| 1 | Cleaning of RCC Over Head Reservoir of capacity 50000 Glns as described below :i) Before starting the cleaning of Over Head Reservoir, distribution line from OH tank is to be disconnected and plugged with suitable fitting. After cleaning, pluggedlineshould be washed out and connected to the distribution pipe line as per existing position. Cost of required earth work and excavation at places is deemed to be included in item rate quoted by the contractor.ii)The inner surface of the walls and ceiling of the tank shall be cleaned with high pressure jet pump after emptying the water in the tank. iii)After thorough cleaning of the tank, thecleaning water and sludge is to be removed by using pump and the sludge has to be disposed off at a place as directed.iv)After removing the sludge from tank, the tank shall be first cleaned thoroughly by using high pressure water pump and againthe floor and inner surfaces of the tank shall be cleaned by using a industrial vaccum cleaner and the tank shall be made fully dirt free.v)After making the tank dirt free, the inner surfaces of walls and ceiling of the tank shall be treated with anti bacterial agents. (vi) After the treatment as mentioned at (iv) above, the inner surfaces of walls and ceiling shall be treated with UV Radiator. |
| 2 | NOTE :(i) The unit rate quoted deemed to be including draining of water with mechanical equipment and working in water and mud etc.(ii)The unit rate quoted deemed to be inclusive of all safety precautions which shall be taken while working on RCC over head tank/underground sump and contractor or his Engineer shall be available during execution of the job.(iii)Lighting arrangements if required shall be provided by the contractor temporarily at his own arrangements and the rate quoted is deemed to be inclusive of this and electricity / diesel shall not be provided by the department. (iv)Contractor will not be allowed more than one day to do the work inside each OH tank/UG sump to precvent interruption of water supply to the users.Over head tank of 50000 Gallon capacity at a) Hill top 9 MT area/Taramati Md Accn Pump house/Outside MKD near Swimming pool at Arty Centre b) 64 ORs Map qtr, Towli Chowki Qtrs/KVS - II, and Map Md Accn (near Signal Centre Pump House) at Asif Nagar and c) Old Md Lines (Near 19 Rajput Md Accn) at MH/MD Lines |
| 3 | All as per Item No:01 here-in-before but Over head tank of 25000 Gallon capacity at following location:-a) Near cook house 9 MT area/16 Dogra Regt 7th mile area at Arty Centreb) butchery, 40 JCOs patter bldg at Asif Nagar c) MH Golconda (near SHO office) |
| 4 | All as per Item No:01 here-in-before but Over head tank of 250000 Gallon capacity near CHQ main office area at Arty Centre. |
| 5 | All as per Item No:01 here-in-before but Over Head Tank capacity of 150000 Gallon at New 40 JCO\" Pump House at Asif Nagar. |
| 6 | All as per Item No:01 here-in-before but Over head tank of 100000 Gallon capacity at following location:-a) 12 Jakliunit Areaat Asif Nagarb) Offrs Md Accn (Near RSI) at MH/MD area andc) Signal Centre Pump House at MH/MD area |
| 7 | All as per Item No:01 here-in-before but Over head tank of 75000 Gallon capacity at Dogra Area at Asif Nagar. |
| 8 | All as per Item No:01here-in-before but Over head tank of 25000 Ltrs capacity at ASC Supply Depot Unit Area. |
| 9 | All as per Item No:01 here-in-before but Over head tank of 10000 Ltrs capacity at 613 Unit Area. |
| 10 | All as per Item No:01 here-in-before butcleaning of RCC under ground sump / semi under ground sump of following :-Semi under ground sump of capacity 50000 Gallon.a) at Hanuman mandir PH and b) Outside MKD near Swimming pool PH at Arty Centre,c) 64 ORs Map qtrs Area and Signal Centre Pump House and MAP Md Accn (near Signal Centre Pump House) at MH/MD Lines |
| 11 | All as per Item No:01 here-in-before but Semi under ground sump of capacity 30000 Gallonat Inside MKD PH/taramati Md Accn PH & Near Indoor Stadium 3 Trg Arty Centre. |
| 12 | All as per Item No:01 here-in-before but Semi under ground sump of capacity 15000 Gallonat 16 Dogra Regt PH & Pantathalom Stadium Outside MKD Arty Centre |
| 13 | All as per Item No:01 here-in-before but Semi under ground sump of capacity 10000 Gallonat :-a)Firing range PH/Inside MKD near Officers Md accn PH & IB line JCOs mess PH at Arty Centreandb) 28 JCO\"s pump house,40 JCOS pattar bldg at Asif Nagar |
| 14 | All as per Item No:01 here-in-before but Semi under ground sump of capacity 250000 Gallon at IB line PH at Arty Centre. |
| 15 | All as per Item No:01 here-in-before but Semi under ground sump of capacity 300000 Gallon infront of 354 Fd Hosp area at Asif Nagar. |
| 16 | Taking down water level indicator unit from Over head reservoir/Semi Under ground sump, supply and fix new water level indicatorwith complete accessories such as copper ball, necessary pully, nylon rope, steel patti duly painted white with marking at every 10cm interval, letter writing of size 15mm width and 100mm long with signal red radium paint and painting of indicator with illumination postal red paint and errected at the height of 3 meter from ground level with necessary angle iron, nut and bolts complete all as specified and as directed. |
| 17 | Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw including taking out old unserviceable one complete all as specified and as directed. |
| 18 | S&F Air termination, single pointed aluminium rod 12mm dia and 300mm longincluding taking out old unsserviceable one complete all as specified and as directed. |
| 19 | Supply, laying, connecitng, testing and commissioning PVC insulated, PVC sheathed armoured, heavy duty electric power cable with multi stranded copper conductor, 1100 volts grade, of cross-sectional area 2.5 Sqmm 3 - core for aviation obstruction light of OH reservior upto 25m height including cutting to required lengths and connecting with necessary lugs and glands at both ends and taking out the existing burnt/ unserviceable onefrom panel/ starter complete all as specified and as directed. |
| 20 | Supply and replace MCB DB Double Door 4-Way SPN 240 Volts and removig unserviceable materials out of site including connecting complete all as specified and as directed. |
| 21 | Supply and replace existing unserviceble MCB SPN 240V, 10 KA \"C\" curve 6 to 30 Amps complete with connection testing and commissioning complete all as specified and directed. |
| 22 | Supply and replace aviation obstruction lightaviation yellow painted die cast aluminium alloy housing built inheat resistant clear thick glass and accessories LED aviation obstruction light suitable to operate on 230 volts single phase AC supply complete on OH reservior complete all as specified and as directed. |
| 23 | Disconnecting existing water level indicator, taking out defectiveMS wire rope from overhead tanks of any head, pulley, ball and replacing with new MS wire rope, ball of dia 300mm with provision for fixing wire, greasing and refixingboth the pullies on another side as directed including marking the level on the indicator complete all as specified and as directed. |
| 24 | S & Ffoot valve of 50MM dia size for CI pipeline as that of existing model complete with necessary nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed. |
| 25 | S & Ffoot valve of 80MM dia size for CI pipeline as that of existing model complete with necessary nuts,bolts and gasket as per site requirement fixing in position completeincluding taking out existing all as specified and as directed. |
| 26 | S & Ffoot valve of 100MM dia size for CI pipeline as that of existing model complete with necessary nuts,bolts and gasket as per site requirement fixing in position completeincluding taking out existing all as specified and as directed. |
| 27 | S & Ffoot valve of 150MM dia size for CI pipeline as that of existing model complete with necessary nuts,bolts and gasket as per site requirement fixing in position completeincluding taking out existing all as specified and as directed. |
| 28 | S & FAir releasevalve of 50MM dia size to the exgisting CI/DI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed. |
| 29 | S & FNRVof 80MM dia size to the exgisting CI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed. |
| 30 | S & FNRVof 100MM dia size to the exgisting CI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed. |
| 31 | S & FNRVof 150MM dia size to the exgisting CI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed. |
| 32 | S & FNRVof 200MM dia size to the exgisting CI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed. |
| 33 | Taking out the unserviceable cast iron sluice valve for size 80 mm bore, supplyand fixing of new CI sluice valves PN 1.6 confirming to ISI with flanged ends, both end drilling with SS spindle, round wheel including jointing materials, nuts, bolts and gasket complete all as specified and directed. |
| 34 | Taking out the unserviceable cast iron sluice valve for size 100 mm bore, supplyand fixing of new CI sluice valves PN 1.6 confirming to ISI with flanged ends, both end drilling with SS spindle, round wheel including jointing materials, nuts, bolts and gasket complete all as specified and directed. |
