| Sl. No. | Item Description |
| 1 | M&L for taking downStar Delta Starterfrom existing HVAC panel, supply, installation, testing of star delta starter, three phase 415 volt suitable for 15 HP motor having the following accessories including necessary modification work complete all as specified and directed:-(a) Power Contactor 22 A TP 220 V AC (Main & Delta) - 02 Nos.(b) Power Contactor 18 A TP 220 V AC (Star) - 01 No.(c) Bi Metal Over Load relay 9-15 A - 01 No.(d) Star Delta Timer micon series - 01 No.(e) Digital Multi Function Meter (V+A+F)96 X 96 mm 3 Phase- 01 No.(f) CT 60/5A CL 1 tape wound - 03 Nos.(g) Auto Manual Selector switch 6A 1 P - 01 No.(h) Single Phasing Preventer - 01 No.(i) Push button Start/Stop with Elements 220 VAC - 02 Nos, (j) On, Off, Trip indicating Lights LED type 220 V AC- 1 Set. (Set of three).(k) Aux. Blocks 1 No+1 Nc - 1 Set.(l) Outgoing Terminals - 1 Set.Make of Starter accessories:-L&T/ ABB/Legrand / Schneider/Trinity/AE. |
| 2 | M&L taking down old unserviceable Star Delta Starterfrom existing HVAC panel, supply, installation, testing of star delta starter three phase 415 volt suitable for 20 HP motor having the following accessories including necessary modification workcomplete all as specified and directed:- (a) Power Contactor 25 A TP 220 V AC (Main & Delta) - 02 Nos.(b) Power Contactor 22 A TP 220 V AC (Star) - 01 No.(c) Bi Metal Over Load relay 14-23 A - 01 No.(d) Star Delta Timer micon series - 01 No.(e) Digital Multi Function Meter (V+A+F)96 X 96 mm 3 Phase- 01 No.(f) CT 100/5A CL 1 tape wound - 03 Nos.(g) Auto Manual Selector switch 6A 1 P - 01 No.(h) Single Phasing Preventer - 01 No.(i) Push button Start/Stop with Elements 220 VAC - 02 Nos, (j) On, Off, Trip indicating Lights LED type 220 V AC- 1 Set. (Set of three).(k) Aux. Blocks 1 No+1 Nc - 1 Set.(l) Outgoing Terminals - 1 Set.Make of Starter accessories:-L&T/ ABB/Legrand / Schneider/Trinity/AE. |
| 3 | Supply, fixing and neccessary modification of MCCB 4 Pole 100 Amps 25 KA capacity 415V AC 50Hz with adjustable thermal and Adjustable magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable MCCBs complete all as specified and directed. |
| 4 | Supply, fixing and modification from SFU to MCCB 4 Pole 400 Amps 36 KA capacity 4 Pole 415V AC 50Hz with adjustable thermal and Adjustable magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable MCCBs complete all as specified and directed. |
| 5 | M&L in replacement of aluminium bus bar suiable for incomingand outgoing provision for main incommer to outgoing MCCBsas per requirement with necessary modification work dulycolured insulated head shrinkable sleevs RYBNall as specified and directed. |
| 6 | Taking downLT Incoming and outgoing cables from existing HVAC panel (for repair and modification work of panel) after completing panel repair work reconnecting thecables on same position with replacement of old cable glands, thimbles, lugs as per existing size or ground requirement complete all as specified anddirected. |
| 7 | M&L replacement of LT cable glands up to 300 Sq mm LT cablefor incoming and outgoing cables for HVAC indoor panel (4x110 TR) all as specified and directed. |
| 8 | M&L replacement of various size oflugs up to 300 Sq mm LT cablefor incoming and outgoing cable connectionfor HVAC indoor panel (4X110TR) all as specified and directed. |
| 9 | M&L for repair/ servicingof main HVACLT panel boardindoor type of old AC plant of capacity (4x110 TR)cleaning with compressed air,repair to PCC foundation as required at sitescrubbing out old paint, rust etc from LT Panel, making smooth and even surface then modification of internalcampartment forfixing new controls and accessories with replacement of internal wiringconnection, cable entries, fixing offront & back sidebroken door hinges, locking arrangement, painting with one coat of anti rust paint and two coats ofsuperior quality synthetic enamel paint on entire Enclosure of panel (outer/ inner side of panel ) all as specified and directed.(Note- Replacement of internal accessories viz, ACBs/ MCCBs, contactor, starter, relay, timer cable glands,bus bar, lugs, thimblesspares will be measured separately item of BOQ) |
| 10 | Supply, installation, testing and commissioning of factory made Control Desk Panel Indoor type, platform mounted of suitable Size, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system, dust and vermin proof, protection class (IP-54) and made of 2.00 mm thick CRCA Sheet with suitable frame work/ support, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm including taking down existing unserviceable Control desk complete all as specified and directed. The scope of work also comprising of the following accessories:- (a) Modular Push button Start/Stop with Elements 240 V AC 22.5 mm - 30 Set, (b) Indicating Lights LED type ON/OFF 240 V AC 22.5 mm- 30 Set. Make of Indicating Lights & Push Button:- L&T/ABB/Schneider/Vaishno.Make of Control Desk Panel:- Adlec/ Schneider / Universal Switch Gear Control/ Tricolite. |
| 11 | Supply and laying in replacement LT power cable copper6 core 1.5 Sqmm (ISI mark) through wall/roof/floorforfixingall as specified and directed. |
| 12 | Supply and fixing in repairs MS channel pre-galvanized 250 X 50 mm perforated cable trayfixed on wall/ceilingfor cable duly supported with MS angle of size 50 x50 mmincluding welding all as specified & directed by Engr-in-Charge. |
| 13 | M&L in replacement of volt meter (0 to 500 volts) digital type, three phase of size 96mm x 96mm (as per sample) complete all as specified & directed. |
| 14 | M&L in replacement of Amp meter (0 to 300 amps) digital type, three phase of size 96mm x 96mm(as per sample) complete all as specified & directed. |
| 15 | M&L in replacement ofIndicator lamp, LED type(as per sample) complete all as specified & directed. |
| 16 | Supply and replacement of lead acid 12 volt 180 AH battery maintenance freeincluding terminals all as specified & directed.(Make- Excide/Luminous/Amaron or equivelent approved make) |
| 17 | Supply and fixing in in replacement ofelectricallyopearated sliding gate motor single phase230 volt AC of operatingcapacity 2500 Kg weightforautomatic/mannualmode including necessery modification for fixing/ fittings all as specified and directed. |
| 18 | Supply, installation, testing and commissioning in repair/ replacement ofoutdoor LT panel board fixed on angle iron frame of 50x50x5mm(thick)double door opening with locking arrangment,including necessary incoming & outgoing cable connections, cable glands, thimbles of required sizes working on 440 Volt 3 phase, 50 HZ, AC supplysuitablealuminium bus bar fully compartmentalised mounted on epoxy insulator, dust proof and vermin proof 3.15 mm thick CRCA sheet steel enclosure powder coatedand all as specified CPRI Approved and having the following items:- (Location: Near Submersible pump) |
| 19 | Incoming:- (a) One No MCCB 100 Amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz with microprocessor release (S1 type) adjustable between 40% to 100% against overload setting.(b) BUS BAR:- 4 Nos (three for phase of rating 200Amp and one for neutral of rating 100 Amps made of aluminium mounted on heavy duty rubberised/ porcelain support. |
| 20 | Outgoing:- (ii) MCCB 63 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 Nos.(submersible starter)(iii) MCCB 32 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 No. (post light)(iv) Soft starter for 5 HP pump set-01 (v) soft stater for 3 HP pump set -01 |
| 21 | METERING(a) Voltmeter upto (0-500 volt) digital type with selector switch -01 Set(b) Ameter 0-300 A Digital type with reincast CT set of 3 & with in builtphase selection- 01 Nos.(c) Indicator lamp LED type (set of three) -01 set |
| 22 | All as per item No 18 here in before but panel No. 2 (Location: near ITBP Post No 2) with and including following accessories:- |
| 23 | Incoming:- (a) One No MCCB 160 Amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz with microprocessor release (S1 type) adjustable between 40% to 100% against overload setting.(b) BUS BAR:- 4 Nos (three for phase of rating 300 Amp and one for neutral of rating 160 Amps made of aluminium mounted on heavy duty rubberised/ porcelain support. |
| 24 | Outgoing:- (i) MCCB 100 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 Nos. (For submersible panel)(ii) MCCB 63 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 04 Nos.(ITBP mess, store, pump panel & single accn area)(iii) MCCB 32 amp,double pole- 04 No.(post No 3, 4, 5 & 6) |
| 25 | METERING(a) Voltmeter upto (0-500 volt) digital type with selector switch - 01 Set(b) Ameter 0-300 A Digital type with reincast CT set of 3 & with in builtphase selection- 01 Nos(c) Indicator lamp LED type (set of three) - 01 set |
| 26 | All as per item No 18 here in before but panel No. 3 - (Location: near Car Parking / Post No-2) with and including following accessories:- |
| 27 | Incoming:- (a) One No MCCB 100 Amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz with microprocessor release (S1 type) adjustable between 40% to 100% against overload setting.(b) BUS BAR:- 4 Nos (three for phase of rating 200 Amp and one for neutral of rating 100 Amps made of aluminium mounted on heavy duty rubberised/ porcelain support. |
| 28 | Outgoing:-(i) MCCB 63 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 Nos. (main gate reception)(ii) MCCB 32 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 No.(post No-2 & street light)(iii) MCCB 32 amp,double pole- 04 No. (post security lights) |
| 29 | METERING(a) Voltmeter upto (0-500 volt) digital type with selector switch -01 Set(b) Ameter 0-300 A Digital type with reincast CT set of 3 & with in builtphase selection- 01 Nos(c) Indicator lamp LED type (set of three) -01 setStreet light Auto ON/OFF system(i) Time switch 415 volts, 3 phase of 32 Amp rating- 01 No.(ii) Contactor 3 plole 415 volt, 32 Amp - 01 No.(iii) MCB SP 16 Amp 10 KA - 02 Nos(iv) Toggle switch 16 Amps - 01 No(v)Neutral link copper - 01 No. |
| 30 | All as per item No 18 here in before but panel No.-4 (Location: near old bldg front) with and including following accessories:- |
| 31 | Incoming:- (a) One No MCCB 250 Amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz with microprocessor release (S1 type) adjustable between 40% to 100% against overload setting.(b) BUS BAR:- 4 Nos (three for phase of rating 400 Amp and one for neutral of rating 250 Amps made of aluminium mounted on heavy duty rubberised/ porcelain support. |
| 32 | Outgoing:-(i) MCCB 100 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 Nos.(old bldg DBs)(iii) MCCB 32 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 No.(bldgs) (iv) MCCB 32 amp,double pole- 04 No. (bldg security lights) |
| 33 | METERING(a) Voltmeter upto (0-500 volt) digital type with selector switch -01 Set(b) Ameter 0-300 A Digital type with reincast CT set of 3 & with in builtphase selection- 01 No.(c) Indicator lamp LED type (set of three) -01 set |
| 34 | All as per item No 18 here in before but panel No.-5 (Location: near old bldg front/ UPS ) with and including following accessories:- |
| 35 | Incoming:- (a) One No MCCB 250 Amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz with microprocessor release (S1 type) adjustable between 40% to 100% against overload setting.(b) BUS BAR:- 4 Nos (three for phase of rating 400 Amp and one for neutral of rating 250 Amps made of aluminium mounted on heavy duty rubberised/ porcelain support. |
| 36 | Outgoing:-(i) MCCB 100 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 Nos.(old bldg DBs)(ii) MCCB 63 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 Nos.(Guard rooms and Post No-1))(iii) MCCB 32 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 01 No. (fountain panel) (iv) MCCB 32 amp,double pole- 04 No. (bldg security lights) |
| 37 | METERING(a) Voltmeter upto (0-500 volt) digital type with selector switch -01 Set(b) Ameter 0-300 A Digital type with reincast CT set of 3 & with in builtphase selection- 01 no.(c) Indicator lamp LED type (set of three) -01 set |
| 38 | All as per item No 18 here in before but panel No.- 6(Location: Near post No 07) with and including following accessories:- |
| 39 | Incoming:- (a) One No MCCB 160Amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz with microprocessor release (S1 type) adjustable between 40% to 100% against overload setting.- 01 (b) BUS BAR:- 4 Nos (three for phase of rating 300 Amp and one for neutral of rating 160 Amps made of aluminium mounted on heavy duty rubberised/ porcelain support. |
| 40 | Outgoing:-(ii) MCCB 100 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 01 Nos. (Old sub stn)(iii) MCCB 63 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 03 No. (Post 7 , 8 &street light)(iv) MCB DP 32 Amps-04 Nos (bldg security light) |
| 41 | METERING(a) Voltmeter upto (0-500 volt) digital type with selector switch -01 Set(b) Ameter 0-300 A Digital type with reincast CT set of 3 & with in builtphase selection- 01 no.(c) Indicator lamp LED type (set of three) -01 setStreet light Auto ON/OFF system(i) Time switch 415 volts, 3 phase of 32 Amp rating- 01 No.(ii) Contactor 3 plole 415 volt, 32 Amp - 01 No.(iii) MCB SP 16 Amp 10 KA - 02 Nos(iv) Toggle switch 16 Amps - 01 No(v) Neutral link copper - 01 No. |
| 42 | All as per item No 18 here in before but panel No.- 7 (Location: near post No-9)with and including following accessories:- |
| 43 | Incoming:- (a) One No MCCB 160 Amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz with microprocessor release (S1 type) adjustable between 40% to 100% against overload setting.(b) BUS BAR:- 4 Nos (three for phase of rating 300 Amp and one for neutral of rating 160 Amps made of aluminium mounted on heavy duty rubberised/ porcelain support. |
| 44 | Outgoing:- (iii) MCCB 63 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 Nos.(s/pump panel &post No-09)(iv) MCCB 32 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 01 No.(Fire sub stn)(v) Soft starter for 7.5 HP pump set - 01 |
| 45 | METERING(a) Voltmeter upto (0-500 volt) digital type with selector switch -01 Set(b) Ameter 0-300 A Digital type with reincast CT set of 3 & with in builtphase selection- 01 no.(c) Indicator lamp LED type (set of three) -01 setStreet light Auto ON/OFF system(i) Time switch 415 volts, 3 phase of 32 Amp rating- 01 No.(ii) Contactor 3 plole 415 volt, 32 Amp - 01 No.(iii) MCB SP 16 Amp 10 KA - 02 Nos(iv) Toggle switch 16 Amps - 01 No.(v)Neutral link copper - 01 No. |
| 46 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below the ground level connected to GI strip 32 x 6mm by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 15 mm bore light grade for protection of earthing wire PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, watering pipe 20mm bore light grade,funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR part-I and including excavation & earth work & connecting the earthing point/equipment and testing complete all as specified & directed. |
| 47 | M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required32x6mm galvanised iron strip complete all as specified & directed. |
| 48 | M&L for in replacement for LED street/security light fitting 250 Watt230 V energy saving & enviornmental friendly, long lifediecast aluminium, IP66, with high power LED as light source incl necessary fixing arrangement with clamps of suitable size and connectionusing 1.5 Sqmm PVC insulated copper cable complete all as directed (Make- Havells Cat part No.JETAIRISALPHAFL250WLED757APLTG or equivelent as approved) |
| 49 | M&L for in replacement for LED Flood Light luminaire 300 Watt 230 Volt energy saving & enviornmental friendly, long lifediecast aluminium, IP66, with high power LED as light source incl necessary fixing arrangement with clamps of suitable size and connectionusing 1.5 Sqmm PVC insulated copper cable complete all as directed. (Make- Havells cat part No JETAIRISALPHAFL300WLED757PLTG orequivelant as approved) |
| 50 | M&L for in replacement for LED Flood Light luminaire 500 Watt230 volt energy saving & enviornmental friendly, long lifediecast aluminium, IP66, with high power LED as light source incl necessary fixing arrangement with clamps of suitable size and connectionusing 1.5 Sqmm PVC insulated copper cable complete all as directed (Make :Havells cat part No JETAVALOURLEFL500W4MLED757PINTMBLTGor equivelant as approved) |
| 51 | M&L for repair and servicing ofLT cable connection of size 150 Sq mm to 300 Sq mm 3.5 coreby disconnecting fromexisting panel board,cleaning of unserviceable/ burntcable terminals, fixingof newcable joint in existing cable with replacement of nut bolt and accessories required for refixing in existing position, reconnecting, testing all as specified andas directed. |
| 52 | M&L for replacement of chequered plate 5/6mm thick of required size with two moving handles for cable duct cover as required at site incl cutting & welding, painted with two coats of synthetic enamel paint over acoat of red oxide primer completeall as specified & directed. |
| 53 | M&L for (in repair) cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm complete all as specified & directed. |
| 54 | S&F (in replacement) bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length, bent to shape, fixed on pole/wall with and including MS 50x5mm FI clamps( 02 Nos) with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed. |
| 55 | S & F in replacement of industrial type exhaust fan round shapeFRP body of size 900 mm 3 phase, 415 Volt AC axial fan with 1 HP induction motorcopper winding, with aluminium blade of2800RPM complete with louvers/ shutter including necessary fixing arrangement in existing wallcomplete all as specified & directed. |
| 56 | Excavation in trenches n.exc 1.5 m wide and not exc 1.5 m depth and getting out in soft and loose soil complete all as specified and directed. |
| 57 | Returning and filling in of excavated material any type including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed. |
| 58 | Removal of surplus excavated material of any type not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 59 | M&L for Sand cushioning/sand coveringfor underground cable protection complete all as specified.Note: Punned thickness only will be measured and paid. |
| 60 | Supply and laying sub class \"B\" bricks of old size (approved size locally available) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engr-in-Charge. |
| 61 | Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable forXLPEinsulated armoured heavy duty aluminium conductor 1100 Volts grade Cable 3.5/4 core 16 Sqmm to 35 Sqmm size complete all as specified & directed. |
| 62 | Supply, fixing and testing end termination jointjoint coldt shrinkable type with jointing kit suitable forXLPEinsulated armoured heavy duty aluminium conductor 1100 Volts grade Cable 3.5/4 core 25 Sqmm- 50 Sqmm size complete all as specified & directed. |
| 63 | Supply, fixing and testing end termination jointjoint coldt shrinkable type with jointing kit suitable forXLPEinsulated armoured heavy duty aluminium conductor 1100 Volts grade Cable 3.5/4 core 25 Sqmm- 120 to 185 Sqmm Sqmm size complete all as specified & directed. |
| 64 | Taking down defectivestreet light fitting of any size, type and capacity from height of pole / walls / high mast of any location exceeding 7.0 m height for repair work, re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed:-Note: (a) The M/L forItems like ballast, lamp, igniters, capacitors, electronicdrivers, surge protection devices etcshall be measured and paid separately under relevant items of BOQ. (b) The quoted rate shall deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site, necessary tools like ladders & other T&P as required which shall be arranged by the Contractor. (c) The components toLED panel is not included in the items which shall be measured and paid for separately under respective item of BOQ. |
| 65 | Supply & Fixing in repair the following spares suitable for street light/flood light/post top lantern light fittings:- |
| 66 | Electronic driver suitable for 200 to 250 W LED light fitting. |
| 67 | Electronic driver suitable for 100 to 150 W LED light fitting. |
| 68 | Electronic driver suitable for 70 to 90 W LED light fitting. |
| 69 | Electronic driver suitable for 40 to 50 W LED light fitting. |
| 70 | S&F in repair Surge protection device of capacity 10 KV suitable for LED light fitting. |
| 71 | Taking down old unserviceable street light fittings from any height and Supply & fixing LED street light 100 W fittings comprising of epoxNew generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminum housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK08 with ingress protection IP 65/66 and SPD of capacity 10 KV including necessary clamps etc completeand testing on completion all as specified and as directed.(Make: Havells ENDURAPEARLPLUSSL100WLED757PASYTOPCLC or equivalent to Philips/ Bajaj/ Wipro/ GE/ CG ). |
| 72 | Taking down old unserviceable street light fittings from any height and Supply & fixing LED street light 70 watt fittings comprisingNew generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover havingTOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. and testing on completion all as specified and as directed.(Make: Havells ENDURAOMNIPLUSSL70WLED757SASYTOPC or equivalent to / Philips/ Bajaj/ Wipro/ GE/ CG). |
| 73 | Dismantling old unserviceable flood light fittings from any position exceeding 16.0 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frameLED 200w type with ingress protection IP 66 ingress protection 4kv in built and and surge protection device of 10 KV capacity, cct 5700K etc including necessary angle iron supports duly painted in two coats over a coat of primer, clamps, nuts and bolts etc completeand testing on completion all as specified and as directed(Make: Havells/Philips/Baja cat part no PRAZE F 240L WH NB A5 TG SDOR equivalent in /Wipro/GE/CG). |
| 74 | Dismantling old unserviceable flood light fittings from any position exceeding 16.0 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frameLED 400w type with ingress protection IP 66 ingress protection 4kv in built and and surge protection device of 10 KV capacity, cct 5700K etc including necessary angle iron supports duly painted in two coats over a coat of primer , clamps, nuts and bolts etc completeand testing on completion all as specified and as directed(Make: Havells/Philips/Baja cat part no PRAZE F 360L WH NB A5 TG SDOR equivalent in /Wipro/GE/CG). |
| 75 | S&F in repair PVC insulated 3 core 1.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting,testing and commissioning complete all as specified & directed. |
| 76 | S&F in repair PVC (thermo plastic) street light junction box heavy duty with locking arrangement 3 phase aluminium bus bar incl 02 Nos PVC conduit upto the height of top most level of coping of pole from GL alongwith necessary MS clamp, nut bolts and washers for fixing and 01 No MCB single pole 240 V 6-32 Amps complete all as specified & directed. |
| 77 | M&L for preparation of old painted steel surfaces of 9 m long steel poles, removing oily/ greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and writing pole details with 125 mm dia adhesive sticker with white letters on blackground (as per sample) etc complete all as specified & directed. |
| 78 | M&L for fixing in repair adhesive sticker radium type red coloured water resistant of approx 2 inches width around the circumference of pole (as per sample) at a approx height of two meters all as directed. |
| 79 | M&L for repairs to motor of Capacity 1.0 HP/0.75 KW 415 Volts 50 Hz 3 Phase 930 RPM and necessary rewinding with super enamelled copper wire all as per existing and servicing/ greasing of reduction gear box of high mast/ mid mast pole complete all as specified and directed. |
| 80 | M&L for repair/ maint of the control panel of High mast/Mid mast and replacement of all unserviceable parts such as contactors/timers etc complete including painting with a coat of synthetic enamel paint. |
| 81 | M&L for repairs to High Mast/mid mast of 12.5 m to 16 m height lantern carriage/winch, checking for movement, inspecting the alignment, replacement of broken/defective SS wire rope of size 6 mm 7/19 construction complete, replacement of 5 core 2.5 Sqmm flexible copper conductor, ERP insulated PCP/PVC sheathed trailing cable complete, testing & commissioning complete all as directed by Engr-in-Charge. |
| 82 | S&F in repair PVC insulated 6 core 2.5 Sq mm copper conductor cable for connecting highmast light fittingtesting and commissioning all as directed. (Make: Plaza/ Gloster/Polycab/Havells). |
| 83 | Supplying and fixing in repair high bay light 200 Watt Havells cat part no BRITESAUCERHBP200WLED757NBTOLTG |
| 84 | Labour only for taking out and relaying/ re-routing old/existing PVC/XLPE armoured aluminium conductor cable after repair complete of following sizes:- (Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid seperately under respective item of BOQ) |
| 85 | Upto size 25 sqmm 2/3.5/4 Core |
| 86 | Size 35 sqmm to 70 Sqmm 3.5 Core |
| 87 | Size 95 sqmm to 150 sqmm 3.5 core |
| 88 | Size 185 sqmm to 400 sqmm 3.5 core |
| 89 | Checking & locating of fault in underground HT/ LT cable of any size by cable fault locator machine complete all as directed. |
| 90 | Dismantling & taking out HT/LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/in trenches/along pole/ panel/feeder pillar box, complete. |
| 91 | M&L for (in replacement) for GI tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete for following sizes:- |
| 92 | 40 mm bore |
| 93 | 50 mm bore |
| 94 | 100 mm bore |
| 95 | Supply & lay testing & commissioning of Jaking out, dismantling & removing of unserviceable cable and (or passing through pipe or in cable ducts),heavy duty XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size and making electric connection with aluminium lugs complete all as specified & directed.(Note :- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid seperately under respective item of BOQ):- |
| 96 | 10 Sqmm 2 core |
| 97 | 16 sqmm 3 core |
| 98 | 16 Sqmm 4 core |
| 99 | 25 Sqmm 3.5 core |
| 100 | 35 Sqmm 3.5 core |
| 101 | 50 sqmm 3.5 core |
| 102 | 70 sqmm 3.5 core |
| 103 | 95 sqmm 3.5 core |
| 104 | 120 sqmm 3.5 core |
| 105 | 185 sqmm 3.5 core |
| 106 | M&L for making hole below the road by drilling machine or hand drill without damaging road for inserting pipe upto 100 mm dia complete all as specified and directed. (Note: GI/CI/DI/MS pipe shall be measured & paid separately) |
| 107 | Dismantling & taking out defective LT PVC/ XLPE cable from trenches including excavation and earth work, cutting and removing defective parts and supply and fixing straight through joint heat shrink kit complete including jointing material and making connection of LT cables for the following sizes:- |
| 108 | 25 sqmm 3.5 core to 50 sqmm, 3.5 core |
| 109 | 70 sqmm 3.5 core to 120 sqmm, 3.5 core |
| 110 | 150 sqmm 3.5 core to 400 sqmm 3.5 core |
| 111 | M&L for replacement of door/ MS sheet 2 mm/ 3 mm thick as per old/ existing LT panel board of panel of any size with cutting, welding, bend to shape and spray painting with synthetic enamel paint smoke grey paint over a primer coat in outer/ inner side of electric panel board complete all as directed. |
| 112 | M&L for replacement of lock assembly with key of existing LT panel board/feeder piller (any type/ size) complete all as directed. |
| 113 | M&L for repair/overhauling of old LT panel board of any size/type, cleaning with compressed air, tightening of all electric connections to bus bar & switchgears, replacement of wornout lugs, nut, bolts, proper connection to main earth lead, glands to be provided/replaced as required at cable entries, fixing of door front & back side with proper locking arrangement, repair to PCC foundation as required at site and spray painting with synthetic enamel smoke grey paint in outer/inner side of panel after cleaning andpreparing surface incl sign writing complete all as directed. |
| 114 | S&F (in replacement) following items in the existing panel / location and connection with using aluminum lugs incl making necessary alteration in panel/door as required for proper fixing & connection complete all as specified and directed:-Note: (i) MCCB shall be properly fited in existing compartmentand operating handle of MCCB shall be proper in opening existing cover/door of compartment of LT panel board.(ii) Make of MCCB/MCB/Contactor - Schneider/ABB/L&T/Legrand or as existing make. |
| 115 | MCB 4 pole 63 amps, 10 KA breaking capacity, B\"\" Series, 415 Volt |
| 116 | MCB 4 pole 100 amps, 10 KA breaking capacity, B\"\" Series, 415 Volt |
| 117 | MCCB 3 pole 63 amps, 16 KA breaking capacity, 415 Volt |
| 118 | MCCB 3 Pole 100 amps, 16 KA breaking capacity, 415 Volt |
| 119 | MCCB 3 Pole 125 amps, 25 KA breaking capacity, 415 Volt |
| 120 | MCCB 3 Pole 200 amps, 35/36 KA breaking capacity, 415 Volt |
| 121 | MCCB 4 Pole 200 amps, 35/36 KA breaking capacity, 415 Volt |
| 122 | MCCB 3 Pole 250 amps, 35/36 KA breaking capacity, 415 Volt |
| 123 | MCCB 4 Pole 250 amps, 35/36 KA breaking capacity, 415 Volt |
| 124 | MCCB 3 Pole 400 amps, 35/36 KA breaking capacity, 415 Volt |
| 125 | MCCB 4 Pole 630 amps, 36/50 KA breaking capacity, 415 Volt |
| 126 | Volt meter (0 to 500 volts) digital type, three phase of size 96mm x 96mm |
| 127 | Amp meter (0 to 300 amps) digital type, three phase of size 96mm x 96mm |
| 128 | Indicator lamp, LED type |
| 129 | Multifunction Meter, digital type, three phase, size 80mm x 80mm, accuracy class 1.0 for monitoring of various electric parameters such as voltage, current, wattage, frequency, power factor etc. (Make : Schneider model No EM 6436H or equivalent in L&T/Siemens) |
| 130 | M&L for Providing PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) for foundatio, footings, coping of electric poles, plinth block/ Collar etc including necessary form work complete all as specified & directed. |