Tender For Replacement Of Pumps And Pipelines Of Pump House At Rangmahal Pumping Station Under City Sp Zone., Delhi-Delhi

Municipal Corporation Of Delhi has published Tender For Replacement Of Pumps And Pipelines Of Pump House At Rangmahal Pumping Station Under City Sp Zone.. Submission Date for this Tender is 17-02-2025. Pipe Laying Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

47658505
Tender For Replacement Of Pumps And Pipelines Of Pump House At Rangmahal Pumping Station Under City Sp Zone.
Open Tender
Indian
Delhi
Delhi
17-02-2025

Tender Documents

Tender Details

Tender For Replacement Of Pumps And Pipelines Of Pump House At Rangmahal Pumping Station Under City Sp Zone.; 1 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS3589/IS1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/ support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 2 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS3589/IS1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 3 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS3589/IS1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :300 mm dia (wall thickness 7.1 mm) 4 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN1.6 with non rising spindle, bronze/gunmetal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :80mm dia 5 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN1.6 with non rising spindle, bronze/gunmetal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :150 mm dia 6 Providing, installation, testing and commissioning of non-return valve of following Sizes confirming to IS:5312 complete with rubbergasket,GIbolts,nuts,washers etc.as required :80 mm dia 7 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 8 Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep 9 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes 10 S/I/T/C of cubical type control panel board for three phase star delta starter, three position selection with auto switch for Mono submersible pumping set of following rating complete with single phasing preventer in auto, contactor(25Amp),O/L relay TP, MCB, Voltmeter, ammeter, VSS and indication lamp etc. including lamp etc. including connection etc. as required.(b)15H.P.rating Submersible Pump Set Over Load relay (range30-32 Amp) & Contactor (range 32 Amp) 11 S/I/T/C of cubical type control panel board for three phase star delta starter, three position selection with auto switch for Mono submersible pumping set of following rating complete with single phasing preventer in auto, contactor (40Amp),0/L relay TP, MCB, Voltmeter, ammeter, VSS and indication lamp etc. including lamp etc. including connection etc. as required. - 20 H.P. rating Submersible Pump Set Over Load relay (range23-40 Amp) & Contactor (range 40 Amp) 12 S/I/T/C of fully Automatic Autotransformer starter will be made out/fabricated with 2 mm thick ,MS Sheet steel ,dust & vermin proof, dam & drip-proof, front operated, self supported, free standing type constructions and will be duly spray painted synthetic Enamel paint of light grey shed 631 of IS:5 and accommodate all witch gear items required to meet the technical requirements of ATS 50 HP & Adequate rating oil immersed Auto Transformer having copper winding ,class E insulation with taping 50%, 65% & 80% (01 No.),Adequate rating power contactors ,over load relay ,single phase preventer relay with under voltage & over voltage OR as suitable(01No.), flush mounting type Ammeter 96 sq.mm with selector switch (01 No.), indicating lamp for ON,OFF,TRIP (03 Nos.),indicating lamp for R,Y,B (03 No.) without Transformers oil ,as follows ;(1). Switch fuse unit 125A TPN with Handle FN125A-01No.(2).HRCFuse125A-3Nos.(3) star contactor coil voltage 240AC with 2No.+2NCAUX.contacts BlockMNX50-1No.(4).TAP contactor coil voltage 240 AC with 2 No. + 2 NC AUX. contacts Block MNX 80 -1 No. (5) Line contactor coil voltage 240 AC with 2 No. + NC AUX. contacts Block MNX 80- 1 No. (6) over load relay range - A CT operated 45- 75 MNS -01 No. (7) Current Transformer 15 VA ,CL . 1 for metering 100/5A - 3 No. (8) Push Button start/stop element 22.5 mm dia.- 2 Nos. (9) indicating lamps 230 V AC Red LED Type -3 No. .(10) .MCB 6A 1P MCB,10 kA - 1 No. (11) on delay Timer 0-30 Sec., Coil Voltage 240V,AC2AODTS-3Nos.(12)Ammeter,0-100/5a,(100-600A)Sappressscale6- Time , 96 sq.mm with Ammeter selector switch 0-100/5A -1 No. (13). Voltmeter 0- 500V ,96 SQ.MM size with voltage selector switch S96 -1 No. (14). Single phase preventer relay with under voltage S2VMR2-1 no. 13 SITC of Horizontal Centrifugal Pump set with Non-Clog, Solid handling impeller to handle storm/mixed/sewage water having minimum Discharge of 200m3/hr at Head- 15 Mtrs, RPM-1450 RPM (ind.) having suction and delivery size (125mm and 100 mm dia respectively) mounted on a common base frame coupled with Min.25 HP or suitable rating three phase, 415 volt, 50 Hz supply electrical motor complete as required M.O.C. as Packing: Gland Casing-CI, Impeller-C.I., SHaft - 40C8 complete with tyre coupling, coupling guard and foundation bolts 14 SITC of Horizontal Centrifugal Pump set with Non-Clog, Solid handling impeller to handle storm/mixed/sewage water having minimum Discharge of 350m3/hr at Head- 20 Mtrs, RPM-1450 RPM (ind.) having suction and delivery size 150mm dia mounted on a common base frame coupled with Min.40 HP or suitable rating three phase, 415 volt, 50 Hz supply electrical motor complete as required M.O.C. as Packing: Gland Casing-CI, Impeller-C.I., SHaft - 40C8 complete with tyre coupling, coupling guard and foundation bolts 15 Supply of XLPE insulated PVC sheathed Al.Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3C*70 sqmm 16 Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3C*95 sqmm 17 Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*400 SQMM 18 Supply,Installation,testing and commissioning of power distribution board made out of 1.6 mm sheet steel, epoxy powder coated, specially designed Al bus bar 400A to 630A with heat shrinkcable colour coated sleeves suitable for accommodating MCCBs/MCBs /Isolators as incoming and outgoing as required (without MCCBs/MCBs/Isolators ) complete with digital meter module, including Voltmeter Ammeter with selector switch, CTs control fuse and indicating lights including connections etc. as required ( Conforms to IS:8623) 19 SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specificationasreqdwithIP66protection(a)Totalsystemwattage=150watt+/-5% (b)LuminaireEfficacy>=100Lm/w(c)PowerFactor>=0.95(d)Protection Class- IP-66 20 S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a)Total system wattage 20watt+/-5%(b)Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95 21 Providing and fixing following rating and breaking capacity and pole MCCBwith thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 Amp, 16 KA, TPMCCB 22 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 Amp,16 KA,TPMCCB 23 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board Including drilling holes in cubicle panel, making connections, etc. as required. 400 Amp, 35 KA,TPMCCB 24 Earthing with G.I.earthpipe 4.5metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. 25 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I.nut, bolt, spring, washer excavation and re- filling etc. as required. 26 Providing and fixing 25mmX5mm G.I. strip on surface or in recess for connections etc. as required. 27 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVCsheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 70 sq. mm (35mm) 28 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVCsheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 95 sq. mm (38mm) 29 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 30 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35sq.mm and upto 95 sq. mm 31 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 185sq.mm and upto 400 sq. mm 32 Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35sq.mm and upto 95sq. mm (clamped with 25x3mm MS flat clamp) 33 Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above185sq.mm and upto400 sq. mm (clamped with 40x3mm MS flat clamp) 34 Supplying and installing following size of perforated pre-painted M.S.cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness 35 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 36 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25 mm 37 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. 3x2.5 sq. Mm 38 Supplying and fixing metal box of 180mmX100mmX60mm deep (nominal size)on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 39 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator8 way, Double door 40 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 41 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 42 Providing and fixing 6SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 43 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 44 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level:1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 45 Steel work welded in builtup sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 46 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 47 Supply of 15(380mm) sweep 1400 rpm exhaust fan heavy dutycompletewith shutter, blade etc as required. 48 Supply of Submersible Sewage Pumps 15 HP/11KW /3 PHASE/1450 rpm ,Head 15 Mtr discharge 2700lpm, 150mm Hose outlet, Solid Handling:100mm casting:Cast Iron ASTM A48 Class 30 (FG 200) IMPELLER : Cast Iron ASTM A48 Class 30 (FG 200) Class 30 (FG 200) SHIFT : 431 stainlss Steel Hardware : 304 Stainless steel,O-Rings: Nitride Rubber, Mech. Seals : TC /TC (Upper & Lower) with water proof/oil proof, EPR insulated, single sheathed copper conductor flexible cable fitted with strain relief grip, 15 Mtrs length,size 7 core 4 sq. mm + 2 core 1 sq.mm( 9 core cable) 49 P&F of on load changeover switch four pole in Existing cubical panel with advance neutral confirming to IS:13947(PART3)including drilling holes in cubical panel, making connections , etc complete as required of 250 A 50 SITC of 15 HP Sewage submersible Pump with the help of Heavy Duty Labour

Key Value

Document Fees
INR 1180 /-
EMD
INR 94709.0 /-
Tender Value
INR 47.35 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail