Tender For Construction Of Various Works Under Package No. 01//Rsrtc-Tonk/2024-25/Distt. Tonk - 1 1-Renovation and Improvement Passenger Ammenties at Bus Stand Tonk 2 Clearing and Grubbing Road Land. (Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.)By Manual Means:- In area of light jungle 3 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soil 4 Supply and Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand 5 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 6 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 7 Randum Rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30cm thick walls in:Cement Mortar 1:6 (1 Cement : 6 Sand) 8 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand) 9 Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75Cement mortar 1:4 ( 1 cement :4 coarse sand) 10 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix 12 Providing and Laying in position specified gradeof cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints and cost of plastizers (ifrequired) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes upto 15, landings, balconies, shelves, chajjas, linteds, bands, plain windows sills, staircases, and spiral starcases etc.M-20 grade Nominal mix/ design mix 13 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 14 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation, footings, straps beams, raft,bases of columns etc. 15 Centering and shuttering with plywood or steel sheets including struting, propping, bracing both ways with steel props and removal of form work for up to five level for:Columns, pillars, posts and struts etc. 16 Centering and shuttering with plywood or steel sheets including struting, propping, bracing both ways with steel props and removal of form work for up to five level for:Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, copings, bed plates, anchor blocks, sills, chajjas, lintels, beams, plinth beam etc. 17 Providing and fabricating reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding(including cost of binding wire) all complete up to floor five level.Hot rolled deformed bars (IS : 1139). 18 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :12mm thick . 19 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 20 6 mm thick cement plaster to ceiling of mix 1:3 (1cement :3 - fine sand) 21 P & F 1st quality vitrified porcelain polished tiles on floor, skirting and steps etc. in different sizes (thickness to be specified by manufacture) with water absortion less than 0.08% and conformatingto IS 15622 of approved make in all colour and shade. laid with 20mm thick cm 1:4 including grounting the joints with white cement and matching pigment etc complete. size 600mm X 600 mm 22 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 23 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 24 Providing and fixing Granite stone slab mirror polished and machine edge cut in Walls, Pillars, Steps, Shelves, Sills, Counters. Floors etc. 15-18 mmthick laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing Complete.Green/Black 3601Cm^2 slab 25 Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. Complete as per design approved by Engineer-in-charge.Granite work 26 Providing and fixing in CM 1 : 4 double paitam (rebated) stone door window and ventilator frames of approved quarry: size 125x100 27 providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure A : 30 mm thick Decorative teak veneer both side. Brass fittings 28 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 29 Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: 20 mm 30 Providing and fixing of uPVC Sliding windows manufactured in ISO 9001:2000 & 14001:2004certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 80 x 52mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. Frame shall have three trackconfiguration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. 31 Shutter :The shutter of sliding window shall be made of 54 x 38mm Extruded 3 box multi-chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.25mm (+/- 0.2mm) provided with reinforcement of 1.2mm thick G/J/U/O TYPE GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 20.5 x 16mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass. Mesh shutter (optional) shall be made of 52 x 21.5mm Extruded 3 box multi-chamber uPVC Window Profile Section of white colour having outer wall thickness of 2mm (+/- 0.2mm) provided with reinforcement of 1.2mm thick U TYPE GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. 32 All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Each sliding shutter is to be fixed with frame on two pullys/rollers and Locking of windows is provided with push lock (touch-lock) of powder-coated white finish. Necessary wind-breaking block, rubber buffer blocks are to be provided in windows for prevention / buffering the collisionbetween window frame and shutter when sliding. Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & 33 width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge.With mesh shutter 34 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). 35 For fixed portionPolyester Powder coating aluminum( minimum thickness of powder coating 50 micron) 36 For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Polyester Powder coating aluminum( minimum thickness of powder coating 50 micron) 37 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) 38 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S.With brass cover plate 39 Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.Polyester Powder coating aluminum( minimum thickness of powder coating 50 micron) 40 Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 41 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 42 Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 43 Providing and fixing steel gate, grating ,and grils made of angles, tees, square bars, flats ,or black pipe with holdfastand fittings complete as per design anddrawing including cutting welding and fabrication with priming coat of red oxide 44 Extra if square, rectangular hollow tublar sections are used or grills made by flats only 45 Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). 46 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 47 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work. 48 Grading roof for water proofing treatment withwater proffing compound Cement mortar 1:3 (1 cement : 3 coarse sand) Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 49 Providing gola 75mm x 75mm in cement concrete 1:2:4 (1 cement : 2 coarsd sand : 4 stone aggregate 10 mm and down gauge) including finished with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design. 50 Making grooves as per design in plaster 10mm to 20mm wide. 51 Providing and fixing factory made of uPVC Extruded section having an overall dimension as below (tolerance+/-1mm) with wall thickness 2.0mm+/-0.2mm,corners of the door frame to be mitred and welded of plastic ,galvanized brackets and stain less steel screws.The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19x19mm and 1mm+/-0.1mm wall thickness and 3 nos.stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge.Extruded section profile size 42x50 mm 52 Providing and fixing to existing door frames 24mm thick factory made PVC door shutters made of stiles and rails of a uPVC hollow section of size 59 x 24 mm and wall thickenss 2mm, +/-0.2 mm with inbuilt edging on both sides. The stiles and rails mitred and jointed at the corners by means of M.S. galvanized / plastic brackets of size75x220mm having wall thickness 1.0mm +/-0.1mm and stainless steel screws. The stiles of the shutter reinforced by inserting galvanized M.S.tube of size 20x20mm and 1mm +/-0.1mm wallthickness. The lock rail made up of H section a uPVC hollow section of size 100x24mm and 2mm +/-0.2mm wall thickness fixed to the shutter stiles by means of plastic / galvanized M.S. U cleats. The shutter frame fitted with a uPVC mult-shambered single panel of size not less than 610mm having overall thickness of 20mm amd 1mm +/-0.1mm wall thickness. the panels fittedvertically and tie bar at two place by inserting horizontally 6mm galvanized M.S. rod and fastened with nuts and washers, complete as per manufactures specification and direction of engineer-in-charge (for W.C. and bathroom door shutter.) 53 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mm and 10 mm thick as per approved design 54 Lettering with black Japan paint of approved brand and manufacture. 55 Cutting of construction joint/ longitudinal joint 4 to 6 mm. wideusing mechanical concrete cutter including cost of diamond bit cutting wheel and filling of bitumen sealingcompound in groove including cost of sealing compound. 75 mm depth 56 Providing and laying granular sub-base material having P.I. notmore than 6 including spreading in layers not exceeding 150 mm compactedthickness andconsolidationby8-10tonnepower rollerto required camber and grade including cost of water and hire charges of machinery including T&P with all lead (Compacted thickness to be measured).asper MoRTHspecification table 400-1, 400-2, For grading-III with CBR value not less than 20.to attain 100%proctor density. 57 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor:Size 580x440mm. 58 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 59 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 60 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS : 1703 mark) complete including cutting and making good the wall:WVC for symphonic EWC. 61 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (large) or half stall size 610x400x80mm 62 P&F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm.Makrana `Adanga` or Raj Nagar 1St Quality White or Andhi Indo-Italian marble. 63 P & F W.V.C. Half-Round Channel of approved makeinC.M.1:3, joints finished in white cement of: Size 100mm dia. 64 P&F C.P.brass Urinal Flush Pipe set complete with flanged brackets of approved make. For 1 Urinal 65 P & F C.P. brass Urinal Spreader for stall urinal of approved make. 66 P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (IS : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make,25 mm G.I. waste pipe complete including cutting & making good the wall.: 67 Size 610 mm x 510 mm 68 Size 630 mm x 500 mm dia for counter top 69 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make (Atul, Modi Guard, Saint Gobin or equivalent) complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4mm thick 70 Glass Shelf with edges rounded off Anodised Aluminium angle frame & C.P. brass brackets & guard rail size 600x120mm 71 P & F Towel Rail or Ring of approved quality/make: 72 C.P. brass Towel Rail elbow type with concealed screws size 450mm (Heavy duty). 73 C.P. Brass Towel Ring revolving type 74 P & F Grating of approved quality/make:Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 75 P & F Liquid Soap Container with brackets complete of approved make:C.P. brass 76 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 77 Making connection of G.I. distribution branch with G.I. main including all fitting.Upto 25mm dia 78 P & F 15 mm. Dia Connection Pipe of approved quality/make :PVC pipe with C.P. Brass nuts upto length, 450mm 79 P & F FlushCock / FlushValve (IS :9758Mark)forWC ofapproved quality make : CP brass push type 20 mm nominal bore. 80 P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete : Brass wt.1000 gm, 25mm. 81 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : 82 Gun-metal 15 mm nominal bore. 83 Gun-metal 25 mm nominal bore. 84 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 litres capacity 85 Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size : 86 15mm dia 87 25mm dia 88 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C. P. Brass Long body, 15mm nominal bore weight not less than 690 gm 89 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make:- C.P. Brass 15mm nominal bore. 90 P & F Pilllar Cocks (IS :8934 Mark) of superior quality and approved make: C.P. Pillar cock, 15 mm dia nominal bore 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 92 15 mm nominal outer dia pipes 93 25 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 95 15 mm nominal outer dia pipes 96 25 mm nominal outer dia pipes 97 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 98 75mm dia 99 110mm dia 100 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: 101 Bend 87.5 dg. 102 75mm dia 103 110mm dia 104 Plain Tee 105 75mm dia 106 110mm dia 107 Vent cowel 110 mm dia 108 Plain floor trap 110 mm dia. 109 WC Connector with lipring 110 mm 110 Pipe Clip 110 mm 111 Gully trap 110 mm 112 Construction of chamber in all type of soil with 300 mm thick masonry in Cm 1:6 m 100mm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.Inside size 450 x 450 mm depth upto 0.5m cement cover with frame 113 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-Size 230 x110x150 cm.(for 20 users) 114 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 300 Cm. dia outside & 300 Cm. depth . 115 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached. 116 Short point (up to 3 mtr.) 117 Medium point (up to 6 mtr.) 118 Long point(up to 10 mtr.) 119 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached . 120 Medium point (up to 6 mtr.) 121 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached. 122 On board 123 Short point (up to 3 mtr.) 124 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached . 125 25 mm 126 20 mm 127 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached . 128 2x 1.5 sq.mm 129 2 x 2.5 sq. mm. + 1x1.5sqmm 130 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 131 1 x 6.0 sq.mm 132 4 x 10.0 sq.mm 133 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached . 134 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 135 1/2 Module 136 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 137 1-2 Module 138 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached. 139 Single pole MCB (With B/C curve tripping Characteristics) 140 6 A to 32 A rating 141 Triple pole MCB(With B/C curve trippingCharacteristics) 142 50/63 A rating 143 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 144 Four pole Isolator 145 80 A/ 100 A rating 146 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 147 Metal door (Three phase) IK-09 and IP-43with Metal end box 148 6 Way 149 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 150 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 151 4 Way 152 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached . 153 25 Amp. 2 Module Motor Starter with on / off Push button 154 Blanking plate 155 RJ-45, Cat 6 computer jack with shutter 156 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached . 157 5 step fan regulator 2 Module 360 dgree rotating 158 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached . 159 10 A bell push 160 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 161 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached. 162 3 pole MCCB With Thermal Magnetic release 163 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 164 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached . 165 35.0 Sq. mm 166 3.5 core 167 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 168 Supplying and makingend termination with heavy aluminiumlugs ( Pin / ring type )confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached . 169 35.0 Sq.mm 170 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class750 N,Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Teeat required Depth below the ground for laying cable of followingNominal Outer dia.MFR Test reportfrom NABL accrediated is to be submitted.(Excavation of Earth& Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached . 171 110 mm 172 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 173 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 174 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached. 175 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 176 300 mm sweep 177 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 178 Up to 380 mm size 179 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 180 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 181 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 182 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached. 183 Surface Mounting (with extruded alumn. Housing ) 184 Minimum lumen output 1300 lm 185 Minimum lumen output 1950 lm 186 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 187 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached. 188 8 SWG G.I. ( Hot Dipped) Wire 189 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 190 LED Street Light fixture with Minimum lumen output 12500 lm 191 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 192 32 mm Dia. 193 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached. 194 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 195 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 196 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 197 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 198 1 Mtr 199 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 200 24 Port 201 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 202 2.0 TR ISEER not less then 3.8 203 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 204 5 kVA 205 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 206 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 207 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018, Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM /External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 208 6 kg 209 2-Renovation and Improvement at D.W.S. Tonk 210 Clearing and grubbingroad land including uprooting rankvegetation, grass, bushes, shrubs, saplingsand trees girth up to 300 mm, removal of stumps of trees cut earlierand disposal of unserviceable materials and stacking of serviceable material up to a lead of 1000m including removal and disposal of top organic soil not exceeding in 150 mm thickness as per MoRTHspecification clause 201 By mechanical Means. B. In area of thorny jungle 211 Providing and laying granular sub-base material having P.I. notmore than 6 including spreading in layers not exceeding 150 mm compactedthickness andconsolidationby8-10tonnepower rollerto required camber and grade including cost of water and hire charges of machinery including T&P with all lead (Compacted thickness to be measured).asper MoRTHspecification table 400-1, 400-2, For grading-III with CBR value not less than 20.to attain 100%proctor density. 212 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils 213 Supplying and Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand 214 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 215 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 216 Brick work with clay flyash F.P.S. brick(IS 13757- 1993 ) of class designation 75 in superstructureaboveplinth level upto floor five level in : Cement mortar 1 : 4 (1 cement : 4 coarse sand) 217 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 218 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 219 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) 220 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix 221 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 222 Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 223 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 224 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Columns, pillars, posts and struts etc. 225 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 226 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 227 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) 228 Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead: Of area 3 square meter and below. 229 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Partly fixed and partly openable [ fixed area not to exceed 33%] 230 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 231 Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead: For thickness of tiles 10mm to 25mm. 232 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 233 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 234 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 235 Providing and laying water proofing treatment to verti cal and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: Ist course of applying cement slurry @ 4.4 Kg/sum mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. IInd course of 20mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water. proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.. IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg per sqm. of area. IVth course of 400 micron thick PVC sheet .(Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen@ 1.7 Kg/sqm.) 236 Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding. 237 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: 238 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 610 mm x 510 mm 239 Construction of dry lean cement concrete Sub-baseover a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1,aggregate gradation after blending to be as per table 600-1,cement content not to be less than 150 kg/cum,optimum moisture content to be determined during trial length const, concrete strength not tobelessthan10 Mpa at 7 days, mixed in a batchingplant, transportedtosite,laid with a paverwithelectronicsensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per IRC:SP:49-2014 240 Cutting of construction joint/ longitudinal joint 4 to 6 mm. wideusing mechanical concrete cutter including cost of diamond bit cutting wheel and filling of bitumen sealing compound in groove including cost of sealing compound. 241 S&Ffollowingsizes(dia.)ofISImarkedvirginmaterial MMS(IS:9537P-III)PVCconduitalongwith ISI marked (IS:3419-1988) accessories as requiredin recessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached. 242 25 mm 243 32 mm 244 P & F ISI marked (IS :3854) 16 amp. flush type non modular switch CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 245 Providing & Fixing of3/6 pin 16 amp flush type non modular socketmade out from Industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 246 P & F ISI marked (IS:3854) 6 amp. flush type non modular switchwith CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 247 Providing & Fixing ofof 3/5 pin 6 amp. flush typenon modular socketmade out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 248 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached. 249 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electricalWorkswith ISI marked(IS:694)and as perIS 8130:2013of1.1kVgrade.Wireshouldbemade from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flameretardantasperIS10810-53,betteramperage ratingasper IS:3961 part5, inexistingsurfaceor recessed PVC/ MS conduit/casing capping making connectionswithCopperLugsofsuitablesize, Ferrules,testingetc.asrequired.OEMMusthaveits own in house NABL lab setup for all testing facilities for wires.Foradditionaltechnicalparametersof product / work refer Annexure A attached. 250 2 x 1.5 sq.mm 251 2 x 2.5 sq. mm. + 1x1.5sqmm 252 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 253 4x10 sqmm 254 1 x 2.5 sq.mm 255 3 x 6.0 sq. mm. 256 Providing&Fixingof 240/415V ACMCB withpositive isolationof10kAbreakingcapacity(B/C/Dtripping characteristic as per type of load andsite requirement) 4KVimpulsewithstandvoltage,ISImarkedIS 8828(1996) / conforming to IEC 60898-1 2002,IEC 60947-2, low watt losses, trip free mechanisum , energylimitingof class3asperIEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility,IP20contactprotectionandfittedin existingdistributionboard/sheets,minimumelectrical operation 20,000 upto 20 A rating and 10,000 upto 63 A,5000for80A&aboverating includingmaking connections,testingetc.asrequired.OEMshallhave submit NABL / CPRI / ERDA accrediatedlab type test reports& All as perpre approvedby Engineer in charge. For additional technical parameters of product / work refer Annexure A attached. 257 Single pole MCB (With B/C curve trippingCharacteristics) 258 6 A to 32 A rating 259 Providing&Fixingofmodulartype120WStepFan regulatordulyISImarked(IS11037:1984)withCM/L no.printed madeoutofunbreakableandfire retardantverginpolycarbonatewithbrassterminals and captive screws & silver alloy contact tipwith IP-20 rating, including all as perpre approved by Engineer in charge,makingconnections, testing etc. as required. Foradditionaltechnicalparametersofproduct/work refer Annexure A attached. 260 5 step fan regulator 2 Module 360 dgree rotating 261 Providing &Fixingof BEE Starratedcopper wounded double ball bearing capacitor start, aluminium body & Metallic bladeceiling fan Conformingtoallthe performancerequirementslaiddowninIS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with downrod upto 80 cm with secondarysupportsafetycable(steelrope),cotterpin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor makingconnectiontestingetc.asrequired.Allasperpre approvedbyEngineerincharge. Foradditionaltechnical parameters of products/ work, refer Annexure A attached . 262 1200 mm SweepBEE 1 Star rated (service value >=4.0 to < 4.5 ) 263 Providing & Fixing ofIP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver,Systemlumenefficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short &Opencircuitprotection,THD<10%,P.F.≥0.95,CRI>80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K (As per ANSI Bin) , Maximum power consumption shouldnotmorethanthespecifiedratingandFixtureshallbeof BIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/NameEngraved/Embossing/Screenprintingonhousing. OEMmusthaveitsowninhouseNABLlabsetupforalltesting facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEMshallbesubmitted. AllasperpreapprovedbyEngineerin charge. Foradditionaltechnicalparametersofproducts/work , refer Annexure A attached . 264 1170mm (+/-10%) LED batten with min. lumen output 2200 lm 265 Providing & Fixing ofIK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles,of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R numberhaving efficiency more than 85 % and in compliance to BIS certified and Trade markcertificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10%, driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K±355K.Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached . 266 High Power LED Flood Light Minimum lumen output 3700 lm 267 High Power LED Flood Light Minimum lumen output 14800 lm 268 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 269 10.0 Sq. mm 270 2 core 271 16.0 Sq. mm 272 4 core 273 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached. 274 IP -67 Surface/Wall mounted socket 275 32 A 5 pin(3P+N+E) 276 Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached . 277 Double pole isolator 278 30 A / 40 A rating 279 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached. 280 3 pole MCCB With Thermal Magnetic release 281 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 282 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 283 Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/IS-8623 & IEC-60529/IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31,front openable bus bar made out of Coppersuitable for 200 amp. Capacity, bus barfixed on porcelain/DMC insulators at approved spacingincluding making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached . 284 600 mm long , 4 strip 285 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached. 286 3.0 mm thick 287 SITC of IP-42 and general construction confirming to IS:8623: 1993,wall/ freestandingfloormounteddustandvermin proofcompartmentalisedcubicalpanel asspecifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 288 (a)ThicknessofCRCAsheetshall be2.0mm, cablealley compartmentshavingconcealedhingedtypedoorswith keytypelockwith/without detachableextensiontype structure.Removable3mm. thicksheetsteelglandplates with appropriate size of knockouts for cables shall beprovided 289 (b)completepanelshallundergoaprocessofdegreasing, Waterrinsing,Activation,derusting, picklinginacidbath, phosphatising & shall be subjected to nine tank process and thenPowdercoatedwithapprovedshadeofminimum70 microns on both side of panel. ThepanelhavingPE foam/ Neoprenerubbergasketofnotlessthan3mmthickness,requiredhardware,concealedhingeddoorwithkey type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 290 [c)Interconnection between bus bar and switchgears/cableshallberigidlysupportedandmadeoutbyflexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp) . controlwiring will becarried outwith 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wireonly. Alljoints/interconnectionsofcopperbusbar shall be dully tinned . Clearance between main bus bar and risers/metalpartsshallbeatleast10mmadditionalto widthofbusbarBusbarisinsulatedbyHeatShrinkable sleeves . Earth and Neutral bus bar shall be half of the size ofphasebusbar.(CostofBusbar /Flexiblewirefor Interconnection between Main busbar and Switchgearis tobe Paid Extra ) 291 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminalblockonly.Directconnectionshallnotbe permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identificationstrips and shall have adequatecontinuouscurrentrating.Fortap-offs,adjacent terminalswithshortingstripsshallbeused. 10%Spare terminalblocksshallbeprovided.Wireidentificationon markingstripshallcorrespondtothedesignationofthe wiring diagrams.All wire terminals on theequipmentshall also be marked with designationcorrespondingto those ofthe wiring diagram. 292 (e)All wiring shall be enclosed in plastic channels and neatly bunchedandclosed in metering chamber,Wiring between terminalsofvariousdevicesshallbe‘pointtopoint’(no wire splitting or tee connections)with wires neatly trucked alongthe back ofthe panels, adequately supported toprevent sagging. 293 (f)Floor mountedpanel shall be mountedon Base frame ofISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 294 (g)Tests:Theinsulationresistance(with1000VMegger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases,between phaseand neutraland between phase and earth. both before and after high voltage power frequencytest.Theinsulationresistanceshallnotbeless thanthreemegaohm.CTSecondarycurrentinjectiontestshall also be carried out. 295 (h) only outer surface area on all sides shall be measured & paneltobefabricatedonlyfromCPRIapprovedfabricator only(CPRITestcertificatestobesubmitted)Allasperpre approvedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure Aattached . 296 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper(IEC60028)busbarbymeansofSMC/DMCtype insulator with standardshortcircuitwithstandcapacity , high tensile nuts and bolts spring washers in existing panel includingbending,cuttinginrequiredshapeandsizeand colourcodingwithheatshrinkablePVCsleeves.Allasper preapprovedbyEngineerincharge.Foradditional technicalparametersof products/work ,referAnnexureA attached . 297 Electrolytic grade Aluminium bus bar 6010 grade 298 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter/MultiFunctionMeter/Poweranalyzerofclass1 accuracy as perIS : 1248 of size 96mmx 96mm including making connection by PVC insulated copper conductor with PVCsleeves/channel etc.asrequired.Allasperpre approvedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure Aattached . 299 Three phase Ammeterwith Inbuilt Selector Switch 300 Three phase Voltmeter with Inbuilt Selector Switch 301 Providing & Fixing of BIS approvedCurrent Transformeras perPWDspecificationforelectricalWorks,ISImarkedas per IS 2705-1992/conformingto IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminalblockwhichshallbeeasieraccessiblefortesting andterminalconnection,withallnecessarysupportin existingpanelincludingconnectionetc.asrequired Current transformer Ring Type Tape Wound/Resin Cast WoundasperIS16227with,AccuracyCl,CTratioand burdenasspecified.ISF<=5,Cucrosssectionofsecondary wire1.5sqmm(minimum),includingallnecessarysupport inexisting panelincludingconnectionetc. as required. All asperpreapprovedbyEngineerincharge.Allasperpre approvedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure Aattached . 302 Ring type tape wound CT 303 C T Class 1, Ratio upto 150/5, Burden 5 VA 304 Providing&Fixingofselectorswitchof 10Afor voltmeter using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamidewith hightracking index.For reliableandstable electricalandmechanicalendurancedoublebuttcontacts withsilverbi-metaloncoppershouldprovided.contact assemblyisofoperatingtemprange-25degreeCto55 degree C, frequencyupto10 KHz. switch life understd. op. conditionsshall bemechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour includingmakingconnectionetc. asrequired.Allasper preapprovedbyEngineerincharge.Foradditional technicalparametersof products/work ,refer AnnexureA attached. 305 Voltage Between Phases with OFF ( 4 Position ) 306 Providing & Fixing of CT linked selector switch of 10 Afor Amperemeter(4position) usinghighgradeengineering materialto international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance doublebuttcontacts with silver bi-metalon coppershould provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life understd.op.conditionsshallbemechanicallyminimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc.as required .All as per pre approvedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure A attached . 307 Providing&Fixingof 110/220V,unibodyLEDIndicating lampIEC60947 withintegralcircuit,IP65abovepanel& IP20terminalblock,Approx.bodydiaforpanelnotless then20mm,lengthmin.50mm,frontLEDcoverdiamin. 29mm,contactmaterialphospher bronzeforLed,PCB contactsshallbeof brass(tinplated),impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohmat500VDC includingconnectionetc. asrequired. All asperpreapprovedbyEngineerincharge.Foradditional technicalparametersof products/work ,referAnnexure A attached . 308 Red/yellow/Green colour 309 Providing&FixingofElectrical insulatingrubbermattsas per PWD specification for electrical Works, ISI marked confirmingtoIS:15652/ 2006 withoneside antiskid abberation marks and pasting the mat with synthetic rubberadhesiveasrequired.Allasperpreapprovedby Engineerincharge.Foradditionaltechnicalparametersof products/work ,referAnnexureAattached . 310 3.3KV, classA2mmthickwithproofvoltage10KVAC(rms) and Break Down Voltage 30 KV AC (rms) 311 P & F in position frame made out of M.S. angle (riveted orwelded)finishedwithtwocoatsofredoxideand two coats enamel paint including cutting, welding, holesetc.offollowingsizesasrequired.Foradditional technical parameters of product / work refer Annexure A attached. 312 50mm x 50mm x 6mm 313 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached. 314 300 mm sweep(900/1400 RPM) 315 Add extrain item no. 13.2.1 for Laying Charges for cable through Manual Boggi by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required.