Purchase Of Generator For Office , Sitc Of 30 Kva Dg Set , Od163528/2024-2025:Supply, Conveyance Installation, Testing And Commissioning Of 30 Kva Diesel Generator Set, 3 Phase, 415V, 50Hz, 0.80 Pf, Liquid Cooled Ley Power Rtu Diesel Generator For Producing Electricity Including Standard Control Panelwith Integral Acoustic Enclosure As Per Cpcb Norms And As Per Technical Details Given Below Including Loading ,Unloading And Transporting Etc. Make & Type Of Engine- 4 Cylinder Ashok Leyland - Cpcb4+ Diesel Engine Model (P15g4de30 )Developing 37 Bhp At 1500 Rpm Under Ntp Condition Or Equivalent Make, Make Of Alternator - Ashok Leyland Ley Power Alternator ( Leroy Somer) Or Equivalent Make,System Of Voltage - 3 Phase,415 V, 50 Hz ,4 Wire System ,Standard Control Panel Including 4 Pole Mccb As Per Standards With All Standard Accessories Such As Ammeter, Volt Meter, Frequency Meter, Energy Meter And Suitable Earth Fault Relay Etc. Suitable Size Built In Type Integrated Fuel Tank With Connection Shall Be Done As Per Standards. Suitable Capacity Fully Charged Battery With Leads And Terminals Of Appropriate Ah Capacity As Per Manufactures Requirements With Trickle Charging Charger And Connections. , Od163527/2024-2025:Supply, Installation, Testing And Commissioning Of 63Afor Pole Automatic Transfer Switch In Sheet Steel Enclosure With Automatic And Manual Range Suitable For 4 Pole Ac 32B/Ac 33B, 50 Hz, 415 V Ac Supply With Standard Accessories And Phase Indication Lamps, Single Phasing Preventerand Wire Harness/ Cable End Box Etc. Havells Or Equivalent Make . , Od163525/2024-2025:Supply, Conveying & Fixing 80 Mm Dia Exhaust Pipe Made Ofisi Marked Tata/ Jindal /Equivalent Make Ms Pipe Having Sheet Thickness 6.35 Mm And Cutting In To Required Length, Facing The Cutting Edges And Supply And Providing Ms Flanges Having 12 Mm Thickness And Minimum 75 Mm Depth On Both Ends Of Every 2 Mtr Or Nearest Long , Including Conveyance Charges To Pumphouse And Labor Charges For Loading, Unloading, Fixing On Alignment For Suction/Delivery Side Pipe Using Suitablepacking Etc. Painting With Two Coats Of Aluminum Paint Over A Coat Of Red Oxide Primmer Etc. Complete. , Od163526/2024-2025:Supply Of High Speed Diesel , 14.1:Excavation For Foundation In Soft Soil Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 Metres. , 14.7:Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) In Foundation Of Pump, Dg Set Etc Including Form Work Etc As Required. , 14.8:Providing And Laying In Position Cement Concrete 1 :3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) In Foundation Of Pump, Dg Set Etc. Including Form Work Etc. As Required. , 14.11:Providing Brick Work (In Width 225 Mm Or More) With F.P.S. Bricks Of Class Designation 7.5 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) At All Levels. , 14.12:Providing 15Mm Thick Cement Plaster Of Mix 1:4(1 Cement: 4 Fine Sand) At All Levels , 14.13.1:Providing, Laying And Fixing Following Dia G.I. Pipe (Medium Class) In Ground Complete With G.I. Fittings Including Trenching (75 Cm Deep)And Re-Filling Etc As Required50 Mm Dia , 90.12.5.2:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1Kv Grade Of The Following Sizes In The Existing Rcc/ Hume / Stone Ware/ Gi/ Dwc Pipe As Required.2 Core 6 Sq Mm , 90.12.7.42:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 25 Sq Mm With Factory Made Clamp , Od163597/2024-2025:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Copper Control Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 1.50 Sq Mm With Factory Made Clamp , 90.12.10.3:Supply & Laying Of Dwc Pipe In Ordinary Soil 0.75M Below Ground Level Including Excavation63/50 Mm Or Nearest Size , 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 90.16.1.5:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required4.75 Mm Copper Conductor (6 Swg) , 90.16.2.3:Supply And Laying Of The Following Sizes Of B Class Gipipe Laid 0.6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc, As Required.32 Mm Dia G.I Pipe ( Medium Class) , 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm (10 Swg) , 90.16.5.5:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.4.75 Mm (6 Swg) , 5.4:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , 5.9:Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required.(Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm) , 90.16.3.9:Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Colour Washing Etc. As Required ( For Horizontal Run)25 X 3 Mm Copper Strip , Od163572/2024-2025:Supply And Fixing 25X6 Mm Brass Bolt, Nut And Washer , 2.10.4:Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, &Quot;C&Quot; Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole , 2.15.3:Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps , 90.11.1.19:Supply And Installation Ofsheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required6 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , 90.14.10.2:Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required.16 A-100A, 25/35 Ka (Ics=100%Icu), 3 Pole, Current Limiting Type Mccb Having Thermal Setting Range Of 80 - 100% With Thermal Magnetic Release Having Adjustable Ol , Od163574/2024-2025:Supply And Fixing Hot Press Molded Smcmeter Box Size 650X350x250 Mm Sintex Make Gs-Mb- 6535 Or Equivalent Make , Od163575/2024-2025:Supply And Fixing 100 A 2 Way Neutral Link On Smc Or Dmc Base And Giving Connections , Od163576/2024-2025:Supply And Fixing 100 A Fuse Unit With Hrc Link On Existing Board Using Suitable Bolt , Nut And Giving Connections , 9.1.1:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.2 X 6 Sq. Mm (19Mm) , 9.1.34:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 25 Sq. Mm (28Mm) , Od163600/2024-2025:Supply And Fixing , 60 Mm Long X 20 Mm Wide X 1.20 Mm Thick Copper Earthing Clips For 25 Sq. Mm To 95 Sq. Mm Single Compression Glands , Od163601/2024-2025:Supply And Fixing60 Mm Long X 12 Mm Wide X 1 Mm Thick Copper Earthing Clips For 4 Sq Mm To 16 Sq Mm. Single Compression Glands , Od163602/2024-2025:Painting Letters Or Figures Of The Following Sizes With Enamel Paint As Identification Mark To Sb, Db, Panel Board Etc As Required 2.50 Cm, 4 Cm Or 5 Cm Height , Od163603/2024-2025:Supply And Providing First Aid Chart ( Shock Treatment Chart ) Pvc Laminated /Duly Framed And Placed In A Conspicuous Location For Clear Vision. , Od163604/2024-2025:Supply And Providing 2 Mm Thick Elastomeric Fire Retardant Insulating Mat As Per Is 15652/2006 To Withstand 3.3 Kv Dielectric Strength. , Od163605/2024-2025:Supply And Providing 9 Litre Capacity Gi Fire Bucket Painted In Post Office Red With Primer Coat Of Red Oxide And Written With White Paint 'Fire' Mounted On Ms Angle Frame Work/ Wall Bracket Filled With Fine Sand, Painting The Bracket/ Floor Stand Including Making Good The Damages, Colour Washing Etc. As Required. , Od163606/2024-2025:Supply And Providing 6 Kg. Dry Chemical Powder Type Fire Extinguisher With Hose And Clamps Including Fixing It To Wall As Required. , Od163614/2024-2025:Preparation Of Drawings Including Schematic Circuit Diagram And Necessary Approval From The Electrical Inspectorate Etc. ( Actual Amount Paid On Production Of Original Bill/Invoice/Challan )