| 35 | Taking out the unserviceable cast iron sluice valve for size 150 mm bore, supplyand fixing of new CI sluice valves PN 1.6 confirming to ISI with flanged ends, both end drilling with SS spindle, round wheel including jointing materials, nuts, bolts and gasket complete all as specified and directed. |
| 36 | Taking out the unserviceable cast iron sluice valve for size 200 mm bore, supplyand fixing of new CI sluice valves PN 1.6 confirming to ISI with flanged ends, both end drilling with SS spindle, round wheel including jointing materials, nuts, bolts and gasket complete all as specified and directed. |
| 37 | Taking out the unserviceable cast iron sluice valve for size 250 mm bore, supplyand fixing of new CI sluice valves PN 1.6 confirming to ISI with flanged ends, both end drilling with SS spindle, round wheel including jointing materials, nuts, bolts and gasket complete all as specified and directed. |
| 38 | Supply and fix in repair plastic jar for chlorine dosingcomplete all as specified and directed. |
| 39 | Supply and fix in repair chlorine dosing pump system6 BPH at 4 Bar complete all as specified and directed. |
| 40 | Supply and lay galvanized steel water tubing medium grade of50 mm bore complete with all fittings such asbends elbows, tees, short pieces, connectors, back nuts, diminishingpieces, caps and pigs, unions including taking up or down existing steel tubing with fittings all as specified and directed. |
| 41 | Supply and lay galvanized steel water tubing medium grade of80 mm bore complete with all fittings such asbends elbows, tees, short pieces, connectors, back nuts, diminishingpieces, caps and pigs, unions including taking up or down existing steel tubing with fittings all as specified and directed. |
| 42 | M&L for 100 mm dia Ductile iron pipeswith spigot and socket end includingtyton joints, Class K-9 laid in trenches alongwith taking taking up or down GI/CI/DI water mains 100mm dia (including all fittings) with spigot and socket ends and lead joints, burning out points and recovering lead complete all as specified and directed. |
| 43 | All as per item No. 42 above but 150mm dia |
| 44 | All as per item No. 42 above but 200mm dia |
| 45 | Material & LabourDI fittings for spigot/flanged end pipes such as bends any type (radius and angle) tapers any type (straight, bend increasing or decreasing double socket flanged etc), Tee pieces, single branch, \"Y\" junction, double branch cross (all socket or socket and spigot or flanged, Collars,caps and plug etc up to 250mm bore complete all as specified and directed. |
| 46 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts wells, cesspits, manholes, pier holes etc not exc 10sqm on plan and getting out in hard/dense soil complete all specified and directed. |
| 47 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc.,25cm thick each layer in hard/dense soils all specified and as directed. |
| 48 | Removing excavated materials to a distance not exc 50 M and depositing where directedat a level not exc. 1.5 M above the starting point all as directed |
| 49 | Supply and fix in repair steel water tubing, galvanised, heavy duty, 50 mm bore, column pipe, both ends threaded, incuding taking down existing pipe all as specified and directed. |
| 50 | Supply and fix in repair steel water tubing, galvanised, heavy duty, 40 mm bore, column pipe, both ends threaded, including taking down existing pipe all as specified and directed. |
| 51 | Supply and fix High density polyethylene pipes (HDPE) of pressure rating 16 kgf/cm2 of 50mm bore both end threaded alongwith fittings all as specified and directed. |
| 52 | Supply and fix High density polyethylene pipes (HDPE) of pressure rating 16 kgf/cm2 of 75mm bore both end threaded alongwith fittings all as specified and directed. |
| 53 | Supply, laying and testing 3 core 16 Sqmm, PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694,fixed to Centrifugal motor pump set to fully automatic starter, complete, including taking out old unserviceable cable of any description all as specified and directed. |
| 54 | Redevelopment of tube wellof maximumm depth of100 mtr by means of pumping by Air compressor of minimum pressure 10 Kg/cm2 (compressor to be arranged by contractor at his own cost), until sand free and clean water is obtainedcomplete all as specified and directed. |
| 55 | Supply, laying and testing PVC insulated and sheathed flat 3 core 6 Sqmm, copper stranded conductor water proof submersible cable fixed to submersible monoblock pump set to starter, complete, including taking out old unserviceable cable of any description all as specified and directed. |
| 56 | Supply, laying and testing PVC insulated and sheathed flat 3 core 10 Sqmm, copper stranded conductor water proof submersible cable fixed to submersible monoblock pump set to starter, complete, including taking out old unserviceable cable of any description all as specified and directed. |
| 57 | M&L Attending emergency breakdown of water supply installations where directed, Lifting up defective submersible pumpset of cap 5HP, 3 phase, 415 volts, any stage and deep, column pipes (any number) from bore well, setting aside and stacking column pipes for reuse, transportating unserviceablepumpset from borewell to workshop Opening of the defective motor & pump in MES store yard/ workshop, cleaning the covers and parts as applicable in presence of Engineer in Charge to ascertain the quantam of defects and repairs involved and assembling the motor & pump after carrying out repair works to make smooth functioning, applying spray painting to the repaired motor& pump externally with two coats of synthetic enamle paint of shade as directed by the Engineer in Charge transporting repaired pumpset from workshop to bore well site after completion of repair work, lowering of submersible pumpset with column pipes in the bore well as existing with new nut bolt and washer including rubber gasket 3 mm thick, including electrical supplyconnections as per existing for smooth functioning of pump motors complete all as specified anddirected.Note: Repair work of submersible pump set will measured andpaid separately under respective items of this schedule. |
| 58 | All as per item No. 57 above here in before but for submersible pumpset and motor of capacity 7.5 HP. |
| 59 | All as per item No. 57 above here in before but for submersible pumpset and motor of capacity 10 HP.Note for Sl. Item Nos. 57 to 59 :-(i) Any spare parts required to replaced during repair, servicing, overhauling of motor, pump set etc shall be measured and paid separately under respective items of this schedule as supply only.Labour element involved in replacement of material shall deemed to included in the rates quoted.(ii) Any minor repairs involved to make the motor, pump functional even if notified by the Engineer in Chargeshall be carried out by the contractor without any extra cost to the department.(iii) In case of rewinding of stator of motor shall be measured and paid separately under respective item of this schedule.(iv) Greasing/ oilingetc., of parts as required shall deemed to inclusive in the rate quoted. |
| 60 | Supply only the followingspares required against Sl. Item No. 57, where required for submersible pumpset of capacity 5 HP as per the model and make as specified and directed:- |
| 61 | Water lubricant seal suitable for motor. |
| 62 | Thrust bearingfor pumps |
| 63 | Bearing cover sleeve. |
| 64 | Thrust bearingfor motors |
| 65 | Impeller fibre type |
| 66 | Neck ring |
| 67 | Stainless steel key for impeller shaft |
| 68 | Stainless steel motor - pump shaft coupler |
| 69 | Body bush for pump |
| 70 | Stainless steel sleeve for pump shaft |
| 71 | Pump shaft gun metal of appropriate size |
| 72 | Thrust pad |
| 73 | Rubber bushes to motor shaft. |
| 74 | Thrust plate |
| 75 | Supply only the followingspares required against Sl. Item No. 58, where required for submersible pumpset of capacity 7.5 HP as per the model and make as specified and directed:- |
| 76 | Water lubricant seal suitable for motor. |
| 77 | Thrust bearingfor pumps |
| 78 | Bearing cover sleeve. |
| 79 | Thrust bearingfor motors |
| 80 | Impeller GM/PVC for 7.5HP submersible pump. |
| 81 | Neck ring |
| 82 | Stainless steel key for impeller shaft |
| 83 | Stainless steel motor - pump shaft coupler |
| 84 | Bodybushfor pump |
| 85 | Stainless steel sleeve for pump shaft |
| 86 | Pump shaft gun metal of appropriate size |
| 87 | Thrust pad |
| 88 | Rubber bushes to motor shaft. |
| 89 | Thrust plate |
| 90 | Supply only the followingspares required against Sl. Item No. 59, where required for submersible pumpset of capacity 10 HP as per the model and make as specified and directed:- |
| 91 | Water lubricant seal suitable for motor. |
| 92 | Thrust bearingfor pumps |
| 93 | Bearing cover sleeve. |
| 94 | Thrust bearingfor motors |
| 95 | Impeller GM/PVC for 10HP submersible pump. |
| 96 | Neck ring |
| 97 | Stainless steel key for impeller shaft |
| 98 | Stainless steel motor - pump shaft coupler |
| 99 | Bodybushfor pump |
| 100 | Stainless steel sleeve for pump shaft |
| 101 | Pump shaft gun metal of appropriate size |
| 102 | Thrust pad |
| 103 | Rubber bushes to motor shaft. |
| 104 | Thrust plate |
| 105 | M&L Rewinding of stator of submersible motor of capacity 10 HP with water proof insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed. |
| 106 | M&L Rewinding of stator of submersible motor of capacity 7.5 HP with water proof insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed. |
| 107 | M&L Rewinding of stator of submersible motor of capacity 5 HP with water proof insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed. |
| 108 | Servicing, overhauling of centrifugal pump, monoblock motor pump set of capacity 40 HP, 3 phase induction motor including carrying out maintenance check alongincluding transportation with following repairs:(a) Dismantling of monoblock motor pump set in presence of MES representative and display all the parts without damage any portion for inspection of Engineer in Charge to ascertain the serviceability of existing parts.(b) Heating, varnishing to stator, rotor with super quality varnish and drying out properly with external heat.(c) Cleaning, washing of bearing and use right quantity of ball bearing grease for bearing.(d) Checking play of impeller and bushing of pump.(e) Assembling of motor with old serviceable parts and replacement of unserviceable parts with new as ordered where necessary. (f) Installation of motor by making connections as per existing and testing on load. |
| 109 | All as per item No. 66 above but for centrifugal pump, monoblock motor pump set of capacity 30 HP. |
| 110 | All as per item No. 66 above but for centrifugal pump, monoblock motor pump set of capacity 15 HP. |
| 111 | All as per item No. 66 above but for centrifugal pump, monoblock motor pump set of capacity 10 HP.Note for Sl No 66 to 69:(i)Any spare parts required to replaced during servicing, overhauling of motor, pump set etc., shall be measured and paid for separately under respective items of this schedule as supply only.(ii) Labour element involved in replacementof spares shalldeemed to be included in quoted rates against this item.(iii)Any minor repairs involved to make the motor, pump functional even if notified by the Engineer in Chargeshall be carried out by the contractor without any extra cost to the department.(iv)In case of rewinding of stator of motor shall be measured and paid separately under respective items of this schedule.(v)Greasing/ oilingetc of parts as required shall deemed to inclusive of rate quoted by the tenderer. |
| 112 | M&L for Rewinding of stator ofinduction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 40 HP with bare copper winding of appropriate gauge, all as specified and directed. |
| 113 | M&L for Rewinding of stator ofinduction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 30 HP with bare copper winding of appropriate gauge, all as specified and directed. |
| 114 | M&L for Rewinding of stator ofinduction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 15 HP with bare copper winding of appropriate gauge, all as specified and directed. |
| 115 | M&L for Rewinding of stator ofinduction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 10 HP with bare copper winding of appropriate gauge, all as specified and directed. |
| 116 | Supply only the followingspare parts to incorporate against centrifugal monoblock motor pumpset of capacity 40 HP as required at site all as specified and directed. |
| 117 | Cast iron impeller |
| 118 | Ball/Thrust bearing suitable for different motor capacity as per existing. |
| 119 | Gland cup gun metal heavy duty. |
| 120 | Neck ring bush |
| 121 | Body bush |
| 122 | Thrust plate |
| 123 | Supply onlythe followingitems to incorporate against centrifugal monoblock motor pumpset of capacity varying from 30 HP as required at site all as specified and directed:- |
| 124 | Cast iron impeller |
| 125 | Ball/Thrust bearing suitable for different motor capacity as per existing. |
| 126 | Gland cup gun metal heavy duty. |
| 127 | Neck ring bush |
| 128 | Body bush |
| 129 | Thrust plate |
| 130 | Supply onlythe followingitems to incorporate against centrifugal monoblock motor pumpset of capacity varying from 15 HP as required at site all as specified and directed:- |
| 131 | Cast iron impeller |
| 132 | Ball/Thrust bearing suitable for different motor capacity as per existing. |
| 133 | Gland cup gun metal heavy duty. |
| 134 | Neck ring bush |
| 135 | Body bush |
| 136 | Thrust plate |
| 137 | Supply onlythe followingitems to incorporate against centrifugal monoblock motor pumpset of capacity varying from 10 HP as required at site all as specified and directed:- |
| 138 | Cast iron impeller |
| 139 | Ball/Thrust bearing suitable for different motor capacity as per existing. |
| 140 | Gland cup gun metal heavy duty. |
| 141 | Neck ring bush |
| 142 | Body bush |
| 143 | Thrust plate |