}

Tender For Dt Increasing Work Under Nagar Nikay Under Edsd Second, Under Ee,Edd,Barabanki. - Safe Loading Carriage Including Unloading And Proper Stacking Of Following Materials From Central Store Barabanki / Je Store To Site Of Work. 2 Pcc Pole 8.5 Mtr, barabanki-Uttar Pradesh

Madhyanchal Vidut Vitran Nigam Limited has published Tender For Dt Increasing Work Under Nagar Nikay Under Edsd Second, Under Ee,Edd,Barabanki. - Safe Loading Carriage Including Unloading And Proper Stacking Of Following Materials From Central Store Barabanki / Je Store To Site Of Work. 2 Pcc Pole 8.5 Mtr. Submission Date for this Tender is 01-03-2025. Transformer Supply Tenders in barabanki Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

47929370
Tender For Dt Increasing Work Under Nagar Nikay Under Edsd Second, Under Ee,Edd,Barabanki. - Safe Loading Carriage Including Unloading And Proper Stacking Of Following Materials From Central Store Barabanki / Je Store To Site Of Work. 2 Pcc Pole 8.5 Mtr
Open Tender
NCB
Uttar Pradesh
Barabanki
01-03-2025

Tender Documents

Tender Details

Tender For Dt Increasing Work Under Nagar Nikay Under Edsd Second, Under Ee,Edd,Barabanki. - Safe loading Carriage including unloading and proper stacking of following materials from central store Barabanki / JE Store to site of work. 2 PCC POLE 8.5 MTR LONG 3 S/S Base Angle 4 T/F11/0.4KV, 63 KVA 5 T/F11/0.4KV, 100 KVA 6 T/F11/0.4KV, 250 KVA 7 MS Top Channel 8 T-off Channel 9 MS Channel (Dropper) 10 LT ABC (3*120+1*95+1*16) SQMM 11 LT ABC (3*95+1*70+1*16) SQMM 12 LT ABC (3*50+1*35+1*16) SQMM 13 L.T XLPE Cable (1*400)SQ MM 14 L.T PVC Cable (1*400)SQ MM 15 11 KV Composite Polymer Pin Insulater 16 11 KV Composite Polymer Disc Insulator With Fitting 17 Earthing Rod 18 ACSR WEASEL CONDUCTOR 19 GI wire 8 SWG 20 Stay Set complete 21 Dragging of pole from JE Dump Store to site 22 Grouting Of STP/PCC Pole 23 Erection of Stay set of 16x1800 mm rod duly painted with red oxide,anchor plate, thumble turn buckle andstay insulate etc. digging of pit of size of size 0.4x0.6x1.6 m for grouting 1:3:6 cement concrete, with stay of size 7/8 SWG, nuzzling & Grouting. 24 Installation of Mounting of Following capacityof Transformer including its connection between 11 KV and LT Line mountingprovinding Crimping type Aluminium lugs of required size.( All the material except transformer will be arranged by the contractor) 25 Mounting of 63 KVA Tranformer 26 Mounting of 100 KVA Tranformer 27 Mounting of 250 KVA Tranformer 28 Stringing and sagging of 11 KV line with ACSR Weasel Conductor including nuzzling binding and jumpering (Weasel conductor will be provided by the department) 29 Errectionof Substation type double pole with ST/PCCincluding mounting of Top Channal Dropper Channel, base angle with clamps with nut & bolt 33/11 KV line including grouting of support and plinthing 300 mm above ground level, fitting of 33/11 KV pin & Pin insulator. 1/6 of total lenght of poles will remain under the ground and planted on stone pad of Size 300x300x75 MM. 30 Stringing and Sagging of LT single core Cable (1x400) SQMM (LT Cable will be provided by the department) 31 Stringing and Sagging of LT ABC Cable(3*120+1*95+1*16) & (3*95+1*70+1*16) and (3*50+1*35+1*16) SQMM (LT Cable will be provided by the department) 32 Laying ofL.T XLPE Cable (1*400)SQ MM(LT XLPE Cable will be provided by the department) 33 MS Earthing Rod. 34 Provinding & Fixing of various type materials. All materials shall be supplied by the contractor. 35 Nut & Bolt 36 Clamp for Top/ Dropper and T-off Channel etc. 37 Dead End Clamp 38 Holding Clamp 39 L-Piece 40 I-J Hook with clamp 41 Al Lug 120 sqmm 42 Al Lug 400 sqmm 43 3 Phase D.O FUSE SET Complete 44 Construction Of LT DistriBution Cum LT Protection Piller Box MS Angle in RectangleSize 50x50x6 MM 7.5Meter long For installation Of Henley Type Tailleness Fuse Unit 300 AMP 650 Volt For 3 nos Outgoing Circuits With Copper Bus bar OF size 1000x50x6 mm Including Proper Grouting of Structure By Digging OF pits Off Size 300x300x600 mm With the Help Of Cement, Coresand And Aggregate in the ratio 1:3:6 And Fabrication of structure Complete. 45 Wiremesh fencing of 11/0.4 KV substation shall be made rectangular off size as per site requirement not exceeding 3 meter fabrication 45x45x5mm angle. material shall be supplied by the contractor. 46 Construction of massionary type transformer plinth of Suitable sizewith brick ,cement, coarse sand , sand & brick ballast. Filling of sand in the hollow space , plastering , outer surface in ration 1:4:6 top of the plinth 4 thickness grouting of 2 nos MS Channel of size 100x50x2000 mm on the top of the plinth for placement of transformer . All material shall be supplied by the contractor. 47 Erection of pipe type earthng for DT with the help of B-Class G.I pipe of size 1.5 inch dia, 40 feet deep boring by providing G.I strip 50x6 MM, 6 meter long attached with clamp L-piece nut & bolt & G.I cap

Key Value

Document Fees
INR 3540 /-
EMD
INR 51500.0 /-
Tender Value
INR 51.15 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail