}

Tender For Electrical Work For 33 Kv Line Shifting In Construction Of Sdh Builidng At Shri Kolayat District Bikaner - 1 Supply & Erection Of M S Lattice Structure Of Height 12.8 Mtr Asper Discoms Approved Design & Details In Alignment, Includingpainting, bikaner-Rajasthan

Medical And Health Services has published Tender For Electrical Work For 33 Kv Line Shifting In Construction Of Sdh Builidng At Shri Kolayat District Bikaner - 1 Supply & Erection Of M S Lattice Structure Of Height 12.8 Mtr Asper Discoms Approved Design & Details In Alignment, Includingpainting. Submission Date for this Tender is 28-01-2025. Transmission Line Tenders in bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

47348290
Tender For Electrical Work For 33 Kv Line Shifting In Construction Of Sdh Builidng At Shri Kolayat District Bikaner - 1 Supply & Erection Of M S Lattice Structure Of Height 12.8 Mtr Asper Discoms Approved Design & Details In Alignment, Includingpainting
Open Tender
NCB
Rajasthan
Bikaner
28-01-2025

Tender Details

tender for Electrical Work For 33 Kv Line Shifting In Construction Of Sdh Builidng At Shri Kolayat District Bikaner - 1 Supply & Erection of M S lattice structure of height 12.8 mtr asper DISCOMs approved design & details in alignment, includingpainting of tower of approved make two coat of red oxide paintand one coat of aluminium paint before installation and one coatof Aluminium paint after erection work completed as pertechnical specifications & drawing of DISCOM. (Excavation of pitPCC and CC foundation as per Discom specs. to be Paid Extra). Allas per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure Aattached with this BSR . 2 Supply and fixing of 33 kV pin insulator confirming to IS:731:1971with latest ammendment on existing bracket including allaccessories like MS forged hot dipped GI Pin confirming to IS2486(Part-I)/1993 & IS:2486 (Part-II)/1989 with latestamendment, and as per latest Discom specs. etc. as required. Allas per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure Aattached with this BSR . 3 Supply and fixing of 33kV Disc insulator and Hot dippedgalvanized Hardware confirming to IS:731:1971 with latestammendment and as per latest Discom Specs. on existingbracket including all accessories etc. as required.All as per preapproved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure A attachedwith this BSR .B & S disc insulator 120KN 4 B & S type hardware 120KN 5 Supply and erection of GI stay set confirming to pattern-1 ofBS:16/1974 and as per latest Discom Specifications completewith stay rod with anchor plate fitted with cast iron cross headand steel bow, in cement concrete 1:3:6 including excavation ofpit-re-filling etc complete as reqd. All as per pre approved byEngineer in charge.For additional technical parameters ofproduct / work refer Annexure A attached with this BSRStay set of dia 20mm, 2.4m long stay rod and anchor plate 380 x380 x 4.0 mm 6 Supplying and laying of Hot dip galvanized steel stay wire of 550-900 N/mm Quality confirming to IS-2141/2000 in all respectIncluding chemical composition (Heavily coated Hard quality) ofdia 7/3.15 mm(7/10 SWG) and as per latest Discom specs. etc. asrequired. All as per pre approved by Engineer in charge.Foradditional technical parameters of product / work referAnnexure A attached with this BSR 7 Supply and fixing of 11 / 33. KV Stay insulator as perIS:5300/1969 and as per Discoms standard specifications etc. asrequired. All as per pre approved by Engineer in charge.Foradditional technical parameters of product / work referAnnexure A attached with this BSR140 x 85 x 25mm 33 KV Stay Insulator 8 Supply and fixing M.S. channel (cut point) 100x50mm ISMC(9.5Kg. Per Mtr.) 2x1.8mtr. long with pilot patti 50x6mm thicknecessary nuts and bolts etc. as per technical specification &drawing of DISCOM. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work ,refer Annexure A attached with this BSR . 9 Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required includingbinding and twisting etc. complete in all respect as required. Allas per pre approved by Engineer in charge.For additionaltechnical parameters of product / work refer Annexure Aattached with this BSR100 sqmm of (6/4.72 mm+1/1.57 mm) (Dog)q 10 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, addles, making connection with GI/Cu purity purity >95% himble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .6 SWG G.I. ( Hot Dipped ) Wire 11 Supply and installation of spike of M.S. rod 20mm dia 3.0mtr.long for earthing of (tower/pole) drive into earth by mechanicalmeans sturcture connection the spike with cross arm top hamperPCC pole, lattics tower to earth etc. complete as per technicalspecification of DISCOM. 12 Supply and fixing of PG / T clamps on overhead lines/jumpers,made of aluminium alloy 4600 of IS 617-1994 (with latestamendment if any) with steel nut and bolts conforming to IS1363-1992 & IS 1367/1979-80 (with latest amendments if any)all ferrous metal parts intended for outdoor use except thosemade of stainless steel shall be protected by hotdip galvanisingin accordance with IS 2633-1986 complete in all respect asrequired. All as per pre approved by Engineer in charge.Foradditional technical parameters of product / work referAnnexure A attached with this BSRPG Clamp for Dog Conductor Type - A 13 Earth work in excavation/ by mechanical means (Hydraulic Excavator) / Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: 14 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 15 Labour charges for Dismantling of existing electric poles (PCCpoles, MS channel, Lattic tower 12.6mtr. , 11 mtr. along with theACSR Conductors, 11KV/33KV/LT line etc. 11KV insulator LTinsulator guard wires, staywires and other electric items of thepole coming along the alignment of the road and removal and rerollingPCC pole, MS channel different sizes as well as handingover the same to DISCOM store including transportation fromsite to store and stacking of dismantling material in store and asper the direction of Engineer Incharge and clean the site good asper the requirement and submit the receipt from DISCOM/concering authority, including all complete works.

Key Value

Document Fees
INR 500 /-
EMD
INR 30740.0 /-
Tender Value
INR 15.37 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail