}

Tender For Annual Repair & Maintenance Of Sewerage Scheme To Left Out Area Chamba Town In Tehsil And Distt. Chamba Sh Systemic Operation Of Sewage Treatment Plant And System Up Gradation For Long Term Sustenance To Achieve Treated Effluent Quality Standar, chamba-Himachal Pradesh

Government Departments has published Tender For Annual Repair & Maintenance Of Sewerage Scheme To Left Out Area Chamba Town In Tehsil And Distt. Chamba Sh Systemic Operation Of Sewage Treatment Plant And System Up Gradation For Long Term Sustenance To Achieve Treated Effluent Quality Standar. Submission Date for this Tender is 28-01-2025. Sewerage Construction Tenders in chamba Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

47284503
Tender For Annual Repair & Maintenance Of Sewerage Scheme To Left Out Area Chamba Town In Tehsil And Distt. Chamba Sh Systemic Operation Of Sewage Treatment Plant And System Up Gradation For Long Term Sustenance To Achieve Treated Effluent Quality Standar
Open Tender
Indian
Himachal Pradesh
Chamba
28-01-2025

Tender Documents

Tender Details

Tender For annual repair & maintenance of Sewerage Scheme To Left Out Area Chamba Town In Tehsil And Distt. Chamba Sh Systemic Operation Of Sewage Treatment Plant And System Up Gradation For Long Term Sustenance To Achieve Treated Effluent Quality Standards For The Period Of 10 Years Of Stp Cap. 0.77 Mld At Barga-Ii - A/R and M/O Sewerage Scheme to left out area Chamba townin Tehsil and Distt. Chamba HP (SH Systematic operation of sewerage treatment plant and system upgradation for long term sustenance to achieve treated effluent quality standards for the period of 10 years of STP cap. 0.77 MLD at Barga) Sl. No. Item Description 1 To operate repair and maintain all civil works and electro-mechanical equipments relating to sewerage system of Chamba town which consist of sewerage treatment plant of 0.77 MLD capacity for the period of 10 years in all respect to the entire satisfaction of Engineer-in-Charge. Firm should do comply the stringent effluent standards laid down by HP State Pollution Control Board terms and conditions. 2 O & M Cost for Ist Year 3 O & M Cost for 2nd Year 4 O & M Cost for 3rd Year 5 O & M Cost for 4th Year 6 O & M Cost for 5th Year 7 O & M Cost for 6th Year 8 O & M Cost for 7th Year 9 O & M Cost for 8th Year 10 O & M Cost for 9th Year 11 O & M Cost for 10th Year 12 Supply and errection of Electro Mechanical Instruments for long term substance of treated effluent as per HPPCB for STP 0.77 MLD capacity with in all leads and lifts as per the direction of Engineer-in-Charge 13 Mechanical Screen 14 Electronic Flow Meter 15 Anoxic Mixers with suitable motor, SS shaft and blades to deliver 25 rpm for the required size, SS shaft and blades to deliver 25 rpm for the required size, Motor ABB/GEC 16 Air Blower, standard manufacturer curve for 0.5 kg/cm2 total pressure, 3 Nos twin lobe blowers with 50% stand by (2+1), select blower capacity as per duty condition, Everest/Usha 17 Bio Media, Size of bio media polyurethane rings (22mm dia 15 mm depth with fins inside)Min surface area 500 m2/m3, virgin PP Non-topix, kaldness/ Linpor/ OEPL/ MM Aqua/Cooldeck 18 Diffuser, Provide Fine bubble Tube Type diffuser of 90 mm outer dia, 1000 mm length, and silicon membrane or for other size as per standard manufacturer guidelines, Air flow rate of each tube diffuser = 0.33 m3/min (As per manufacturer data), Airfin 19 Sludge Recycle Pumps (Centrifugal) non clog centrifugal pumps of 15 m3/hr capacity for 12-20 m dynamic head. However actual pump combinations will be decided by characteristic curve supplied by the manufacturer which also ensures tripping period of each pump is not less than 5 minutes, KSB, Kirloskar, Mather & Platt, Jyot 20 TUBE SETTLER, 1 m height Chaveron shape tube, settler inclined at an angle of 55 degrees, With horizontal in 2 Units 5 x 3.90 m each, Chevron shape with minimum sheet Th. 2 mm, PVC / MM Aqua / Cooldeck 21 PUMP FOR RECYCLING OF FILTERATE, Provide pump set capable of delivering 1.50 m3/hour capacity with one as standby. However actual pump combinations will be decided by characteristic curve supplied by the manufacturer which also ensures tripping period of each pump is more than 5 minutes., Centrifugal Pumps Make: KSB, Kirloskar, Mather and Platt, Jyoti Electric Motor Kirlosakar, ABB, GEC, Crompton, NGEF, Jyoti 22 Sluice Valves and NRVs, Bends, 100mm, 150mm, 200mm,Kirloskar, IVC, KSB, Upadhya (Calcutta) Fouress 23 Disc filter for removal of suspended particles from secondary treated effluent 24 Sludge Dewatering machine (Make any approved/ Beta Machines/ Micro Transmission 25 Air Grid, MS/SS/CPV 26 Control panel, L and T Components 27 Cable, RR/Havells 28 Inter connecting piping and fittings, MS/SS/UPVC/CPVC 29 Installation, Testing and Commissioning

Key Value

Document Fees
INR 10000 /-
EMD
INR 519885.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail