| 1 | Labour only for repairing and attending the complaint of Split AC/WindowAC/ Water cooler/Refrigerato/Deep freezer by highly skilled tradesman and carryout minor repair and making functional complete all as specified and directed. |
| 2 | Taking out & removing old existing plywood of any description and in any position and supplying and fixing new plywood 4mm thick, grade BWR, type BB, 3 ply, cut to size made to shape and fixed in position with nails as to make the window of desert cooler/window AC etc air tight complete all as specified and directed. |
| 3 | M&L for cross arms, bracing supports clamps and back plate fabricated from structural steel section including bolts, nuts, washers and welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint including dismantling old cross arms, bracing supports clamps completeall as specified and directed. |
| 4 | Dismantling and taking out exiting defective Copper tubing off Size of any description & in any position and supplying and fixing new copper tubing special annealed pressure copper purity min 99.9% and making flairing at both ends for connections including Brass nutof any size as required and inclinsulating material etc and testing complete all as specified and directed. |
| 5 | Taking out window type AC 1.5/2 ton and reinstallation including window opening cutting and provision of packing material as per site requirement including closing of old opening and making new opening all as specified and directed. |
| 6 | S&F in replacement compressor of window type air conditioner 1.5/2 Ton capacity ofexisting make and providing new sealed compressorunit of same size and make, connecting up suction and discharge pipe with gas welding, pressure testing, leakage rectification vaccumising and includinginitialcharging of Refrigerant gas R-22, compressor oil, testing commissioning including taking down old U/s compressor, complete all as specified and directed. |
| 7 | Description all as per item No 6.00 above but in replacement with new sealed compressor unit forsplit type AC of 1.5/2 ton capacity complete all as specified and directed. |
| 8 | S&F in replacement of thermostat switch for any capacity window/split type air conditioner complete all as specified and directed. |
| 9 | S&F in replacement of PVC air filter suitable for 1.5/2 ton window type air conditioner of any make complete all as specified and directed. |
| 10 | S&F in replacement of over load protector for any type AC 1.5/2 Ton capacity complete all as specified and directed. |
| 11 | S&F in replacement of condenser fanblade suitable for 1.5/2 ton window type air conditioner of any make complete all as specified and directed. |
| 12 | S&F in replacement of condenser fan motor 1/5 HP 230 volt AC Cooper winding single phase double shaft suitable for 1.5/ 2.0 ton window type AC complete all as specified and directed |
| 13 | S&F in replacement of condenser fan motor copper winding single phase 230 volt AC suitable for 1.5/2 Ton capacity split AC of existing make complete all as specified and directed |
| 14 | S&F in replacement offront grill suitable for window type air conditioner capacity 1.5 Ton as per existing complete all as specified and directed. |
| 15 | S&F in replacement Single pole and neutral, Sheet Metal enclosure with Socket plug Top and MCBs. and two pin and earth plug and socket with one single pole MCB 25 Ampscompelte all as specified and directed. |
| 16 | M&L for taking down window/split type air conditioner of 1/1.5/2 Ton capacity / make / size at site,opening top and side covers disconnecting all electrical controls components and cleaning the complete units with electric blower and sprayingclean water, descaling withcoil shine solution in both side of cooling coil and condenser, brush cleaning with nylon brush and washing with clean water, refixing the covers and making electrical connection of all the controls and components, installing back the same on site testing, commissioning incl black painting to bottom complete all as specified and directed. |
| 17 | M&L forGas rechargingin window/split type AC 1.5 Ton/2 Ton capacity of any make including pressure testing, leakage rectification, vaccumising and testing commissioning complete all as specified and directed. |
| 18 | S&F in replacement of PCB board suitable for 1.5/2 Ton window/split AC/DC including display & remote of existing make complete all as specified and directed. |
| 19 | Taking out Split type AC 1.5/2 ton and relocation/ reinstallation as per site requirement including all connecting accessories i.e back plate nuts boltscomplete all as specfied and directed at site. Note (Copper piping will be measured and paid separately) |
