Tender For Electrical Work For 11 Kv Line Shifting In Construction Of Sdh Builidng At Shri Kolayat District Bikaner - 1 Supply & Erection Of M S Lattice Structure Of Height 12.8 Mtr Asper Discoms Approved Design & Details In Alignment, Includingpainting, bikaner-Rajasthan

Medical And Health Services has published Tender For Electrical Work For 11 Kv Line Shifting In Construction Of Sdh Builidng At Shri Kolayat District Bikaner - 1 Supply & Erection Of M S Lattice Structure Of Height 12.8 Mtr Asper Discoms Approved Design & Details In Alignment, Includingpainting. Submission Date for this Tender is 28-01-2025. Transmission Line Tenders in bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

47348296
Tender For Electrical Work For 11 Kv Line Shifting In Construction Of Sdh Builidng At Shri Kolayat District Bikaner - 1 Supply & Erection Of M S Lattice Structure Of Height 12.8 Mtr Asper Discoms Approved Design & Details In Alignment, Includingpainting
Open Tender
Indian
Rajasthan
Bikaner
28-01-2025

Tender Details

Tender For Electrical Work For 11 Kv Line Shifting In Construction Of Sdh Builidng At Shri Kolayat District Bikaner - 1 Supply & Erection of M S lattice structure of height 12.8 mtr asper DISCOMs approved design & details in alignment, includingpainting of tower of approved make two coat of red oxide paintand one coat of aluminium paint before installation and one coatof Aluminium paint after erection work completed as pertechnical specifications & drawing of DISCOM. (Excavation of pitPCC and CC foundation as per Discom specs. to be Paid Extra). Allas per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure Aattached with this BSR . 2 Supply and fixing of 11 kV pin insulator confirming to IS:731:1971with latest ammendment on existing bracket including allaccessories like MS forged hot dipped GI Pin confirming to IS2486(Part-I)/1993 & IS:2486 (Part-II)/1989 with latestamendment, and as per latest Discom specs. etc. as required. Allas per pre approved by Engineer in charge.For additionaltechnical parameters of product / work refer Annexure Aattached with this BSR 3 Supply and fixing of 11kV Disc insulator and Hot dippedgalvanized Hardware confirming to IS:731:1971 with latestammendment and as per latest Discom Specs. on existingbracket including all accessories etc. as required. All as per preapproved by Engineer in charge.For additional technicalparameters of product / work refer Annexure A attached withthis BSRB & S disc insulator 45 KN 4 B & S type hardware 45 KN 5 Supply and fixing M.S. channel (cut point) 100x50mm ISMC(9.5Kg. Per Mtr.) 2x1.8mtr. long with pilot patti 50x6mm thicknecessary nuts and bolts etc. as per technical specification &drawing of DISCOM. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work ,refer Annexure A attached with this BSR . 6 Providing & Laying XLPE insulated three core Armoured Aluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4-Grade electrolytic aluminium conductor confirming to IS: 8130 class-2of purity >99.6 %, Insulation Screening: Extruded SemiconductingCompound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have its own in house NABL accrediatedLaboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure A attached with this BSR .3 core 185.0 Sq.mm 7 Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through jointinclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .11 KV End Termination Kit Outdoor type3 core 120/150/185 Sq.mm 8 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 )with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .B class 100mm dia 9 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 14.6.1 6 SWG6 SWG G.I. ( Hot Dipped ) Wire 10 Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR100 sqmm of (6/4.72 mm+1/1.57 mm) (Dog) 11 Supply and erection of GI stay set confirming to pattern-1 ofBS:16/1974 and as per latest Discom Specifications completewith stay rod with anchor plate fitted with cast iron cross headand steel bow, in cement concrete 1:3:6 including excavation ofpit-re-filling etc complete as reqd. All as per pre approved byEngineer in charge.For additional technical parameters ofproduct / work refer Annexure A attached with this BSRStay set of dia 20mm, 2.4m long stay rod and anchor plate 380 x380 x 4.0 mm 12 Supplying and laying of Hot dip galvanized steel stay wire of 550-900 N/mm Quality confirming to IS-2141/2000 in all respectIncluding chemical composition (Heavily coated Hard quality) ofdia 7/3.15 mm(7/10 SWG) and as per latest Discom specs. etc. asrequired. All as per pre approved by Engineer in charge.Foradditional technical parameters of product / work referAnnexure A attached with this BSR 13 Supply and fixing of 11 / 33. KV Stay insulator as perIS:5300/1969 and as per Discoms standard specifications etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 110 x 75 x 22mm 11 KV Stay Insulator 14 Labour charges for Dismantling of existing electric poles (PCCpoles, MS channel, Lattic tower 12.6mtr. , 11 mtr. along with theACSR Conductors, 11KV/33KV/LT line etc. 11KV insulator LTinsulator guard wires, staywires and other electric items of thepole coming along the alignment of the road and removal and rerollingPCC pole, MS channel different sizes as well as handingover the same to DISCOM store including transportation fromsite to store and stacking of dismantling material in store and asper the direction of Engineer Incharge and clean the site good asper the requirement and submit the receipt from DISCOM/concering authority, including all complete works. 15 Earth work in excavation/ by mechanical means (Hydraulic Excavator) / Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: 16 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)

Key Value

Document Fees
INR 500 /-
EMD
INR 68600.0 /-
Tender Value
INR 34.30 Lakhs /-