| 1 | DRAINAGE WORK |
| 2 | OD412847/2024-2025:For cleaning site |
| 3 | OD412881/2024-2025:Bailing out water using pump above 5 HP and Up to 10 HP-Bailing out water with engine and pump set above 5HP and up to 10HP, including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete |
| 4 | 3.5.1:Excavation in Cutting in Soil by manual means with lead upto 50 mExcavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 |
| 5 | OD407916/2024-2025:Filling with Quarry MuckFilling up low lying and water logged areas with local material/ quarrymuck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete forimproving the CBR value of subgrade |
| 6 | OD407917/2024-2025:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203I. P.C.C grade M 10(i) Nominal mix 1:3:6(Without shuttering) |
| 7 | 11.4.2.1:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 II. P.C.C grade M 15(i) Nominal mix (1:2.5:5) |
| 8 | 75.8.1.1.A:Providing Plain cement concrete for wearing coat CC 1:2:4 (1 cement: 2 fine aggregate:4 course aggregate) laid to required slope as required including compaction, finishingand tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixedin concrete mixer etc complete as per specification(i) Nominal mix (1:2:4) |
| 9 | OD412864/2024-2025:[OD From DAR 60.7.1] - DRY RUBBLE MASONRY _ Dry rubble without concrete levellingcourse masonry with good quality blasted rubble including packing to compactness to lines andlevels cost and conveyance of all materials labour charges etc. complete as per direction ofDepartmental officers at site |
| 10 | 12.7:Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 11 | 12.5.3:Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 For height upto 5 mIII. R.C.C grade M 20 |
| 12 | OD412846/2024-2025:Providing and fixing M.S. Grills of required pattern in frames of drainage top etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel frame by welding |
| 13 | OD407915/2024-2025:Supplying and fixing name board in Granite stone 60x90cm fixed at site with CM 1:4, 12mmthick including all cost and conveyance of materials labour charges etc. complete |