Tender For Construction Of 200Mm Dia Tube Well And Commissioning Of Sub. Motor Pump And Providing , Laying , Jointing Pipe Line At Rwss Bansi (At Kala Gora Ki Bawadi) - 1 construction of Tube Well 2 Construction of Tube Well up to 100 mtr. depthin all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. 3 Nominal bore 200 mm dia. 4 Add 15% extra on above item for drilling depth beyond 100 mtr and upto 200 mtr from ground level, Rates shall be applicable for only extra depth beyond 100 mtr upto 200 mtr. 5 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes 6 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) 7 Labour charges for making slots on blank pipes made of ERW MS Black pipe ISI marked of following sizes, the slotting should beas per IS: 8110-1985 8 200 MM Dia nominal bore of 5.4 mm thickness 9 Supply & Installation of 3 phase ISI marked submersible motor pump set offive star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 10 9.3 KW(12.5 HP)&head upto 120 mtr 11 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 12 above 10 HP & up to 15 HP 13 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 14 3 core 6.0 Sq.mm 15 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 16 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. 17 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 18 200 mm dia 19 Providing & Lowering in tube well ISI marked GI Pipe “B class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 20 50 mm dia 21 Providing,installing,testingandcommissioningofdoubleflangedbulkflow meterwithremovablemechanism,ofclassBconformingtoISO4064/1or amendeduptodateofapprovedmakeincludingcostofallmaterialand labouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. 22 50 mm dia 23 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 24 16.0 Sq.mm, 4 core 25 Providing and Fixing of ISI marked PVC storage tank of following capacity as per IS: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long GI overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket, including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and PVC ball complete with brass weight 1000 gm, including P&F 15mm dia CI quarter turn heavy duty Bib Cocks four nos of superior quality and approved make, including interconnections complete job. 26 2000 litres capacity 27 Fabrication & Fixing M.S. Stand of specified class of angle iron L-shaped of 50mm size with four legs grouted by 300*300*300 mm CC Block M-15 in the ground and all legs tied up with each other through same size of angle iron along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. PVC tank complete in all respect. 28 Pipe line 29 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 30 Dismantling of cement concrete pavement for pipeline and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding .02 cum in volume and stock piling at designated locations and disposals of dismantled materials upto a lead of 1000 mtrs. Measurements for dismantled trench to be made as per standard trench width specified in tender document and no extra payments shall be made for trench width moe than specified rehandling of material/earth to comp;ete the tasks as per technical specification and scope of work. 31 Providing and laying in position cement concrete M-10 grade nominal mix 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggreagate 40 mm nominal size) in base course complete including all material , labour, machinary, lighting, grading for road restoration. Work in trenches of pipeline and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified complete work as per technical specification and scope of work. 32 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material labour , machinary, lighting, grading for road restoration. Work in trenches of pipeline and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified complete work as per technical specification and scope of work. 33 M20 grade Nominal Mix 1:1.5:3 ( 1 cement: 1.5 coarse sand : 3 grade stone aggregate 20 mm nominal size) 34 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 35 HDPE PE-80PN-10 36 110mm