| 1 | Supply, Installation, Testing, Commissioning of High Mast Light in front of mechanical Workshop and all Machine Yard. Swaged steel tubular pole (410SP-11) of hight 8 mtr. Conforming to IS:2713 (Part II) in three section with steel base size, bottom of the pole made of 50mm dia MSB Clamp pipe welded to 300 mm long MS canopy of suitable dia at an angle of 102.5 suitable size of nut and bolts including rating of one coat steel primer and two coat of red oxide all complete as required.(with arm) |
| 2 | Supply and fitting of Single Arm 1 meter long. |
| 3 | Supply and fitting cable junction box. |
| 4 | Erection of metallic pole of following lengthin cement concrete 1:3:6(1 cement:3coarse:6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc.as required(Above 6.5 metre and upto 8.0 meter) |
| 5 | S.I.T.E of 120 W LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltsge 100-270V AC, 50HZ. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be omplete with all neccssary accessories as required(Make Havells,Philips,Surya, crompton, Bajaj only) |
| 6 | Supply of PVC/XLPE insulated PVC sheathed heavy dutty, armoured electrical cable with aluminium conductor for working voltage up to 1100 volts.(conforms to IS:1554, Part-1), 3.5 core 35 sq. mm (Make Havells, KEI, Finolex, R R Kabel, polycab only) |
| 7 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq. mm direct in ground including excavation, sand cushioing,protective covering and refilling the tranch etc as required. |
| 8 | Supply and fitting of Outdoor stand mounted feeder panel with 63A TPA MCB inomer, 63amp TP contactor automatic switching of liuminaries, power tool control inommer outgoing terminal etc as requried. |
| 9 | Supply and fixing 6 amps to 32 amps rating, 240 volts, 10 KA,\"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.(6/32 amps, single pole, DP)(Make Schneider, Legrand, Havells, Anchor, ABB only) |
| 10 | Earthingwith G.I earth pipe 4.5 mtr long,4omm dia includingmaccessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. With charcoal and salt as required |
| 11 | Painting with aluminium paint of approved brand and manufacture to give an even shade. (2 X 3.14 X 0.145 X 3.04m + 2 x 3.14 x 0.12m x 1.79m + 2 x 3.14 x 0.1 x 2.22m) x 29nos. Street existing light poles |
| 12 | Supplying ,installation testing commissining of 1200mm(48\") ceiling fan 3 blades confirming to IS:374:2019 Including wiring the down rods of standerds length(up to 30 cm) with 1.5sq.mm.FR PVC insuladed,copper wire suitable for 230v 50Hz, single phase supply etc. complete as required. |
| 13 | S.I.T.E of 100W LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 Protection) in existing pole/pipe for supply voltage 100-270v AC, 50Hz Luminarie shall be confirm to IS:10322 Part-5/section-5 and shall be complete with all neccssary accessories as required. |
| 14 | supply installation testing commissining of High mast Light in mechanical work shop. Supply of 20 mtr, high mast in two section construction S355 grade as per BS-EN 10025 Top dia 150mm, bottom dia 410 mm, plate thickness 3mm, 20 mm side polygon galvanisation as per BSEN ISO 1461, base plate dia 570 mm base plate thickness 25 mm GI single spike lighting protection, maximum wind speed 47m/s with 8 nos foundation bolts of PCD 490mm TS 600/30MM Dia/850mm long, Luminaries carring Materials for 50NB ERW class B- M.S Pipe dia of carriage ring 535mm (ID) with 6 arm,welded, 2 sections havingcapacity up to 12 luminaries. Trailing Cable; 5 core 4 sq.mm PVC flexible copper conductor which/power tool : Double drum SWL 750 Kg with 1 HP6 pole single speed integle motor rope : Grade AISI 316,7/19 construction , dia 6mm, BLC 2350 X 2 having 2 nos of continues rope . Aviation obstruction light : twin dome aviation obstruction light LED Type as required. (But excluding Feeder piller) |
| 15 | ITC of the high mast and light fixture with the help of suitable toola and plants wiring material like PVC insulated PVC sheathed flexible cable of suitable copper conductor lugs, MCB and all labour & construction of shallow foundation with M25 grade onrete for thehigh mast considering safe soil bearing capacity of 10T/mtrs sq. for 20M High mast |
| 16 | S.I.T.C of 240 LED Flood lighting luminarie with pressure die cast housing and toughtened glass cover (IP 66 protection) in exixting pole for supply voltage 100-270V AC, 50Hz , Luminarie shall be confirm to IS: 10322 part-5/section-5 and shall be complete with all necessary accessories as required (Make Havells, philips, Surya, Crompton, Bajaj only) |
| 17 | Supply of PVC/XLPE insulated PVC sheathed heavy dutty, armoured electrical cable with aluminium conductor for working voltage up to 1100 volts.(conforms to IS:1554, Part-1), 3.5 core 25 sq. mm (Make Havells, KEI, Finolex, R R Kabel, polycab only) |
| 18 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq. mm direct in ground including excavation, and refilling the tranch etc as reqd. but excluding sand cushioing and protective covering.. |
| 19 | Supply and fitting of Outdoor stand mounted feeder panel with 63A TPA MCB inomer, 63 amp TP contactor automatic switching of liuminaries, power tool control inommer outgoing terminal etc as requried. |
| 20 | Earthingwith G.I earth pipe 4.5 mtr long,4omm dia includingmaccessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. With charcoal and salt as required |
| 21 | Supply and laying 8 5WG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc as required. |
| 22 | SOLAR PANEL IN ROOF TOP OF MECHANICAL OFFICE Supply installation ,testing commissioning of solar photovollaio grid corrected roof top plant confarming to MNRE specifications(a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years, (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ system must be warranted for their out peak wayy capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b)power conditioning unit (PCU) of 350-800 V DC Input Voltage range and 400V AC, Three phase,4 wire, 50Hz+/-2.5Hz output voltage suitable to generate AC. (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient tempertature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency. (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g)Connection & interconnection by supply & fixing required size XLPE insulated copper conduction 1.1 KV grade connection armoured power and cable b/wn solar moduled main power cable to grid supply PVC unit along with supplying & giving of necessary channel/conduct lays and other accessories etc as required. |
| 23 | Add GST @18% |
| 24 | Add Labour Cess @1% |