}

Tender For Provision Of Non-Tech Store At Hq Sac (U) Under, trivandrum-Kerala

Military Engineer Services has published Tender For Provision Of Non-Tech Store At Hq Sac (U) Under. Submission Date for this Tender is 12-02-2025. Excavation Work Tenders in trivandrum Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

47339100
Tender For Provision Of Non-Tech Store At Hq Sac (U) Under
Open Tender
NCB
Kerala
Trivandrum
12-02-2025

Tender Documents

Tender Details

Tender For Provision Of Non-Tech Store At Hq Sac (U) Under; 1 Excavating in trenches , n exc 1.5 m wide and n exc 1. 5 m in depth for foundation/cable etcn exc 10 SqMon plan and n exc 1,5 m in depth and getting outHard/dense soil, complete all as specified and directed. 2 Removing excavated materialexc .250m butn exc 500 m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and dircted. 3 Returning filling in including spreadng levellin watering and well ramming in layers not exc 25 cm, complete all as specified and directed. 4 M&L, for laying PCC 1:4:8 (40mm graded aggregate) type D-2Cement concrete in foundations, filling and mass concrete, complete all as specified and directed. 5 M&L for Mild steel bars TMT Bars( grade CRS) 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with, complete all as specified and directed. 6 M&L for Mild steel bars TMT Bars (Grade CRS) 6mm dia to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. 7 M&L for Mild steel bars TMT Bars (Grade CRS) 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. 8 M&L, for Reinforced cement concrete (design mix) RCC M-30 (using 20 mm graded stone aggregate ) in foundation footing , plinth beams, base of column , under reamed piles and mass concrete, complete all as specified and directed. 9 M&L Reinforced cement concrete (design mix)M-30(using 20 mm graded stone aggregate )Columns, pillars, piers, posts and struts, complete all as specified and directed. 10 M&L Reinforced cement concrete (design mix) M-30(using 20 mm graded stone aggregate ) in lintels, Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed. 11 M&L Reinforced cement concrete (design mix) M-30(using 20 mm graded stone aggregate ) in chajja, complete all as specified and directed. 12 M&L Reinforced cement concrete (design mix)M-30(using 20 mm graded stone aggregate ) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. 13 M&L, Formwork to Rough finished surfaces of concrete , sides of concrete foundations, footings,bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams ; and similar work with rough finished flat surfaces of concrete, complete all as specified and directed. 14 M&L, formwork to Rough finished surfaces of concrete , sides of pillars, posts, struts, piers, columns and stanchions rough finished square, rectangular or polygonal surfaces of concrete, complete all as specified and directed. 15 M&L, Form work to Rough finished surfaces of concrete, chullah hoods, chajjas & similar work including edges with rough flat finished surfaces of concrete, complete all as specified and directed. 16 M&L, Form work to Rough finished surfaces of concrete lintels & roof beam, complete all as specified and directed. 17 M&L for Form work to soffits of roof slabs, floor slabs, landings etc & similar work n. exc 200mm thickwith fairfinished on flat surfaces of concrete horizontal or sloping, complete all as specified and directed. 18 M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete built in CM 1:6 complete all as specified and directed. 19 M&L, for rendering 15mm thick in CM 1:6 on concrete surface of internal wall including finish even and smooth surfaces using without extra cement. 20 M&L, for rendering 20mm thick in CM 1:4 in two layer oncement conrete or brick work including finish even and smooth surfaces using without extra cement with using WPC in Second layer of 10mm thick rendering. (WPC shall be measured separately). 21 WPC on external wall (Liquid water proofing compound) (Using wpc as per manufacturer instructions is @ 200ml/50 kg or per cement bag) 22 M&L, for rendering 5 mm thick in CM 1:3 on concrete surface of ceiling including to be finished even and smooth surfaces without using extra cement 23 M&L, for rendering 5 mm thick in CM 1:3 on concrete surface of wall and concrete (i.e RCC Columns) including to be finished even and smooth surfaces without using extra cement, complete all as specified and directed. 24 M&L Roof tiles, Mangalore pattern, inter locking at side joints, laid and fixed on 15 mm thick screed bed complete all as specified and directed. 25 M&L Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and pointed in cement mortar 1:6 complete all as specified and directed. 26 M&L for 3mm wall care putty on wall, complete all as specified and directed. 27 M&L for preparation of new treated of wall surfaces and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed. 28 M&L, Preparing of newly plaster surface of Ceiling / Priming plastered and other surfaces with alkali-resistant priming paint and Distemperingwith Two Coats of distemper oil emulsion. Complete all as specified and directed. 29 M&L,Preparation of newly plastered or unplastered surface and applying two coats of weather proof paint to external surface using Apex ultima or equivalent paint. Complete all as specified and directed. 30 Preparation of Newwooden surfaces , applying priming coat red oxide primer and 2 coats of synthetic enamel paint, complete all as specified and directed. 31 Preparation of New steelsurfaces , applying priming coat with pink primer and 2 coats of synthetic enamel paint, complete all as specified and directed. 32 M&L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface 75 mm (Broken stone or boulders) , complete all as specified and directed. 33 M&L, 75mm thick pcc 1:3:6 type-C-2 in plinth protection 40mm graded aggregate with necessary form work, complete all as specified and directed. 34 M&L, 100mm thick pcc 1:3:6 type-C-2 in under floor 40mm graded aggregate as in floor subbase 35 M&L,Non skid ceramic tiles 7 to 8 mm thick are of each tile exc .18 sqm and n exc .38 sqm in floors set and jointed in cement slurry over 15 mm thick screed bed morta CM 1:4, complete all as specified and directed. 36 s & Fsteel rolling shutter1.25 mm thick gear operated type as spd including top cover , anchoring rod, hasp stale and one coat of primer erected in position as indicated complete 37 Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 42x50 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 Nos stainless steel hinges fixd to frame complete all as spd and as direction of EIC 38 Providing and fixing factory made uPVC white colour casement(Openable) Door made of extruded profilewilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame(60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x74mm). Glazing bead (35mm x 20mm) will be miteredcut and fusion welded at all corners, includingdrilling ol holes for fixing hardware and drainage ofwater etc., making arrangement for fixing of hardware.EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), Tprofile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated).Corner striker. Secondary Strikers. Cylinder Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) 39 Providing and fixing factory made uPVC white color Sliding window Two track made of extruded profiles with wall thickness of 2.3mm (+0.2mm). Window profile with hollow section with multi chamber, Frame(60mm x 62mm). sash (42mm x 67mm). Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm). Glazing bead (24.5mmx 16mm) will he mitered cut and fusion welded at all corners,including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel frame (30mm x 21.5mm), Sash (30mmx 18mm), profile to be inserted in required profile,frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware : [Touch Lock of zinc alloyed(white powder coated), steel roller system including 5mm thick glazing with selected quality glass,aluminum track on bottom rail for two track sliding frame, wool pine for Sliding sash and interlock.](Note: The unit rate quoted by contractor excludes cost of glass and includes all other connectedaccessories. Net opening will be measured forpayment purpose)(A) Area not exceeding 2.00 sqm each. 40 M & L framed work such as grills , grating etc.. With ends of bars shouldered and /or riveted, or forged into spikes , framed guard barsto Fe 290 Gde E-165, complete all as specified and directed. 41 M&Lfor provn of water proofing roof treatment to RCC roof with APP modified membrane with non woven polyester reinforced wt not less than 3 Kg/Sqm of thickness not less than 3 mm having thermalinsulation with white mineral/ gravel finish on upper side of membrane uniformly embedded during manufacturing process . All as per following specifications:(a) The surface of the roof, parapet and gutters, drain mouths etc. over which water proofing treatment is to be applied shall be cleaned of all foreign matters such as fungus, mass, dust etc. by wire brushing and dusting. For cast iron drain outlets the grove shall be cut around to tuck in the treatment as pipes, chimneystacks etc. and other similar situations to ease up about corners.(b)Bituminous primer conforming to IS : 3384-1965 oil bound bitumen primer @ 0.20kg per sqm and applying a coat blown grade hot bitumen 85/25 or 90/15 @ 1.20 kg/sqm to be applied an prepared surface till the surface is properlyimpregnated. 42 (c) APP modified water proofing membrane as specified shall be laid on the primer surface by torch application method as per manufacturers instructions, The overlaps while torching shall be 100 mm in both directions(longitudinal and transverse directions). All overlap joints shall be sealed thoroughly by thermofusing both the membrane layers and sealing it with the help of hot trowel. The overlap joints shall be made as monolithic layer. (d) All joints& changes in direction should be curved with cement morar 1:3 mixed with SBR latex @ 200 ml per beg of cementand cured well before laying the membrane.(e)Apply one coat of solar reflective bituminous aluminium paint @ 100 gm per sqm over a coat of aluminium red oxide primer on the APP membrane, complete all as specified and directed by Engr-in-Charge. 43 M&L, Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured 44 M&L, Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface 45 M&L, Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area 46 M&L, Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall 47 M&L Preparation of New or old steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified anddirected 48 S & F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square in exc 0.5 sq.m in each pane 49 S& F Framed work such as grills,and similar work conforming to Fe 290 Gde E-165 50 M&L for submain wiring in PVC conduit with two runs of 4 Sq mm and one run of 4 sqmm for earth continuity 1100 v grade PVC insulated unsheathed FRLSH grade copper conductor cable single core multistranded drawn through and including 25 mm dia PVC rigid connduit includung accessories such as bends, supports etc all as specified 51 M& L for RCCB 2 pole 25 A, 240 volts, short curcuit current 100mA capacity, confirming to IS/IEC 12640-1 all as specified. 52 M& L for AC box modular socket type with MCB SP 25 amps 10 KA operating on 240 volts AC. Make : Havells 25 A DBOXX MCB Socket, DHDMCSN0251025 or Equivalent 53 Supply and install testing, commissioning of Split AC with inverter type, Variable speed compressor which adjusts power depending on heat load, convertible / adjustable with 4 cooling modes through remote control to operate in different tonnages for different cooling needs, comprising of indoor unit with dust Filter, Anti-bacterial Filter & outdoor unit with Copper Condenser Coil, single phase 230V, 50Hz complete with cordless remote control unit of high EER rated BLDC compressor, including inter connection cable of suitable size, necessary fixing arrangement complete unit shall be placed at suitable position and height inside the room and outdoor unit at suitable place outside the room on plinth height / on wall or roof as suitable and including voltage stabilizer of suitable capacity, metallic bracket with fixing bolts for outdoor unit, insulated copper piping etc., Refrigerant R410-A/R32 of cpapcity 1.50 TR (copper type) 5 star rated complete all as specified and directed.Note: 1 Year Comprehensive Warranty on the Product and 10 Years on Compressor 54 Supply and lay in trenches burnt bricks sub-class ‘B’ sizefor cable protection complete all as specified and directed 55 M&L for in replacement GI pipe 50 mm dia light grade laid in trenches at road crossings/ foot paths complete all as specified and directed 56 M&L for road cutting, including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boulders/ stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work, complete all as directed. 57 Supply and laying in trenches or passing through pipes/ poles, wall/roof etc LT XLPE cable heavy duty 1100 Volts grade withmultistrandedaluminium conductor, armouredincluding provn of cable lugs and glands as required complete all as specified and directed of following sizes:- 58 4 core 10 sq mm 59 4 core 16 sq mm 60 Supply and fixing in replacement HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 140 mm x 140 mmx 95 mm incl4 way heavy duty terminal block with 01x MCB 10 Amps SP, 10 KA and two number of PVC cable entry gland of standard size with suitable GI bracket to fix with pole, including taking down existing complete all as directed. Make: Sintexor equivalant in Hansel 61 M& L for3 core 1.0 Sqmm multistranded copperconductor PVC insulated unsheathed cable to connect from junction box to street light fitting drawn through and including rigid non metallic PVC conduit medium grade fixed on pole by means of clamps made out of MS flat irons and connecting from terminal box to light fitting and testing including taking down perished wiring complete all as directed complete all as specified and directed. 62 Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed. 63 Supply and fix Hotdip Galvanised Octagonal pole 7 meter. ( Top dia 70 mm and bottom dia 130mm and 3 mm thick with base plate size 220mm x 220mm x 12 mm thickness, foundation nut bolt ( 20mm dia x 750mm) with single arm bracket including earth work excavation of 0.60x0.60x0.80 deep foundation concrering in PCC 1:3:6, base connecting (coping) of 40x40x30 cm (pole to be fitted over this PCC ) in PCC 1:2:4 and removal of excavated earth etc , complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 42260.0 /-
Tender Value
INR 21.13 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail