Procurement Of Disposable And Implants Items For Ctvs Department Rgssh , Part-01 , Oxygenatormembrane(Adult) With Hard Shell Reservoir: 1. Shouldhaveamicroporoushollowfibre Membrane Oxygenator 2. Should Have Open Circuit Configuration 3. Should Have Hard Shell Venous Reservoir Of Capacity More Than 4000Ml. With Built Of Cardiotomy Reservoir With 30? Filter Capacity. 4. Shouldhavebloodflowrange0.5Ltrto7 Ltr/Min. 5. Should Have Priming Volume Less Than 220Ml 6. Should Have High Efficiency Heat Exchanger. 7. Venous Return Port ½” With Rotating Facility. 8. Should Have An Auto Vent Facility. 9. Port Size : Arterial Outlet, Venous Outlet 3/8” Venous Inlet ½” 10. Should Have Sampling Port. , Oxygenator Membrane (Semi-Adult) With Hard Shell Reservoir: 1. Shouldhaveamicroporoushollowfiber Membrane Oxygenator 2. Should Have Open Circuit Configuration 3. Should Have Hard Shell Venous Reservoir Of Capacity More Than 3000Ml. With Built Of Cardiotomy Reservoir With 30? Filter Capacity. 4. Should Have Blood Flow Range 0.5 Ltr To 3.5 Ltr/Min. 5. Should Have Priming Volume Less Than 180Ml 6. Should Have High Efficiency Heat Exchanger 7. Venous Return Port 3/8” With Rotating Facility. 8. Should Have An Auto Vent Facility. 9. Port Size : Arterial Outlet, Venous Outlet 3/8” Venous Inlet 3/8” 10. Should Have Sampling Port. , Oxygenator Membrane (Paed.) With Hard Shell Reservoir: 1. Should Have A Microporus Hollow Fiber Membrane Oxygenator 2. Should Have Open Circuit Configuration 3. Should Have Hard Shell Venous Reservoir Of Capacity More Than 1000Ml. With Built Of Cardiotomy Reservoir With 30? Filter Capacity. 4. Should Have Blood Flow Upto 2.8 Ltr/Min. 5. Should Have Priming Volume Less Than 140Ml 6. Should Have High Efficiency Heat Exchanger. 7. Venous Return Port 3/8” With Rotating Facility And Redurs 8. Should Have An Auto Vent Facility. 9. Port Size : Arterial Outlet 1/4”, Venous Inlet 3/8” With Redurs , Oxygenator Membrane (Neonatal): 1. Should Have Venous Inlet ¼”. 2. Arterial Outlet Port ¼” Tubing Size. 3. It Should Have Least Priming Volume Less Than 70Ml. 4. Arterial Flow Upto 1.2 Ltr/Minute. 5. Approximate Reservoir Capacity Should Not Be 600Ml. 6. Should Have Redurs. 7. Blood Inlet And Outlet Port Size ¼” Redu Able To 3/16”. , Pre-Connected Tubing Pack Adult With Arterial Line Filter: 1. Circuit Diagram Attached. 2. Tubing Should Have Transparent, Medical Implant Grade Pvc Of Class Vi Usp, Marked. , Pre-Connected Tubing Pack Paed. With Arterial Line Filter: 1. Circuit Diagram Attached 2. Tubing Should Have Transparent ,Medical Implant Grade Pvc Of Class Vi Usp, Marked , Pre-Connected Tubing Pack Paediatric Small. With Arterial Line Filter: 1. Circuit Diagram Attached 2. Tubing Should Have Transparent ,Medical Implant Grade Pvc Of Class Vi Usp, Marked , Pre-Connected Tubing Pack Neonatal. With Arterial Line Filter: 1. Circuit Diagram Attached. 2. It Should Have A Good Quality Arterial Filter Pore Size Should Have 35-40 Micron. 3. Tubing Should Have Transparent Medical Implant Grade Pvc Of Class Vi Usp,Marked. , Onlineblood Cardioplegia Delivery System: 1. Should Have In Built High Efficiency Heat Exchanger Of Metallic For Fast Cooling & Re- Warming. 2. Should Have Priming Volume Less Than 80Ml. 3. Should Have Max Flow Rate 1 Ltr/Min 4. Should Have Pressure Drop Not More Than 13Mmhg 500Ml/Min 5. Should Have Blood To Crystalloid Ratio Of 4:1 With Bride Connection Facilities And Interchangeable Tubing Ratio. 6. Should Have Auto-Vent Line System On Accidental Bock Of Cardioplegia Deliver Liner. 7. Pvc Tubing Should Have Medical Implant Grade Of Class Vi ,Usp,Marked. , Ante- Grade Root Cardioplegia Cannula With Side Arm: 1. Should Have Size 12Fr,14 Fr. & 16 Fr. 2. Should Have Regular Tip Stilate With Side Arm For Vent With Flange 3. Selection Strictly On Quality Basis. , Ante- Grade Root Cardioplegia Cannula Without Side Arm: 1. Should Have Size 12Fr, 14 Fr. & 16 Fr. 2. Should Have Regular Tip Stilate With Flange 3. Selection Strictly On Quality Basis. 4. Iso Certification , Coronary Ostial Cannula: 1. Should Have Malleable Shaft, Female Luer Lock, Radio Opaque Flower Tip Selection Strictly On Quality Basis. 2. Size 14, Fr ,12 Fr & 10 Fr , Coronary Ostial Cannula: 1. Should Have Flexible Silicon Pvc Tubing, Female Luer Lock, Radio Opaque Ball Tip Selection Strictly On Quality Basis. 2. Size 12Fr To 20Fr, 14, Fr ,10 Fr 3. Iso Certification , Retrogradecardioplegia Cannula: 1. It Should Auto Inflatable Balloon. 2. Itshouldhavepressuremeasuringline With 3 Way Connector. 3. It Should With Malleable Stilate. 4. Iso Certification , Vent Catheter (Adult): 1. Shouldhaveflexiblewithmalleablestilateand Multiple Side Hole At The Tip Of Cannula 2. The Proximal Part Should Have Memory For Easy Insertion 3. Iso Certification , Ventcatheter (Pead.): 1. Shouldhaveflexiblewithmalleablestilateand Multiple Side Hole At The Tip Of Cannula 2. The Proximal Part Should Have Memory For Easy Insertion 3. Size – 10,13,15, 16 Fr 4. Iso Certification , Rightanglevenouscannula With Wire Re-In-Ford: 1. Shouldhaveflexiblewiringreinforwith Plastic/Metallic Angled Tip. 2. Should Have Depth Marking Assist With Positing. 3. Iso Certification 4. Size : 10,12,14,16,18,20,22,24,26,28,30 Fr. , Singlestagevenouscannula With Wire Re-In-Ford: 1. Should Have Flexible Wire Reinfor, Multiple Side Hole With Smooth Tip. 2. Should Have Depth Marking Assist With Positing. 3. Iso Certification 4. Size : 10,12,14,16,18,20,22,24,26,28,30,32,34, 36 Fr , Two Stage Singlevenous Cannula With Wire Re-In-Ford: 1. Should Have Flexible Wire Reinfor, Multiple Side Hole With Smooth Tip With Side Hole And Stilate. 2. Should Have Depth Marking Assist With Positing. 3. Iso Certification 4. Size 51 X 36Fr, 32 X 40 Fr,34 X 46 Fr, Etc. , Two Stage Single Venous Cannula Flat With Wire Re-In- Ford: 1. Shouldhaveflexiblewirereinfor,Multipleside Hole With Smooth Tip With Side Hole And Stilate. 2. Should Have Flat In Middle 3. Should Have Depth Marking Assist With Positing. 4. Iso Certification 5. Size 51 X 36Fr, 32 X 40 Fr,34 X 46 Fr, Etc. , Clear View Blower: 1. Should Have Malleable Tip With Air Filter 2. Iso Certification , Intra Coronaryshunt: 1. Should Be Flexible. 2. Size 1, 1.25, 1.5, 1.75, 2.0 , 2.25, 2.5Mm 3. Iso Certification , Intra Carotid Shunts: A. Flexible All Sizes 1. It Should Have Inflatable Balloon In Both Ends Of The Lumen (Shunts) 2. Iso Certification , Coronary Artery Epicardial Retraction Clip.: 1. It Should Have Malleable Wire For Better Exposure. 2. Size- 3Mm ,4Mm,5Mm. , Connectors Straight: 1. It Should Be Sterile And Transparent 2. Size Required: ½X ½” , ½ X 3/8” , 3/8 X 3/8” , 3/8 X ¼” . ¼ X ¼” , Connector With Luer Lock: 1. It Should Be Sterile And Transparent 2. Sizes - ½ X ½” , 3/8 X 3/8” 3. Sizes-1/4X14. 3/8X38. 1/4X1/4X1/4 , Y- Connectors: 1. It Should Be Sterile And Transparent. 2. Size : ½X 3/8 X 3/8 , 3/8 X 3/8 X 3/8 ,3/8 X3/8X¼ ,¼X ¼ X 3/8;¼ X ¼ X ¼ , Femoral Venous (Perfusion) Cannula: 1. Should Have Flexible With Wire-Re-In Fordbuilt In Connector With Dilator. 2. Size-10,12,14,16, 18,20,22 & 24 Fr 3. Should Have Iso Certification , Femoral Arterio- Venous (Perfusion) Cannula Kit For Percutaneous Insertion: 1. Arterio -Venous Kit With Dilator And Insertion Kit For Minimal Invasive Cardiac Surgery. 2. All Sizes 3. Kit Should Have Two Seldinger Style Needles. Four Dilators To Guide Wire Length More Than 140Cm Scalpel Blade. 4. Should Have Iso Certification , Femoral-Arterial(Perfusion) Cannula: 1. Should Have Flexible With Wire-Re-In Ford Built In Connector With Dilators. 2. Size- 10,12,14,16,18,20,22 & 24 Fr 3. Iso Approved. , Tieband: Nil , Aortic Cannula With Curve Tip: Should Have Wire Reinford, Side Flange With Curved Tip Size: 16,18, 20, 22, 24 Fr , Aortic Cannula With Curve Tip: Should Have Wire Transparent Reinford, Side Flange With Curvedtip Size: 16,18, 20, 22, 24 Fr , Aortic Cannula With Straight Tip: 1. Size: 10,12,14,16,18,20,22,24 Fr. 2. Shouldhavestraighttipwithsideflangefor Fixation With Auto Venting Facilities. , Paediatric Aortic Cannula.: 1. Should Have Wire Reinford Built In Connector Straight Tip With Movable Auto Venting Stilate For Easy Cannulation. 2. It Should Have / Certification. Size : 8,10,12,14,16 Fr , Arterial Filterpaediatric: 1. Priming Volume Should Not More Than 70Ml Filter Size Should Be 35 To 40? 2. Attached 3/8” Dia. Tubing Loop 3. It Should Have Approved , Sterile Packing Tubing Pvc: 1. Size: (A)½” Dia. Of 10 Feet Length Tubing. (B)3/8” Dia. Of 10 Feet Length Tubing. (C) ¼”Dia. Of 10Feet Length Tubing. 2. Tubing Should Have Medical Implant Grade Of Class Vi Pvc, Usp,Marked. , Cardioplegia Cannula Paed.: 1. Should Be With Stilate And Side Flange For Fixation. 2. Size 18 G Length Of Approx. 6.5Cm , Cardioplegia Cannula Paed.: 1. Should Be With Stilate And Side Flange For Fixation. 2. Size 18 G Length Of Approx. 16Cm , Cononary Ostial Cannula Of Silicon Or Pvc With Side Bulb: 1. Paed & Neonatal With All Sizes , Artriotomy Cannula: 1. Should Have A Polyurethane Tube With Bulb With Female Luer Lock 2. Sizes 2Mm To 6Mm Tip , Ima Cannula With Ball Tip: All Sizes , Double Lumen Venous (Perfusion Cannula): 1. For Veno- Venous Ecmo Support. 2. Shouldhavebloodinletandoutletportwith Connector Certified. 3. All Sizes , Haemoconcentrator Adult: A. It Should Have High Efficiency Haemoconcentrator With Material Of Polysulphone / Polypropylene B. It Should Have Membrane Surfa Area Of 1.0M2 Or Variable To ± 1. C. Primary Volume Of Should Be Less Than 90Ml D. Transmembrane Pressure Should Have Not More Than 500 Mmhg. E. It Should Bewith Tubing Attached/Separate For In And Out Port & Bag. , Haemoconcentrator Peadiatric: A. It Should Have High Efficiency Haemoconcentrator With Material Of Polysulphone / Polypropylene. B. It Should Have Membrane Surfaarea Of 0.7 M2 Or Variable To ± 1. C. Primary Volume Of Should Be Less Than 70Ml. D. Tran Membrane Pressure Should Not Be More Than 500 Mmhg. E.It Should Be Withtubing Attached/Separate For In, Outport& Bag , Haemoconcentrator Neonatal: A. It Should Have High Efficiency Haemoconcentrator With Material Of Polysulphone / Polypropylene. B. It Should Have Membrane Surfa Area Of 0.2 M2 Or Variable To ± 1. C. Primary Volumeshould Not Be More Than 30Ml D. Transmembrane Pressure Should Not Be More Than 500 Mmhg. E. It Should Be With Tubing Attached/Separate For In And Out Port & Bag. , Adult Cardiac Sucker: 1. It Should Be Plastic Bullet Tip With Handle Compatible In ¼”Tubing. 2. Tip Size-5Cm ± 0.5Cm , Paediatric Cardiac Sucker: 1. Itshouldsmallinsize,Plasticbullettipwith Handle Compatible In ¼”Tubing 2. Tip Size-2.5Cm ± 0.5Cm , Pericardial/ Intracardial Sumps: 1. Shouldhaveflutedtipencasedstainlesssteel Sprig. 2. Tip Is Attached To Soft Flexible Tubing Ending With Connector. 3. Sizes 12 Fr To 20 Fr. , Disposable Pressure Transducer Kit.: 1. Kit Should Bewith Disposable Transdur 2 Three Way Stop Cock. 2. Test Port Provision 3. Gold Plated Connector Wires 4. Shouldbecompatiblewiththepresentsetof Monitors. 5. Should Have Integrated Flushing Devi. 6. Shouldhavedifferentcolorcodingforarterial ,Cvp And Pa. 7. Requireinbothsingletransdurkitpackand Double Transdur Kit Pack. 8. Put Arm Strap Provision , Pressure Transducer Kit For Close Blood Sampling.: 1. Kit Should Bewith Disposable Transdur Setwith All Acssory And Cable. 2. Shouldbecompatiblewiththepresentsetof Monitors. 3. Should Have Plated Connected Wires & Provision For Arm Strap 4. Should Have Auto Flushing Devi With Reservoir . 5. It Should Have Self Iling Test Port For Close Blood Sampling To Prevent Blood Loss And Infection. 6. It Should Be Certified. , Leukocyte Reducing Arterial Blood Filter For Extracorporeal Servi.: A. Should Have The Following Specification. B. Leukocyte Reducing 40Micron Surfa Modified Polyster Media To Remove Activated Neutrophils. C. 220 Ml Prime Volume And Flow Rate Of 6L/Min. D. Automatic Air Venting With Dedicated Air Vent E.Marked With 3/8 Inch Barbed Inlet And Outlet Ports And With Bypass Loop. , Bloodcardioplegia Filter With Leukocyte Reduction: A. Should Have The Following Specification. B. Leukocyte Reducing 40Micron Surfa Modified Polyster Media To Remove Activated Neutrophils C. 95Ml Prime Volume And Flow Rate Upto 350Ml/Min D.Marked With 1/4 Inch Connectors. , Pre-Bypassfilterforcbp Circuit: A. 0.2Micron Filter For Priming And Should Have The Following Specification. B. Recirculation Phase. C. Removes Particulate Debris And Microbial Contaminants From Extracorporeal Circuit. D.Markedwith3/8In.Inletand½in.Outlet Ports. E. 220Ml Prime Volume. , Arterial Line Filter For Paediatric Use: A. Should Have The Following Specification. B. 40Micron Lock Woven Polyster Screen. C. Prime Volume Less Then 30Ml With Upto 3L/Min Of Flow Rate. D. Port Design To Allow ¼ Inch. Tubing. , Leukocyteremovalfilterfor Red Blood Transfusion: 1. Should Have The Following Specification. 2. High Efficiency Leucocyte Removal Filter, Polyster Media, For One Unit Of Whole Blood Or Packed Ll. 3. Filter Hold Up Volume Of 20Ml After Recovery And Leucocyte Residual Averaging Less Than 2X 105/Unit. 4. Primes Directly With Red Lls And With Self Levelling Drip Chamber. 5. Marked. , Microaggregatefilter(B.T. Filter): A. Should Have The Following Specification. B. 40Micronfiltertoremovemicroaggregate, Debris And Clots From Stored Or Salvaged Blood. C. Hold Up Volume Of 20Ml. D. Gravity Prime. , Disposable Centrifugal Pump. Adult And Paediatric.: 1. Compatiblewith Sarns Centrifugal Pump. 2. Should Have Iso Certification. , Disposable Centrifugal Pump. Adult And Paediatric: 1. Compatible With Medtronic Centrifugal Pump Adult And Paediatric. 2. Should Have Iso Certification. , Disposable Flow Connector/Sensor For Centrifugal Pump: 1. For3/8”Tubingand¼”Tubingcompatibleto Medtronic Flow Probe. 2. Should Have Iso Certification. , Aortic Punch: 1. Size -3,3.5,4,4.5, 5 Mm 2. Should Have Iso Certification. , Cautryplate Withcordand Connector For Compatibility.: Patented Safety Ring Technology With Cord For Adult And Paediatric As Universal Size ,Disposable Grounding Plates For Electro Surgical Use, With Thin Conformable, Tear Resistant, Fluid Resistant, Occlusive, Polypropylene Backing, Coated With Thick And Soft Hydrophilic Conductive Adhesive Gel. Plate Design To Have Handling Tabs. , Neonatal Triple Lumen: Neonatal Tripple Lumen Radio Opaque Polyurathane Tripple Lumen Catheter 20, 23, 23G, Dilator 5 Fr, Introdur Needle 21G Kit For Injecting Orinfusingdifferentsolutionandmedications. Ntimetermarkingfrom5to12cmguidewire Should Be Nitinol (Kink-Resistant J Guide Wire.) Size- 4.5 Fr- Length-8Cm, 10Cm. Us / Rtified. , Four Lumen Catheter: Pur Four Lumen Intravenous Catheter Trey Presentation Should Contain Only 4 Lumen Catheter 8.5 Fr , 16, 20Cm Length With Lumen Size 16,14,18. 18G Introdur , 1Graduated J Guide Wire , 1 Dilator 1 Secondary Fixation Wing 3 Injection Caps And 1 Scalpel . , Femoralarterialcannula (Adult): Femoral Arterial Cannula (Adult) Seldinger Technique Polyethylene With Radio Opaque Line And Anti-Kink Collar And Wing Hub For Skin Fixation. Size- 1. 20G- Length 8Cm. One Transparent Catheter (Polyethylene), One Introdur Needle, Should One Straight Guide Wire With Flexible Tip. Size- 2. 18G- Length 10Cm. One Transparent Catheter (Polyethylene), One Introdur Needle, Should One Straight Guide Wire With Flexible Tip. Size- 3. 16G- Length 15 & 20Cm. One Polyurethane With 5 To 20 Cm Marking On Catheter, One Introdur Needle, J Guide Wire- Advanr. Us Approved , Femoralarterialcannula (Paed): Femoral Arterial Cannula (Paed) Polyurathane With Radio Opaque Line Introdud By Seldinger Technique With Integral Polyurathane Extension Tube Length 4.5Cm With Fixation Wing. Presented In A Peel-Pack. One Polyurathane Catheter, One Introdurneedle, One Straight Guide Wire With Flexible Tip, One 50 X 50 Cm Drape Sheet. Size- 22G- Length 4, 6, 8, 20Cm. Usapproved , Spirallacto(Polyethylene) Tubing: 1. Spirallycoiledtubing(Polyethylene)Fordrug Infusion. 2. Size- 100, 150, 200, 300 & 400Cm Us/ Rtified , Polyethylene Pressure Extension Tube: 1. Polyethylene High Pressure Extension Tube 2. Size- 11, 30, 50, 100, 150 & 200Cm. Us / Rtified , Anti-Microbial Impregnated Triple Lumen Catheter: 1. Impregnated With Anti-Microbial Agents With Nitinol Kink-Resistant J Guide Wire. A. Adult Size- 7.5 Fr- Length 16 & 20Cm B. Paedsize-4.5Fr-Length6&12.5Cmus Approved , Pur Iv Acss Devi: 1. Polyurathane Iv Acss Devi 2. Size- 16G, 18G, 20G & 22G , Dressing(Film): A. Ultraresistant Thick Drape Used In Under The Retractor, Ultra Absorbent Pad Keeps Surgical Site Dry, Containing Modified Llulose For Good Hemostatic Action, Bactericide Action With Total Incision Covering. Size : 50X50cm, 38.15.10, 38.30.15, 38.45.45, 38.45.60, 3591, 6X7cm Sizes Variable To ± 5Cm B. Absorbent Clear Acrylic Dressings - Transparent Wound Dressing Consisting Of A Clear, Conformable, Absorbent Pad With A Acrylic Polymer Pad Technology Enclosed Between An Outer Low Friction, Breathable, Waterproof, Viral & Bacterial Barrier Film . Perforated Wound Contact Layer Coated With Moist Skin Adhesive .Pad Size Should Be Slightly Short Then The Dressing Size Variable To ± 2Cm 1. Dressing Size: 6 Cm X 5 Cm, 2. Dressing Size: 9Cm X 6.5Cm, 3. Dressing Size: 7.5Cm X 9.5Cm, 4. Dressing Size: 11 Cm X 12.5Cm, 5. Dressing Size: 15Cm X 15Cm, 6. Dressing Size: 14.5Cm X 15.5Cm, 7. Dressing Size 8.5Cm X 10.7Cm, 8. Dressing Size: 20Cm X 10Cm, 9. Dressing Size: 17Cm X 19Cm , Surgical Brush And Povidone Iodine: With Sponge Impregnated 12% Povidone – Iodine In A 15Ml Solution Of Teepol, P.E.G. And Water Supplied With Nail Cleaner , Surgical Brush And Chlorohexidine: With Sponge Impregnated 20% Chlorohexidine – Iodine In A 15Ml Solution Of Iso Propyle- Alcohol And Water Supplied With Nail Cleaner. Us Approved , Polyurathane Long Cannula: Size- 16G, 18G, 20G, 22G & 24G Us Approved , Anti Uav Extension Line: 1. Anti Uav Extension Line For Light Sensitive Drugs 2. Size- 100, 150, 200Cm 3. Us Approved , Thermodilution Catheter 5 Lumen With Insertion Kit: 1. Catheter Should Have Five Lumen 2. Percutaneous Insertion Kit Separately With All Acssory 3. Iso Certification , Triple Lumen Cvp Kit Paed.: 1. Lumen Size- 18/20/18 G 2. Material Polyurathine, J Type Preferable Nitinol Guide Wire For Anti Kink. Needle Dilator . 5Ml Syringe Inside The Kit 3. It Should Be Approved Size-5.5 Fr. 8Cm , Etoandplasmasterilizer Indicator.: Nil , Chest Drainage Catheter: (Iso/): 1. Thoracic Drainage Catheter. 2. Extra Soft Catheter Is Gentle To The Body Tissues & Most Suitable For Thoracic Drainage. 3. Distalendisopenwithsupersmoothlarge Eyes To Maximize The Drainage From The Chest. 4. Proximal End Is Fitted With Specially Designed Tapered Tongue To Provide Exllent Forpsgrip And Non- Traumatic Insertion. 5. Catheters Are Marked At Every 2Cm From The Last Eye To Asrtain The Depth Of Plament. 6. Sterile, Double Packed In Peelable Pouch Pack. 7. Should Be /Iso Approved , Angled Chest Drainage Catheter: (Iso/): 1. Thoracic Drainage Catheter With Angle. 2. Extra Soft Catheter Is Gentle To The Body Tissues & Most Suitable For Thoracic Drainage. 3. Distalendisopenwithsupersmoothlarge Eyes To Maximize The Drainage From The Chest. 4. Proximal End Is Fitted With Specially Designed Tapered Tonguetoprovide Exllentforpsgrip And Non- Traumatic Insertion. 5. Catheters Are Marked At Every 2Cm From The Last Eye To Asrtain The Depth Of Plament. 6. Sterile, Double Packed In Peelable Pouch Pack. All Sizes 7.Should Be /Iso Approved , Under Water Seal Bottle (Chest Drainage Bottle). (Iso/): 1. Double Chamber Compact Unit Has2ltr Capacity Making It Suitable For All Cardiac And Thoracic Produres. 2. Easy To Read Graduation Help To Determine The Drainage Volume Precisely. 3. Clearly Marked Initial Level Ensures The Under Water Seal. 4. Separate Suction Port Is Providedfor Connection With Suction Unit. 5. Kink Resistant Large Bore Tubing Facilitates Unrestricted Flow. 6. Unit Is Provided With Metal Hangers And Floor Stand. , Snugger Set: Adult And Paediatric , Embolectomycatheter: Size 4,5,6 Fr Usa / Rtified , Tenckhoff Catheter Adult: For Peritoneal Dialysis Should Have Usa / Rtified Size Adult , Tenckhoff Catheter Pediatric: For Peritoneal Dialysis Should Have Usa / Rtified Size Pead , Tenckhoff Catheter Neonatal: For Peritoneal Dialysis Should Have Usa / Rtified Size Neonatal , Graft Embolectomycatheter: Size 4,5,6,7 Fr , Anti Microbial Incise Drape Size 34X35 Cm, 56X45 Cm: 1. Incise Drape Comprise Of Polyester, Thin, Breathable Low Memory Idophor, Impregnated Film. 2. Drape Should Be Coated With Pressure Sensitive Acrylate Adhesive , Antimicrobial Drape For Minimally Invasive Surgery Size 26X20 Cm: Polyester Film Idophor Coated With Hypo Allergic Adhesive Incise Drape Differentiated By A Frame Delivery System For One Person Application. , Reinford Disposable Gown: Made Non-Woven Fabric With 100% Polyester Cuffs, Latex Free, Sleeves And Set-In-Sleeves Seams Are Ultrasonic Welded, Double Layered With Reinforment Layer On Chest And Forehand Area, Fluid Repellant, Fire Resistant, Eto Sterilized,Packed With 2 Hand Towel. , Sterile Disp. Drape Kit For Open Heart Surgery: A. Cabg Pack - Sterile Wrap Size : 115Cm X 115Cm, Back Table Cover, Reinford 152Cm X 230Cm-1Pc, Tape Strips 10Cm X 55Cm -2Pcs, Suture Bags-2Pcs, Back Table Cover, Reinford 140Cm X 190Cm- 1Pc, Utility Drape With Tape 75Cm X 75Cm-1Pc, Perineal Drape 188Cm X 242Cm With Split 45Cm X 95Cm & Positioning Tape &Control Plus Fabric Reinforment- 1Pc, Cv Split Drape 320Cm X 224Cm X 295Cm With Positioning Tape & Control Plus Fabric Reinforment -1Pc. Bar Drape 193Cm X 239Cm With Positioning Tape & Tube Holders & Control Plus Fabricreinforment- 1Pc. Size Variable To ± 2Cm. It Should Have / Rtified. B. Valve Replament Drape - Drape With Size 264Cm X 364Cm X 194Cm, Size Variable To ± 2Cm With Pouches Control Plus Fabric Reinforment, Tube Holders With One Utility Drape Sheet. It Should Have Iso Certification C. Cardiac Produre Drape With Adhesive Incise Area On Chest & Legs - One Drapewith Armboard Covers 108 Inch. X 80 Inch. X 126 Inch, 12 Inch. X 15 Inch. Chest Adhesive Incise Area, 22 Inch. X 38 Inch. Leg Adhesive Incise Area, Heavy Duty Fabric, Control Plus Fabric Reinforment, Longitudinal Flaps, Tube Holders. It Should Have / Approved , Act Tubes: Compatible With Actalyte Act Machine , Act Cartridge: Compatible Withmedtronic Act Machine , Vascular Graft Eptee: Size 3, 3.5, 4, 4.5 ,5 ,6, 8 Mm X 10Cm Size 6,7,8Mm X 30,40,50,60,70,80,90Cm Should Have/ Rtified , Vascular Graft Eptee With Thin Wall: Size 3, 3.5, 4, 4.5 ,5 ,6, 8 Mm X 10Cm Size 6,7,8Mm X 30,40,50,60,70,80,90Cm Should Have/ Rtified , Vascular Graft Eptee With Thin Wall And Carbon Coated: Size 3, 3.5, 4, 4.5 ,5 ,6, 8 Mm X 10Cm Should Have/ Rtified , Vascular Graft Eptfe: Size 16,18,19,20,22 Mm X 20,30,40 Cm Length Should Have/ Rtified , Dacron Swage Graft: Size 7Mm An8 Mm Length 10Cm Or More , Soft Cloth Reinforment Dressing: A. Central Venous Catheter Dressing With Effective Antimicrobial Action. Polyurethane Film With Reinforment Of Soft Cloth 8.5Cm X 11.5Cm & Size: 7 Cm X 8.5Cm . Single, Sterile, Transparent, Semi-Permeable, Water And Bacteria Proof, Thin Conformable Polyurethane Film With One Half Laminated With Soft Cloth Breathable Backing For Enhand Grip On Challenging And Cvc Applications. Has A Long Slit To Conform Around The Civ And & Micro- Porous Label. Has Two Extra Secural Tape For Added Strength & Better Securement. With Unique Paper Window Frame Delivery Design. B. Iv Kit With Transparentdressingfor Peripheral Inserted Catheters : Single Pack Single, Sterile, Transparent, Semi-Permeable, Water And Bacteria Proof, Thin Conformable Polyurethane Film With One Half Laminated With Soft Cloth Breathable Backing For Enhand Grip On Challenging And Cvc Applications. Has A Long Slit To Conform Around The Piv And & Micro-Porous Label. Has Two Extra Secural Tape For Added Strength & Better Securement. With Unique Paper Window Frame Delivery Design Wipe Impregnated With 2% Chlorhexidine Gluconate And 70% Isopropyl Achohol, Synthetic Polyisoprene Based Textured Surfa Material Oftourniquet (Latexfree) Sterile Gauze Pie. , Transparentdressingforpost Opp.: Single Sterile Non-Adherent Absorbent Pad (Compressed Rayon Fiber) Bonded To A Larger Soft Cloth Macro-Porous, Stretchable, Rounded Corners Backing, Coated With A Border Of Hypoallergenic, Water-Resistant Pressure Sensitive Hypo-Allergic Adhesive. 6X8cm, 9X15cm, 9X20cm, 9X25cm, 9X30cm Size Variable To ± 2Cm. , Transparent / Soft Cloth Dress. With Abs. Pad: Single, Sterile,Transparent,Semi-Permeable, Water And Bacteria Proof, Thin Conformable, Polyurethane Film Coated With Water Repellant Acrylate Hypoallergenic Adhesive With Paper Window Frame Delivery And Having A Non Adherent Absorbent Pad (Compressed Rayon Fiber) For Very Good Absorbent And Strike Through Effect. 5X7cm, 8X10cm,9X15cm, 9X25cm, 9X35cm Size Variable To ± 2Cm. , On Line Cardiac Output Monitoring Transdur & Kit: Compatible With Edward Monitor. , Eptfe Cardiovascular Patch: Thickness – 0.6 Mm/0.4 Mm Size-Inches 50 X 75 Mm , Eptfe Cardiovascular Membrane: Thickness – 0.1 Mm Size-Inches 50 X 75 Mm , Eptfe Felt Soft & Hard: Sizes-5 X 7.5Cm & 4” X 4” , Dacron Cardiovascular Patch.: 4 X 4 “ , Dacron Cardiovascular Patch.: 2 X 2 Inches , Closed Circuit Suction Set: Nil , Multi Vessel Perfusion Adaptor: Should Have Four Arm With Pinch Clamp , Disposable Tubing Organizer.: Should Have Port For Multi Sized Perfusion Tubing. E.G. 3/16, ¼, 3/8,1/2,Inch Tubing. , Double Lumen Endobronchial Tube: All Sizes Both Side (Rt. & Lt) Usa / Rtified. Should Have With Endobronchial Blocker , Bifurcated Rapid Priming Set: Should Have 1/4” Bifurcated With “Y” Connector Should Have Spike In Both Ends , Pressure Dome P 20 Red: Should Have Sterile With Male Luer Lock. , Linear Cutter 75Mm Tlc 75 (Ref): Should Have Sterile. , Linear Stapler: Should Have Sterile. , Blade Sternalsaw: Compatible For Sarns Sterna Saw , Monopolar Hand Cautery Pencil (Disposable): It Should Have Universal Three Pin Connector For All Kinds Of Major Cautery Machines. , Tip Cleaner (Disposable) For Monopolar Hand Cautery Pencil: Tipcleanershouldbeintheseparatesterile Packing. , Monopolar Hand Cautery Pencil (Disposable) Cautery With Pencil Tip Cleaner (Disposable): It Should Be Sterile And Supplied In Sterile Packing With Cautery Pencil Tip Cleaner. , Cautery Switch With Polyurethane Coated Surgical Tip: Button Switch Pencil With Polytetrafluoroethylene Coated Electrosurgical Tip. , Cautery Tip: Polytetrafluoroethylene Coated Electrosurgical Ball Tip, Size – 5 Cm , Male To Male Connector: It Should Have Male Luer Lock In Both Ends. It Should Have Iso Certification , Vial Adapter: For Withdrawal Of Sterile Solution From Sterile Vial To Maintain Sterility It Should Have Iso Certification , Eye Shield Fog Free Mask With Visor: 1. It Should Be Consisted Fog-Free Multilayer With Visor. 2. It Should Be Made Of Pleat-Styple With Ties. 3. It Should Have High Fuild Resistan Capability. 4. It Should Have Particular Filtration Efficiency More Than 99%. 5. It Should Have Baterial Filtration Efficiency More Than 99%. 6. It Should Have Iso Certification. , Fluid Shield Fog Free Mask: 1. It Should Be Consisted Fog-Free Multilayer. 2. It Should Be Made Of Pleat-Styple With Ties. 3. It Should Have High Fuild Resistan Capability. 4. It Should Have Particular Filtration Efficiency More Than 99%. 5. It Should Have Baterial Filtration Efficiency More Than 99%. 6. It Should Have Iso Certification. , Microbial Sealant: 1. It Should Have Antibacterial Properties. 2. It Should Be Made Of Cyanoacrylate Technology. 3. Itshouldbecapabletosealand Immobilizes Dangerous Pathogens/Mrsa. 4. Itshouldbeeasy-To-Useapplicator, Polymerized In Less Time. Size:(A) Approximatecoverage:25Cmx 25Cm, (B) Approximate Coverage: 25Cm X 50Cm 5. It Should Have Iso Certification. , Long Cardiopleagia Cannula (Forminimal Invasive Surgical Produres): 1. It Should Have A Length Of More Than 30Cm With Luer Connection. 2. It Should Be Supplied With A Stainless Steel Introdur Needle. 3. It Should Be In Following Sizes 12 Ga/9Fr. 12Ga/9Fr. 4. It Should Have Iso Certification , Disposable Soft Tissue Retractor(Protector) For Minimal Invasive Cardiac Surgery: 1. It Should Be Mode Of Latex Free Silicone Rubber 2. It Should Have High Flexibility For Easy Insert In Situ. 3. It Should Be Capable For Self Holding, For Incision From 7 To 12Cm. 4. It Should Have Iso Certification. , Disposable Coronary Arteriotomy Knife: 1. It Should Be Sterile With, In Builthandle. 2. It Should Have Straight Sharp Pointed Tip For Arteriotomy. 3. Tip Size Should Not Be More Than 1Mm. 4. Shouldbeabletomakeaclearincised Arteriotomy Of Arteries <1Mm In Size. 5. Should Have / Approved. , Disposable Vascular Clamp Inserts: Forbetter Grip And Minimizing Trauma , Suture Organiser Disposable For Valve Surgery: 1. Shouldbe Ableto Stabilizesuturesforvalve Surgery. 2. Should Not Damage The Sutures. 3. Suture Should Not Get Entangled. 4. Capable Of Holding 10-20 Sutures 5. Should Have Sticking In The Bottom So It Adheres To Drapes , Compression Adhesive Bandage For Leg/Arms: 1. It Should Have Medical Grade Bio- Compatible, Pressure Sensitive And Trauma Free Adhesive. 2. It Should Be Breathable Latex Free. 3. It Should Have Maximum Pressure Compression For Legs Or Arms Of Harvested Veins And Arteries For Coronary Grafting. Sizes Variable To ± 1 Meter Long A. 10 Cm X 4,5,6 Meter Long. B.05 Cm X 4,5,6 Meter Long , Silver Mesh Dressing: 1.It Should Have Antimicrobial Cotton, Non Woven Gauze. 2.It Should Have Soft Comfortable Impregnated With Silver Sulphate. 3.It Should Have Various Sizes And Sizes Variable To± 02 Cm. Sizes Variable To ± 1 Meter Long A. 10 Cm X 10Cm B.05 Cm X 05 Cm C. 10Cmx 20Cm D 20Cm X 20 Cm , Vsd Ring: Cloth Bases , Sterile, 2 Circular Cloth With Ntral Hole , The Lower Cloth Should Be Bigger Than The Upper One, 2 Cloths Stitched At 12,3,6 And 9O Clock Positions , Part-02 , Intra Aortic Balloon Catheter.: 1. Should Have Membrane For Improved Abrasion Resistan. 2. Should Have A Small Profile Of7 Fr To 7.5 Fr. 3. Should Be Available In Volume Of 34Cc, 40Cc & 50Cc. 4. Balloon Diameter At 2Psi Should Be 15Mm. 5. Insertable Length Should Not Exed 725Mm. 6. Insertion Kit Should Be Provided Separately. 7. It Should Have Isoapproved. Sizes 34, 40 , 50 Cc Catheter Compatible With Datascope Iabp , Annuloplastyring,Rigidfor Mitral Valve: 1. Constructed Of Titanium Alloy With A Silicone Rubber Sewing Ring. 2. Closed Ring For Stable Remodelling. 3. Restores The Natural Size(3:4) & Shape In Systolic Position Ratio. 4. Marking Sutures For Accurate Plament. 5. Preferable Saddle Shaped. 6.Iso Approved. Sizes : Even No.24Mm To 34Mm. Oddno. 25Mm To35mm. , Annuloplasty Ring, Mitral Valve For Ischemic Mr: ?Rigid Ring For Durable Repair ? Complete Ring For Stable Remodelling ?Asymmetrical Designfor Asymmetrical Dilation P2-P3 Region ?Increased Sewing Ring Margin In P2-P3 Region. ?Dippedp3regiontoaccommodate Stress From Downward Lv Displament ?Iso Approved ? Sizes : Even No.24Mm To 34Mm. ?Odd No. 25Mm To35mm. , Annuloplastyring,Semi Flexible For Mitral Valve: Three Dimensional Design To Suit The Annulus Normal Of The Mitral Valve. Semi Flexible In Nature. Isoapproved. Sizes : Even No.24Mm To 34Mm. Oddno. 25Mm To35mm. , Annuloplasty Ring, Flexible For Mitral Valve: Barium Impregnated Silicone Strip With Polyester Fabric For X-Ray Visibility. Flexible Design To Allow Dynamic Motion . Isoapproved. Sizes : Even No.24Mm To 34Mm. Oddno. 25Mm To35mm. , Annuloplastyringsemirigid With Double Saddle Shape: 1. For The Use Of Mitral Valve Repair 2. It Should Be Semi Rigid Double Saddle Shaped Ring Design Specially For Mitral Position For Helping Stable Remodelling. 3. It Should Havespeciallycraftedsewingcuff Has Visible Ledge That Permits Plament Of Sutures. 4. Iso Approved. 5. Sizes : Even No.24Mm To 40Mm. , Annuloplastyrings3drigid For Tricuspid Valve: Annuloplasty Ring With Three Dimensional Shapes With Incomplete Ring Shape To Avoid The Sensitive Conduction System Anatomy And Downward Angle In Septal Region To Help Redu The Stress On Sutures And The Risk Of Ring Dehisn. Iso Approved Sizes : Even No.24Mm To 34Mm. Oddno. 25Mm To35mm , Annuloplasty Ring, Flexible For Tricuspid Valve: 1. Flexible Design To Allow Dynamic Annular Motion. 2. Open At Annuloseptal Commissure To Avoid Conduction System. 3.Iso Approved , Annuloplastyringsemi Flexible For Tricuspid Valve: 1.Semiflexibledesigntoallowdynamic Annular Motion. 2. Open At Annuloseptal Commissure To Avoid Conduction Syatem. 3.Iso Approved. , Prosthetic Heart Valve Bileaflet Mitral: 1. Bileaflet Pyrolytic Carbon Disc Valve 2. Radioopaque Disc To Be Visualized On X- Ray & Fluoroscopy And Disc Should Be Mri Compatible. 3. Should Be Of Lowprofile& Thromboresistan Characteristics. 4. Opening Angle Should Be 800-900 5. Wide Range Of Sizes For Mitral 23 To 35 Mm. 6. Easy Torque Rotation And Intraoperative Adjustment Should Be Possible. 7. Sewing Cuff Should Contain Suture Marker For Accurate Plament. 8. Valve To Be &Iso Approved. , Prosthetic Heart Valve Bileaflet Aortic & Mitral Valve.: 1. Bileaflet Pyrolytic Carbon Disc Valve 2. Radioopaque Disc To Be Visualized On X- Ray & Fluoroscopy And Disc Should Be Mri Compatible. 3. Should Be Of Low Profile & Thromboresistan Characteristics. 4. Opening Angle Should Be 800-900 5. Wide Range Of Sizes For Aortic 17 To 31 Mm. 6. Easytorquerotationandintraoperative Adjustment Should Be Possible. 7. Sewing Cuff Should Contain Suture Marker For Accurate Plament. 8. Valve To Be &Iso Approved. , Prostheticheartvalvemono Leaflet Mitral & Aortic: 1. It Should Superior Hemodynamic. 2. It Should Be Rotatable Within The Swing Ring. 3. It Should Have Rigid Tilting Disc Single Leaflet Heart Valve. 4. It Should Have In Various Sizes From 17Mm To 25 Mm For Aortic Position And Size 23Mm To 31Mm For Mitral Position. 5. Should Have Approval For Imported Valve. No / Approval Require For Indigenous Made Heart Valve. Indigenous Valve Doesn’T Require /Approval , Prostheticheart Valve Bileaflet Aortic With Conduit: 1. Bileaflet Pyrolytic Carbon Disc Valve 2. Radioopaque Disc To Be Visualized On X- Ray & Fluoroscopy And Disc Should Be Mri Compatible. 3. Should Be Of Low Profile & Thromboresistan Characteristics. 4. Opening Angle Should Be 800-900 5. Wide Range Of Sizes For Aoritc 19 To31 Mm. 6. Easytorquerotationandintra-Operative Adjustment Should Be Possible. 7. Sewing Cuff Should Contain Suture Marker For Accurate Plament. 8. Valve To Be & Approved. 9. Valveshouldbeattachedwithknittedlow Porosity Coated Graft. All Size.Should Have Iso Approved , Low Profile Prostheticheart Valve Bileaflet Aortic: 1. Bileaflet Pyrolytic Carbon Disc Valve 2. Radio-Opaque Disc To Be Visualized On X- Ray & Fluoroscopyanddiscshouldbemri Compatible. 3. Should Be Of Low Profile & Thromboresistan Characteristics. 4. Opening Angle Should Be 800-900 5. Easytorquerotationandintra-Operative Adjustment Should Be Possible. 6. Sewing Cuff Should Contain Suture Marker For Accurate Plament. 7. Valve To Be & Approved. 8. Sewingringshouldbethinnerandmore Pliable 9. Should Provide Extra Eoa Than Standard Valves 10. 17Mm To 23 Mm 11. Should Have Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral: Specification , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Stent–Less Porcine Tissue Aortic Valve): A. All The Sizes Should Be Available B. Should Be In Clinical Use With Long Term Good Results C. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Stent-Less Pericardial Tissue Aortic Valve): A. All The Sizes Should Be Available B. Should Be In Clinical Use With Long Term Good Results C. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Pericardial Stented Tissue Mitral Valve): A. All The Sizes Should Be Available B. Second Generation Valve With Xenologix Treatment C. Should Have Long Term Good Results Available In Literature And More Than 15 Years Durability In Vivo D. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Pericardial Stented Tissue Mitral Valve): A. All The Sizes Should Be Available B. Low Profile Third Generation Valve With Thermafix Fixation C. Should Have Long Term Good Results Available In Literature D. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Pericardial Stented Tissue Aortic Valve): A. All The Sizes Should Be Available B. Second Generation With Xenologix Treatment C. Should Have Long Term Good Results Available In Literature And More Than 15 Years Durability In Vivo D. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Pericardial Stented Tissue Aortic Valve [Low Profile With Grater Eoa]): A. All The Sizes Should Be Available B. Low Profile Third Generation With Thermafix Treatment C. Should Have Long Term Good Results Available In Literature D. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Pericardial Stented Tissue Aortic Valve With Pericardial Covered Stent): A. All The Sizes Should Be Available B. Third Generation Pericardial Stented Valve With Stunts Covered With Pericardium And Treated With Links Technology C. Should Have Good Long Term In Vitro Results Available In Literature. D. Us Andappoved E. Aortic Valve Delivered Larger Eoas, Exllent Hemodynamic With Single- Digit Pressure Gradients F. Elimination Of Tacking Suture At Loupe Of Commissure Redud Risk Of Tearing G. High Strength Titanium Stunts Andquick Click In Handle Attachment , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Porcinebioprostheticlow Profile Mitral And Aortic Valves): A. Second Generation With Anti Calcification Treatment By Linx Technology B. Low Pressure Fixation C. Results Studied In Acss Of More Than 20 Years D. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Porcine Bioprosthetic Low Profile And Aortic Valves): A. Second Generation With Anti Calcification Treatment By Linx Technology B. Low Pressure Fixation C. Results Studied In Acss Of More Than 20 Years D. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Porcinebioprostheticlow Profile Mitral And Aortic Valves): A. Third Generation With Amino- Olic Acid Anti Calcification Treatment With Covalent Bonding With Glutraldehyde . B. Physiologic Pressure Fixation C. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Bovinejugularvein Pulmonary Valve Conduit): (All Sizes ) Isoapproved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Pulmonary Bioprosthesis Conduit): (All Sizes ) Isoapproved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Bovine Pericardium): Pericardium Patch Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Bioprostheticaortic Valve (Suture Less)): Trated Valve To Redu Calcification. Shouls Have Self Expending And Elastic Alloy Stent. Should Have Covered With Film Of Carbofilm For Biocompatibility . Isoapproved , Heart Stabilizing System: 1. Tissue Stabilizing System With Malleable Pods For Better Grip And Anastomosis. 2. It Should Be Compatible With Various Cardiothoracic Retractors. 3. It Should Be Suction Based. 4. Should Be Trislot Design Of Pods For Better Visualization 5. Pods Should Have Low Profile Design For Easy Acss To Any Visibility Of Surgical Field With 1800 C Rotations. 6. It Should Have Iso Certification. , Heart Stabilizing System (Fortheuseofminimal Invasive Cardiac Produre).: 1. It Should Have Low Profile Pods. 2. It Should Have Iso Certification. 3. Suitalbe For Minimally Invasive Cardiac Surgery. , Heart Positioner (Cup Shaped) Archin Variety: 1. Should Be Suction Based. 2. It Should Be Based Low Profile Suction Cup 3. It Should Be Compatible With Various Vogue Cardiothoracic Retractors. 4. It Should Have Low Profile Arm Designed For Better Visualization. 5. It Should Have Iso Certification. , Heart Positioner Starfish Variety: 1. Should Be On Suction Based. 2. It Should Be Based Low Profile 3. It Should Be Compatible With Various Vogue Cardiothoracic Retractors. 4. It Should Have Low Profile Arm Designed For Better Visualization. 5. It Should Have Iso Certification. , Heart Positioner (Fortheuseofminimal Invasive Cardiac Produre).: 1. It Should Be Suction Based 2. It Should Have Low Profile Arm Designed For Better Visualization Micas. 3. It Should Have Iso Certification. , Vascular Graft For Aortic Arch Gelatin / Collagen Coated: 1. It Should Be Coatedwithgelatinor Collagen With Multiple Branches For Arch And Perfusion. 2. Graft Material Should Have Low Porosity Dacron (Fabric) 3. Should Be Provided With Various Sizes 4. It Should Have Iso Certification , Vascular Graft Y Type Gelatin / Collagen Coated: 1. Itshouldbecoatedwithgelatinor Collagen. 2. Graft Material Should Have Low Porosity Dacron (Fabric) 3. Should Be Provided In Sizes Of 16X8mm & 14X7mm. , Vascular Graft Straight Woven: 1. Itshouldbecoatedwithgelatinor Collagen. 2. Graft Material Should Have Low Porosity Dacron (Fabric). 3. Should Be Provided In Various Sizes And Lengths. , Axilo Femoral Ring Graftptfe: 1.Material Should Have Eptfe. 2.It Should Have Rings Forkink Resistan. 3Size-6,7,8Mmx20cm,To 90 Cm , Axilo Femoral Ring Graft Ptfe, Thin Wall.: 1. It Should Be In Various Sizes And Length. 2. Material Should Have Thin Wall Ptfe. 3. It Should Have Rings Forkink Resistan. , Axilo Femoral Ring Graft Ptfe,Thin Wall Coated With Carbon.: 1. It Should Be In Various Sizes And Length. 2. Material Should Have Thin Wall With Carbon Coated Ptfe. 3. It Should Have Rings Forkink Resistan. , Disposable Arrhythmia Ablation Kit: 1. Should Be Based On Radio Frequency 2. It Should Have Separate Pack For Monopolar Pen And Bipolar Devi 3. It Should Have/ Approved , Right Angled Venous Cannula: Singlestagecannulawith90degreeplastictub With Side Holes Size 12-28 Fr , E Ptfesuture Cv0,Cv (2-7) , Fibrin Glue: 2- Polyethylene Glycol Synthetic Sealent 2Ml , Asepto Syringe , Tmouth Piece With Tubing And Chamber: , La Line Central Catheter Size 7.5 Fr Length , Teflon Felt Size 2”*2” , E-Ptfecardiovascularpatch (10*5*0.6) , Double Pressure Transdur: 2 Disposable Pressure Transdur With 2 Flush Devis With Stop Cock With 48”+12” Pressure Tubings