| Sl. No. | Item Description |
| 1 | Dismantling and opening of spare parts for servicing of water cooled DG set of following capacity coupled with alternator, Maintenance and servicing mechanically and electrically, including cleaning, oiling /greasing,removing & replacement of defective / unserviceable parts with new parts,i.e diesel filter /oil filter /Air filter /fan belt /fuel pipe/ engine oil pipe /Engine Oil/distilled wateretc as required at site andas per manufacturer\"s instructions and checking of valves & nozzles etc, reassembling the parts of DG set at position ensuring proper alignmentconnecting to existing system and making DG set perfectly operational and testing at site connected load to the entire satisfaction of complete all as specified and directed. (including mentioned inNote here in below) Notes:-(i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall bemeasured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc. (ii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump by pouring kerosene oil complete all as specified and directed(iii) Fresh engine oil for DG sets shall be supplied by the contractor as “ Supply only” and shall be measured and paid separately under appropriate item of Sch ‘A’ . Its cost of filling is deemed to be included under the rates quoted by the contractor for above item. |
| 2 | 62.5 KVA to 140KVA,3 phase 50 HZ,Make: CUMMINS/Kirloskar |
| 3 | 160 KVA to 320KVA3 phase 50 HZMake: CUMMINS/Kirloskar / Greaves /Caterpillar |
| 4 | 365 KVA to 400 KVA3 phase 50 HZMake: CUMMINS/Kirloskar / Greaves /Caterpillar |
| 5 | 500 KVA 3 phase 50 HZ, Make :Cummins |
| 6 | Supply only element diesel filter with gasket suitablefor following capacity of DG set dismantled / fixed under Sch `A` item No1.00 here in above complete all as specified and directed. |
| 7 | 62.5 KVA to 140KVA,3 phase 50 HZ,Make: CUMMINS/Kirloskar |
| 8 | 160 KVA to 320KVA3 phase 50 HZMake: CUMMINS/Kirloskar / Greaves /Caterpillar |
| 9 | 365 KVA to 400 KVA3 phase 50 HZMake: CUMMINS/Kirloskar / Greaves /Caterpillar |
| 10 | 500 KVA 3 phase 50 HZ,Make :Cummins |
| 11 | Supply only element Oil filter with gasket suitablefor following capacity of DG set dismantled/fixed under Sch `A`item No1.00 here in above complete all as specified and directed. |
| 12 | 62.5 KVA to 140KVA,3 phase 50 HZ,Make: CUMMINS/Kirloskar |
| 13 | 160 KVA to 320KVA3 phase 50 HZMake: CUMMINS/Kirloskar / Greaves /Caterpillar |
| 14 | 365 KVA to 400 KVA3 phase 50 HZMake: CUMMINS/Kirloskar / Greaves /Caterpillar |
| 15 | 500 KVA 3 phase 50 HZ, Make :Cummins |
| 16 | Supply only Air cleaner element primary and safety for following capacity of DG set dismantled/fixed under Sch `A` item No1.00 here in above complete all as specified and directed. |
| 17 | 62.5 KVA to 140KVA,3 phase 50 HZ,Make: CUMMINS/Kirloskar |
| 18 | 160 KVA to 320KVA3 phase 50 HZMake: CUMMINS/Kirloskar / Greaves /Caterpillar |
| 19 | 365 KVA to 400 KVA3 phase 50 HZMake: CUMMINS/Kirloskar / Greaves /Caterpillar |
| 20 | 500 KVA 3 phase 50 HZ, Make :Cummins |
| 21 | Supply only corrosion resistor filter with gasket and CR plate for 200 to500KVA3 phase 50 HZMake: CUMMINS/Kirloskar of DG set dismantled/fixed under Sch `A` item No1.00 here in above complete all as specified and directed. |
| 22 | Supply only element bypass filter with gasket for 100 KVA to 500 KVA capacity DG Set dismantled/fixed under Sch `A` item No1.00 here in above complete all as specified and directed. |
| 23 | Supply,installation,testing and commissioning in replacement ofunserviceableAVR unit suitablefor 3 phase 50 HZalternator suitable for 62.5 KVA to 500KVA capacity of DG set complete all as specified and directed. |
| 24 | Dismantling and taking out the radiator fitted infollowing capacity of DG sets and strip opening complete radiator assembly,for servicing mechanicallyandproper cleaning of tubes with using de-scaling solution,including repair of water tubes and top/ bottom tanks by soldering / gas welding of leakage of tubes/tanks. including replacement of gasket, nut bolts,etc ensuring perfectly leak proof after servicing of radiator,re-assembling and fixing the same in position and testing the system complete all as specified and directed .Notes :- (i) Repairs/servicing/re-assembling and testing of radiator shall be carried out through a authorised representative of manufacturer.(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, gaskets/ packing etc.(iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre. |
| 25 | 62.5 KVA to 140KVA,3 phase 50 HZ,Make: CUMMINS/Kirloskar |
| 26 | 160 KVA to 320KVA3 phase 50 HZMake: CUMMINS/Kirloskar / Greaves /Caterpillar |
| 27 | 365 KVA to 400 KVA3 phase 50 HZMake: CUMMINS/Kirloskar / Greaves /Caterpillar |
| 28 | 500 KVA 3 phase 50 HZ, Make :Cummins |
| 29 | Supply only the following items/spare parts suitableforraditor of DG setof the following variuos capacity dismantled/fixed under Sch `A` item No 8.00 here in above complete all as specified and directed.Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A\" item No 8.00 here in above.(ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item. |
| 30 | Radiator hose set with clamp complete set for 62.5 KVA to 140KVA 3 phase 50 Hz DG Set. |
| 31 | Radiator hose set with clamp complete setfor 160 KVA to 320 KVA 3 phase 50 Hz DG Set. |
| 32 | Radiator hose set with clamp completeset for 365 KVA to 500 KVA 3 phase 50 Hz DG Set. |
| 33 | Water pump assemblycompleteset for 62.5 KVA to 250 KVA 3 phase 50 Hz DG set |
| 34 | Water pump assemblycomplete set for285 KVA to 500 KVA DG set 3 phase 50 Hz, DG setcomplete. |
| 35 | Supply only concentrated coolent suitable for radiator of DG setany capacity drained out / filling under Sch `A`item No1.00 here in above complete all as specified and directed. |
| 36 | Supply only lubrication oil API-CF ( 20 W- 40 multigrade)suitablefor Engine of DG setany capacity drained out / filling under Sch `A` item No1.00 here in above complete all as specified and directed. |
| 37 | Supply only lubrication oil SAE-CI4 ( 15 W- 40 grade)suitablefor Engine of DG setany capacity drained out / filling under Sch `A` item No1.00 here in above complete all as specified and directed. |
| 38 | Supply only distilled water Complete, all as specified and directed by Engr-in-Charge, |
| 39 | Dismantling and taking out the PT fuel system including injectors assembly fitted in following capacity of DG sets 3 phase 50 HZof DG setand strip opening of PT fuel system including injectors assemblyfor carrying out repair/ servicing /overhauling mechanically ,cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, complete and calibration of Fuel Injection after repair/ servicing /overhauling and re-assembling and fixing the same in position and testing complete all as specified and directed .Notes :- (i)Repairs/servicing / reassembling and testing of Fuelinjectorpump shall be carried out through a authorised service center ontesting machine.(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall bemeasured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, `O’ rings, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre. |
| 40 | 62.50 KVA to 200KVA3 phase 50 HZ, Make: CUMMINS/Kirloskar |
| 41 | 250 KVA to 500KVA3 phase 50 HZ , Make: CUMMINS/Kirloskar |
| 42 | Supply only the following items/spare parts suitablefor PT fuel system including injectors assembly of DG set of capacity 100 to 285 KVA, 3 phase,50HZ for capacity dismantled/fixed under Sch `A` item No 39.00 here in above complete all as specified and directed.Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A\" item No 39.00 here in above.(ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item. |
| 43 | Kit injector barrel plunger |
| 44 | Kit Gasket Governor set |
| 45 | Ball Bearing |
| 46 | Gasket fuel pump . |
| 47 | Screen filter . |
| 48 | Ball check . |
| 49 | Gasket Injector . |
| 50 | Seal ‘O’ ring . |
| 51 | Pump gear fuel . |
| 52 | Shaft fuel pump drive . |
| 53 | Shaft tachometer drive . |
| 54 | Bushing tachometer drive. |
| 55 | Plunger governor . |
| 56 | Plug injector orifice. |
| 57 | Screen filter. |
| 58 | Seal dust. |
| 59 | O Ring injecter. |
| 60 | Kit seal . |
| 61 | Supply , fixing, connecting and testing in replacement offollowing unserviceablespare parts ofsuitable for DG set of62.50to 500 KVA capacity,3phase,50HZcomplete all as specified and directed. |
| 62 | Seal key way. |
| 63 | Water separator . |
| 64 | Oil temperature gauge. |
| 65 | Water temperature gauge. |
| 66 | Oil pressure gauge 0 to 7 kg/cm2 . |
| 67 | Hours meter. |
| 68 | Hump hose & bend |
| 69 | Toggle switch |
| 70 | Elbow male union. |
| 71 | Dust cap. |
| 72 | Ignition switch along with duplicate keys. |
| 73 | Switch Temp . |
| 74 | Switch pressure . |
| 75 | Diaphramfor DG set |
| 76 | Shut Down Valve |
| 77 | Hose fuel suctionsuitable for 62.5 KVA to 125KVA DG set. |
| 78 | Hose fuel suctionsuitable for 140 KVA to 500 KVA DG set. |
| 79 | Hose fuel Return suitable for 62.5 KVA to 125 KVA DG set. |
| 80 | Hose fuel Return suitable for 140 KVA to 500 KVA DG set. |
| 81 | HoseFuel, Water sperator to filter suitable for 100 KVA to 500 KVA DG set. |
| 82 | Hose Fuel,Filter to Fuel pump suitable for 100 KVA to 500 KVA DG set. |
| 83 | Dismantling and taking out the self starter,12 Volt DCfitted in10to 62.5 KVA 3 phase 50 HZof DG setsand strip opening of Self starter 12 Volt DC for carrying out repair/ servicing /overhauling mechanically ,cleaning, oiling/greasing/varnishing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, complete and re-assembling ofSelf starter 12 Volt DC after repair/ servicing /overhaulingand fixing the same in position and testing complete all as specified and directed.Notes :- (i)Repairs/servicing / reassembling and testing of Self starter 12 Volt DC shall be carried out through a authorised service center .(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall bemeasured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc.(iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre. |
| 84 | Supply only the following items/spare parts suitableforself starter, 12 Volt DCfitted in62.5 KVA3 phase 50 HZ of DG set , dismantled/fixed under Sch `A` item No 16 here in above complete all as specified and directed.Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A\" item No 17 here in above.(ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item. |
| 85 | Solenoid switch suitable for self starter, 12 Volt DC |
| 86 | Commutator suitable for self starter, 12 Volt DC |
| 87 | Carbon brush suitable for self starter, 12 Volt DC |
| 88 | Field coils suitable for self starter, 12 Volt DC |
| 89 | Bendix pinion assembly suitable for self starter, 12 Volt DC |
| 90 | Bushesuitable for self starter, 12 Volt DC |
| 91 | Dismantling and taking out the self starter, 24 Volt DCfitted in100to 500 KVA 3 phase 50 HZof DG setsand strip opening of Self starter 24 Volt DC for carrying out repair/ servicing /overhauling mechanically ,cleaning, oiling/greasing/varnishing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, complete and re-assembling ofSelf starter 24 Volt DC after repair/ servicing /overhaulingand fixing the same in position and testing complete all as specified and directed .Notes :- (i)Repairs/servicing / reassembling and testing of Self starter 24 Volt DC shall be carried out through a authorised service center .(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall bemeasured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre. |
| 92 | Supply only the following items/spare parts suitableforself starter, 24 Volt DCfitted in100KVA to285 KVA3 phase 50 HZ of DG set, dismantled/fixed under Sch `A` item No 19 here in above complete all as specified and directed.Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A\" item No 91 here in above.(ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item. |
| 93 | Solenoid switch suitable for self starter,24 Volt DC |
| 94 | Commutator suitable for self starter, 24 Volt DC |
| 95 | Carbon brush suitable for self starter, 24 Volt DC |
| 96 | Field coils suitable for self starter, 24 Volt DC |
| 97 | Bendix pinion assembly suitable for self starter, 24 Volt DC |
| 98 | Bushesuitable for self starter, 24 Volt DC |
| 99 | Disconnecting existing non functional armature ofself starter, 24 Volt DCfitted in100 to 500 KVA DG set , dismantling and strip opening of the armature ofself starter, 24 Volt DC, removing the old existing burnt windings, cleaning the slots & rewinding of the armature ofself starter, 24 Volt DC, including supply with existing gauge super enameled copper conductor , including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc as requiredat workshop and transportation to site & refixing on same position & testing complete all as specified and directed. |
| 100 | Supply , fixing and connecting in replacement of UNSV maintenance free battery of 12 Volt, 180 AH capacity with electrolyte fully charged batteryincluding interconnection, commissioning and testing complete all as specified & directed. |
| 101 | Disconnecting and taking out the exhaust system of DG set of any capacity between 100 KVA to 500 KVAand carrying out cleaning of choked, carbonized exhaust pipe including exhaust silencer , including soldering / welding of leakage of pipe.and assembling the complete exhaust assembly including replacement of exhaust manifold gasket side pieces, metallic flexible pipe,nut bolts, and testing for making it leak proof and fixing the same in position and testing the system complete all as specified and directed complete all as specified and directed. |
| 102 | M & L for Cleaning of MS fuel tank of DG sets of 100 to 300 ltr capacity by collecting the fuel in cleaned barrels and removing sludge deposited/accumulated inside the tank of and disposal of sludge at a distance not exceeding 100 metre and cleaning the tank with kerosene oil , replacement of fuel tank strainer and unserviceable fuel gauge with new PVC fuel level indicator fixed with clips to the tank and marking levels for every 10 litre by marking and numbering on the side of fuel tank with synthetic enameled paint and refilling the collected fuel after filtration complete all as specified and directed. |
| 103 | M & L for Cleaning of MS fuel tank of DG sets of 400 to 800 ltr capacity by collecting the fuel in cleaned barrels and removing sludge deposited/accumulated inside the tank of and disposal of sludge at a distance not exceeding 100 metre and cleaning the tank with kerosene oil , replacement of fuel tank strainer and unserviceable fuel gauge with new PVC fuel level indicator fixed with clips to the tank and marking levels for every 10 litre by marking and numbering on the side of fuel tank with synthetic enameled paint and refilling the collected fuel after filtration complete all as specified and directed. |
| 104 | Disconnecting and taking out old unserviceable belts of the DG set and supply and fixing newbelt suitable forfollowing capacity of DG set engine match the existing complete all as specified and directed. |
| 105 | Belt for Fan,self complete set suitable for DG Set 62.5 to 125 KVA |
| 106 | Belt for fan fuel pump,water pump & oil pump of completeset suitable for DG Set 160 to 250 KVA |
| 107 | Belt for fan fuel pump,water pump & oil pump of completeset suitable for DG Set 100 to 285 KVA |
| 108 | Belt for fan fuel pump,water pump & oil pump of completeset suitable for DG Set 500 KVA to 725 KVA |
| 109 | Material & labour for replacement of unserveceable interconnection wiring and its interlocking system in AMF electric control panel for DG setwith using and including PVC insulated and unsheathed stranded copper conductor cable, single core, minimum 1.5 Sqmm size or as required 1100 Volts grade cable for making functional controls of the DG set, auxiliary contactor, push buttons, indicator, amps meter, volt meter complete as required at site for functioning of DG set in auto and manual mode, checking AC/DC circuits and removing & replacement of defective / unserviceable parts with new parts,complete all as specified and directed .Notes:(i) The complete panel shall be checked and tested on full load after necessary repairs and replacement of unserviceable wiring. for its smooth functioning and proper interlocking including shutt down on high water tempreture and low Oil pressure.(ii)All control wires shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of copper lugs. the cost of same are deemed to include under these items.(iii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall bemeasured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc. |
| 110 | Supply only the following items/spare parts suitableforAMF pannel of DG set, dismantled/fixed under Sch `A` item No 109 here in above complete all as specified and directed.Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A\" item No 109 here in above.(ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item. |
| 111 | Electronic timer,on delay type, dual range, suitable of 220 Volts/ 24 Volts, 2NO+2NC, 50 Hz, AC supply/ DC supply , for0-60 seconds . |
| 112 | Power contactor 3 polewith 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC 3 rating 300/325/330 Amps. Complete all as specified and directed . |
| 113 | Power contactor 3 polewith 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC 3 rating 400 Amps. Complete all as specified and directed. |
| 114 | Power Contactor No volt coil suitable for 400Amp Contactor |
| 115 | Power Contactor No volt coil suitable for 300/325/330 Amp Contactor |
