}

Installation Of Yard Lighting Arrangement, Electrical Wiring Of Pump House And Other Allied Works At Churulia Pump House Under Augmentation Of Churulia Piped Water Supply Scheme., Bardhaman-West Bengal

Public Health And Engineering Department has published Installation Of Yard Lighting Arrangement, Electrical Wiring Of Pump House And Other Allied Works At Churulia Pump House Under Augmentation Of Churulia Piped Water Supply Scheme.. Submission Date for this Tender is 17-03-2025. LED Light Tenders in Bardhaman West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

47305452
Corrigendum : Installation Of Yard Lighting Arrangement, Electrical Wiring Of Pump House And Other Allied Works At Churulia Pump House Under Augmentation Of Churulia Piped Water Supply Scheme.
Open Tender
NCB
West Bengal
Bardhaman
17-03-2025

Tender Documents

Tender Details

Installation Of Yard Lighting Arrangement, Electrical Wiring Of Pump House And Other Allied Works At Churulia Pump House Under Augmentation Of Churulia Piped Water Supply Scheme.- 1 Supply and Delivery of Following Materials at site:- 2 70 Watt. LED Highly efficient IP66 LED street-light with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution,higher spacing between poles and maintenance-free system.(Make-Approved Make) 3 4 ft. long 22 Watt LED Tubelight Slim LED batten with aluminium housing and polycarbonate diffuser is an ideal replacement solution for existing battens/fluorescent lamps with elegantlydesigned end caps.(Make-Approved Make) 4 4 Core X 10 Sqmm, 1.1 KV Grade XLPE insulatedAl.Ar Cable.( From LT MCC Panel feeder to DBs)(Make:-Approved Make) 5 450 mm Sweep exhaust fan 220V-240 V,50 Hz, Single phase.(Make:-Approved Make) 6 3 CoreX 1.5 Sqmm industrial flexible copper cable wire/dia-30/0.25 PVC insulated with PVC sheathed.(Make:Approved Make)(For 8 Nos Street light from Roof of the building) 7 4 Core X 4 Sqmm, 1.1 KV Grade XLPE insulatedAl.Ar Cable.(From DBs to Street light outside of the Pump House )(Make:-Approved Make) 8 100 Watt High efficiency round LED high-bay luminarie with aluminium die cast housing with high lumen efficiency of>130 lm/Watt, a perfect energy-saving solution with IP65 Protection.(Make-Approved Make) 9 30 Watt. LED Highly efficient IP66 LED street-light with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution,higher spacing between poles and maintenance-free system.(Make-Approved Make) 10 Supplying and fixing double door 8 Way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(With 40 Amp TPN MCB as a incomer + 8 Nos 10 Amp MCB as a Outgoing)(Make-Havells, Model No-DHDPTODRW08) 11 Supply of 25 mm dia GI Conduit 1.6mm thick.(Approved make) 12 Supply of GI Bend/Elbow. 13 Supply of GI saddle etc … 14 Two way Circular Box & cover. 15 One way Circular Box & cover. 16 3 way Ceiling Rose/Batten Holder. 17 Labour for fitting and fixing 25 mm dia 1.6mm thick G.I. Conduit above ground (exposed) in the wall with previously supplied saddle clamps including cost of jointing materials,holder bat clamps etc.,as necessary, including cutting pipe, making threads etc. complete in all respect with two coats of painting with approved paint any height. 18 Supplying and Drawing 1.1 KV single core stranded FRPVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 19 3 X 22/0.3(1.5 Sqmm).(For lighting Fixtures) 20 3 X 36/0.3(2.5 Sqmm).(For Exhaust Fans+3 Nos Highbay) 21 3 X 56/0.3(4 Sqmm).(For industrial Plug Sockets) 22 Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 23 12 Module. 24 8 Module. 25 6 Module. 26 Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required.(26 Nos For Pump House) 27 Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. 28 Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. 29 Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated and sheathed wire (single core) from loop box at the base of pole to light fiting through pole & bracket (without control switch) including making connections & painting. (For 8 Nos Street Light+1 for Outer Premises) 30 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:45 cm (18). 31 Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long).(6 Nos for Pump House) 32 Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc. 33 Fixing only Floodlight/High Bay Fitting with suitable tie clamps and MS plate for mounting top of the Ceiling or similar structure. 34 Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below,Comprising of one 250 V,15 A Kit-Kat fuse unit, one NL on,porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1)after dismantling the damaged looping cable box etc. where necy. incl. painting. 35 200 x 150 x 100mm.(For 8 Nos Street Light+1 No for Outer premises) 36 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. 37 Supplying and fixing 32 Amp Sheet steel Main Switches on flat iron frame on wall 415V TPN with fuse on L&N.(Make-Approved Make)(For Chlorine Room) 38 Distributionwiring in 1.1 KVsingle core stranded FRPVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make) incl. necy. fittings as required. 39 2 X 22/0.3(1.5 Sqmm)+1 X 22/0.3(1.5 Sqmm)ECC. 40 Connecting the pole to earth busbar including S & F GI(Hot Dip) wire of size as below,spiral on pole body as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. 41 No. 12 SWG. 42 Earthing with GI earth spike(1822mmX20 mm) and grouted the same under the ground level as per direction. 43 Add GST @ 18% 44 Add CESS @ 1%

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 10-02-2025 Corrigendum Date 25-02-2025
2 25-02-2025 Date Corrigendum Date 17-03-2025

Key Value

Document Fees
Refer document
EMD
INR 8500.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail