| 1 | INTERNAL ELECTRIFICATION WORKS |
| 2 | M&L for point wiring with 1.5sqmm PVC insulated unsheathed multistranded1100V gradecopper FRLScable with one run of 1.5sqmm PVC insulated copper cable as earth continuity drawn in existingConcealed/ surface PVC conduitfor one light point/ fan point/bell point controlled by one switchincluding 1.0mm thick prefabricatedconcealed galvanised boxes with hylem cover plate of suitable size for fixing switches, sockets regulator and connected the earth wire to common earth dolly , including Taking down carefully copper / aluminium point wiring complete along with fittings such as switches ,Sockets, ceiling rose , lamp holder etc. Note:- Rate includes all cutting & chasing on existing wall/ceiling and also includes making good to match the existing wall / ceiling finishesthe disturbed surfaces of wall / ceiling complete all as specified and directed by the Engineer-in-Charge. |
| 3 | All as per item No 1 here-in-before but for 5A socket point on same board complete all as specified |
| 4 | All as per item No 1 here-in-before but for 5A independentsocketpoint complete all as specified |
| 5 | Allas peritem No 1 here in before but one light point controlled two switches.complete all as specified |
| 6 | All same as per item No.1 above but with 4 sqmm PVC insulated unsheathed multistranded copper FRLS grade cable with one run of4 sqmm PVC insulated copper cable as earth continuity for power socket on independent board. |
| 7 | Material and labour for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including 20mm PVC conduit totally concealed/surface conduit in walls/ceiling with tee, bend, elbows, junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including 1.0mm thick prefabricated concealed galvanised boxes with white modular cover plate & frame of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dollyforOne light/fan point/bell point/5 Ampindependent Socket point controlled by one switch including taking down the existing old wiring of any description and type complete all as specified and as directed.Note:-(i) All the disturbed surfaces of wall / ceiling shall be made good to match the existing wall / ceiling finishes and the rate also include all the cutting, chasing and cementing work and as directed by the Engineer-in-Charge. |
| 8 | All as per item No 2 here-in-before but for 5A socket point on same board complete all as specified |
| 9 | All as per item No 2 here-in-before but for 5A socket point on independent board complete all as specified |
| 10 | All same as per item No.2 above but with 4 sqmm PVC insulated unsheathed multistranded copper FRLS grade cable with one run of4 sqmm PVC insulated copper cable as earth continuity for power socket on independent board. |
| 11 | Supply and fixing Modular switch 1 way 6A, 1 module single polecomplete all as specified and directed by Engr-in-charge. |
| 12 | Supply and fixing Modular switch 1 way 16A, 1 module single polecomplete all as specified and directed by Engr-in-charge. |
| 13 | Supply and fixing in repairmodular Socket, 6A - 2/3 pin combined 2 module, 230 volt,multipurpose, complete all as specified. |
| 14 | Supply and fixing in repairmodularSocket 6A/16A - 2/3 pin combined 2 module,230 volt,multipurpose,complete all as specified. |
| 15 | Supply and fixing of modular Fan step regulator, 120W - 2 modulecomplete all as specified. |
| 16 | S & F in repair switch piano flush button, single pole one way 5 Amps, 230V AC supply complete all as specified and directed. |
| 17 | S & FTwo way switch piano flush button 6 Acomplete all as specified and directed by the Engineer-in-Charge. |
| 18 | S & F in repair switch socket combination 3 pin 5 Amps flush type with out gang box, 230V AC supply, complete all as specified and directed by the Engineer-in-Charge. |
| 19 | S & F in repair switch socket combination2 in 1 5 pin, 5/15 Amps flush with out gang box, 230V AC supply , complete all as specified and directed by the Engineer-in-Charge. |
| 20 | S & F in repair switch socket combination 3 pin 5 Amps flush type with gang box, 230V AC supply, complete all as specified and directed by the Engineer-in-Charge. |
| 21 | S & F in repair switch socket combination2 in 1 5 pin, 5/15 Amps flush with gang box, 230V AC supply , complete all as specified and directed by the Engineer-in-Charge. |
| 22 | S & F in repair bell push piano flush button6A 230Vcomplete all as specified and directed by the Engineer-in-Charge. |
| 23 | S&F in repair electronic fan regulator, upto 300 Watt, 230V AC supplycomplete all as specified and directed by the Engineer-in-Charge. |
| 24 | S & F in repair Calling bell ding dong 230 v AC supplycomplete all as specified and directed by the Engineer-in-Charge. |
| 25 | Supply and fixingin repair ceiling rose surface bake lite 65 x 30mm with 3 terminals complete all as specified and directed by Engr-in-charge. |
| 26 | Removing of light fitting of any type during the wiring work and refixing the same including replacement of 2 core connecting wire complete all as specified and as directedc by Engg in Charge |
| 27 | Supply and fix Hylam sheet required as per existing size in site with screws suitably cutted for existing switch fixtures including removing old one all as directed |
| 28 | S & F LED tube light fittings, retro bar professional WH 5700K to 6200K and minimum 1800/2000 lumens of warm/cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge (Quoted rate includes warranty as per particular specification). |
| 29 | S & F LED light fittings, 2 feet long of minimum 900 lumens of warm/ cool white wall mounted batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge (Quoted rate includes warranty as per particular specification). |
| 30 | S & F wall mounted bulk head LED lightof minimum 700 Lumens warm/cool day lightwith all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge (Quoted rate includes warranty as per particular specification). |
| 31 | S & F Square recessed mounted Slim type LED light (2\"x2\") of minimum 3200 to 3600 Lumens warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge (Quoted rate includes warranty as per particular specification). |
| 32 | S & F Square surface mounted box type LED light (2\"x2\") of minimum 3200 to 3600 Lumens warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge (Quoted rate includes warranty as per particular specification). |
| 33 | S & F Building Security light LED type of minimum 2500 to 3000 Lumens Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge (Quoted rate includes warranty as per particular specification). |
| 34 | S & F in replacement bulb holder (pin pype/threasd type) complete all as specified and as directed by the Engineer-in-Charge |
| 35 | S & F in replacement bulb of 9W (pin pype/threasd type) complete all as specified and as directed by the Engineer-in-Charge |
| 36 | S & F flood light 9000 to10000 Lumens (min) new generation LED with high luminous efficacy, IP66 protected, front toughened glass, energy saving with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge. |
| 37 | S & F flood light 18000 to 20000Lumens (min) new generation LED with high luminous efficacy, IP66 protected, front toughened glass, energy saving with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge. |
| 38 | S&F Cable Junction of size93 x 93 x 62 Boxes IP 66/69“halogen free and weather proof” for 2.5 sq.mm cable for outdoor installation (with same company metric knockouts for cable entry and terminal) Make : Hensel Model : KF 0202 G or its equivalent |
| 39 | Supply and fixing Post top lantern for 360 degree indirectlight with IP- 65 protection 40WAC Supply single phase energy saving, environmental friendly, long life aesthetically designed with resistant to impact and corrosion, Glare free and better uniformity and symetrical lightdistruction spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed. |
| 40 | Taking down ceiling fanfrom its position and doing complete overhauling of fan including dismantling, replacement of fan clamp and split pin, rubber bush refixing the same after repairs complete all as directed by Engr-in-Charge. |
| 41 | M & L for painting of ceiling fan of any sweep with synthetic enamel paint over a paint of primer including filling of cavities complete all as specified and as directed by Engg in charge |
| 42 | S & F in repairs oil capacitor of 2.5 mfd for ceiling fan of any sweep complete all as specified and directed by Engineer- in -Charge. |
| 43 | S & F in repairs bearing of suitable size for ceiling fan of any sweep complete all as specified and directed by Engineer- in -Charge. |
| 44 | M & L for rewinding of ceiling fan motor oftype 1200 mm sweep & any make,with super enameled copper wire of appropriate gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnishetc.complete all as specified and directed by Engineer- in -Charge. |
| 45 | Taking down Exhaust fanof any size from its position and doing complete overhauling of fan includingfan capacitor of 4.0mfd and other spare parts painting with synthetic enamel paint over a paint of primer refixing the same after repairs complete all as directed by Engr-in-Charge.. |
| 46 | M & L Rewinding of Exhaust fan motor of sweep upto 300mm & any make,with super enameled copper wire of appropriate gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, replacing the bearings of suitable size,painting etc.complete all as specified and directed by Engineer- in -Charge. |
| 47 | Taking down Air circulator fanof any size above 450mm sweep from its position and doing complete overhauling of fan including replacement offan capacitor ofupto 6.0mfd and other spare parts, painting with synthetic enamel paint over a paint of primer refixing the same after repairs complete all as directed by Engr-in-Charge.. |
| 48 | S & F in repairs MCCB 3 Pole, 32/40/63 Amps, 50 Hz, 16KA, 415 Volts with all necessary aluminium lugs and glands, etc complete all as directed. |
| 49 | S & F in repairs MCCB 4 Pole, 100 Amps, 50 Hz, 25KA, 415 Volts, with all necessary aluminium lugs and glands, etc complete all as directed |
| 50 | S & F in repairs MCCB 4 Pole, 125 Amps, 50 Hz, 16KA, 415 Volts,adjustable thermal and fixed magnetic type with all necessary aluminium lugs and glands, etc complete all as directed |
| 51 | S & F in repairs MCCB 4 Pole, 160 Amps, 50 Hz, 16KA, 415 Volts,adjustable thermal and fixed magnetic type with all necessary aluminium lugs and glands, etc complete all as directed |
| 52 | Supply and fixingin replacementof Factory made sheet metal enclosure forTPN MCBDBs double door (Fixed flush to the wall), TPN, 415 volt,4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , including taking out old DBs any type & size and making good the disturbed surfaces by using plaster/ PCC/ cement work & match with exiting surface etc , complete all as specified and directed by Engr-in charge. |
| 53 | Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt,8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , including taking out old DBs any type & size and making good the disturbed surfaces by using plaster/ PCC/ cement work & match with exiting surface etc , complete all as specified and directed by Engr-in charge. |
| 54 | Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt,12 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , including taking out old DBs any type & size and making good the disturbed surfaces by using plaster/ PCC/ cement work & match with exiting surface etc , complete all as specified and directed by Engr-in charge. |
| 55 | Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt,4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , including taking out old DBs any type & size and making good the disturbed surfaces by using plaster/ PCC/ cement work & match with exiting surface etc , complete all as specified and directed by Engr-in charge. |
| 56 | Supply and fixingof MCB 6 to 32AmpS, 240 Volt, SP, breaking capacity 10 KA \"C\" series,complete all as specified |
| 57 | Supply and fixingof MCB 6 to 32AmpS, 240 Volt, SPN, breaking capacity 10 KA \"C\" series, , complete all as specified |
| 58 | Supply and fixing ofMCB 40-63 AmpS, 415 Volt, TPN, breaking capacity 10 KA \"C\" series, , complete all as specified |
| 59 | Supply and fixingof MCB 25 to 63 AmpS, 415 Volt, TP, breaking capacity 10 KA \"C\" series, , complete all as specified |
| 60 | Supply and fixingof RCBO, 40 Amps, Double Polee, 30mA - 100mA complete all as specified an as directed. |
| 61 | M&L for sub main wiring withtwo run of 6.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt,and onerun of copper earth wire 6.0Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduictshall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate. |
| 62 | M&L for sub main wiring withtwo run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt,and onerun of copper earth wire 4.0 Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduictshall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate. |
| 63 | M&L for sub main wiring withtwo run of 2.5 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt,and onerun of copper earth wire 2.5 Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduictshall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate. |
| 64 | supply and fix in repair test point terminal box of size 200 x 100 x 100 mm made out of 2 mm thick hot dip galvanised sheet drilled and screwed including 6 Nos 15 mm long hexagonal head screws complete with test point terminal block made out of Gun metal or Phosphorus Bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws, etc complete all as specified and directed. |
| 65 | M&L for Rewinding of rolling shutter/hanger door motor of capacity up to 7.5HP,with super enameled copper wire of appropriate gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, greasing the bearings, replacement of missing / worn out nuts, bolts & washers, split pins etc.including repairing andoverhauling the gear box assembly by metal filling, cutting and other maching process in lathe complete including replacement of bearing of suaitable size and chain link and spocket with mounting shaftall as specified and directed by Engineer- in -Charge. |
| 66 | M&L for replacement of startor single phase/3Phase DOL type suiatable for hanger/rolling shutter two way revolving type (clockwise and anticlockwise both type) complete all as specified and directed |
| 67 | Supply and fix LT cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade confirming to IS-7098 (Part-I) 1988 of size 2 Core x 10 Sqmm drawn through pipes or in road crossings/ paths/drains/ ducts/ floors/ along poles/ equipments etc., ofincluding connecting up using suitable size aluminium lugs testing and commissioning etc., complete all as specified and as directed. |
| 68 | M&L for limit switch LSRS 10A-125,250 or 480 V ACsuitable for shutter/hanger door complete all as directed |
| 69 | S & F in repairs sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete suitable for AC/watercooler all as specified and directed. |
| 70 | S & F in repairs Wall mounted Alternating current socket (Industrial socket) of 32 Amps, 3 pole, neutral and earth (3P+N+E) , IP 44 protection of metal body three phase 415 Volts, 50 Hz with provision of 32 Amps MCB TPN including necessary fixing arrangements complete all as directed by the Engineer-in-Charge. |
| 71 | S & F in repairs Wall mounted Alternating current plug (Industrial plug) of 32 Amps, 3 pole, neutral and earth (3P+N+E) , IP 44 protection of metal body three phase 415 Volts, 50 Hz including necessary fixing arrangements complete all as directed by the Engineer-in-Charge. |
| 72 | S & F in repair Aviation obstruction light LED type filament-less bulb complete including standard fixing arrangements including timer switch complete all as per Bajaj cat part No BGAV 302 LED ot technocommercially equivalent of other specified makes complete all as specifed and as directed |
| 73 | M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI strip of 32x6 mm sizeby means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber, cover slab with angular iron for holding,20mm dia GI medium grade pipe for watering , and water funnel with wire mesh, 40mm dia light grade GI pipe for protection of strip complete all as specified and testing on completion. |
| 74 | M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth wire 4 mm diaby means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber, cover slab with angular iron for holding,20mm dia GI medium grade pipe for watering , and water funnel with wire mesh, 40mm dia light grade GI pipe for protection of strip complete all as specified and testing on completion. |
| 75 | M & L for cleaning around earth pit and pouring of salt water including testing of earth complete including making of proper fininshing and painting complete all as specified and as directed. |
| 76 | M & L for cover slab of earth pit of building complete including placing of iron angular for opening & closing of cover slab and painting complete all as specified and as directed. |
| 77 | M & L for taking down existing electric geysers of any type and capacity including dismantling the spares and cleaning, servicing the geyser by descaling inner body of water tank and cleaning it with soap and acid mixed water, brazing or welding of tank as required andreassembling the geyser set and refixing the same in original position including checking for proper function complete all as directed by Engr-in-Charge. [Note: Quoted rate is deemed to be inclusive for any minor spares such as nut & bolt auto cut, washers, indicating lamp etc as required. However geyser element & thermostat shall be measured and paid seperately] |
| 78 | S & F in repairs geyser heating element 1.5 KW capacity complete all as specified and directed by Engr-in-Charge. |
| 79 | S & F in repairs Thermostat of necessary capacity complete all as specified and directed by Engr-in-Charge. |
| 80 | Supply & Fix in repairs Hot and cold pipes complete along with ncessary nuts and bolts as required and as specified and directed. |
| 81 | Supply and Fix 36W LED driver for 2\" x 2\" LED Light fittings complete all as specified and directed |
| 82 | M & L for Earth continuity conductor or main earthing lead fixed to wall or recess or chasses or buried in groung or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron wire including taking down old unserviceable one complete all as specified anddirected |
| 83 | M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chasses or buried in groung or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25 X 4 mm galvanised iron strip including taking down old unserviceable one complete all as specified anddirected |
| 84 | COOLING APPLIANCE AND ALLIED WORKS |
| 85 | Material and labour for taking down unservieable items and supply and fix new items for the following1.5/2.0 ton Capacity split type AC including testing and commissioning etc complete all as diected. |
| 86 | Starting Capacitor 80/100 MFD |
| 87 | Running Capacitor50/60 MFD |
| 88 | Relay Assembly |
| 89 | Over load protector (O L P) |
| 90 | Remote control suitable for split AC any type/make |
| 91 | Thermostat |
| 92 | Air filters |
| 93 | Condensor fan blade plastic |
| 94 | Blower Motor |
| 95 | Fan Motor |
| 96 | Cabinet wiring Kit |
| 97 | FRLS PVC insulated sheathed 3 core 2.5 sqmm copper cable. |
| 98 | Angle Valve |
| 99 | Capillary tube (copper) 1 COIL |
| 100 | Condensor/evaportor coil unit for A/C of 1.50 Ton capacity |
| 101 | Condensor/evaportor coil unit for A/C of 2.0 Ton capacity |
| 102 | Drain out flexible PVC pipe for Split type AC high quality |
| 103 | PCB board suitable for indoor unit of Split AC of 1.5/2.0 TR capacity, Non inverter |
| 104 | PCB board suitable for indoor unit of Split AC of 1.5/2.0 TR capacity, inverter model |
| 105 | Copper pipe of size 5/8\" for suction line with insulation |
| 106 | Copper pipe of size 3/8\" for discharge line with insulation |
| 107 | Material and labour for taking down unservieable items and supply and fix new items for the followingwater cooler 40/80 Litres capacity and 120/160 Litres capacityincluding testing and commissioning etc complete all as directed . |
| 108 | Relay unit for 40/80 and 120/160 Litres CapacityMake :Keltron/Keil/Saha/Sarold |
| 109 | PVC float ball value, high pressure with polythene float and fly nut screwed to iron pipe or ferrule of bore 15mm suitable for water cooler as per sample |
| 110 | Thermostat switch for 40/80,60/120 litres capacity Make :Sriram/Renutral/Indfoss |
| 111 | Push cock (self colsing) 15mm dia bore brass crome plated |
| 112 | Fan Motor Make:Frogmaster/AUE |
| 113 | Running Capacitor 10 MFD Make :Keltron/Saha/Keil/Sarold |
| 114 | Wiring Kit |
| 115 | Material and labour for taking down unservieable items and supply and fix new items for following for refrigertors 180/300 Litres capacityincluding testing and commissioning etc complete all as directed. |
| 116 | Relay unitMake |
| 117 | Thermostat assembly |
| 118 | Running Capacitor 10 MFD |
| 119 | Wiring Kit |
| 120 | Taking down old unserviceable compressor and Supply and fix new compressor including pumping out oil, cleaning the refrigeration system with CO2 an charging refrigerant gas (R-22/R-407C/R-410A) providing NRV for further topping up of gas and re fixing inposition including complete testing and commissoing testing complete all as directedfor the following appliances: |
| 121 | Split type AC 1.5 Ton Capacity Make: Danfoss/Hitachi/Kirloskar |
| 122 | Split type AC 2.0Ton Capacity Make: Danfoss/Hitachi/Kirloskar |
| 123 | Taking down old unserviceable compressor and Supply and fix new compressor including pumping out oil, cleaning the refrigeration system with CO2 an charging refrigerant gas (R-22/R-407C/R-410A) providing NRV for further topping up of gas and re fixing inposition including complete testing and commissoing testing complete all as directedfor the following appliances: |
| 124 | Split type AC 1.5/2.0 Ton Capacity |
| 125 | Refrigerator 180 to 300 litres capacity |
| 126 | Water cooler 10/80 & 60/120 Litres capacity |
| 127 | Material and labour for charging refrigerant gas R-22 and re-fixing in original position including testing and commossioning complete all as specified and as directed. |
| 128 | Material and labour for charging refrigerant gas R-32/R-410 and re-fixing in original position including testing and commossioning complete all as specified and as directed. |
| 129 | Supply and replacement of metal clad socket single pole and neutral enclosure with a two pin and earth plug top and socket complete with onesingle pole MCB 20 Amps 240 Voltscomplete all as directed. |
| 130 | Supply and replacement ofplug top suitable for AC metal socket complete all as specified anddirected. |
| 131 | Supply and fix thermal insulation material on cooling copper tubing of out going and return copper tubing from indoor to outdoor for each AC set complete all as specified and directed |
| 132 | Supply and fix white insulation tape material on cooling copper tubing of out going and return copper tubing from indoor to outdoor for each AC set complete all as specified and directed |
| 133 | Servicing and cleaning of AC capacity 1.5/2 ton, Indoor and outdoor units fully cleaning,rectify any type of water leakage,finding out wiring circuit default etc complete all as specified and as directed. |
| 134 | Winding Stabilizer transformer in repair of 5 KVA stabilizer single phase 230 volts with copper coil of suitablegauge including transportation dismantling and re fixing testing complete all as specified and as directed. |
| 135 | Dismantling and disconnecting carefully the existing split AC 1.5/2.0 ton capacity after disconnecting the copper pipe and electrical connection disconnecting the indoor and outdoor units complete all as specified and as directed. |
| 136 | Installation testing and commisioning of split AC of any capacity by fixing the indoor and outdoor units and making electric and copper pipe connection complete all as specified and as directed. |
| 137 | Testing leak in system , arresting leak by vacummising the system, dehydration and gas charging to the system including replacement of strainer and capillary tube complete for 1.5/2.0Ton capacity split type/window type AC including necessary welding / bracing works, binding with telfon tapecomplete all as specified and as directed. |
| 138 | Supply and fix in repairs outdoor unit brackets (stand) including taking down outdoor after switching of the circulation gas and removing old brackets and replacing them with new anti rust powder coated brackets including nuts and bolts, refixing the outdoor on the brackets complete all as specified and as directed. |