| 116 | Auxilliary relay 8 pin, 24 Volts ,DC , 2 change over. |
| 117 | Auxilliary relay 8 pin, 220 Volts , AC , 2 change over. |
| 118 | Bimetal under volt / over volt relay suitable for 3 phase, 3 wire with 2 NO+2NC auxiliary contacts |
| 119 | Engine starting relay with sequence timer & Master timer suitable for 12 / 24 Volts DC supply. |
| 120 | Selector switch 3 way for auto manual operation . |
| 121 | Selector switch 4 way for operation of volt meters & Ammeter. |
| 122 | Indicating lamps LEDtype with holderfor 12 / 24 volts DC supply |
| 123 | Digital electronic ammeter double ratio with 5 Amps secondary current of any range, flush pattern sequence type size 96mmX96mm suitable for existing CT ratiofor maintaining on 415 Volts built in selector switch |
| 124 | Digital electronic volt meter 0-50 V range suitable for 12 / 24 volt DC supply panel flush pattern square type size 96mmX96mm |
| 125 | Digital electronic volt meter 0-500 V range suitable for 415 Volts panel flush pattern square type size 96mmX96mm |
| 126 | Digital electronic Frequency meter 40-99.99 HZ buil in selector switch,suitable for 415 Volts panel flush pattern square type size 96mmX96mm |
| 127 | HRC fuse DIN type with basefor AC circuit 415 volts having rating of 400 Amps . |
| 128 | Disconnecting and taking outengine fitted in62.5 KVA to 500KVA 3 phase 50 Hz of DG set ( Make: Cummins/Caterpillar/Kirloskar/ Greaves) , dismantling andstrip opening ofcomplete engine of water cooled DG set of suitable capacity 3 phase 50 Hzfor carrying outrepair and complete over hauling , mechanically and electrically, cleaning,oiling/greasing , and fixing of serviceable parts in position, and removing& replacement of unserviceable/ defective parts /spares with new parts,as permanufacturer\"s instructions cleaning , oiling /greasing,descaling of water jackets,decarbonizing cylinder heads including refacing and lapping of valves, valve-seats, grinding of crank shaft or any other machining work required at site, allingment of connecting rods including matching with crank shaft. andreassembling the engine of DG set at position ensuring proper alignmentand coupling the engine with alternator, complete all as specified and directed. (including mentionedNote in here in below)Notes for Sch A item No. 128 here in above :(i)Repairs/Overhauling / reassembling and testing of engine of DG set shall be carried out through a authorised service center . (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall bemeasured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ here in after under item No.128 but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of loading, unloading & transportation to and fro authorized service centre and machining job etc.as required (iv) The element for connecting to existing system and making DG set perfectly operational and testing at site connected load to the entire satisfaction of the Engineer-in-Charge shall be included/covered under the rates quotedin Sch A item No.1 here in above consider for Maintenance and servicing. |
| 129 | Supply only the following items/spare parts suitableforDG set capacity 100 to 285KVA 3 phase 50 Hz of dismantled/fixed under Sch `A` item No 128here in above complete all as specified and directed.Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A\" item No 128here in above.(ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item. |
| 130 | Liner cylinder |
| 131 | Piston |
| 132 | Pin Piston |
| 133 | Ring Snap |
| 134 | Gasket cylider head (Front) |
| 135 | Gasket cylider head (Rear) |
| 136 | Gasket cylider head Cover |
| 137 | Valve Intake (ALTV) |
| 138 | Valve Exhaust (ALTV) |
| 139 | Guide Valve |
| 140 | Seal valve steam |
| 141 | Cotter valve |
| 142 | Bearing con rod |
| 143 | Bearing Main |
| 144 | Overhaulling Gasket Packing kit full |
| 145 | Disconnecting and taking out of defective battery charger and supply and fixing new automatic battery charger 12/24 volts suitable for charging of two batteries, including power transformer, Amp meter, Voltmeter alongwith selector switch and connected accessories fixed with and including sheet metal enclosure powder coated complete all as specified and directed. |
| 146 | Disconnectingand taking out thevoltage stabilizer offollowing capacity, any description and ofany make, dismantling / opening of the voltage stabilizer of following capacity, three phase, AC 415 Volts, forMaintenance and servicing mechanically and electrically,including draining out existing transformer oil, and cleaning, oiling /greasing,removing & replacement of defective / unserviceable parts with new parts, as required at site and manufacturer\"s instructions and checkingelectronic circuits to make it functional , reassembling the parts of voltage stabilizer after overhauling / servicing at position ensuring proper out putconnecting to existing system and applying one coat of synthetic enameled paint (heat resistant type) by spray machine after preparationincluding writing MES No/ SM No in capital letters of suitable size on body of stabilizerand making voltage stabilizer perfectly operational and testing at site on existing connected load to the entire satisfaction of the Engineer-in-Charge complete all as specified and directed. (including mentioned in Note here in below)Notes :-(i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch ‘A’ as supply only but fixing charges of the parts replaced/repaired is deemed to be included in these item.(ii) Oil shall be drained out and collected in contractors own containers and reuse after heating and filtration throughfiltration plant to achieve thesuitable dielectric strength/insulation value.Refilling, heating and filterationshall be included in the rate quoted by the contractor for above items. (iii) Fresh oil required for top up shall be measured as “supply only” but its heatingand filling shall be included in the rate quoted by the contractor for above items.(iv) The quoted rate shall be deemed to include replacement of small/ minor parts i.e. washers,nut bolts, packing, screws,lamp etc. |
| 147 | 15 KVA to 40 KVA capacity , |
| 148 | 75 KVA to 100 KVA capacity , |
| 149 | 150 KVA to 300KVAcapacity , |
| 150 | Supply and replacement of Rotary pump with suction pipe not less than 1 Mtr complete all as specified and directed. |
| 151 | Supply only the following items/spare parts suitablefor various capacity of Servo controlled Voltage Stabilizer dismantled/fixed under Sch `A` item No146 here in above complete all as specified and directed.Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A\" item No 146here in above.(ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item. |
| 152 | Servo motor 10 Kg-cm capacity. |
| 153 | Complete control wiring for each phase. |
| 154 | RC Net Work 10 Kg-cm (Resistor- Capacitor network) |
| 155 | Volt meter 0-300 volts, 72mm x 72 mm Square size, electromechanical type. |
| 156 | Electronic PCB Control Card (Sensing Card) |
| 157 | BTR- 36 |
| 158 | Indicator lamp pilot type (RYB) |
| 159 | Selector switches suitable for volt meter, 3 way ON/OFF type. |
| 160 | VARIAC Coil 40 KVA / 50 KVA capacity perPhase |
| 161 | Volt meter 0- 500 volts |
| 162 | Six Pin connector |
| 163 | Carbon brush suitable for 25KVA to 75 KVA stabilizer |
| 164 | Complete Armour |
| 165 | Terminal Stud |
| 166 | Micro Switch |
| 167 | Lever |
| 168 | VARIAC Coil 25 KVA/ 30 KVA capacity per phase |
| 169 | VARIAC Coil 75 KVA / 100 KVA capacity per phase |
| 170 | Transformer oil EHV confirming to IS-335 of 1983 of mineral oil grade \"B\" having a high dielectric strength not less than 40 KV . |
| 171 | Push button switch for increase/decrease of voltage |
| 172 | Chemical Earthing with copper pipe electrode 3.0 M long having outer pipe dia 50mm & inner pipe dia 44mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical compostion Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% buried in ground by digging a bore of 150mm dia surrounded by soil friendly backfill compound non soluble in water including connection with Copper earth strip 20x3mm upto 7 meter length, making PCC pit of size 0.3mx0.3mx0.3m (inner size) in mix 1:3:6 type CI with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting hook made out of 8mm dia bar and testing on completion to acheivevalue not more than 0.5 ohm complete all as specified and directed |
| 173 | M&L in replacementofeathing continuity conductor to wall on batten or buried in ground or drawn in conduit or fixed to pole or any other indicated situation for loop earthing etc, as required 20x3 mm dia copper strip, complete all as specified and directed |
| 174 | Supply, fixing, connecting and testing in replacemnt of UNSV turbo charger service kit suitable for following capacity of DG sets as per existing shape and size complete all as specified and directed. |
| 175 | 100 to 180 KVA 3 phase 50 HZ |
| 176 | 200 KVA to 500 KVA, 3 phase 50 HZ |
| 177 | Supply and replace of defective existing battery lead (Heavy duty) PVC insulated copper conductor single core multi stranded minimum 25 Sqmm one side fixed with clamp and other side fixed with brass battery terminal of heavy duty for 3 Mtr length (Set of two) |
| 178 | Supply,fixing and testing inrelacement of UNSV LT Switch Disconnector Changeover switch on load (without fuse link) complete with handle assembly having door interlock and padlocking arrangement,630Amps , size four Pole in open execution, Make of INDO ASIAN ICAE0630 equivelant in C&S / Legrand / Seimens . . |
| 179 | Labour only for daily basis complain for minor repair of engine ,AMF panel,alternator and its testing on installation complete, by employing one DG set mechanic on receving the complaint slip from MES Service Centre and returning the same after dully completing the job to MES Authority complete,all as specified and directed by Engr-in Charge |
| 180 | Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes etc.all as specified and directed by Engineer-in-Charge including removing cable protection covers/ bricks & stacking serviceable bricks for reuse and disposal of unserviceable covers within 50 m all as directed.Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection.(ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations |
| 181 | M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers of25 cm thickafter the cables etc. are laid, jointed and tested complete all as specified and directed. |
| 182 | M&L for Removal of surplus excavated soils not exceeding 50 Mtr distance and depositing where at a level not exceeding 1.5 m above the starting point complete all as specified. |
| 183 | Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed, |
| 184 | M&L for Un-reinforced precast concrete cable cover class LV type I, flat, size 250mm x 150mm x 40mm as proteciton to under ground cable laid dry flat adjoining each other complete all as specified and directed |
| 185 | Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / pole post etc, cutting and making necessaries arangement by means of wedling and jointing suitable for post of larntent/ street light fitting including PCC work complete all as specified and directed . Make of pipe TATA / Jindal / Swastik / Prakash / BSTor any other ISI marked make approved by GE.(Note : PCC work shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 186 | Disconnecting and taking out old existing unserviceable/ non- functional LT Cable and Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed. Make:Havells/GLOSTER/Polycab) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately ) |
| 187 | 10 Sqmm 2 core |
| 188 | 16 Sqmm 2 core |
| 189 | 16 Sqmm4 core |
| 190 | 25 Sqmm4 core |
| 191 | Labour only for checking the serviceability of the different spares / components / parts of security light fittings/post top lantern light fittings (LED,HPSV, Metal Halide, flood lightfittings etc, any wattage/capacity) of any description and fixed in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed here in after in notes. NOTES FOR SCH `A’ ITEM NO 191:-(i) Replacement of parts i.e Drivers,SPD, LED board,lamps, choke, Igniter, Condenser, Holder, covers etc for Street/Flood light fittings any wattage & capacity, if any required at site, shall be measured and paid for separately under appropriate item of Schedule `A\" as ‘supply only. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site.(iii)Required screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item.(iv)Contractor shall be paid only one time the labour charges quoted above in Schedule `A\" items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. (v) Contractor’s quoted rates for Schedule `A\" item No 191 is deemed to include for inspection/checking the serviceability of the fittings in position or by taking down as per site requirement, removing the damaged unserviceable / broken parts, fixing the new parts as required, fixing the fittings in same position or the other, connecting the fittings with electric source and testing of fittings as directed. |
| 192 | M&L for making holes in electric/street light poles of any height or in any shape, by means of drill machine and drawing of drawing of 1.5sqmm x3 core cable through the hole from junction box to the hole on the top of pole near the street light fitting complete with all electric connections complete all as specified and directed. (Rates of the cable deemed to be included) |
| 193 | Material & labourof PCC 1:3:6 type C-2 using 20 mm graded stone aggregate (4 stay). in mass concrete and filling completefor foundation/hard standing coping ,complete all as specified and directed. |
| 194 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling of poles and mass concrete etc complete all as specified and directed. |
| 195 | M & L for cutting chases in hard standing road/path/drain etc for passing cables/pipes etc. size of and removing the excavated materials and disposal at 50 metre distance and making good the cutting after the pipe and cables are laid with PCC 1:3:6 type C-1 using 20mm graded stone aggregates complete all as specified and directed. |
| 196 | Supplying,erecting and fixing in replacement of UNSV steel tubular swaged pole (410 SP – 31), 9 mtr long,in true vertical position complete conforming to IS : 2713 (Part-I & III) 1980 with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole finished with one coat of red oxide primer complete, all as specified and directed. (Note : Excavation and PCC work shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 197 | Supply, fixing & testing in replacement of UNSV15W LED street light with corbonate cover with high inpact resistance, 15 W-1500 lumens with efficacy of 100 lumans /wall at system level, ingress protection of IP65 PF-0.9 & with input resistanct i.e.IK 09 surge protectin upto 4KV,compiled withIS 10322 CCT is greater than 5000K,complete with all accessories duly prewired, supply and fixing the bracket of 40 mm dia 60 cm long GI pipe light grade bent to shap and including MS FI clamp of 20X3 mm nut and bolts and connected with flexible cable 3 core copper conductor 0.5 Sqmm upto ceiling rose complete mounting on existing MS frame bracket including connecting the fitting complete, all as specified and directed. Make-Crompton / Havells/C& S/Bajaj/ Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 198 | Supply, fixing & testing in replacement of UNSV45W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing MS framebracketincluding connecting the fittingcomplete all as specified and directed.Make-Crompton / Havells/C& S/Bajaj / Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 199 | Supply, fixing & testing in replacement of UNSV60W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing MS framebracketincluding connecting the fittingcomplete all as specified and directed.Make- Crompton / Havells/C& S/Bajaj). (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 200 | Supply, fixing & testing in replacement of UNSV90W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing MS framebracketincluding connecting the fittingcomplete all as specified and directed.Make- Crompton/Havells/C& S/Bajaj/ Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 201 | Supply, fixing & testing in replacement of UNSV120W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing MS framebracketincluding flexible cable 3 core copper conductor 0.5 Sqmm upto ceiling rose complete mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed.Make- Crompton /Havells /C& S/Bajaj/ Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 202 | Supply, fixing & testing in replacement of UNSV 120W LED Highmast light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing 16 mtrs High Mast/11 mtrs pole /9 mtrs poleor Bldg MS frame/bracketincluding connecting the fittingcomplete all as specified and directed. Make- Crompton/Havells/C& S/Bajaj/Shakti (Note : GI pipe bracket shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 203 | Supply, fixing & testing in replacement of UNSV 50W LED Flood light (Orange, White & Green) colour full IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing 16 mtrs High Mast/11 mtrs pole /9 mtrs poleor Bldg MS frame/bracketincluding connecting the fittingcomplete all as specified and directed. Make- Crompton/Havells/C& S/Bajaj/Shakti (Note : GI pipe bracket shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 204 | Supply, fixing & testing in replacement of UNSV LED Highmast LED IP 65 luminaire with high efficiacy light fittings 200 watts with all aecessaries complete on Pole and building wall/ ceiling comple (Make- Crompton /Havells /C& S/Bajaj). |