Purchase Of Generator For Chapparapadavu Grama Panchayath , Providing Generator Set , Od368417/2024-2025:Supply, Loading, Conveyance, Unloading, And Erection Of 20 Kva Dg Set With Acoustic Enclosure As Per Cpcb 4 Type Norms And As Detailed Below. 1. Engine Model - X2.5-G6 A. Make Of Engine - Cumins/ Volvo Eicher/ Mahindra/ Kirloskar B. Type Of Engine - Diesel Engine. C. No Of Cylinders - As Per Manufactures Standards. D. Method Of Cooling - Water Cooled With Radiator. E. Aspiration - Naturally Aspirated. F. Design - Suitable For Generating Set Operation. G. Output - Suitable For Generating Set Operation. 2. Standard Accessories With Diesel Engine A. Fly Wheel. B. Close Coupled. C. Air Cleaner. D. Radiator With Fan Provided With Fan Guard. E. Fuel Pump. F. Mechanical /Electronic Governor. G. Fuel Filter. H. Lubricating Oil Filter. I. Residential Type Exhaust Silencer. J. Battery Charger / Generator. 3. Engine Instrument Panel With The Following Items. A. Starting Switch With Key Or Button And Remote Control B. Lubricating Oil Pressure Gauge. C. Water Temperature Gauge. D. Rpm Indicator With Hour Meter. E. Battery Charging Ammeter. 4. Safety Controls For Engine A. Battery Control (Trip) For Low Lubricating Oil Pressure. A. Battery Control (Trip) For High Water Temperature. 5. Brush Less Alternator A. Make - Kirloskar/ Stamford/Crompton/Integrated Electric Ltd Or Equivalent Make B. Type - Self Exited And Self Regulated C. Capacity - 20 Kva / 16 Kw @ 0.8Pf D. System Of Voltage - 3Phase, 415V, 4 Wire System. F. Speed - 1500 Rpm. G. Frequency - 50Hz. H. Insulation - Class F/H The Alternator Should Confirm To Is 4722/Is13365. Operation And Service Manual Shall Be Provided 6. Fuel Tank Suitable Size Fitted (Built In Type) Inside The Acoustic Enclosure 7. Battery Suitable Size Fully Charged Battery With Leads And Terminals Of Appropriate Ah Capacity As Per Manufactures Required Including Battery Charger. 8. Standard Control Panel A.63 A 4 Pole Mccb Set At 30 A B. 1No Multi Function Meter Suitable For Display Of Current In 3 Phases, Voltage In 3 Phases, Frequency, Power Factor, Kva, Kvah, Kvar, Kvarh, Kw Etc. C. 1 No Separate Kwh Meter D. Necessary Measuring Cts Of Appropriate Ratio And Burden For The Required Meter. D. Instrument Fuse/Mcb - 2Set F. Metallic Dnb - 1No G. Solid State Phase Indication Lamp For Supply On/Of With Fuse / Mcb Protection , Od367284/2024-2025:Supply Of High Speed Speed Diesel For Test Run , 14.1:Excavation For Foundation In Soft Soil Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 Metres. , 14.7:Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) In Foundation Of Pump, Dg Set Etc Including Form Work Etc As Required. , 14.12:Providing 15Mm Thick Cement Plaster Of Mix 1:4(1 Cement: 4 Fine Sand) At All Levels , 90.12.1.41:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground Including Excavation Of Trench Of Size 35 X 75 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering (In Ordinary Soil).4 Core 16 Sq Mm , 90.12.7.41:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , 9.1.33:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm (28Mm) , 90.16.1.5:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required4.75 Mm Copper Conductor (6 Swg) , 5.4:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Od367293/2024-2025:Painting Letters Or Figures Of The Following Sizes With Enamel Paint As Identification Mark To Sb, Db, Panel Board Etc As Required. 2.50 Cm, 4 Cm Or 5 Cm Height , Od367287/2024-2025:Supply And Providing 5 Kg. Abc Type Fire Extinguisher With Hose And Clamps Including Fixing It To Wall As Required. , Od367289/2024-2025:Supply And Providing 2.0Mm Thick Elastomeric Fire Retardent Insulating Mat As Per Is 15652/2006 To Withstand 3.3 Kv Dielectric Strength. , Od367291/2024-2025:Supply And Providing The Following 25 X 3 Mm Brass Bolt & Nut With Washers On The Existing Ms Box / Earth Bus Etc. As Required Including Drilling Necessary Holes As Required , Od367285/2024-2025:Supply And Providing Test Joint For The Earthing System Using 2 Nos Of 25 X 3 Mm G.I Strips Including Cutting And Bending To Shape, Drilling Necessary Holes And Fixed To The Watering Pipe Etc As Required. , Od367290/2024-2025:Supply And Providing Earth Lead From The Test Joint To The Earth Plate Using 25 Mm X 3 Mm G.I Strip Including Cutting, Drilling Necessary Holes (In Case Of Strip) And Fixing Firmly With Plate Test Joint Etc. As Required. , 90.17.7.4:Providing, Laying, Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 3589/Is 1239 Including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall/Ceiling With Suitable Clamp/Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required :50 Mm Dia , 90.2.1.14:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Rohs Compliant Modular Accessories).Independent Plug - Medium Point , 1.17.3:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 1.5 Sq.Mm , 1.21.1:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm , Od367292/2024-2025:Charges Towards The Preparation Of Necessary Plan ,Scheme And Other Related Documents For Submission To Electrical Inspectorate/Kseb For Approval Of Generator Installation. , Od367286/2024-2025:Statutory Fee And Other Deposit Amount To Electrical Inspectorate/Kseb For Approval Of Generator Installation.