| 20 | S&F in replacement Outdoor condensing unit of split type AC of capacity 1.5/2 TR capacity& fixing new condensing unit with Anti Corrosive blue fins, complete with condensing coil, coil frame, wiring kit starting and running capacitor, relay condensing motor, with blade completeall as specified and directed make LLYOD and its equivalent. |
| 21 | S&F in replacement of running capacitor 36 MFD complete all as specified and directed. |
| 22 | S&F in replacement of starting capacitor 45 MFD complete all as specified and directed. |
| 23 | S&F in replacement of starting capacitor 45 MFD complete all as specified and directed. |
| 24 | S&F in replacement of electric wiring kit suitable for 1.5/2 Ton window/splitAC of any make complete all as specified and directed. |
| 25 | S&F in replacement indoor unit of split type AC\"s 1.5 ton with suction, discharge, water drainage pipe line, wall mounting brackets etc,complete all as specified and directed.Make LLYOD & its equivalent |
| 26 | S&F in replacement voltage Stabilizer metal body, heavy duty of capacity5 KVA for automatic operation, single phase , natuarally air cooled , indoor type metal body ,design for input variation between 170 volt to 270 volts and with output voltage stabilizer at 230 Volts with accuracy of (=/-) 2.5 % and connecting up all as per manufacture\"s instruction and directed. |
| 27 | S&F in replacement of revolving motor kit for louvers (for AC grill) in window type AC 1.5 Ton of any make and model complete all as specified and directed. |
| 28 | S&F in replacement new remote assembly for split/windowtype AC 1.5/2 ton ofany make& existing modelcomplete all as specified and directed. . |
| 29 | Taking down old sealed unit of refrigerator 165-185 ltrs capacity of any make and providingnew sealed compressor ofsame size, make and capacity connecting up suction and discharge pipe with gas welding, pressure testing, flushing the complete system, leakage rectification vaccumising and including initial charging of refrigerant gas, testing commissioning complete all as specified and directed. |
| 30 | Description all as per item No 29.00 above but 190 to 230 ltrs capacity complete all as specified and directed. |
| 31 | Description all as per item No 29.00 above but 240 to 330 ltrs capacity complete all as specified and directed. |
| 32 | S&F in replacement of freezer with cooling coil for 165 to 220 ltrs capacity refrigerator of existing make complete all as specified and directed. |
| 33 | Description all as per item No 32.00 above but for 310 liters capacity refrigerators complete all as specified and directed. |
| 34 | S&F in replacement oflamp 15 watt screw / Pin type suitable for any make and capacity refrigerator complete all as specified and directed. |
| 35 | S&F in replacement of Over loding relay suitable for low/high speed refrigerator compressor of any capacity complete all as specified and directed. |
| 36 | S&F in replacement ofthermostat suitable for any capacity refrigerator complete all as specified and directed. |
| 37 | M&L for Charging with refrigerantgas 134a after vacuuming /pressure testing and leakage testing including flushing the system in the refrigerator of any make of165 to 310 ltrs capacity complete.all as specified and directed. |
| 38 | S&F in replacement of fan moter of Capacity 165 to 330 ltr suitable for refrigerator of any make and capacitycomplete.All as specified and directed |
| 39 | S&F in replacement of PCB board suitable for refrigerator of existing make and capacity 165 ltr to 300ltr complete all as specified and directed. |
| 40 | S&F in replacement Vegetable tray suitable for refrigerator of capacity upto 286/300 ltr complete all as specified and as directed by Engineer-in-charge. |
| 41 | S&F in replacement Ice chamber (freezer box) including freezer cover suitable for refrigerator of capacity 165 ltr to 320 Ltrs complete all as specified and as directed by Engineer-in-charge. |
| 42 | SM&L for taking down sealed unit of deep freezer upto 320 ltrs capacity of any make and providing in replacement new sealed compressorof same size, make and capacity connecting up suction and discharge pipe with gas welding, pressure testing, flushing the complete system, leakage rectification vaccumising and including initial charging of refrigerant gas, testing commissioning complete all as specified and directed. |
| 43 | Description all as per Ser item No 42.00 above but 500 ltrs capacity deep freezer complete all as specified and directed. |
| 44 | S&F in replacement of Over loding relay suitable for deep freezer upto 500 Ltrs capacity complete all as specified and directed. |
| 45 | S&F Deep Freezer body with copper tubing and compressor suitable for 500 ltr deep fridger all as specified and directed by Engr-In-Charge. |
| 46 | S&F in replacement of thermostat suitable for deep freezer upto 500 Ltrscapacity complete all as specified and directed. |
| 47 | S&F in replacement of fan motorsuitable for deep freezer any type complete all as specified and directed. |
| 48 | M&L for taking downold unserviceable compressor of water cooler of capacity 40/80 litres any make/size and providing new sealed compressor and connecting up suction and discharge copper pipe with gas welding, pressure testing of leakage, leakage rectification, vacumising and including initial charging of refrigerant gas R 22, testing, commissioning complete all as specified and directed. |
| 49 | Description all as per item No 48.00 but water cooler of capacity 60/120 litres complete all as specified and directed |
| 50 | Description all as per item No 48.00 above but water cooler of capacity 150 litres complete all as specified and directed. |
| 51 | S&F in replacement of starting/running capacitor 10 to 80 mfd suitable for water cooler of any capacitycomplete all as specified and directed |
| 52 | S&F in replacement of thermostat switch for water cooler any cap complete all as specified and directed. |
| 53 | S&F in replacement of condenser fan motor 1/ 3.5 HP 250 Volts AC Single phase suitable for water cooler complete all as specified and directed. |
| 54 | S&F in replacement of starting relay kit suitable for any make & capacity water cooler complete all as specified and directed. |
| 55 | S&F in replacement of condenser fan blade for fan motor suitable for water cooler of any make/capacity complete all as specified and directed. |
| 56 | M&L for Gas charging in water cooler of any capacity and make including pressure testing, leakage rectification, vaccumising and testing commissioning complete all as specified and directed. |
| 57 | S&F in replacement of electric wiring kit suitable for water cooler of any make and capacity complete all as specified and directed. |
| 58 | S&F in replacement of PVC float valve assembly suitable for water cooler of any size/capacity non metallic body complete all as specified and directed. |
| 59 | S&F in replacement PVC waste pipe 32mm, dia with complete fittings suitable for water cooler of any make and capacity complete all as specified and directed. |
| 60 | S&F in replacement water tap in steel body suitable for any capacity of water cooler with fitting arrangement such as washer and suitable size nipple all as specified and directed. |
| 61 | S&F in replacement ofdesert cooler submersible pumpsingle phase complete all as specified and directed. |
| 62 | S&F in replacement ofdesert cooler fan motor duly wounded Copper suitable for operation on 230 V single AC supply 3 speed 1400 RPM complete all as specified and directed. |
| 63 | S&F in replacement of selector switch for controlled speed complete all as specified and directed. |
| 64 | S&F in replacement of wood wool pad superior quality for desert cooler of capacity 4000 Cum/hr 5000 Cum/hr having minimum weight 450 gms complete all as specified and directed. |
| 65 | S&F in replacement of capacitor 4 mfd suitable for desert cooler complete all as specified and directed. |
| 66 | S&F in replacement ofPVC pipe 15 mm dia of superior quality complete all as specified and directed. |
| 67 | Dismantling , cutting and taking out old winding of desert cooler fan motor of any make and M&L for rewinding of the same with super enameled copper winding wire and providing shallac varnish, testing commissioning complete all as specified and directed. |
| 68 | S&F in replacement of PVC water distributor 3 way for desert cooler of superior quality complete all as specified and directed. |
| 69 | S&F in replacement of high grade metal fan blade suitable for 18/20 inch sweep desert cooler motor complete all as specified and directed. |
| 70 | S&F in replacement of desert cooler body (overall mimimum size 26 inch x26 inchx39 inch) made out of 22 gauge galvanized sheet,depth of water tank shall not be less than 9/10 inch,including front adjustable grill both side i.e. horizontally and vertically and suitable three side slotted shutter Including necesry fabrication, belding wks complete all as specified and directed. |
| 71 | S&F in replacementadjustable front grill made of GI sheet ,having with air direction control system with knob, P/T switch, indicator lamp,complete suitable for 20\"/24\" desert cooler. complete all as specified and directed. |
| 72 | S&F in replacement of indicating lamp, 230 volts complete all as specified and directed. |
| 73 | S&F in replacement Plug top 16A, 3 pin, 230 AC, ISI markedcomplete all as specified and directed. |
| 74 | S&F in replacement of PVC cable for lead wire pvc seathed 3 core size 40/0.0076 of multistranded copper conductors for water coolers/ AC, complete all as specified directed Make Plaza/Havells/Finolex. |
| 75 | S&F in replacement of plug top 5 Amps 3 pin, ISI marked complete all as specified and directed. |
| 76 | Dismantling carefully ceiling fans (any make) of 1200/1400 mm sweep cuting & removing old copper/Aluminium winding wire andrewinding the same with new super enameled copper wire of suitable size/Gauge and weight not less than 325 gmincluding providing insulation by varnishing, oiling and greasing, replacing bearing and gun metal shaft required and reassembling back includung testing complete all as specified and directed.(i) cost of bearing shall be measured in this item and nothing will be paid be extra on this account. (ii) work space if required will be provided to the contractor for carring out necessary rewinding/repair within AGE E/M store yard. (iii) If winding fan found unserviceable with in six month of rewinding contractor will repairs the same without any cost. iv) Cost of machining work in body of ceiling fan by taking out warn out bearing boring hole to accomodate ball bearing is included in this item and nothing shall be paid extra on this account |
| 77 | Supply & Fixing in replacement capacitor 2.5 mfd to 3.15 mfddry typewith PVC clampmakeof capacity Epcos/Unistar/Usha. |
| 78 | S&Fin replacement electronic ceiling fan regulator stepped typeheavy duty suitable to work on 230 volts complete all as specified and directed. |
| 79 | Dismantling carefully Exhaust Fan 300/450 sqmm (any make) of cuting & removing old copper/Aluminium winding wire andrewinding the same with new super enameled copper wire of suitable size/Gauge including providing insulation by varnishing, oiling and greasing, replacing bearing and gun metal shaft required and reassembling back includung testing complete all as specified and directed.(i) cost of bearing shall be measured in this item and nothing will be paid be extra on this account.(ii) work space if required will be provided to the contractor for carring out necessary rewinding/repair within AGE E/M store yard. (iii) If winding fan found unserviceable with in six month of rewinding contractor will repairs the same without any cost.(iv) Cost of machining work in body of Exhaust fan by taking out warn out bearing boring hole to accomodate ball bearing is included in this item and nothing shall be paid extra on this account. |
| 80 | S&F in replacement of shaft for ceiling fan of any sweep and fixing in position for smooth functioning of ceiling fancomplete all as specified and directed. |
| 81 | Replacement PVC canopy for ceiling fans of any sweep and make and fixing in position complete all as specified and directed |
| 82 | Supply & Fixing in replacementof blades of ceiling fan of any sweep & make complete all as specified and directed.. |
| 83 | Supply & Fixing in replacement of capacitor 4 to 6 mfd for exhaust fan complete all as specified and directed. Make: USHA, Shriram, Unistar/Epcos |
| 84 | S&F in replacement Wall mounting Fan 400 mm sweep, 230volts, fixed on wall with suitable size nut, bolts and washerscomplete all as specified and directed. |
| 85 | S&Fin replacement PVC air fresh air Fan 200/250 mm sweep, 230volts, fixed on wall with suitable size nut, bolts and washers and connection complete all as specified & directed. Note; Make a hole as per site requirement rate include in this price Make Orient and its equivalent and verified by local area manager |
| 86 | S&F in replacementMS down rod of 15mm dia suitable for fan in any length including threading , drilling holes complete all as specified and directed. |
| 87 | Supply & Fixing in replacement blades of exhaust fan 380/300/450 mm of any make complete all as specified and directed. |
| 88 | S&F in replacement of hanging hook with washer, nut bolt with rubber packing complete all as specified & directed by Engr-In-Charge.. |
| 89 | Supply & Fixng in replacement of inner and outer body of Ceiling fan require size as per site and directed by Engr-In-Charge |
| 90 | S&Fin replacement Fan Stator with copper winding andwith necessary item such as MS down Rod suitable for 1200/1400 sq mm sweep fan require size as per site and directed by Engr-In-Charge |
| 91 | S&Fin replacement of Ceiling Fan 1200/1400 mm sweep fan body upper and down as per site requirement and directed by Engr-In-Charge. |
| 92 | S&Fin replacement rotor for suitable of 1200/1400 MM sweep ceiling fan all as specified and directed by Engr-In-Charge. |
| 93 | S&Fin replacement PCB with remote for BLDC ceiling fan 26 watt make havells all as specified and directed by Engr-In-Charge. |
| 94 | S &F in replacement of Exhaust Fan Louvers with cage size 300/450 mm all as specified and directed by Engr -In-Charge |
| 95 | Dismantling carefully Wall Fan/ Industrial Fan Metal Body/Pedstal Fan of any size & cutting down & removing old copper winding wire and M&L forrewinding the same with new super enameled copper wire of suitable sizeincluding providing insulation by varnishing, oiling and greasing & Refixing the same on site complete all as specified and directed.(Note: If winding fan motor found U/S in six month contractor repair the same with out any cost.) |