}

Tender For Lan Work In Rheumatology Lab At Sms Hospital, Jaipur, Jaipur-Rajasthan

Public Works Department has published Tender For Lan Work In Rheumatology Lab At Sms Hospital, Jaipur. Submission Date for this Tender is 10-02-2025. LAN Tenders in Jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

47531730
Tender For Lan Work In Rheumatology Lab At Sms Hospital, Jaipur
Open Tender
Indian
Rajasthan
Jaipur
10-02-2025

Tender Documents

Tender Details

Tender For Lan Work In Rheumatology Lab At Sms Hospital, Jaipur- 1 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 25 mm 3 Supplying and drawing coaxial cable 75 ohm impedance with foam PE insulated solid bare copper inner conductor, and Ist outer conductor of bonded alum. tape and second outer conductor ofalum. alloy braidin existingsurface or recessed conduit/casing capping including making connections as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 4 RG - 6 5 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 6 2 pair 7 10 pair 8 Supply and laying PVC Insulated and PVC Round Sheathed Multi Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 9 1.5 sq.mm x 3 core 10 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 11 RJ-11 telephone jack singleline 12 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 13 1/2 Module 14 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 15 1-2 Module 16 Providing & Fixing of ISO certified company made virgin material PVC trunking systemas per PWD specification for electrical Works, with double lock feature for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall haveadaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM shall have submitNABL accrediated /CPET lab test reportsbefore execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 17 32mm X 20mm 18 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 19 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 20 Cat 6, Un-sheilded Information Outlet 21 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 22 Single Aperture 23 Dual Aperture 24 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25 Modular Patch Panel Loaded with Cat -6 I/O 26 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 27 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 28 1 Mtr 29 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 30 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 31 15 U Rack with Width 600 mm & Depth 400 mm + 100 mm 32 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 33 Supply and Laying of 2 Core size 0.5 sqmm copper shielded Cable for connectings Microphones with related conduits / fittings / termination, etc complete in all repsect. All repsect all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with P.W.D Electrical B.S.R.2022. . 34 Supply, laying and commissioning of PVC insulated and PVC sheathed , 2 core shielded flexible copper wire of size 1.5mm, in existing Surface /recessed conduits ,Cable race ways, Trenches including cost of excavation and refilling, existing Pipes etc using all saddles, clamps, fasteners glands, lugs. etc complete in all repsect. All repsect all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with P.W.D Electrical B.S.R.2022. . 35 Supply, Installation, Testing and Commissioning of Handheld Wireless Mic with Cardiod polar pattern for transmitter, Dynamic microphone with Neodymium magnet , Receiver frequency response 80Hz- 18kHz,Receiver RF sensitivity 1.0 µV, Receiver Image rejection 55dB, Receiver Dyanmic range 95dB and receiver having 32 channels possible, Receiver S/N ratio 100dB A, distortion 1 %, Transmitter sensitivity - 3.2 mV/Pa,modulation:+/-40kHz etc complete in all repsect. All repsect all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with P.W.D Electrical B.S.R.2022. . 36 Supply and Installation of 240 Watt Mixer Amplifier Unit- for providing a crisp call or clear music with 4 microphone / line inputs, plus music source input, announcement only output, 3 wire volume override, with Mains power supply 230 VAC ±10%, 50 Hz (reduced power at lower mains), Inrush current 20 A , Power consumption 120W, Frequency response (Line) 80 Hz to 18 kHz (+1/ 3 dB @ 10 dB ref. rated output) Frequency response (Mic.) 80 Hz to 18 kHz (+1/ 3 dB @ 10 dB ref. rated output) Distortion 1%@ rated output power, 1 kHz Bass Control Max. ± 8 dB Treble Control Max. ± 8 dB, including making connection etc complete in all repsect.All repsect all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with P.W.D Electrical B.S.R.2022. . 37 SITC of 30 Watt speaker with taping facility having frequency range of 65Hz- 20KHz@(-10db) with power handing of 200Watt continuous and more than 350 Watt @peak. etc complete in all repsect.asAll repsect all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with P.W.D Electrical B.S.R.2022. . 38 SITC of Cable locking clamps are used with extension cables to prevent accidental disconnectionas. etc complete in all repsect. All repsect all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with P.W.D Electrical B.S.R.2022. 39 SITC of Cable Connectors. Of various types and sizes suitable for system etc complete in all repsect.All repsect all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with P.W.D Electrical B.S.R.2022. . 40 Supply, Installation, Testing and Commissioning of Extension cables and connectors for contribution units. etc complete in all repsect.All repsect all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with P.W.D Electrical B.S.R.2022. 41 Supply, Installation, Testing and Commissioning of Control Unit with inbuilt recorder with Intuitive touch- buttons on the front panel for easy configuration and operation purposes. Intuitive LED indicators for clear and immediate feedback on the system settings . Web browser control it shall be possible to use a web browser application to view and manage system settings. System control for up to 80 Discussion Devices .Hot swap of Discussion Devices, without having to power down the system. Plus/minus buttons and green LED indicators for setting the volume range of all connected Discussion Devices. Microphone- mode selection button and green LED indicators for selecting one of the following microphone operating modes: ‘open mode’, ‘override mode’, ‘voice activation mode’, and ‘push to talk (PTT) mode’. Number of Open Microphones (NOM) button and green LED indicators for selecting the number of microphones that can be activated at the same time. It shall be possible to select up to four open microphones at the Control Unit. Built-in Digital Acoustic Feedback Suppression (DAFS). USB connector on front of unit for connecting a USB memory stick Gain reduction due to number in all repsect.All repsect all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with P.W.D Electrical B.S.R.2022. 42 Supply, Installation, Testing and Commissioning of Digital Delegate Unit with Speak Button and Discussion Device that shall enable participants to take part in a discussion by speaking into a microphone and listening to proceedings on a loudspeaker. The device shall have Plug-and-play functionality, Compact, attractive, ergonomic design, with LED indicator in the Discussion Device and in head of microphone with flexible stem with Loudspeaker integrated into front of device having facility of headphone as well with Automatic level reduction when microphone is activated (configurable via web browser application of Control Unit): prevents acoustic feedback from headphone to microphone. GSM immunity with having Frequency response 200Hz 12.5kHz, Loudspeaker nominal output 72dB SPL. etc complete in all repsect.All repsect all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with P.W.D Electrical B.S.R.2022. 43 Supply, Installation, Testing and Commissioning of Digital Chairman Unit with Priority Button and Discussion Device that shall enable participants to take part in a discussion by speaking into a microphone and listening to proceedings on a loudspeaker. The device shall have Plug-and-play functionality, Compact, attractive, ergonomic design, with LED indicator in the Discussion Device and in head of microphone with flexible stem with Loudspeaker integrated into front of device having facility of headphone as well with Automatic level reduction when microphone is activated (configurable via web browser application of Control Unit): prevents acoustic feedback from headphone to microphone. GSM immunity with having Frequency response 200Hz 12.5kHz, Loudspeaker nominal output 72dB SPL. etc complete in all repsect.All repsect all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with P.W.D Electrical B.S.R.2022. 44 Supply Installation Testing & Commissioning of 10 KVA(3/3)Floor Mount Online UPS with Integrated Isolation Transformer at UPS Input, IGBT Rectifier Technology, InBuilt Isolation Transformer, >0.99 I/P Power Factor, 330-470 VAC I/P Voltage Range @ rated Load, 46-54 HZ I/P frequecy, 0 to 40 Degree Operation Tem, upto 93% Double Conversion Efficiency, 240V DC Voltage, Manula & Automatic bypass (Both inbuilt), LCD Display showing UPS parameters, AUDIBLE ALARM: Mains Failure alarm, Low Battery alarm, UPS warning, Overload, Fault & Bypass mode, 42AHx 20 Nos SMF Batteries, PHASE SEQUENCE CORRECTOR: Should be Inbuilt, O/P Voltage: 415 V, DURING MAINS -VOLTAGE VARIATION (Static):+/-1% (Should not be more than specified values),OVER LOADING: upto 150% for 60 Sec & upto 125% for 10 min, UPS should be GenSet Compatible, ISO 9001, ISO 45001 and ISO 14001 Certification, BIS (In name of UPS OEM), ROHS, Type Test Report of the Product Series, MS Rack with Battery Breaker Required, All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with PWD Electrical BSR 2022. 45 Supply , installation ,Testing & Commissioning of high-performance19.5 meter HDMI Male to HDMI Male cable that supports signals up to 4k@60Hz(4;4;4), Deep color Should have Gold Plated pins Should have lockable connections Should be of same Make of Switcher, Scaler, Wall plate for the interoperability coplete in all respect,All as per pre approved by Engineer in charge for additional technical parameters of products/work, refer AnnextureA attached with P.W.D. Electrical B.S.R. 2022.

Key Value

Document Fees
INR 500 /-
EMD
INR 34700.0 /-
Tender Value
INR 17.35 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail