}

Annual Plan-Vazhoor Bp Project No-S0159/25-Electrification Work To Kanjirappally General Hospital-General Electrical Work - Electrification Work To Kanjirappally General Hospital General Electrical Work , Electrification Works To Kanjirappally General Hos, vazhoor-Kerala

Rural Development Department has published Annual Plan-Vazhoor Bp Project No-S0159/25-Electrification Work To Kanjirappally General Hospital-General Electrical Work - Electrification Work To Kanjirappally General Hospital General Electrical Work , Electrification Works To Kanjirappally General Hos. Submission Date for this Tender is 06-02-2025. Electrification Work Tenders in vazhoor Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

47474567
Annual Plan-Vazhoor Bp Project No-S0159/25-Electrification Work To Kanjirappally General Hospital-General Electrical Work - Electrification Work To Kanjirappally General Hospital General Electrical Work , Electrification Works To Kanjirappally General Hos
Open Tender
Indian
Kerala
Vazhoor
06-02-2025

Tender Documents

Tender Details

Annual Plan-VAZHOOR BP Project No-S0159/25-ELECTRIFICATION WORK TO KANJIRAPPALLY GENERAL HOSPITAL-General Electrical Work - Electrification Work To Kanjirappally General Hospital General Electrical Work , Electrification Works To Kanjirappally General Hospital(List Of Materials Used For The Work Approved By The Dltce Under Lsgd Kottayam Is Attached Separate Document) , 90.2.1.1:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Db'S Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Rohs Compliant Modular Accessories).Single Control Light Point With 6A, Plate Ceiling Rose - Short Point , 90.2.1.4:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Db'S Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Rohs Compliant Modular Accessories).Single Control Ceiling Fan Point With 6 A, 3 Plate Ceiling Rose & With Socket Size Stepped Electronic Regulator. - Short Point , 90.2.1.3:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Db'S Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Rohs Compliant Modular Accessories).Single Control Light Point Without Ceiling Rose - Short Point , 90.2.1.6:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Db'S Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Rohs Compliant Modular Accessories).Combined Plug Point With 6 A, 5 Pin Plug Socket Controlled By 6 A, Switch In The Same Switch Board As That Of Light Points , Od265561/2024-2025:Supply And Fixing Angle/Straight Brass Linked Skirt Type,Bakelite Batten Holder With 9W Led And Giving Connections Etc As Required. , 90.3.22.3:Supply & Installation Of Light Fittings On Flat Iron Bracket ≪Br≫ Supply, Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made Of Crca Sheet Of .5Mm Thickness Complete With All Accessories Andlamps Etc. Directly On Wall Using 2 Nos. Flat Iron Brackets Made From 25X6mm Flat Iron, Painting The Flat Iron Bracket And Giving Connections With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss Or Extending The Original Wiring And Giving Connection Etc. As Required.1200 Mm 1X20w Led Lamp With Box Type Fixture , 90.3.20.3:Supply & Installation Of Light Fittings On Tw Round Block ≪Br≫ Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thicknesscomplete With All Accessories Andlamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200 Mm 1X20w Led Lamp With Box Type Fixture , 90.4.2:Supply And Installation Of Suitable Size Ms Belt Type Fan Clamp Fabricated From Flat Iron 40 X 6 Mm, 150Mm Long X 2 Nos With M.S. Rod Bent To Shape, Neatly Painted With 2 Coats Of Enamel Paint Over A Coat Of Red Oxide Primer As Per Is 732 As Required. , 1.48:Supplying And Fixing Extra Conduit Down Rod Of 20 Cm Length G.I. Pipe 15 Mm Dia, Heavy Gauge Including Painting Etc. As Required. (Note : More Than 5 Cm Length Shall Be Rounded To The Nearest 10 Cm And 5 Cm Or Less Shall Be Ignored) , 90.4.5.4:Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply , Od265635/2024-2025:Supply And Installation Of 150Mm Medium Duty 2300Rpm,4 Leaf Exhaust Fan In Metal Frame (Almonard/Crompton Make) In The Existing Opening,Fixing Necessary Bolt And Nuts,Making Good The Damages Etc.As Required Including Giving Connections With Required Lenght Of 24/0.20 Mm 3Core Round Copper Conductor Flexible Chord Etc. As Required. , 90.4.8:Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Colour Washing Etc. As Required. , Od265583/2024-2025:400 Mm Sweep Wall Mounting Fan With Metal Body And Leaves , 1.24.5:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet , 1.27.5:Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.8 Module (125Mmx125mm) , 1.24.4:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5/6 Amp Socket Outlet , 1.27.4:Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.6 Module (200Mmx75mm) , 1.27.3:Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.4 Module (125Mmx75mm) , 1.27.2:Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75mm) , 1.27.1:Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module (75Mmx75mm) , 1.27.6:Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.12 Module (200Mmx150mm) , 1.34:Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required. , 1.33:Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connection Etc As Required. , 1.26:Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , 1.24.3:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch , 1.24.1:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amps Switch , 2.10.4:Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, &Quot;C&Quot; Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole , 2.12.1:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , 2.16:Supplying And Fixing Dp Sheet Steel Enclosure On Surface/ Recess Along With 25/32Amps 240 Volts &Quot;C&Quot; Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. , 2.10.3:Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, &Quot;C&Quot; Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Double Pole , 2.15.2:Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , 2.3.3:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcbirccb/Isolator12 Way, Double Door , 2.11:Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. , 2.13.1:Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , 2.10.1:Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, &Quot;C&Quot; Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , 2.15.3:Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps , 2.14.2:Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , 2.13.2:Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps , 90.11.1.10:Supply And Installation Ofsheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required4 Way (8+12) - Three Phase Double Cover (Ip 42/43) , 90.11.1.14:Supply And Installation Ofsheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm (10 Swg) , 90.16.2.2:Supply And Laying Of The Following Sizes Of B Class Gipipe Laid 0.6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc, As Required.20 Mm Dia. G.I Pipe ( Medium Class) , 90.15.4.5:Supply Conveyance, Installation, Testing And Commissioning Of 40W Led Flood Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing, Acrylic Cover Complete With Thd Less Than10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) , 90.16.1.2:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.65 Mm Copper Conductor (12 Swg) , 90.16.5.2:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm (12 Swg) , 90.16.1.1:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg) , 90.16.5.1:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.00 Mm (14 Swg) , 90.3.17.1:Supply, Conveyance And Erection Ofthe Following Sizes Of 'B' Class Gi Pipe In Single Section For Post Top Lantern Of All Types On Concrete Base (Excluding Charges For Concrete Base And Excavation) And Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer Etc. As Required.32 Mm Dia Gi Pipe , 90.6.10.2:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required25 Mm , 90.6.10.1:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 9.1.1:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.2 X 6 Sq. Mm (19Mm) , 90.12.7.2:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.2 Core 6 Sq Mm With Factory Made Clamp , Od268912/2024-2025:Earthing With G.I.Earth Plate 600Mmx600mmx6mm Thick With Watering Pipe 1.7 Metre Long And Test Joint Using 2 Nos,25X3mm Gi Strip With Sufficient Drilled Holes Minium Size 25 Cm Suitably Shaped And Tightly Clamped To The Watering Pipe Using 25X6 Mm Steel Bolts Nut And Washer And Providing 2 Nos,20X3mm Gi Strip From Tet Joint To Earth Plate Bottom Level Clamped At 2 Locations On The Plate And On The Test Joint Bolted With Steel Bolts,Nuts Etc.Provid.Ing Gi Funnel Welded With The Watering Pipe And Making Masonry Chamber Built With Bricks And Duly Plastered And Providing Cast Iron Cover Plate Etc Complete. , 1.17.3:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 1.5 Sq.Mm , 1.17.12:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 2.5 Sq. Mm , 1.17.22:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 4 Sq. Mm , 1.25:Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Od270989/2024-2025:Supply And Providing 25X6mm Brass Bolt And Nut With Washers On The Existing Ms Box/Earth Bus Etc.As Required Including Drilling Necessary Holes As Required. , Od270992/2024-2025:Supply And Providing 12X3mm Brass Bolt And Nut With Washers On The Existing Ms Box/Earth Bus Etc.As Required Including Drilling Necessary Holes As Required. , 90.15.4.3:Supply Conveyance, Installation, Testing And Commissioning Of 70W Led Street Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing,Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) , 1.17.21:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 4 Sq. Mm , Od272708/2024-2025:Supply And Installation Of Fire Extinguisher Dry Chemical Powder(Abc) Stored Pressure Type 6Kg As Per Is:15683 With Isi Mark And With Initial Charger And Installation Brackets. , 90.12.9.2:Supplying, Laying And Jointing Of The Following Sizes Of Double Wall Corrugated (Dwc) Pipes Made Out Of Hdpe Conforming To Is 14930 Part Ii For Mechanical Protection To Underground Power Cables With All Required Accessories In Ground In The Existing Trench50/38 Mm Or Nearest Size , 9.1.34:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 25 Sq. Mm (28Mm) , 90.12.7.42:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 25 Sq Mm With Factory Made Clamp , 90.12.6.42:Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.4 Core 25 Sq Mm , 90.12.10.2:Supply & Laying Of Dwc Pipe In Ordinary Soil 0.75M Below Ground Level Including Excavation50/38 Mm Or Nearest Size

Key Value

Document Fees
INR 640 /-
EMD
INR 7261.0 /-
Tender Value
INR 2.90 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail