Tender For On Occassion Of Mahakumbh 2025, Road Safety Work On Lucknow-Varanasi Road- Signage Work - Providing and applying 2 Component Cold Plastic Paint rolled on surfacing material solvent free, High build two pack seamless, tough, skid resistant, material which has property of attaining 1.5mm - 2.00mm thickness in single coat application Red (or as required colour) based on glass and colour retaining Acralic cross linking resin system for coloured road surfacing including surface cleaning and cost of all material etc. material laying process will be done manually. All-inclusive on bitumen surface, work shall carry out as per IRC 35-2015 clause 2.2), Glass beads as per BS6088 and 1.5 Reflective index(250 gram per sqm). 2 Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 upto date. The finished surface to be level, uniform and free from streaks and holes. as Per SOR Ch-26 SI No.-2 3 Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply and fixing of raised pavement marker with Made of Plastic body of RPM/ Road Stud shall be moulded from ASA (Acrylic Styrene Acrylonitrite) or HIPS (High-Imoact Polystyrene) or Acryloniitrite Butadien Styrene (ABS) or Any other suitable material approved by the Engineer. The Marker shall support a load of 13,635 kg tested in accordance with ASTM D4280.The Reflective panels shall consist of number of lenses contatning single or dual prismatic cubes capable of providing total internal reflection of the light entring the lens face. Lenses shall be mouled of methyl methecrylate conforming to ASTM D788 of equivalent. The slop or retro-reflecting surface shall preferably be 35+/-5 degree to base and the area of each retro -reflecting surface shall not be less than 13.00 sq.cm. the marker height shall not be less than 10 mm and shall not exceed 20 mm & Width shall not exceed 130 mm. The base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name , trade or other means of identification of the manufacture. epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel , to the Engineer . In addition , a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers. In case the markers are displaced , damaged , get worn out or lose their reflectivity compared to stipulated standards , the contractor would be required to replace all such markers within 15 days of the intimation from the Engineer , at his own cost. The rate shall include all materials, labour, T&P, transportation,installation and incidentals all complete as per direction of the Engineer-in-Charge. as Per SOR Ch.25 Item no.5 4 The Solar studs shall be made of aluminium alloy and poly carbonate material which shall be absolutely weather resistant and strong enough to support a load of 13.635 kg tested in accordance with ASTM D4280. Its colour may be white, red, yellow, green or blue or combination as directed by the Engineer. Its water resistance shall meet the requirements of IP 65 in accordance with IS: 12063 : 1987 category 2 for protection against water ingress. The dimensions of solar studs shall not be less than 100 mm x 100 mm x 10 mm. It shall have super bright LEDs so as to provide long visibility from a distance of more than 800m. Its flashing rate shall not be less than 1 Hz. Its shaluld be able to give the prescribed performance in the temperature range of - 40oC to+55oC. Its life shall be not less than 3 Years. The rate shall include all materials, labour, equipments, fabrication, transportation, erection, installation and incidentals all complete as per direction of the Engineer-in-charge. as per SOR Ch-26 SI No.-16 5 Supply & fixing of Linear Delineator System (LDS) panels made of Micro Prismatic Retro Reflective sheeting type XI duly laminated on thin aluminium foil to a unique corrugated shape to provide Retro Reflection across wide range of observations and external angles. Eatch LDS panel should be of nominal length of 33 inch and each ridge shall be approximately 0.34 inch high. Each LDS panel is to be firmly fixed on existing concrete/brick work with 16 Nos fastner/ screw . SOR Ch-26 SI No.-9 6 Flexible Median Markers (FMM) should be used for improving median visibility during dark hour. Use of Median Marker provides safety against collision happening with medians during night time or servere weather. Flexible Median Markers shall be provided with fluorescent yellow colour retro-reflective sheeting Type XI as per IRC:67. Flexible Median Marker shall be of tough, high impact resistant, injection-molded, thermoplastic body with property of flexibility to prvide high durability and U Shape structure having rebound/bounce back property, the sheeting shall be of Type XI conforming to IRC:67, and it should be on both the faces whereby providing maximum reflectivity at I, anger distances with adequate durability. The logo of the manufacturer shall be embossed on either side of the body during the injection molding process. FMM shall be fixed by a combination bf epoxy adhesive and grouting/drilling on concrete medians or properly constructed solid medians Height. The marker height shall be a minimum of 180 mm, width 120 mm & Body thickness 6.5 mm. the shanks shall not be less than 20mm and depth shall not be less than 30 mm Reflective Area. Shall not bes less than 90 cm square proof of the same Report shall be uploaded which quoting tender. The body of FMM shall bounce back to its original position of after 750 number of hits using pendulum of 1.8 kg conforming 40 ASTM D256 adhesion between the body and outer casing body of FMM shall with stand 50 kg Tensile loads conforming to ASTM D638 method. The shall include all materials, labour T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge. as per SOR Ch-26 SI No.-6 7 Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67 upto date made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with PCC M-25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67 upto date. Legends , letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 . Proof of the same in form of government report shall be uploaded while quoting tender. As per SOR ch-26 SI no.-18Cautionary Signs / Mandatory/Regulatory Sign Hazard Marker (30 x 90cm Left/Riight) Object Hazard 8 No Parking (60cm circular) 9 No Standing No stopping (60cm circular) 10 Maximum speed limit(60 cm Circular with diffinitation plate ( 20 x 60)) 11 2.40 M Span over head Cantilever Structure with 150 dia MS one vertical post (Double side Retro reflective sign board)Supply, fixing & erection of built up Cantilever Structure 2.40 m span comprising of one vertical posts of 7.30 M height made up of 150 mm NB medium class MS pipe and 4.85mm thick as vertical member welded with 10 mm MS plate at top & 10 mm MS plate at bottom fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant and The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67 upto date . Legends , letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 . The work includes construction of RCCFoundation of size 0.60x0.60x1.20 m of required depth as per site condition for built up structure including Earth work in excavation 100 mm thick Lean Concrete in 1:3:6 cement coarse sand and 40 mm gauge stone ballast RCC M25 including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering. The lateral vertical clearances and complete. Installation work shall be as per relevant clauses of MoRT&H specification section 800 and IRC 67 upto date complete in all respect The Rates shall include cost of design fabrication, supply, transportation, Local shifting Erection of Signage structure using crane, inclusive of all T&P machine, material and labour required for proper completion of work as per direction of Engineer-in-charge. (Exclusive cost of G.S.T) as per SOR Ch-26 SI No.-29 12 Supply, fixing & eraction of built up Overhead Structure of 12M-15M span comprising of two vertical posts of 6.00 M height made up of 300 mm NB heavy class MS pipe as vertical member welded with 10 mm MS plate at top & 12 mm M S plate at bottom. The horizontal Truss shall comprise of 50 mm dia heavy class M.S. pipe and 40 mm dia heavy M S pipe as bracing & 10 mm MS plate at bottom for fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant. The work includes construction of RCCFoundation of size 0.90x0.90x1.50 mof required depth as per site condition for built up structure including Earth work in excavation 100 mm thick Lean Concrete in 1:3:6 (cement coarse sand and 40 mm gauge stone ballast) and Grade of Concrete RCC M-25 including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering. The lateral vertical clearances and complete. Installation work shall be as per relevant clauses of MORT&H specification section 800 andIRC 67 upto date complete in all respect. The Rates shall include cost of design, fabrication, supply, transportations, Local shifting Erection of Signage structure using crane, inclusive of all T&P machine, material and labour required for proper completion of work as per direction of Engineer-in-charge. as per SOR Ch-26 SI No.-7