slabs of any thickness on top of drain in position including all labour charges and miscellaneous expenses etc complete (Based on MoRTH 55.25 ) 15 od72330/2024_2025 : Steel work for fencing with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete(Rate based on CPWD 50.10.2) 16 16.70.1 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm 17 13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works 18 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 19 od72331/2024_2025 : Supply and Installation of approved quality 2mm thick UV Stabilized Nylon net of Mesh size not greater than 50mm in existing GI poles including all charges as per the direction of Engineer in charge.(rate based on DAR 26.81) 20 Synthetic Football Turf 21 od199133/2024_2025 : Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 30 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth including all lifts and leads, hire charges of machineries, labour charges etc complete as per the direction of engineer in charge. All kinds of soil. ((Based on CPWD-2.6.1, 16.1,30.2.8 & MoRTH-3.6 & 3.16) 22 od199147/2024_2025 : Providing and fixing PVC pipes with 5 mm dia perforations, minimum 125 perforations per running metre, in trenchesat required slope, as per specifications etc complete including the cost of all materials, labour etc. and as directed by the Engineer-in-charge.Care should be taken while laying so that the perforations shall be along the bottom side of the pipe. The rateincludes cost of all materials, covering the pipe with Geo Textile Cloth,labour charges for trenching carriage of surplus earth to a lead of 50m etc complete. including jointing of pipes with one step PVC solvent cement etc complete as per direction of Engineer-in-Charge 150 mm dia 6 Kgf/cm2. 23 od72324/2024_2025 : Providing ,Laying, spreading and compacting stone aggregate of specified size 20mm downgraded metalas filter media around the drainage pipes in the sides of trench as per the directions of Engineer-in-charge. Rate inclusive of all materials,transportation and labour charges complete.The work has to be executed as per detailed specifications, and or as approved by Engineer-in charge. 24 od193461/2024_2025 : SKF_OD 8/2022-2023 Supply and Laying 120 GSM Geotextile Membrane as per direction of Engineer - in - Charges. 25 od72325/2024_2025 : Providing , laying and spreading of compacted fill with 40mm metal (Coarse Rubble Granite Stone) combined with a downgraded stone up to 30mm to form a contour and elevations in uniform thickness, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, as per Drawings. Rate inclusive of all materials, transportation and labour charges complete. The work has to be completed as per detailed specifications andas approved by Engineer-in-charge. The measurement shall be taken after consolidationbased on level survey conducted. 26 od72326/2024_2025 : Providing ,laying and spreading of compacted fill with 20mm metal (Coarse Rubble Granite Stone) to form a contour and elevations in uniform thickness, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, as per Drawings. Rate inclusive of all materials, transportation and labour charges complete. The work has to be completed as per detailed specifications andas approved by Engineer-in-charge.<br>The measurement shall be taken after consolidationbased on level survey conducted. 27 od72327/2024_2025 : Providing ,laying and spreading of compacted fill with 10mm metal graded(Coarse Rubble Granite Stone)to form a contour and elevations in uniform thickness, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, as per Drawings. Rate inclusive of all materials, transportation and labour charges complete. The work has to be completed as per detailed specifications andas approved by Engineer-in-charge. The measurement shall be taken after consolidation based on level survey conducted. 28 od199167/2024_2025 : Supply and Installation FIFA approved quality Synthetic Football Turf of Pile height 50 mm with PU backing , stabilizing infill of Quartz sand 25 Kg/sqm and performance infill back SBR Rubber 8 Kg/sqm as per the direction of officer in charge. A test certificate of compliance to FIFA specification is mandatory during physical inspection at site along with test report on material Design, receive material, installation, testing and commisioning of synthetic surface for football including laying, jointing, fixing in position to sub base including all according to methodology and drawings and specifications approved by FIFA including line marking to FIFA specification all complete. The complete installation should be to FIFA approved international standards. 29 od228312/2024_2025 : Supply and installing Movable type premium quality outdoor Football Goal Post of size 24x8 feet made with heavy duty MS Pipe of size 4 dia for main frame with supports Back frame with PU finishing including all fittings such as premium quality Nylon net, Hooks, solid wheels etc. for elevens court. 30 19.35.1 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes. 31 Mud Volleyball Court and Interlock work 32 od228282/2024_2025 : SKF_OD 7/2022-2023 Supplying and stacking for measurement sieved red earth at site including royalty and carriage upto 5 k.m. lead, all labour charges for stacking, loading and unloading etc complete.( Based on CPWD 30.2.2 & 30.2.4.3) 33 od228283/2024_2025 : SKF_OD 4/2022-2023 Supplying and stacking for measurement Sieved Jamuna Sand at site including cost of sand and carriage upto 5 k.m. lead all labour charges for stacking, loading and unloading etc complete.( Based on CPWD 30.2.2 & 30.2.4.3) 34 od228284/2024_2025 : SKF_OD 2/2022-2023 Mixing earth and jamuna sand in the required proportion specified or directed by the Officer-in-charge including all cost of labour charges,hire charges of machineries etc complete.(Based on CPWD 30.2.9) 35 od228285/2024_2025 : SKF_OD 3/2022-2023 Spreading of earth and jamuna sand in required thickness as per direction of officer-in-charge including all cost of labour charges, hire charges of machineries etc complete. (cost of earth and jamuna sand to be paid separately).( Based on CPWD 30.2.8) 36 od228286/2024_2025 : SKF_OD 10/2022-2023 Consolidation of sub grade with power road roller of 8 to 12 tonne capacity with road roller including making good the undulations etc. including all cost of labour, hire charges, fuel, oil, etc. complete. ( Based on CPWD 16.1) 37 od199168/2024_2025 : Supply and fixing 3.5 inch dia fixed type Volleyball posts with net including all necessary fitting, labor, transportation charges etc complete 38 od193468/2024_2025 : Providing and laying of interlock concrete block pavements having thickness 60mm (M35) as per drawings and technical specification clause 1504 confirming to IS 15658 and laid in required colour and pattern over and including 50mm thick compacted bed of 6 mm metal including edge concreting for 300mm width and 150mm depth with CC M35( @ 0.045 m3/m) 39 Name board and Inauguration stone 40 od199452/2024_2025 : SKF_OD 16/2022-2023 Providing and fixing 18 mm thick gang saw cut, mirror polished, pre-moulded and pre polished, machine cut for inauguration granite stone of required size, approved shade, colour and texture laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) joint treated with white cement, mixed with matching pigment, epoxy touchups including rubbing, curing etc. complete at all levels. Area of slab over 0.50 sqm 41 16.21 : Engraving letters in hard stone 42 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 43 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 44 4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 45 50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 46 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 47 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 48 13.71 : Lettering with black Japan pint of approved brand and manufacture 49 Yard Lighting and Connected works 50 od143687/2024_2025 : SKFOD_Supply, installation, testing and commissioning of Outdoor Type Floor Mounting KSEB metering panel, suitable for accommodating 3 Phase Energy meter and consisting of 3 nos. of 40 A cutout with HRC fuse( or as per KSEB) , neutral link in separate chamber, inter connections etc. as required, andincluding necessary supports of min.1.5 mtr height and the panel fabricated out of 14 SWG CRCA sheet with locable door with sealing facility having glass window for energymeter, sealing facility for KSEB, top canopy and necessary overhang, undergone seven tank process ,powder coated finish and all mounting accessories. 51 od143688/2024_2025 : SKFOD ODP - Supply, Installation, Testing and Commissioning of Outdoor Lighting Panel (ODP) cubicle type, totally enclosed, IP 65, pedestal mounted, free standing with top canopy, dust and vermin proof, water proof suitable for operation on 3 phase, 415 V, 50Hz AC supply fabricated using 2mm thick CRCA sheet, powder coated, including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) including following switchgears accessories for the LT Panel. The work shall be completed with all other accessories as per approved SLD. INCOMER 63 A/40A, FP,25kA MCCB- 1 No.63 Amp TPN bus barsINSTRUMENTS; Surge protection device –Type 1+2 Voltage protection level should not be less than 1.5 kV , ;4A, C curve SP MCB - 3 Nos, RYB indication lamp OUTGOINGS10 A, C Curve SP MCB - 15 Nos (arranged by 3X5). 52 90.11.1.10 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 53 90.11.1.14 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP 42/43) 54 2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 55 2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 56 2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 57 2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 58 2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 59 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 60 90.12.5.41 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 4 core 16 sq mm 61 90.12.5.13 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 6 sq mm 62 90.12.5.40 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 4 core 10 sq mm 63 90.12.5.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3.5 core 50 sq mm 64 90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 16 sq mm with factory made clamp 65 90.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 50/38 mm or nearest size 66 90.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 1.50 sq mm 67 9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 68 9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) 69 9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) 70 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor (10 SWG) 71 90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG) 72 5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 73 90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 2.50 sq mm 74 90.11.1.19 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (8+18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/TP MCB as outgoing (IP 42/43) 75 90.12.10.3 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 63/50 mm or nearest size 76 90.15.4.4 : Supply Conveyance, installation, testing and commissioning of 100W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea withpower factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 77 5.1 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. 78 od228199/2024_2025 : Dismantling of existing 12 mtr height Floodlight pole and its foundation, disconnecting and removing of existing 6 Nos of floodlight fittings and connected cabling with all accessories complete and relocating to new location within the ground and refixing the pole and reconnecting the existing floodlight fittings along with necessary additional cables, clamping arrangements, provision for fixing 10/12 Nos of floodlight luminaries with all accessories complete as required. 79 Building Electrification 80 1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A 81 1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B 82 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 83 1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 84 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 85 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 86 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 87 1.23.1 : Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch 88 1.23.3 : Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch 89 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 90 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 91 1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module 92 1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep 93 od211702/2024_2025 : SKFDSROD: Supply and installation of pre-wired 20W LED batten fitting complete with all accessories and tube etc directly on ceiling/wall, including connection with PVC insulated,copper conductor single core cable and earthing etc as required. (Make: Phillips, Crompton greaves, Bajaj, Lucker or Approved by engineering in charge)