Tender For Various Activities Of Development Of Distribution Infrastructure At Dholpur Circle Of Jaipur Discom Of Rajasthan State Under Rdss On Turnkey Basis Against Tn-587 - Supply of material for the various activities of development of distribution infrastructure at Dholpur Circle of Jaipur Discom of Rajasthan state under RDSS on turnkey basis. Sl. No. Item Description 1 (A)Bifurcation of 33 KV Line due to overloading 2 33 KV Bay 3 GO double break without EB Isolator for existing bracket complete in all respect as required including hardware etc. 4 33KV (with 18 x 24 KV Post Insulator ) 800 Amp. 5 33 KV UNDERGROUND CABLE 6 PCC Pole 9 mtrs long (400 KG) 7 12.8 MTR. LONG LATTICE TOWER MADE OF 65 X 65 X 5 MM M.S. ANGLE WITH 50 X 6 MM M.S. FLAT FOR BRACING With 03 NOS. of 33 KV Channel Cross Arm(100x50 mm) with 48 NOS. of Nut & Bolts(M 16x45) (Galvanized) Weight(580.827 kg) 8 UNDERGROUND CABLE FOR WORKING VOLTAGE OF 33KV ALUMINIUM CONDUCTOR (IS 7098) CABLE XLPE ARMOURED 9 Under ground Cable of Size 3X300 SQ.MM for 33 KV 10 G.I. PIPE OF 150 MM DIAMETER, B-CLASS (IS:1239 MARK) 11 GI PIPE for Cable Support at Pole ( Each 3.3 Mtr ) 12 GI PIPE for Cable Support at Tower ( Each 3.3 Mtr ) 13 CABLE END TERMINATION KIT/ST JOINT FOR 33 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE 14 XLPE 3X300 SQ.MM H.S. ON OUTDOOR TYPE 15 XLPE 3X300 SQ.MM H.S.S.T. JOINT 16 BACK CLAMP AND STAY CLAMP FOR CROSS ARMS, STAY, EARTH AND GUARDING BRACKET OF MS FLAT 17 HD GALVANISED M.S.ROD TYPE EARTHING SET MADE UP OF M.S.ROD 20 MM DIA. 3 METER LONG ALONGWITH EARTHING CLAMP & 8 SWG EARTH WIRE 15 METER LONG (FOR EARTHING OF 33 KV LINE) 18 33 KV OVERHEAD LINE WORK 19 PCC Pole 9 mtrs long (400 KG) 20 12.8 MTR. LONG LATTICE TOWER MADE OF 65 X 65 X 5 MM M.S. ANGLE WITH 50 X 6 MM M.S. FLAT FOR BRACING With 03 NOS. of 33 KV Channel Cross Arm(100x50 mm) with 48 NOS. of Nut & Bolts(M 16x45) (Galvanized) Weight(580.827 kg) 21 33 KV V cross arms with TOP Hamper made of MS Angle75X75X6 mm with clamp of size 50X10 mm,earth clamp50X6 mm with nuts, bolts & Washers as per latest specification and drawings adopted & approved by Nigam (Galvanized as per IS) 22 A SET OF 4 NOS. 33KV V CROSS ARMS(CHAKRI) MADE OF M.S. CHANNEL 100X50 MM ISMC [9.56 KG PER MTRS.] ON THE EXISTING LATTICE TOWER WITH BRACING OF M.S. FLAT ( 50 X 10 MM) INCLUDING NUT AND BOLTS ETC. WEIGHT OF THE ITEM WILL BE AS PER DRAWING 23 M.S. CHANNEL [CUT POINT ] 100X50 MM ISMC [9.56 KG. PER MTR] 2X1.8 MTRS LONG WITH PILOT PATTI 50X6MM [2.36 Kg. per mtr] THICK AND NECESSARY NUTS AND BOLTS ETC. WEIGHT OF THE CUT POINT CHANNEL WILL BE AS PER DRAWING APPX. 39.00 Kg. (Galvanized as per IS). 24 33 KV double pole line structure set (Galvanized) on 9mtrs PCC poles for cut point complete on existing poles in all respect as required made from M.S. channel 100x50 X6 mm ISMC [9.56 kg. per mtr] ISA M.S. angle 65x65x6 ,M.S. Angle 50x50x6 mm and M.S. flat 50x6 mm [excluding cost of pole] weight(130.338 kgs.) Approx 25 Porcelain 33KV Pin Insulator with Pins on pole complete in all respect 26 45KN. porcelain disc.insulators for 33 KV ( each unit consisting of 3 Nos. disc insulators & 1 Nos. B&S Type hardware) 27 GS Stay set complete with 20 mm dia., 2.4 meter long stay rod with zinc coated steel Anchor Plate of size 300x300x4 mm with square hole of size 18x18 mm at centre IN GROUND AND GS STAY WIRE 7/8 MM TIGHTENED THROUGH 33 KV STAY INSULATOR INCLUDING CLAMPS 28 6 SWG GI Wire for continuous earthing of 33 KV Line hot dip (Galvanised) as per technical specification, approved drawings and scope of work. 29 Overhead ACSR 100 Sq.mm. Dog conductor on existing cross arms complete in all respect. (Cost of material includes the sag and jumpering) 30 Overhead steel cored aluminum ACSR DOG[100SqMM(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing 31 PG clamps Dog to Dog on over headlines/jumpers, etc. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanising 32 HD GALVANISED M.S.ROD TYPE EARTHING SET MADE UP OF M.S.ROD 20 MM DIA. 3 METER LONG ALONGWITH EARTHING CLAMP & 8 SWG EARTH WIRE 15 METER LONG (FOR EARTHING OF 33 KV LINE) . 33 BACK CLAMP AND STAY CLAMP FOR CROSS ARMS, STAY, EARTH AND GUARDING BRACKET OF MS FLAT 34 33 kV Danger plate of size 200 X 250 mm complete in all respect 35 ISA M.S. ANGLE 65X65X6 MM (Galvanized as per IS) 36 8 SWG ( 4 MM DIA) GI Wire for Road/Line crossing Gaurdinghot dip (Galvanised) 37 (B)Bifurcation of 11 KV Line due to oveloading 38 11 KV Bay 39 Outdoor 11 KV O/D VCB KIOSK complete with accessories including use of special tools 40 Control Cable of size 12C X 2.5 SQ.MM. 1100 Volts PVC Insulated including supply of ferrules 41 Overhead steel cored aluminum ACSR DOG[100SqMM(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing 42 M.S. Flat 50 X 6 mm (Galvanized) 43 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length 44 Metering points on 11 KV outgoing feeder at 33/11 KV S/S.(including following cost of (a) and (b) ) 45 (a) Mounting structure (Galvanized) 46 (b) The requisite steel members will be supplied by contractor including the hardware.Contractor shall joint/weld the members to form the mounting structure as per drawing.Necessary tools,welding ,machines,lifting devics etc. shall be arranged by contractor. 47 Installation of Metering equipments: 48 11KV CT PT Set(200/5 Amp.) 49 MIP meter boxThe meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block(TTB) link type shall be provided by contractor in the meter box. 50 GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc. 51 11KV ( with 9 x 24 KV Post Insulator ) 400 Amp. GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc. 52 Horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS 53 PCC Pole 9 mtrs long (200 KG) 54 45KN. porcelain disc.insulators for 11 KV ( each unit consisting of disc insulators & one B&S Type hardware) on brackets complete including all acessories like hardware fitting etc. 55 11 KV 5KN composite polymer Pin Insulator complete in all respect 56 PG clamps Dog to Dog on over headlines/jumpers, etc. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanising 57 11 kV Danger plate of size 200 X 250 mm complete in all respect 58 ISA M.S. Channel 100X50X6 (Galvanized as per IS) 59 ISA M.S. ANGLE 65X65X6 MM (Galvanized as per IS) 60 11 KV UnderGround Cable Work 61 PCC Pole 9 mtrs long (200 KG) 62 UNDERGROUND CABLE FOR WORKING VOLTAGE OF 11KV ALUMINIUM CONDUCTOR (IS 7098) CABLE XLPE ARMOURED 63 Under ground Cable of Size 3X185 SQ.MM for 11 KV 64 G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK) 65 GI PIPE for Cable Support at Pole ( Each 3.3 Mtr ) 66 GI PIPE for Cable Support at Tower ( Each 3.3 Mtr ) 67 CABLE FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE 68 XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE 69 XLPE 3X185 SQ.MM H.S.S.T. JOINT 70 Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire 15 meter long (for earthing of 11 KV line) 71 11 KV Over Head Line Work 72 PCC Pole 9 mtrs long (200 KG) 73 11.4 MTR. Long lattice tower made of 50 X 50 X 6 MM M.S. angle with 50 X 6 MM M.S. FLAT for bracing as per nigam specification 74 11KV DOUBLE POLE LINE STRUCTURE SET FOR CUT POINT COMPLETE ON EXISTING POLES IN ALL RESPECT WITH CLAMP, NUT & BOLTS AS REQURIED MADE FROM M.S.CHANNEL 100 X 50 X ISMC ( 9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X 50 X 6 MM AND M.S.FLAT 50 X 6 MM (105 KG. APPROX.) (Galvanized as per IS)Total weight = 101.38 Kg + 4 Kg (Approx.) 75 Overhead steel cored aluminum ACSR Rabbit conductor in all respect 76 11KV Cross Arm with Top Hamper with clamps made of MS Angle 65x65x6mm, clamp 50X6 mm, earth clamp 50X6 mm (Galvanized) 77 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 78 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length 79 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 80 11 KV 5KN composite polymer Pin Insulator complete in all respect 81 PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986 82 8 SWG (4mm dia) GI Wire for continuous earthing of 11 KV Line hot dip (Galvanised) 83 11 KV Danger plate of size 200 X 250 mm complete in all respect 84 1.4 Mtr Channel bracket with clamp 85 (C)HVDS works 86 11 KV Overhead Line-1-Phase 87 PCC Pole 9 mtrs long (200 KG) 88 Overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor 89 11KV Cross Arm with Top Hamper with clamps made of MS Angle 65x65x6mm, clamp 50X6 mm, earth clamp 50X6 mm (Galvanized) 90 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 91 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 92 11 KV 5KN composite polymer Pin Insulator complete in all respect 93 LT Porcelain Pin insulators with pins 94 PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) 95 8 SWG (4mm dia) GI Wire for continuous earthing of 11 KV Line hot dip (Galvanised) 96 11 KV Danger plate of size 200 X 250 mm complete in all respect 97 1.4 Mtr Channel bracket with clamp 98 11 KV Overhead Line-3-Phase 99 PCC Pole 9 mtrs long (200 KG) 100 11.4 MTR. Long lattice tower made of 50 X 50 X 6 MM M.S. angle with 50 X 6 MM M.S. FLAT for bracing as per nigam specification 101 Overhead steel cored aluminum ACSR Rabbit conductor in all respect 102 11KV Cross Arm with Top Hamper with clamps made of MS Angle 65x65x6mm, clamp 50X6 mm, earth clamp 50X6 mm (Galvanized) 103 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 104 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length 105 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 106 11 KV 5KN composite polymer Pin Insulator complete in all respect 107 PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) com plete in all respect as required for ACSR conductor, 108 8 SWG (4mm dia) GI Wire for continuous earthing of 11 KV Line hot dip (Galvanised) 109 11 KV Danger plate of size 200 X 250 mm complete in all respect 110 1.4 Mtr Channel bracket with clamp 111 11 KV Underground Cable 112 PCC Pole 9 mtrs long (200 KG) 113 UNDERGROUND CABLE FOR WORKING VOLTAGE OF 11KV ALUMINIUM CONDUCTOR (IS 7098) CABLE XLPE ARMOURED 114 Under ground Cable of Size 3X185 SQ.MM for 11 KV 115 G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK) 116 GI PIPE for Cable Support at Pole ( Each 3.3 Mtr ) 117 CABLE FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE 118 XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE 119 XLPE 3X185 SQ.MM H.S.S.T. JOINT 120 HD Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire 15 meter long (for earthing of 11 KV line) 121 1-Phase DTR 122 PCC Pole 9 mtrs long (400 KG) 123 6.35KV/240 V aluminium wound, conventional outdoor type distribution transformers with all fittings and accessories and first filling of transformer oil alongwith MCCB. Protection on LV side confirming 124 5 KVA 125 10 KVA 126 16 KVA 127 M.S. Flat 50 X 6 mm (Galvanized) 128 6.35/0.24 KV substation structure for 5 KVA complete (galvanized as per IS) complete in all respect made of MS Channel, MS angle and MS flat etc. including nut ,bolt,flat and spring washer (as per latest specification and drawing adopted & approved by NIGAM) (36.054 Kg. + 2 Kg. approx.) 129 6.35/0.24 KV substation structure for 10/16/25 KVA complete (galvanized as per IS) complete in all respect made of MS Channel, MS angle and MS flat etc. including nut ,bolt,flat and spring washer (as per latest specification and drawing adopted & approved by NIGAM) (36.054 Kg. + 2 Kg. approx.) 130 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length 131 11 KV 100 Amp. Drop out cum isolator with 5.0 Amp. fuse & 12 KV post insulators including nut, bolt & washers as required as per technical specifications, approved drawings and scope of work. 132 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 133 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 134 11 KV 5KN composite polymer Pin Insulator complete in all respect 135 11 KV Danger plate of size 200 X 250 mm complete in all respect 136 PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 etc. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) com plete in all respect as required for ACSR conductor, 137 3-Phase DTR 138 PCC Pole 9 mtrs long (400 KG) 139 Overhead steel cored aluminum ACSR Rabbit conductor in all respect 140 LT XLPE Cable 141 Size 4CX70 SQ. mm 142 Size 4CX185 SQ. mm 143 Size 4CX120 SQ. mm 144 11 /0.4 KV Al wound, Three Phase Distribution Transformer (Completely self protected with provision of LT Bushing Box) 145 25 KVA (Aluminium) 146 40 KVA (Aluminium) 147 63 KVA (Aluminium) 148 100 KVA (Aluminium) 149 M.S. Flat 50 X 6 mm (Galvanized) 150 LT Supply Pillar Box of 200 Amp. capacity as per specification of Nigam . 151 11KV ( with 9 x 24 KV Post Insulator ) 400 Amp. GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc. 152 11/0.4 KV SubStation structure set on existing poles in all respect with clamps made from M.S. channel 100x50 X6 mm and 75x40 mm, M.S. angle 50x50x6 and M.S. flat 50x6 mm and 50x8 mm weight(166.75 kgs.) Approx (All galvanized as per relevant IS) 153 Horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS 154 LIGHTENING ARRESTOR ( FEEDER TYPE) ON ERECTED STRUCTURE / SUPPORT ( SET OF 3 NOS. ) 155 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length 156 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 157 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 158 11 KV 5KN composite polymer Pin Insulator complete in all respect 159 11 KV Danger plate of size 200 X 250 mm complete in all respect 160 PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) com plete in all respect as required for ACSR conductor, 161 (D) Cabling Works in Theft Prone Area 162 LT Ariel Bunch Cable 163 PCC Pole 9 mtrs long (200 KG) 164 Overhead ABC(Aerial bunched cable) with Bare Messenger 165 1C X25 +1CX25 sqmm 166 3C X25 +1CX25 sqmm 167 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 168 Dead end (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS) 169 Suspension (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS) 170 LT insulation piercing connectors NFC Type A (main to tap) (main 16-50 mm2, Tap off 2.5-16 mm2) 171 LT insulation piercing connectors NFC type B ( main to main) (size 16-50 mm2) 172 Spring loaded box (1 phase) 173 Spring loaded box (3 phase) 174 LT Underground Cable 175 4 Core LT XLPE insulated PVC sheathed armoured Cable 176 Size 4CX70 SQ. mm 177 Size 4CX120 SQ. mm 178 Size 4CX185 SQ. mm 179 LT DISTRIBUTION BOX AS PER SPECIFICATION OF NIGAM. 180 100 AMP LT DISTRIBUTION BOX 181 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length 182 LT Armoured Service Cable 183 2CX4 Sq MM 184 4CX16 Sq MM 185 (E)Segregation of 11 KV Ag-Non Ag Feeders 186 11 KV Bay 187 Outdoor 11 KV O/D VCB KIOSK complete with accessories including use of special tools 188 Control Cable of size 12C X 2.5 SQ.MM. 1100 Volts PVC Insulated including supply of ferrules 189 Overhead steel cored aluminum ACSR DOG[100SqMM(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing 190 M.S. Flat 50 X 6 mm (Galvanized) 191 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length 192 Metering points on 11 KV outgoing feeder at 33/11 KV S/S.(including following cost of (a) and (b) ) 193 (a) Mounting structure (Galvanized) 194 (b) The requisite steel members will be supplied by contractor including the hardware.Contractor shall joint/weld the members to form the mounting structure as per drawing.Necessary tools,welding ,machines,lifting devics etc. shall be arranged by contractor. 195 Installation of Metering equipments: 196 11KV CT PT Set(200/5 Amp.) 197 MIP meter box.The meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block(TTB) link type shall be provided by contractor in the meter box. 198 11KV ( with 9 x 24 KV Post Insulator ) 400 Amp. GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc. 199 Horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS 200 PCC Pole 9 mtrs long (200 KG) 201 45KN. porcelain disc.insulators for 11 KV ( each unit consisting of disc insulators & one B&S Type hardware) on brackets complete including all acessories like hardware fitting etc. 202 11 KV 5KN composite polymer Pin Insulator complete in all respect 203 PG clamps Dog to Dog on over headlines/jumpers, etc. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanising 204 11 KV Danger plate of size 200 X 250 mm complete in all respect 205 ISA M.S. Channel 100X50X6 (Galvanized as per IS) 206 ISA M.S. ANGLE 65X65X6 MM (Galvanized as per IS) 207 11 KV UnderGround Cable Work 208 UNDERGROUND CABLE FOR WORKING VOLTAGE OF 11KV ALUMINIUM CONDUCTOR (IS 7098) CABLE XLPE ARMOURED 209 Under ground Cable of Size 3X185 SQ.MM for 11 KV 210 G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK) 211 GI PIPE for Cable Support at Pole ( Each 3.3 Mtr ) 212 CABLE FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE 213 XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE 214 XLPE 3X185 SQ.MM H.S.S.T. JOINT 215 HD Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire 15 meter long (for earthing of 11 KV line) 216 Double break without EB Isolator on existing bracket complete in all respect as required including hardware nut, bolts & washer etc. 217 11KV ( with 9 x 24 KV Post Insulator ) 400 Amp. GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc. 218 11 KV Over Head Line Work 219 PCC Pole 9 mtrs long (200 KG) 220 11.4 MTR. Long lattice tower made of 50 X 50 X 6 MM M.S. angle with 50 X 6 MM M.S. FLAT for bracing as per nigam specification 221 11KV DOUBLE POLE LINE STRUCTURE SET FOR CUT POINT COMPLETE ON EXISTING POLES IN ALL RESPECT WITH CLAMP, NUT & BOLTS AS REQURIED MADE FROM M.S.CHANNEL 100 X 50 X ISMC ( 9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X 50 X 6 MM AND M.S.FLAT 50 X 6 MM (105 KG. APPROX.) (Galvanized as per IS)Total weight = 101.38 Kg + 4 Kg (Approx.) 222 Overhead steel cored aluminum ACSR Rabbit conductor in all respect 223 11KV Cross Arm with Top Hamper with clamps made of MS Angle 65x65x6mm, clamp 50X6 mm, earth clamp 50X6 mm (Galvanized) 224 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 225 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length 226 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 227 11 KV 5KN composite polymer Pin Insulator complete in all respect 228 PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) com plete in all respect as required for ACSR conductor, 229 8 SWG (4mm dia) GI Wire for continuous earthing of 11 KV Line hot dip (Galvanised) 230 11 KV Danger plate of size 200 X 250 mm complete in all respect 231 1.4 Mtr Channel bracket with clamp 232 3-Phase DTR 233 PCC Pole 9 mtrs long (400 KG) 234 Overhead steel cored aluminum ACSR Rabbit conductor in all respect 235 LT XLPE Cable 236 Size 4CX70 SQ. mm 237 Size 4CX185 SQ. mm 238 Size 4CX120 SQ. mm 239 11 /0.4 KV Al wound, Three Phase Distribution Transformer (Completely self protected with provision of LT Bushing Box) 240 16 KVA (Aluminium) 241 25 KVA (Aluminium) 242 40 KVA (Aluminium) 243 63 KVA (Aluminium) 244 M.S. Flat 50 X 6 mm (Galvanized) 245 LT Supply Pillar Box of 200 Amp. capacity as per specification of Nigam . 246 11KV ( with 9 x 24 KV Post Insulator ) 400 Amp. GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc. 247 11/0.4 KV SubStation structure set on existing poles in all respect with clamps made from M.S. channel 100x50 X6 mm and 75x40 mm, M.S. angle 50x50x6 and M.S. flat 50x6 mm and 50x8 mm weight(166.75 kgs.) Approx (All galvanized as per relevant IS) 248 Horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS 249 LIGHTENING ARRESTOR ( FEEDER TYPE) ON ERECTED STRUCTURE / SUPPORT ( SET OF 3 NOS. ) 250 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length 251 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 252 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 253 11 KV 5KN composite polymer Pin Insulator complete in all respect 254 11 KV Danger plate of size 200 X 250 mm complete in all respect 255 PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986 256 LT Ariel Bunch Cable 257 PCC Pole 9 mtrs long (200 KG) 258 Overhead ABC(Aerial bunched cable) with Bare Messenger 259 3C X25 +1CX25 sqmm 260 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 261 Dead end (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS) 262 Suspension (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS) 263 LT insulation piercing connectors NFC Type A (main to tap) (main 16-50 mm2, Tap off 2.5-16 mm2) 264 LT insulation piercing connectors NFC type B ( main to main) (size 16-50 mm2) 265 (F)Construction of New 33/11 KV Sub Station (RURAL) 266 5 MVA 33/11KV Copper wound Power Transformer complete with first filling of transformer oil , OFF circuit tap changer and all fittings 267 Outdoor 11 KV O/D VCB KIOSK complete with accessories including use of special tools 268 Outdoor 36 KV O/D VCB KIOSK complete with accessories 269 Control Cable of size 4 X 4 SQ.MM. 1100 Volts PVC Insulated including supply of ferrules 270 Control Cable of size 12C X 2.5 SQ.MM. 1100 Volts PVC Insulated including supply of ferrules 271 Overhead steel cored aluminum ACSR DOG[100SqMM(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing 272 Earth mesh (Galvanized) at sub-station as per approved map & design using MS Flat 50 x 6 mm & MS rod 20 mm dia (Galvanized) 273 M.S. Flat 50 X 6 mm (Galvanized) 274 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length 275 Earthing electrode shall consist of G.I. Pipe 100 mm,of 3 Mtr Length. . 276 Maintenance free Gel Earthing with Pipe in pipe / Pipe in strip technology filled with anti corrosive conductive compound ( CPRI Tested ) 277 11 /0.4 KV 25 KVA Al wound, conventional outdoor type distribution transformers with all fittings and accessories and first filling of transformer oil alongwith MCCB. Protection on LV side confirming 278 Mesh on the guarding for crossing as per standard or required as per location including binding as per drawing for road/P&T/Power line crossing 279 Metering points on 11 KV outgoing feeder at 33/11 KV S/S.(including following cost of (a) and (b) ) 280 (a) Mounting structure (Galvanized) 281 (b) The requisite steel members will be supplied by contractor including the hardware.Contractor shall joint/weld the members to form the mounting structure as per drawing.Necessary tools,welding ,machines,lifting devics etc. shall be arranged by contractor. 282 Installation of Metering equipments: 283 11KV CT PT Set(200/5 Amp.) 284 MIP meter box.The meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block(TTB) link type shall be provided by contractor in the meter box. 285 GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc. 286 33KV (with 18 x 24 KV Post Insulator ) 800 Amp. 287 11KV ( with 9 x 24 KV Post Insulator ) 400 Amp. GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc. 288 Horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. 289 33KV ( with 12 x 24 KV Post Insulator ) 1 Set=3 NOS 290 Horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS 291 11 KV ROASTER SWITCH WITHOUT ON EXISTING BRACKET COMPLETE IN ALL RESPECT AS REQUIRED INCLUDING HARDWARE NUT, BOLTS & WASHER ETC. 292 11KV DOUBLE POLE LINE STRUCTURE SET FOR CUT POINT COMPLETE ON EXISTING POLES IN ALL RESPECT WITH CLAMP, NUT & BOLTS AS REQURIED MADE FROM M.S.CHANNEL 100 X 50 X ISMC ( 9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X 50 X 6 MM AND M.S.FLAT 50 X 6 MM (105 KG. APPROX.) (Galvanized as per IS)Total weight = 101.38 Kg + 4 Kg (Approx.) 293 33 KV Sub-station type (30 KV 10 KA Station class) (1 set=3 No.) lightening arrestors on the existing brackets in all respect as required including hardware, nut , bolt & washers etc. For O&M works. 294 PCC Pole 9 mtrs long (400 KG) 295 45 KN Composite polymer insulators for 33 KV on brackets complete including all acessories like hardware fitting etc. 296 45KN. porcelain disc.insulators for 11 KV ( each unit consisting of disc insulators & one B&S Type hardware) on brackets complete including all acessories like hardware fitting etc. 297 Porcelain 33KV Pin Insulator with Pins on pole complete in all respect 298 PG clamps Dog to Dog on over headlines/jumpers, etc. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanising 299 11 KV Danger plate of size 200 X 250 mm complete in all respect 300 NEW Incoming 33 KV Feeders (RURAL) 301 33 KV Overhead Line 302 Porcelain 33KV Pin Insulator with Pins on pole complete in all respect 303 Overhead steel cored aluminum ACSR DOG[100SqMM(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing 304 PG clamps Dog to Dog on over headlines/jumpers, etc. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanising 305 GS Stay set complete with 20 mm dia., 2.4 meter long stay rod with zinc coated steel Anchor Plate of size 300x300x4 mm with square hole of size 18x18 mm at centre IN GROUND AND GS STAY WIRE 7/8 MM TIGHTENED THROUGH 33 KV STAY INSULATOR INCLUDING CLAMPS 306 6 SWG GI Wire for continuous earthing of 33 KV Line hot dip (Galvanised) as per technical specification, approved drawings and scope of work. 307 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length along with G.I wire 8 SWG (approx. total length / weight, 50 meter/4.907 Kg. ) . 308 11 KV OUTGOING FEEDERS (INTERCONNECTION): 309 11 KV Over Head Line Work 310 PCC Pole 9 mtrs long (200 KG) 311 11KV DOUBLE POLE LINE STRUCTURE SET FOR CUT POINT COMPLETE ON EXISTING POLES IN ALL RESPECT WITH CLAMP, NUT & BOLTS AS REQURIED MADE FROM M.S.CHANNEL 100 X 50 X ISMC ( 9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X 50 X 6 MM AND M.S.FLAT 50 X 6 MM (105 KG. APPROX.) (Galvanized as per IS)Total weight = 101.38 Kg + 4 Kg (Approx.) 312 Overhead steel cored aluminum ACSR Rabbit conductor in all respect 313 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 314 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 315 11 KV 5KN composite polymer Pin Insulator complete in all respect 316 PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986 317 8 SWG (4mm dia) GI Wire for continuous earthing of 11 KV Line hot dip (Galvanised) 318 11 KV Danger plate of size 200 X 250 mm complete in all respect 319 12.8 MTR Long lattice tower made of 65X65X5 MMangle with 50X6 MM M.S flate for bracing with 03 nos KV Channel cross arm ( 100X 50 MM) with 48 nos of nut & Bolt ( M 16X45) ( Galvanized) weight (580.827Kg) 320 M.S. Channel (CUT Point) 100 X 50 MM ISMC (9.56 kg Per meter) 2X1.8 Mtrs long with pilot patti 50X6 MM (2.36 Kg per Mtr ) Thick and necessary nut and bolts etc weight of cut point channel will be as per Drawing appx. 39 kg ( Galvanized as per IS) 321 1.4 Mtr Channel Bracket with clamp 322 11.4 MTR. Long lattice tower made of 50 X 50 X 6 MM M.S. angle with 50 X 6 MM M.S. FLAT for bracing as per nigam specification 323 11 KV Cross arms with top hamperswith clamps made of MS angle 65X65X6 MM, clamp 50X6 MM, earth clamp 50X6 MM (Galvanized) 324 Earthing rod sets for s/s made with MS rod ( Galvanized) 20 MM dia, 3 Meter length.