}

Tender For Water Supply Scheme For Augmentation Of Uwss Jalore District Jalore Including 05 Years O And M After 01 Year Defect Liability Period Under Amrut 2 - 1 Amrut 2.0 Uwss Jalore 2 (1.1) Providing,Lowering,Layingintrenches,Aligning,Fixinginposit, pali-Rajasthan

Public Health Engineering Department has published Tender For Water Supply Scheme For Augmentation Of Uwss Jalore District Jalore Including 05 Years O And M After 01 Year Defect Liability Period Under Amrut 2 - 1 Amrut 2.0 Uwss Jalore 2 (1.1) Providing,Lowering,Layingintrenches,Aligning,Fixinginposit. Submission Date for this Tender is 16-03-2025. Water Supply Project Tenders in pali Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

47693450
Corrigendum : Tender For Water Supply Scheme For Augmentation Of Uwss Jalore District Jalore Including 05 Years O And M After 01 Year Defect Liability Period Under Amrut 2 - 1 Amrut 2.0 Uwss Jalore 2 (1.1) Providing,Lowering,Layingintrenches,Aligning,Fixinginposit
Open Tender
NCB
Rajasthan
Pali
16-03-2025

Tender Details

Tender For Water Supply Scheme For Augmentation Of Uwss Jalore District Jalore Including 05 Years O And M After 01 Year Defect Liability Period Under Amrut 2 - 1 AMRUT 2.0 UWSS JALORE 2 (1.1) Providing,lowering,layingintrenches,aligning,fixinginposition and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas perIS:8329-2000(amended upto date), with internal cement mortarliningsuitableforpotable waterwithrubberring(EPDM) jointsasperIS:5382-1985includingalltaxes(Centralandlocal), transportationandfreightcharges,inspection charges,loading/ unloadingcharges, includingcostoflabourandmaterial,specials (Tee,bendetc.)satisfactoryhydraulictesting,disinfection, commissioningetc.completeaspertechnicalspecificationsand direction of Engineer-in-charge. (excluding earth work)Note :Providing andfixing ofall requisitespecials asper drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 3 (1.1.2) 100 mm 4 (1.1.3) 150 mm 5 (1.1.4) 200 mm 6 (1.1.5) 250 mm 7 (1.1.6) 300 mm 8 (1.3) Providing,lowering,laying,aligning,fixinginposition andjointing atalllevel/depthsDIstandardspecialswithrubberring (EPDM)/ nut bolt and insertion sheet andjointingasperIS:9523- 2000 or as amended up to date,suchastees,bends, tapers,caps etc. within trenchesin DI pipe line completeincluding all material, labour,taxes,testing andcommissioning alongwithpipelineas pertechnical specificationsand direction ofEngineer-in-charge (excluding earth work). 9 (1.3.2) All End Flanged 10 (1.3.2.1) Up to 300 mm Diameter 11 (1.4) Providing, lowering, laying and jointing in trenches,standard lengths HDPE ISImarkedPipesasperIS-4984:1995(amended up todate) withnecessaryjointingmateriallikemechanical connectors,i.e.thread/insertjoint/quickreleasecouplerjoint/ compression fitting joint or flanged jointand specialsjointing pipe by electrofusionweldingmethod,includingalltaxes, transportationandfreightcharges,inspection charges,loading/ unloadingcharges,stackingofpipes,includingcostoflabourand material,specials(Tee,bendetc.),satisfactoryhydraulictesting, disinfection,commissioningetc.completeaspertechnical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note :Providing andfixing ofall requisitespecials asper drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 12 (1.4.2) HDPE PE-100PN-6 13 (1.4.2.3) 90 mm dia 14 (1.4.2.4) 110 mm dia 15 (1.5) Providing, lowering, laying and jointing in trenches,standard lengths HDPE ISImarkedPipesasperIS-4984:1995(amended up todate) withnecessaryjointingmateriallikemechanical connectors,i.e.thread/insertjoint/quickreleasecouplerjoint/ compression fitting joint or flanged jointand specialsjointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportationandfreightcharges,inspection charges,loading/ unloadingcharges,stackingofpipes,includingcostoflabourand material,specials(Tee,bendetc.),satisfactoryhydraulictesting, disinfection,commissioningetc.completeaspertechnical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work).Note :Providing andfixing ofall requisitespecials asper drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 16 (1.5.2) HDPE PE-100PN-6 17 (1.5.2.1) 125 mm dia 18 (1.5.2.2) 140 mm dia 19 (1.5.2.3) 160 mm dia 20 (1.5.2.4) 180 mm dia 21 (1.5.2.6) 225 mm dia 22 (1.6) Manufacturing,supplying,lowering,layingandjointinginposition tocorrectlinespirallyweldedSAW/FabricatedMSPipehaving bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, includingalltaxes(Centralandlocal),transportationandfreight charges,inspectioncharges,loading/unloadingcharges, including costoflabourandmaterial,specials(Tee,bendetc.),fieldjoints, satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer- in-charge; (excluding earthwork, internal lining and outer coating).Note :Providing andfixing ofall requisitespecials asper drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 23 (1.6.1.3) 4 mm 24 (1.6.8) Outer dia of pipe 610 mm and thickness 25 (1.6.8.3) 7.1 mm 26 (1.15) Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, insidelining,outsidecoating,testing and commissioningalong with pipe line as per technical specificationsand directionof Engineer-in-charge. 27 (1.15.1) MS pipespecialsup to600mmdia (withminimum5mmthickness sheet) 28 (1.26) Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit& jhiri with watering& ramming/compactinginlayersanddisposalofsurplusexcavated soil as directed with in a lead of 100 meter ; providing & fixing of all fittingdulyapprovedinaccordancewith specificationforpotable waterincludingelectrofusionsaddlepiece,gunmetalferrule4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as perISO4427/20mmnominal diaPPR-C(Threelayered)pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GIpipeswithfittingsinthepremisesforfixingatap/meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note:Roadcutandrestorationisnotpartofthisitemandpaid separately. 29 (1.27.1) Forconnectionwith20mmdiaMDPE/PPR-C pipelength upto 05mtr. 30 (1.3) Road cutting for house hold service connection in minimum trench widthwhereverroadcrossingisrequired.Roadcuttingofcement concrete,WBM, Black top etc. of all thickness shall be doneby using aconcretecuttermachinekeepingminimumtrenchwidthand restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. 31 (1.31) Add extra over itemno 1.21, 1.22 & 1.23 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 32 (2.11) Supply of ERWM.S. black casing pipe ISI marked (IS: 4270/2001) or amendedup to dateoffollowing sizes 33 (2.11.1) 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) 34 (2.11.2) 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) 35 (2.11.3) 250 mm dia NB (Thickness of pipe 7.1 mm & mass of tube 46.57 Kg/m) 36 (4.1) Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soilas requiredin layers not exceeding 20cm indepth including consolidatingeachdepositedlayerbyramming,wateringetc.anddisposalof surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 37 (4.3) Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soilas requiredin layers not exceeding 20cm indepth including consolidatingeachdepositedlayerbyramming,wateringetc.andstacking serviceable materialformeasurements anddisposalof unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .: 38 (4.3.1) Ordinary rock 39 (4.5) Dismantlingofcementconcretepavementforpipeline andchambersby mechanicalmeansusingpneumatictools,cuttingtheperipheraledgebyCC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters.Measurementfordismantledtrenchtobemade asperstandard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 40 (4.6) Dismantlingofflexiblepavementforpipeline andchambersbymechanical meansusingpneumatictools,breakingtopiecesnotexceeding0.02cumin volumeandstockpilingatdesignatedlocationsanddisposalofdismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to bemade asperstandardtrenchwidthspecifiedintenderdocumentandno extra payment shall be made be made for trench width more than specified, re- handling of material/earth to complete the tasks per technical specification and scope of work. 41 (4.6.1) Bituminous courses 42 (4.6.2) Granular courses 43 (4.7) Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1Cement:3coarsesand:6gradedstoneaggregate40mmnominalsize)in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified intenderdocument andno extrapayment shallbe made be madefortrench widthmorethanspecified, completeworkaspertechnicalspecificationand scope of work. 44 (4.8) Providingand laying in position cementconcrete in specified gradeover prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line andchamberwork.MeasurementforCCworktobemade asperstandard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 45 (4.8.2) Plain cement concrete pavementof M-30 Grade 46 (4.11) Supply laying and pushing of MS casing pipe of specified thickness approved by concerneddepartmentauthoritybytrenchlessmethodadoptinganysuitable technology below ground at required depth under running traffic condition as perHighway/Railwaystandardincludingcarryingoutsurveyworkatthejob site for determining underground cable trenches like telephone, cable, water & sanitarylinesandresistivitytestforfindingthesoilstratausingnecessary equipments for completion of works, mobilizing of machineries and specialized crewat the jobsite complete inallrespect, includingexcavationofdrivenpit andexitpit(upto3meterdepth)withproperprotectionatthesesiteswith shoringsheetsandISMB.ProvidingMScuttingedgesforfrontshieldand constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporaryworksasperdesign,drawingandmethodasperapprovedby authority specification and the direction of the Engineer.Applycorrosion,resistant,protectiononinsideandoutsideofcasingpipe as per technical specification. 47 (4.11.2) 400 mm Dia 8 mm thick casing pipe . 48 (5.7) Providingandfixing atsitewithnecessarypacking, HorizontalCentrifugal Split Casting pumps with 4 poleinduction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casingandcasingring,SS316impeller,SS410Shaftandshaftsleeve, couplingguard,commonbaseplate,foundationbolts,Cementconcrete foundation etc. complete with all respect as per the specification and scope ofworkanddirectionofEngineerinChargeoffollowingrangeofduty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. 49 (5.7.26) Discharge 20 to 30 LPS and head 71 to 80 M 50 (5.7.25) Discharge 51 to 60 LPS and head 51 to 60 M 51 (5.7.6) Discharge 51 to 60 LPS and head 61 to 70 M 52 (6.8) Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuumtight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirmingtoBS-EN-1171/AWWAC-509andoffollowing specifications:Body & bonnet ofDuctile castiron ofgrade GGG40/GGG50as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202F4,Stem/spindleofSSAISI316/410Electrostaticepoxypowder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thicknessof250micronsinsideandoutside,DrilledasperIS1538.Nut-Bolt confirmingtoIS:1363andIS:1367 (Galvanisedsteel)Insertionrubberofblack EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves includingall jointing& jointingmaterial, labour,testingandcommissioningalong withpipelineasperTechnicalSpecificationsandasperdirectionofEngineer-in- charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 53 (6.8.1) Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 54 (6.8.1.2) 100 mm dia 55 (6.8.1.3) 125 mm dia 56 (6.8.1.4) 150 mm dia 57 (6.8.1.5) 200 mm dia 58 (6.8.1.6) 250 mm dia 59 (6.8.1.7) 300 mm dia 60 (6.8.1.12) 600 mm dia. 61 (6.9) Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approvedmakeoffollowingclass&diacompleteconfirmingtoBSEN593/BS 5155/IS13095/1991amended up todateandoffollowingspecifications:Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12asperIS 1865or equivalentgrade asper IS :3896-part2-1985 and subsequentrevisions,FacetofacedimensionsasperDIN3202F4/IS13095 DrilledasperIS:1538.ElectrostaticEpoxyPowder(EP-P)/FusionBondedEpoxy (Non-Toxic&suitablefordrinkingwater)coatedwithminimumthicknessof250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene(foodgradequality)anddiscsealretainingringofSS/CS.ShaftofSS- AISI- 410/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR O ring seal,Nut-BoltconfirmingtoIS:1363andIS:1367(Galvanisedsteel)Insertion rubber of black EPDM 6mm thick. Suitable support structureas perdirections of EIC including jointing & jointing material, labour, testing and commissioning along withpipelineasperTechnicalSpecification&asperdirectionofEngineer-in- charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 62 (6.9.1) Class PN 1.6, Manually Operated with Gear 63 (6.9.1.1) 100 mm dia 64 (6.9.1.2) 150 mm dia 65 (6.9.1.3) 200 mm dia 66 (6.9.1.4) 250 mm dia 67 (6.9.1.5) 300 mm dia 68 (6.9.1.6) 350 mm dia 69 (6.12) Providing,lowering,aligning,fixinginpositioninpipeline,DI doubleflanged resilient seatedDual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12asperIS1865orequivalentgradeasperIS:3896-part2-1985and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR O ring seal, Nut-Bolt confirmingtoIS:1363andIS:1367(galvanisedsteel), Insertionrubberofblack EPDM6mmthick.Suitable supportstructureasperdirectionsofEIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 70 (6.12.1.4) 150 mm dia 71 (6.12.1.5) 200 mm dia 72 (6.13) Providing,lowering,aligning,fixinginpositionandJointinginpipeline,DIBody FlangedEndTamperproof KineticAirValveofapprovedmakesoffollowing pressureratinganddiaandasperfollowingspecifications:Governingstandard- AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl andJoint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 orGR SG-400/12as perIS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fasteners - CS/ Galvanised steel, Outlet of big orifice will haveascreentopreventTamperoffloat, withDImetalseatedD/FNonrising stemSluiceValvesasper(IS:14846amended uptodate)PN1.6ratingsValves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 73 (6.13.1) Class PN 1.6 74 (6.13.1.2) 50 mm dia 75 (6.17) Providing,lowering,laying,aligning,fixinginpositionandjointingCIdismantling joint(SuitableforSluicevalvesetc.)asperISspecifications complete of the following sizes including alljointingmaterial, cost of all labour, testing and commissioning Technical Specifications and as per directionof Engineer.Class PN 1.0 76 (6.17.2) 100 mm dia. 77 (6.17.3) 125 mm dia. 78 (6.17.4) 150 mm dia. 79 (6.17.5) 200 mm dia. 80 (6.17.6) 250 mm dia. 81 (6.17.7) 300 mm dia. 82 (6.17.12) 600 mm dia. 83 (6.19) Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specificationsandlayoutdrawingsincludingjointingmateriallikenuts,bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. 84 (6.19.2) 100 mmdia. 85 (6.19.3) 125 mm dia. 86 (6.19.4) 150 mm dia. 87 (6.19.5) 200 mm dia. 88 (6.19.6) 250 mm dia. 89 (6.19.7) 300 mm dia. 90 (9.1) ConstructionofRCCSluicevalvechamberfordifferenttypeofvalves includingearthworkexcavation,100mmPCCM15 aslevellingcourse, RCC M25 grade for base slab, side wall & cover slab , including cost of steelreinforcement,formwork,Pre-castslabs,plasticencapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications andstandard drawings and as per direction of Engineer-in-Charge. 91 (9.1.1.) For Class-AA loading 92 (9.1.1.1) Sluice valve chamber of size 1.13 m x0.85 m x1.325 m-for pipe size-up to 100 mm 93 (9.1.1.2) Sluice valve chamber of size 1.17m x 0.95m x1.47mfor pipe size-from 125-to-150mm 94 (9.1.1.3) Sluice valve chamber of size 1.26m x1.185m x1.88mfor pipe size-from 200-to-300mm 95 (9.1.1.5) Sluice valve chamber of size 1.61m x1.75m x2.85mfor pipe size-from 500-to-700mm 96 (9.5) ConstructionofRCCpillarforfollowingsizeofairvalvesincluding earthworkexcavation, RCCM25gradeforbaseslab,verticalpillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work,propercuringofconcreteworkcompleteinallrespectasper standard specifications and drawings and as per direction of Engineer-inCharge. 97 (9.5.1) Air valve pillarfor airvalves size of 80mmdia 98 (11.1) SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of followingdiaandspecificationscomplete:Media:Water(Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum,Lining Material : HardRubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completelysealed(leakproof)constructionasperrequirementofIEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertorEnclosure:DieCastAluminium,PowerSupply:80-240VAC- 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) andIP67fortransmitter/convertor,includingSurgeArrester,ifrequired, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 99 (11.1.3) EFM100 mm 100 (11.1.4) EFM 125 mm 101 (11.1.5) EFM 150 mm 102 (11.1.6) EFM 200 mm 103 (11.1.7) EFM 250 mm 104 (11.5) SITCof UltrasonicLevelTransmittersuitable formeasuring waterlevel in reservoir,poweredbysolarpanelwithminimum48powerbackupor internal installed battery ( 5 years battery life with replacement warranty), with out put as GSM/GPRS + data logger , Sensor Material: PP, accuracy +/_0.2 %,as per detailed Technical specification, scope of work and direction ofEngineer in charge. 105 (11.5.1) Measuring range 0.0 to 6.0 mtr 106 (Ruidp 7.3.2)GSB Providing, laying, spreading and compacting of granular sub-base by providing close graded material (Table 400-1), spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRT&H specification clause - 401 including all material, labour, machinery, lighting, guarding and maintenance of diversion. 107 (7.3.2) For Grading II Material 108 (Ruidp 7.5.3) WBM Grading 1 Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; handpacking, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up the interstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete. 109 Crusher broken - Grade-III (53-22.4mm) 110 (Ruidp 8.1) Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS : 8887 and approved quality @ 0.6 kg/sqm with the help of spray set fitted on bitumen Container (boiler) after cleaning the surface including removing of binding material and other foreign matter with wire brushes and small picks, sweeping with brooms or soft brushes and finally dusting with old gunny bags and compressed air to receive bituminous treatment complete as per clause 502 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 111 (Ruidp 8.12.1) Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as per Table 500-23, premixed with bituminous binder @ 14.60 kg/ 10sqm (including Cost of anti stripping compound Minimum 1% in Lime/Cement as per design wherever required), including loading of material with F.E. loader, hot mixing of stone aggregate and bitumen in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control to the required level and grade, compacting smooth wheeled roller 8-10 tonne capacity and finishing to required level to achieve the desired density as per clause 511 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion but excluding cost of tack coat/ seal coat. 112 With Bitumen VG-grade 30 113 (Ruidp 8.14.1)SEAL COAT;-Providing and applying liquid seal coat type A comprising of a layer of bituminous binder @ 9.8 kg/ 10 Sqm (including Cost of anti stripping compound Minimum 1% in Lime/Cement as per design wherever required) followed by a cover of stone chipping @ 0.09 cum/10 sqm of specified grading and rolling with power roller 8-10 tonne complete as per clause 513 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 114 With Bitumen VG-grade 30 115 (PWD 2022-) CARRIAGE OF MATERIALS-Earth, Sand, Lime, Morrum manure or sludge 116 Lead up to 2 Km 117 (19.97) Providing and fixing in position lightening arrester set complete with 600mmx600mmx6mmthickG.I. earthingplate embeddedbelow groundinearthlingpitat3.5metrdepth,G.I.stripofsize 25mmx5mm thick from earthing plate to top of Over head tank, G.I. FinialmadeofGIbar25mmdiaand2mlongfixedontopofOH tankandconnectedtoGIstrip.Theearthlingsetshallcomplyof IS:3043 complete in all respect as per specification and the direction of the Engineer. 118 (42.36) Pipe Ear thing as per IS: 3043 with perforated 3.0 Mtr. Long, 40 mm dia.‘B’classG.I.Pipeincludingallaccessorieslikenut,bolts, reducer,nipple,wiremeshedfunnel,andC.C.finishedchamber coveredwithhingedtypewithlockingarrangementC.I.Cover,C.I. Frame of size 300mm x 300 mm and embodying the pipe complete withalternatelayerssaltandcoke/charcoal,testingofearth resistance as required. 119 (42.37) PlateEarthlingasperIS:3043withcopperEarthplateofsize 600mmx600mmx3.0mmbyembodying3to4mtr.Belowthe ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C.finishedchambercoveredwithhingedtypewithlocking arrangementC.I.Cover,C.IFrameofsize300mmx300mm completewithalternatelayersofsaltandcoke/charcoal,testingof earth resistance as required. 120 (42.38) S & Laying following size ‘B’ Class G.I.Pipe confirming to IS: 1239 P-1 (1990) with accessories for laying earth conductor/ strip/ cable in ground/ surface/ recess as required. 121 (42.38.1 ) 50 mm dia. 122 (42.49) SupplyinganddrawingPVCinsulated&sheathedsolid/stranded copperconductormulticorecontrolcableISImarked(IS:1554)of 1.1kVgradeofapprovedmakeasperchapterE11,inexisting surfaceorrecessedconduit/casingcappingincludingmaking connections etc. as required. 123 (42.49.2.2 ) 4 core, 1.5 sq. mm. armoured 124 (42.49.2.4) 8 core, 1.5 sq. mm. armoured 125 (42.49.4.4) 8 core, 2.5 sq. mm. armoured 126 (42.49.2.6) 12 CORE, 1.5 sq. mm. armoured 127 (43.7) Providing,Installation,TestingandCommissioningofPressure Transmitter : Range:0-10Bar / Power Supply:24 V DC / Output: 4-20mAwithHART/Diaphragm:SS316L/ProcessConnection: 1/2 NPT (M) / Accuracy: 0.15% Protection: IP67 128 (43.9) Providing,installation,testingandcommissioningofDiaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass,Overrangeprotection:125%ofmaximumpressure,Material ofsensorandotherwettedparts:SStype316,Housingmaterial: Die cast aluminum 129 (43.1) Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material ofsensorandotherwettedparts:SStype316,Housing:Diecast aluminum,Switchtype:Microswitch,Repeatability:±1%ofspan, Switch Contacts: 2 NO + 2 NC 130 (43.12) Providing,Installation,TestingandCommissioningofUltrasonic LevelTransmitter:Principle:TimeofFlight/SensorMOCPP/ PowerSupply:24VDC/Output:4-20mA/Display:Integral displayforprogrammingandDisplayReading/IP66/Accuracy ±1% 131 (43.12.1) 0 - 5 Mtr. 132 (43.13) Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes,Probeinsulation:Teflon,Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminum 133 (43.13.1) Rigid for lengths ofup to 3 Mtr. 134 (43.23) Providing,installation,testingandcommissioningofONLINEUPS SYSTEM,SinglePhase230V,50Hzwith2hourbackupSMF battery bank as per specification 135 (43.23.1) 1 KVA 136 (43.28) Supply, Installation, testing and commissioning of Battery powered Electromagnetic flow meters with GSM/GPRS based with an accuracy of ± 1% of measured value, ingress protection Electronics IP 66 and flow tube IP 68, MOC: lining Neoprene rubber/Hard rubber/PTFE, Flange - SS316/SS304/MS/CS, Electrode - SS 316/Hastalloy, Coil Housing - SS, battery life of min. 5 years, LCD display 5 digit for instantaneous flow and 9 digit for Totalized flow as per technical specifications of following sizes:(DMA) & EX. ESR 137 (43.28.11) EFM 150 mm 138 (43.28.12) EFM 200 mm 139 (43.28.13) EFM 250 mm 140 (44.6) SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. 141 (44.6.3) 37KW 142 (44.6.4) 45KW 143 (44.6.6) 75KW 144 (47.1) Design,Manufacture,Supply,Installation, TestingandCommissioningofIndoortypePLC Panelofsizeapprox.800mmX500mmX 2000mm(LBH),Fabricatedoutofmin.2mm thickCRCAsheetcompletewithlatest configuration,necessaryprogrammingsoftware forPLC&SCADAandcomprisingofall accessories not limited to the following: DI 30No. DO 26No. AI 6No. AO 2No. MCB 16A DP 2No. MCB 6A DP6No. SMPS 100-240VAC/ 4.5A / 24 VDC 1No. Selector Switch (Auto/Manual) & Local / Remote2No.Control Relays1Lot Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with1No.Electronic Hooter1No. Control Transformer 200VA1No. Emergency STOP Push Button1No. Panel Cooling Fan & Filter2No. Panel Light with Door Switch, 7W1No. Control Indication Lamp for 24VDC, 220VAC3No.Push Button3No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc1Lot PanelHardware,lugs,terminations,ferruls, name plate Ect.1Lot UTILITY SOCKET 16A, 3 PIN2No. HMI Display 10 Inch, Colour1No. Isolators Dual Output, 24VDC1Lot 145 (55.1) Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kAbreakingcapacity(B/C/Dtrippingcharacteristicaspertypeof loadandsiterequirement)4KVimpulsewithstandvoltage,ISI markedIS8828(1996)/conformingtoIEC60898-12002,IEC 60947-2,lowwattlosses,tripfreemechanisum,energylimitingofclass3asperIEC,minimumphaseterminationcapacityof 35sq.mm. , conductor line load reversibility , IP 20 contact protection andfittedinexistingdistributionboard/sheets,minimumelectrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A&aboveratingincludingmakingconnections,testingetc.as required. OEM shall have submitNABL / CPRI / ERDA accrediated labtypetestreports&AllasperpreapprovedbyEngineerin-charge.Foradditionaltechnicalparametersofproduct/workrefer Annexure A attached with this BSR 146 (55.1.3.2) Triple pole MCB(With B/C curve trippingCharacteristics), 6 A to 32 A rating 147 (55.1.4.2 ) Four pole MCB (With B/C curve tripping Characteristics), 6 A to 32 A rating 148 (55.1.2.2 ) Double pole MCB(With B/C curve tripping Characteristics) , 6 A to 32 A rating 149 (57.1) SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/freestandingfloormounteddustandverminproof compartmentalisedcubicalpanelasspecificationsandOther parameters requiredas per point (a) ,(b), (c),(d, (e), (f), (g), (h) as below:-(a)ThicknessofCRCAsheetshallbe2.0mm,cablealley compartmentshavingconcealedhingedtypedoorswithkeytype lock with / withoutdetachable extension type structure. Removable 3mm.thicksheetsteelglandplateswithappropriatesizeof knockouts for cables shall be provided(b)completepanelshallundergoaprocessofdegreasing,Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panelhavingPEfoam/Neoprenerubbergasketofnotlessthan 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) nterconnectionbetweenbusbarandswitchgears/cableshall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried outwith1.5Sq.mm,Earthwirewith2.5Sq.mmandCTwith2.5 sq.mmflexiblecopperwireonly.Alljoints/interconnectionsof copper bus bar shall be dully tinned . Clearance between main bus barandrisers/metalpartsshallbeatleast10mmadditionalto widthofbusbarBusbarisinsulatedbyHeatShrinkablesleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (CostofBusbar/FlexiblewireforInterconnectionbetweenMain connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)FloormountedpanelshallbemountedonBaseframeofISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute)shallbemeasuredbetweenphases,betweenphaseand neutralandbetweenphaseandearth.bothbeforeandafterhigh voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to befabricatedonlyfromCPRIapprovedfabricatoronly(CPRITest certificates to be submitted)All as per preapproved byEngineerin-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .busbar and Switchgearis to be Paid Extra ) (d)WiringbetweencomponentswithinswitchgearandIncoming/ outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted.Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads,studswithtwonutsandidentificationstripsandshallhave adequate continuous current rating. For tap-offs, adjacent terminals withshortingstripsshallbeused.10%Spareterminalblocksshall be provided. Wire identification on marking strip shall correspond to thedesignationofthewiringdiagrams.Allwireterminalsonthe equipmentshallalsobemarkedwithdesignationcorrespondingto those of the wiring diagram. (e)Allwiringshallbeenclosedinplasticchannelsandneatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee 150 (57.2) SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/ Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwithstandardshortcircuitwithstandcapacity,hightensilenuts and bolts spring washers in existing panel including bending , cutting inrequiredshapeandsizeandcolourcodingwithheatshrinkable PVCsleeves.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 151 (57.2.1) Electrolytic grade Aluminium bus bar 6010 grade 152 (57.3) Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/Frequencymeter/KWHmeter/MultiFunctionMeter/ Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96mmincludingmakingconnectionbyPVCinsulatedcopper conductorwithPVCsleeves/channeletc.asrequired.Allasper preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexureAattachedwith this BSR . 153 (57.3.3) Three phase Ammeterwith Inbuilt Selector Switch 154 (57.3.4) Three phase Voltmeter with Inbuilt Selector Switch 155 (57.3.10) Three phase with universal Auxiliary supply + AMP + HZ + PF + KW +KVA+KVAR+KVARH+KWH+DUALENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 156 (57.4) Providing&FixingofBISapprovedCurrentTransformerasper PWD specification for electrical Works ,ISI marked as perIS 2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCT shallbebroughtoutsuitabletoaterminalblockwhichshallbe easieraccessiblefortestingandterminalconnection,withall necessarysupportinexistingpanelincludingconnectionetc.as requiredCurrenttransformerRingTypeTapeWound/ResinCast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm (minimum),includingallnecessarysupportinexistingpanel includingconnectionetc.asrequired.Allasperpreapprovedby Engineerin-charge.AllasperpreapprovedbyEngineerin-charge. Foradditionaltechnicalparametersofproducts/work,refer Annexure A attached with this BSR . 157 (57.4.2) Resin cast wound type CT 158 (57.4.2.3) C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA 159 (57.7) Providing & Fixing ofCam operated rotary (Auto/manual) switches onexistingpanelwith2wayandoffpositionusinghighgrade engineeringmaterialtointernationalstandardswithcamassemblyinsulationofglassfilledpolyamidewithhightrackingindex.For reliable and stable electrical and mechanical endurance double butt contactswithsilverbi-metaloncoppershouldprovidedcontact assemblyis of operating temp range-25 degree C to55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanicallyminimum50000operations@300cycles/hourand electrically10,000operationsat100%rateddutyfor100cycles/ hourincludingmakingconnectionetc.asrequired.Allasperpre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 160 (57.7.1 ) 10 AMP 161 (57.8) Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947withintegralcircuit,IP65abovepanel&IP20terminal block,Approx.bodydiaforpanelnot lessthen20mm,lengthmin. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexureAattachedwith this BSR . 162 (57.8.1) Red/yellow/Green colour 163 (57.8.1) Blue / white Colour 164 (57.9) Providing&FixingofflushheadpushbuttonactuatorsIEC60947withintegralcircuit,IP65abovepanel&IP20terminalblock, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze forLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,includingconnectionetc.asrequired.AllasperpreapprovedbyEngineerin-charge.Foradditional technicalparametersofproducts/work,referAnnexureA attached with this BSR 165 (57.9.1 ) Non luminous type 166 (57.1) Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 withonesideantiskidabberationmarksandpastingthe matwithsyntheticrubberadhesiveasrequired.Allasperpre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 167 (57.10.2) 11 KV,Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage45 KV AC (rms) 168 (57.11) Providing&FixingofselfhealingIP20MPPtypeshuntcapacitor (banks) conforming to IS:13340-41 /IEC :831-1&2 OR IEC : 60831-1&2inexistingpanelorparallelwithloadterminals,thecapacitor shallbefittedwithdischargeresistors,pressuresensitive disconnector(PSD)andshallhavedissipationfactorlessthan 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min overcurrentcapacity1.8timesratedcurrent&peakinrushcurrent min.300timesofratedcurrent,llifeexpectancygreaterthan 100000hrs(tempclass-25D)in440V/480VCapacitorandfor 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D)including making connections, testing etc. as required.All as per preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexureAattachedwith this BSR . 169 (57.11.1) HeavydutyThreephase440V,50Hzcylindricaltypecapacitor (Bank) 170 (57.13) Providing& Fixing of IP54 microprocessor based 3CT’s for all 3 phasesensingcompensationpowerfactorcorrectionrelaySize 139mm x 139 mm, Operating Voltage 415/440 V, IEC / EN 61000-6-(2&4)having3CTsensing,sensitivityupto50milliamp secondarycurrent,selfanalysingautoc/ksettingaccordingto targeted power factor setting, the relay shall have digit displayunit fordisplayofrealpowerfactor,targetedpowerfactor,lag/lead capacitorswitchingstatus,alarmoutputforundercurrent,over current, insufficient compensation, communication interface with RS 485,indication of switching onunits, auto/manual status, and shall haveoverloadprotection,novoltrelease,havingmultiparameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and3 no. Class- 0.5 Cast ResinCT ( refer CT specs in this chapter )for sensing the relay includingmakingcoonectionwith1.5Sq.mmcopperwireetc.as required.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 171 (57.13.1) 6 to 8 stage 172 (57.15) Providing&Fixingof440Volt3polecapacitor(AC6B)duty contactor with 3 no. early make and post break auxiliary contacts in serieswithquickdischargedampingresistors/reactorstolimitthe inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1:2000,insulationvoltage1000V,impulsewithstand voltage8KV,Dinrailmountingtypeincludingmakingconnections, testingetc.asrequired.suitableforfollowingcapacitycapacitor bank.All as per pre approved by Engineer in-charge. For additional technicalparametersofproducts/work,referAnnexureA attached with this BSR . 173 (57.15.1) up to 6 KVAR 174 (57.15.3) 10 KVAR 175 (57.15.6) 20 KVAR 176 (57.15.10) 50 KVAR 177 (58.3) SITCof3/4polecurrentlimitingMouldedcasecircuitbreaker (MCCB)madeofflameretardent&heatresistantmaterialhaving followingcurrentrating,shortcircuitbreakingcapacityat440/415 V,50Hz;O/L&S/Csettings,conformingtoIS/IEC60947P-2 :2003withfrontfaceandcentralisedadjustable,tripfree mechanisum,truecontactpositionindicator,lineload interchangeability, designed for both horizontal&vertical mounting withoutanyadverseeffectonelectricalperformance,suitablefor operationupto55degreeandwithoutderatingupto40degree,pollution degree 3, having positive isolation capability, push(test) totrip,triptimelessthen10msunders/ccondition,Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock&rotaryhandle,includingmakingconnectionsetc.as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 178 (58.3.3.9) 630 Amp , 50 kA, adjustable O/L & adjustable S/C setting, 179 (58.4.3) Extended Rotary Handle 180 (58.4.5) Mechanical Interlocking kit 181 (58.4.11) Auxiliary + Trip alarm contact 182 (58.4.20) Spreaders for 630A, 4Pole MCCB 183 (60.2) Providing&LayingP.V.C./XLPEinsulated&P.V.C.sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - Iof1.1KVwithH4-Gradeelectrolyticaluminiumconductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC /Hume/Stoneware/PVCpipe/openduct/cabletrench/Cable tray(withcabletie)includingtestingetc.asrequiredoffollowing size.OEMmusthaveitsowninhouseNABLaccrediated LaboratoryfortestingprocedureasperIS:10810.Foradditional technicalparametersofproduct/workreferAnnexureAattached with this BSR 184 (60.2.14.2) 300 SQMM,3.5 CORE 185 (60.2.6.2) 35 SQMM, 3 CORE 186 (60.2.7.2 ) 50 SQMM, 3 CORE 187 (60.2.9.2) 95 SQMM, 3 CORE 188 (60.2.1.2 ) 4.0 SQMM, 3 CORE 189 (61.5) Supply,Fabricating&installingfollowingsizesofperforatedHot dippedGalvanizedironcabletray(Galvanizedthicknessnotless then 50 microns) with perforation not more then 17.5% in convenient sectionincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended fromtheceilingwithGIsuspendersincludingGIbolts&nuts, fastners,supportsetc.asrequired.Allasperpreapprovedby Engineer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 190 (61.5.1) 100mm x 50mm x 1.6mm 191 (61.5.2) 150mm x 50mm x 1.6mm 192 (62.1) Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4-GradeelectrolyticaluminiumconductorconfirmingtoIS:8130 class-2ofpurity>99.6%,InsulationScreening:Extruded SemiconductingCompoundfollowedbyhelicallywrappedCopper Tape,round/flatstriparmouringofcables,Inner/outersheath PVCtypeST-2confirmingtoIS:5831inexistingRCC/Hume/ Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in houseNABLaccrediatedLaboratoryfortestingprocedureasper IS:10810AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 193 (62.1.1) 3 core 95.0 Sq.mm 194 (62.7) Providing&makingheatshrinkabletypeindoor/outdoor/straight through terminations/ joint kitsuitable for11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test reportshouldbeasperIS13573:2011whichcoveredallsequence fortable2forterminationkitandtable3forstreightthroughjoint inclusive thermal & dynamic short circuittest, humiditytest, soil fog test.CrosslinkingshallbedoneoutsidefactorywithE-beam/ peroxidetechnology.ExtrusionprocessshallbeinhouseOEM withinsamevicinity.includingtestingetc.asrequiredoffollowing sizes. All as per pre approved by Engineer in-charge. For additional technicalparametersofproducts/work,referAnnexureA attached with this BSR . 195 (62.7.1.2 ) 3 core 50/70/95 Sq.mm 196 (62.7.2.2) 3 core 50/70/95 Sq.mm 197 (63.5) Supply&Layingfollowingsizeearthstripinhorizontalorvertical runinsurfacebymeansofEarthstripDMCInsulatorincluding riveting/soldering/welding,Jointingshallbedonebyoverlapping andwith2setofBrass(forCustrip)/GI(forGIStrip)nutbolt& springwasherspacedat50cmmakingconnectionetc.as required.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 (63.5.15 ) 25mm x 6mm G.I. ( Hot Dipped) Strip 199 (63.5.16 ) 32mm x6mm G.I. ( Hot Dipped) Strip 200 (67.1) SupplyanderectionofGalvanizedIronpolewith galvanizingdone insingledipping(AveragecoatingthicknessMinimum65Microns) continuouslytaperedpoleshavingOctagonal/Circularcross-sectionsdesignedtowithstandthemaximumwindspeedasperIS 875,Thepoleshaftshallbemadefromsheetsteel(HTSteel ConformingtogradeS355JO)andconfirmingtoBSEN10025and shall be continuously tapered with single longitudinal welding. There shallnotbeanycircumferentialwelding.Theweldingofpoleshaft shallbedonebySubmergedArcWelding(SAW)process.pole shaftsshallbeprovidedwiththerigidflangeplateofsuitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to thepoleshaftattwolocationsi.e.frominsideandoutside.The octagonalPolesshallhavelockabledoorofapproximate500mm length at the elevation of 500 mmfrom the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) insidethepoleatdooropeningforcableconnectionoffollowing lengthanddimensionaspertableP-01withbaseplateand foundationboltontheExistingcementconcretefoundation.Allas perpreapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexureAattachedwith this BSR . 201 (67.1.1.5) 7 Mtr., Poles with Octagonal Cross Section 202 (67.2) SupplyandFixingofPoleOEMfabricatedhotdippedgalvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure A attached with this BSR . 203 (67.2.1) Single arm overhang 204 (67.8) ProvidingandLayingRCCFoundationforOctagonal/Conical StreetLight poles, High mast Poles as per Drawingattach at TableP-4withFollowingProcedure&Allasperpreapprovedby Engineer in-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . A)ExcavationofPitforFoundationSizeuptorequireddepthfrom Ground levelB)DressingofPitandDrystonepitching200mmthickincluding supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D)ReinforcementforR.C.C.workwithTMTbarsincluding straightening,cutting,bending,placinginpositionandbindingall complete. E)Centringandshutteringincludingstrutting,proppingetc.and removal of form work for Footing and Pedestal F)Providing&Fixingof2no.RequiredSizePLBHDPEPipe& Foundation Bolt with template as per OEM Recommendations. G) Providing and LayingReinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. 205 (67.8.2) Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. 206 (67.12) Providing&FixingofIK08,IP66protectedLEDStreetLight Luminaireonexistingbracket/pole.Fixturemadeofpowdercoated singlepiecepressurediecastaluminummaterialwithheat dissipationfinsonhousingwithUVstabilizedPC(UVstablization reportsubmittedforUVcover)/ToughenedGlasscoverand secondarylensoneachLED&shouldbeSMDtypeof3to5watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with HighvoltageCutoff@>=300VACandAutoresettingSafety, Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. TheluminaireshallbeBIScertifiedandTrademarkcertified.Life ExpectancyEqualormorethan50000burninghrswithMinimum 70%lumenmaintened,CRI>70andCCT5700K+355K.Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside drivercompartment.drivershouldbePhasetophaseprotectionof 440Vfor4Hrs.ManufacturesWordMark/Name Engraved/Embossingondiecasthousingtoallow traceability/authenticity.FixtureshallbeASPERIS10322 Complianced.OEMMusthaveitsowninhouseNABLlabsetupfor alltestingfacilitiesforLEDfixtures.(LM79/LM80)Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 207 (67.12.5 ) LED Street Light fixture with Minimum lumen output 8700 lm 208 (67.19) Providing&FixingofIP-65protectedimpactresistant polycarbonate/Polystereneenclosureswithknockoutforcable entry/outincludingfixingwithnut,bolt,fatneretcasrequired complete in all respect of following sizes.All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 209 (67.19.1 ) 180 x 180 x 91 mm 210 (67.11) Providing&FixingofIK08IP-66protectedhighpowerLEDflood lightsystemwithsinglepiecePressurediecastaluminiumhousing, toughenedglassdiffuserwithsuitablelensesonLEDtoachieve variousbeamangles,ofhighpowerLEDof3to5watteach. Integrated potted driver as a unique BIS R numberhaving efficiency more than 85 % and in compliance to BIS certified and Trade markcertificate.TheSystemlevelLuminaireefficacy>=125lm/wt.LED driverInputVoltageAC120to270VACwithHighvoltageCutoff @>=300VACandAutoresettingSafety.PowerFactor>0.95, THD(I)<10%,drivercurrent<=750mA.drivershouldbePhaseto phaseprotectionof440Vfor4Hrs.ElectricalConnector,Surge ProtectionMin>=4KVinternaland10KVexternalbutinsidedriver compartment, System life of 50000 Burning hours with 70% of Initial Lumensmaintained,CRI>70andCCT5700K±355K.ManufacturesWordMark/NameEngraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shallbeIS10322Complianced.OEMMusthaveitsowninhouse NABLlabsetupforalltestingfacilitiesforLEDfixtures.(LM79/LM80)Certificate/reportwithliablewarrantyof product/accessoriesfromOEMshallbesubmitted.Allasperpre approvedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexureAattachedwith this BSR . 211 (67.11.4 ) High Power LED Flood Light Minimum lumen output 10000 lm 212 (67.18) Providing&FixingofStreetlightbracketmadeoutfromfollowing size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. asrequired.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 213 (67.18.3) 32 mm Dia. 214 (72.2) SITCofstarratedAluminiumwounddistributionTransformerof followingrating11/0.433KVDelta-StarConnected,VectorGroup Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS2026-1977&lossesasdefinedasper2014(FourthRevision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise inwinding/oil 35-40 degree C upto 200 KVA& 40-45 degree C forabove200KVA,ISImarkeddrainvalve,DialtypeTemperature gauge,firstfillingoftransformeroilasperIS:335-1953,Epoxy basedpaint,includingcarryingofpre-commissionTesting& Charging of Transformer complete in all respect . TheTransformershallbesubjectedtoroutinefactorytests(asper IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from ElectricalInspectorateofficeasperIndianElectricityrule,(CTL testingchargesandElectricalInspectionchargesshallbe reimbursedbythedepartmenttothecontractor).Allasperpre approvedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexureAattachedwith this BSR . 215 (72.2.7) 400 KVA with Off -LTC (+5% to - 10% @ 2.5%) 216 (72.4) Supply&InstallationofD.P.StructureWithAIRBREAKSWITCH having following specifications A, B, C, D, E. All as per pre approved byEngineerin-charge.Foradditionaltechnicalparametersof products/ work, refer Annexure A attached with this BSR .A)Doublepolestructureon2noISMB(Ibeam)of size150x75 mm, 10 mtrlengthusing7noMSchanneleachofsize100mmx 50mmx2500mmcompleteinallrespectwithnuts,springs washers, clamps as required. B)Offloadtypegangoperated3-poleverticalflutetypeswitch suitablefor11KV;400A,3-ø,centralpostrotatingdoublebreak isolator complete with MS hardware , copper moving & fixed contact ,assemblyof9nospininsulator,GIpipeofsuitablelengthfor operation. C) 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators D)3piecenonlinearresistortype.lightingarrestorofapproved makesuitablefor3wire,11kvOverheadlinewith ratedvoltageof 9kv rms & nominal discharge current rating of 5 ka & complete with galvanizedclampingarrangementGIbolts,nuts,washeretcas required. E)3no11kvACSRconductorsmountedonpintypeinsularorsas required.6.GENERAL:Thegoshallbeoperatedbyhandoperated liver properly earthed with provision for locking mounted at 3’ 217 (72.16) SITCofHTmeteringcubicalpanelasapprovedByDISCOMs fabricatedout of18SWG CRCAsheet steelintwocompartment& MSangleofsize60mmX6mmhavingprovisionforFollowing: (i)ProvisionforfixingTrivector/Import-ExportMeter(Tobe supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set withCopperstripforConnection(TobesuppliedbyDISCOMs), (iii)Test terminal Block, (iv) 6mm thick Bakelite sheet on all sides, (V) 3/6 corex 1.5 / 2.5 Sq.mm copper cable for interconnections,etc. as required.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 218 O&M 219 (Rates are approved byCE (U&NRW) PHED Jaipur vide letter No. 11615-617 dt. 6-12-2024) Operation and maintenance of Rising main, Distribution network, OHSR, Tubewell, Pumping Machinary etc. created under Amrut 2.0 of UWSS for a period of Five Years as per scope of work. 220 1st year 221 2nd year 222 3rd year 223 4th year 224 5th year

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 18-02-2025 Corridendum 1 Technical Bid 16-03-2025

Key Value

Document Fees
INR 10000 /-
EMD
INR 2090400.0 /-
Tender Value
INR 10.45 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail