Tender For Urgent Ei And Ac Repairing Works For Pvd Beltola Building------Electrical Repairing Works, Kolkata-West Bengal

Government Departments has published Tender For Urgent Ei And Ac Repairing Works For Pvd Beltola Building------Electrical Repairing Works. Submission Date for this Tender is 27-01-2025. Electrical Maintenance Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

47265673
Tender For Urgent Ei And Ac Repairing Works For Pvd Beltola Building------Electrical Repairing Works
Open Tender
Indian
West Bengal
Kolkata
27-01-2025

Tender Documents

Tender Details

Tender For Urgent EI and AC repairing works for PVD Beltola Building------Electrical repairing works- 1 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2 2+14 way Enclosure [Make: Crabtree Enclosure (DCDKSHODCW16) or equivalent model of Legrand/Siemens/L&T as approved by E.I.C] [D-9, D-10/13] 3 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand /Siemens/ Crabtree/L&T as approved by E.I.C) [D-6/7] 4 (c) 40 Amps FP MCB 5 (c) 40 Amps DP MCB 6 Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand /Siemens/ Crabtree/L&T as approved by E.I.C) [D-5/6] 7 (a) 100Amp FP Isolator 8 (b) 63Amp FP Isolator 9 (c) 40 Amp DP Isolator 10 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make: Legrand /Siemens/ Crabtree/L&T as approved by E.I.C) [D-6/7] 11 (a) 6-32 Amps SP MCB[D-6/7] 12 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment [D-9/11] 13 2 Way 14 4 Way 15 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit FR (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA as approved by E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. only PVC Rigid Conduit on ceiling and remaining portion concealed] [E-25/4] 16 a) Average run 8 mtr [E-25/4(c)] 17 Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch(Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA as approved by E.I.C) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. [E-24/3] 18 a) On Board [E-24/3(a)] 19 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene / PVC rigid pipe and by the prelaid GI fish wire and making necy. connection as required [E-9/1] 20 3 x 22/0.3 (1.5 sqmm) [ E-9/1(b)] 21 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ E-9/1(s)] 22 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [E-9/1(v)] 23 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [ E-9/1(y)] 24 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [ E-9/1(d1)] 25 Supplying and fixing PVC Rigid Conduit FR [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works [E-16/7] 26 20mm size [E-16/7(a)] 27 Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI U hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles [E-3/6] 28 19 mm dia 3 mm thick polythene pipe without earth continuity wire [E-3/6(a)] 29 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9] 30 1.5 sqmm 31 2.5sqmm[F-5/9(i)] 32 4 sqmm[F-5/9(ii)] 33 6 sqmm [F-5/9(iii)] 34 10 sq.mm[F-5/9(iv)] 35 Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-18/12] 36 Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. [E-17/1] 37 4 Module [E-17/1(a)] 38 Supply & Fixing 240 V 6 A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC) on existing GI Modular type switch board having top cover plate and making necessaryconnections as required. [E-17/3(a)] 39 Supply & Fixing 240 V 16 A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections asrequired [E-17/3(b)] 40 Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(a)] 41 Supply & Fixing 240 V, 6/16 A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(b)] 42 Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket with 6A Modular type switch of grey/brown/other colour as approved by the authority/E.I.C (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-18/9(a)] 43 Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/5(a)] 44 Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brandapproved by EIC) & necy. Connections. [E-17/5(b)] 45 Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire . As per direction by EIC.[C-3/21(a)] 46 Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire.. [C-3/21(b)] 47 Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flatincluding making good damages to building roof with satisfactoryfinishing and painting – (As per Drawing no. 475 of PWDSpecification Book – May 1991) incl all aceessories as required as per direction of EIC .[D-14/29] 48 Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. Making necy. connections etc. As per direction by EIC.[E-18/10] 49 Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & FMS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages andpainting [F-1/2(a)] 50 Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [F-1/2(b)] 51 Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [F-1/2(d)] 52 Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish [F-3/5] 53 Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc.[F-3/5(ii)] 54 Supplying and fixing double compression type gland and finishing the ends of following XLPE / PVC armoured AL. cable (2/4 / 3.5)Core as per GS.[F-4 & F-5] & direction by EIC. 55 3.5 Core 70 Sq. mm[ [F-4/7(d)] &[F-5/8(b)(xvii)]] 56 3.5 Core 50 Sq. mm[ [F-4/7(d)] &[F-5/8(b)(xvi)]] 57 3.5 Core 25 Sq. mm[ [F-4/7(d)] &[F-5/8(b)(xiv)]] 58 4 Core 16 Sq. mm[ [F-4/7(c)] &[F-5/8(b)(xii)]] 59 4 Core 6 Sq. mm[ [F-4/7(c)] &[F-5/8(b)(x)]] 60 Supply&FixingofperforatedGIcabletraywithperforationnot morethan 17.5%suspendedfromceilingincl.S&FGI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. [D-14/34(a)] 61 100x50x1.25mm (18SWG) With out angle iron support[D-14/34(a) (i)] 62 Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders& 25x25x3mm angle iron for supporting the cross member incl. S&FGI connector, 6mm dia MS suspender, bolts & nuts, steel fasteneretc. as required of the following size. Incl. Al painting of MS support.[D-15/34(b)] 63 100x50x1.25mm (18SWG) 64 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: [G-1/2] 65 By TATA-Medium GI pipe [G-1/2(a)] 66 Excavation of soil for installation of Earth Electrode and filling & ramming.[G-1/1]As per direction by EIC. 67 For Soft Soil[G-1/1(a) ] 68 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe . As per direction by EIC.[G-2/3(a)] 69 Extra for treatment of soil by using salt & charcoal or coke forplate electrode. As per direction by EIC. [G-2/3(b)] 70 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts,nuts, washers, spacing insulators etc. as required [G-2/4(c)] 71 Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages [G-2/5] 72 No. 6 SWGSolid GI wire [G-2/5(a)(ii)] 73 Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [G-3/5(d) ] 74 Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required -50 mm dia[F-6/11(d) ] 75 65 mm dia[F-6/11(e) ] 76 Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. Length, as per direction by EIC.[C-4/29 ] 77 Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long), As per direction by EIC.For Al -30 cm Exhaust fan (12)[D-14/32(a) ] 78 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 30 cm (12) [C-4/28(b) ] 79 Fixing only lamp , by checking the connection as per direcion by EIC. [C-2/11 ] 80 Fixing only pendent light fitting complete with lamp, shade and 24/0.2 mm (1.5 sqmm) flexible copper wire incl. S&F pendentholder, as per direction by EIC. [C-2/12 ] 81 Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length [C-2/17] 82 Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitablesize of MS fastener, As per direction by EIC.[C-2/14(b)] 83 Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [C-2/16] 84 S & F Timer Control unit for Compound Ltght with 12-way SPN DB Box(Mk.- L & T / Crabtree / Legrand/ Siemens/ABB)- 12 way SPN DB or Timer DB- 1 no40A DP MCB Isolator- 1 noDigital 24 hrs.Time switch-1 no 25 A 2 pole power contactor-1noCentre off 2-way toggle switch-1 no 32A Barrier type Terminal -1 noLED lndicating lamp-2 no2x4+1x2.5 Sq.mm Cu wire(Gloster /KEI/RR Kabel)All control circuit wiring would be made by 1x1.5 sqmmFRLS stranded Cu wire(Brand approved by E.I.C) and the I/C & O/G circuit with 4x6sqmm copper wire of suitable length maintaining colour code incl taping, socketing to complete the work, As per direction of EIC. 85 Supply and Fixing of Junction box (250x200x105 mm) with Front side opening door and Earth stud, locking arrangement with clamp (Mk- Syntex- GSJB2520 / equivalent ). Junction box having following accessories-2Way 32A Stud type power Terminal- 1 no(Mk.- Reputed) 6A SP MCB C-curve, 10KA (MK. - L & T/ Legrand/ ABB) - 1 noAs per direction by EIC. 86 Supply & fixing of Blank Plate for existing modular box (Mk - Legrand/ Crabtree/ Seimens) 87 Supply & fixing of automatic single phase AC starter of 25Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of LT/Legrand as per dierction of E.I.C) to be fixed on GI 4 module box with concealed in wall and mending good the damages including necessary connections as per direction by EIC. 88 Supply & delivery of4/3.5 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make - Gloster / KEI / Havells / RR Kable / Polycab / Mescab as approved by E.I.C] 89 4 Core 70 Sqmm 90 4 Core 10 Sqmm 91 2 Core 6 Sqmm 92 Supply & delivery of 1.1 KV grade XLPE- Multi core PVC insulated flexible copper Cable. (make: Gloster / Havells/KEI/Polycab/RR Kabel / Mescab as per approved by EIC) 93 3 core 1.5 sqmm 94 3 core 2.5 sqmm 95 Supply & delivery of230 V 1200 mm sweep Energy savings High-speed (1/2)-star Ceiling fan complete with required down rod, canopies, rigidly connected safety tie wire, copper winding, P2 Burst-proof capacitor and complete with all remaining accessories except regulator suitable for 230 V, 50 Hz, single phase AC power supply [Orient Quasar Ornamental /Crompton Aura Prime Antiidust / Havells as approved by E.I.C] . 96 Supply of Recessed Mounted square 2 ft x 2 ft LED light fitting with energy efficient diffuser having system lumen output not less than 3600 lumen, power input not more than 30 watt, Colour temparature(CCT) -6500K/5700K/4000K (as approved by E.I.C as per site requirement), Luminous efficiency - 120 luman/watt,CRI > 80, IP rating 20 (Make- Philips - RC380B LED36S - 6500 G6 L60W60 PSU OD S1 or equivalent model ofWipro - CRCO10R030HP57G3 as approved by E.I.C)incl. inter connection & necy. arrangement as per direction of EIC. 97 Supply and fixing of Recessed Mounted round LED light fitting with energy efficient diffuser having system lumen output not less than 1500 lumen, power input not more than 12 watt, Colour temparature(CCT) -6500K/5700K/4000K (as approved by E.I.C as per site requirement), Luminous efficiency - 120 luman/watt,CRI > 80, IP rating 20 (Make- Philips - DN296B LED15S 6500 PSU WH or equivalent model of Crompton /Wipro as approved by E.I.C)incl. inter connection & necy. fixing arrangement as per direction of EIC. 98 Supply & delivery of 230 V 10 watt IP65 LED bulk head light fitting (Make - Philips - WT202W LED10S NW PSU S3 PC or equivalent / Wipro) 5700 K / 6500 k (As approved by EIC)with die cast aluminium housing & frosted glass on wall/ceiling incl. S&D 10 watt LED lamp complete set. As per direction by EIC. 99 Supply & Delivery of BIS approved new generation energy saving, environment friendly and long lasting heat resistant, IP-66 & IK10 rated 15O watt (maximum) LED street light luminaries with pressure diecast aluminum housing and Toughened Glass/PC cover provided with high power LEDs and secondary optics PC/PMMA lens and Silicon filled BIS registered Potted Vibration proof Driver with builtin 4 KV surge protection and l0KV external SPD with EIficacy>135 lumen/watt, CRI >70, CCT > 5700K.Make:- Wipro,Voyage /Crompton, Falcon Pro I/ Bajaj Hexo J/ PHILIPS Urban edge Plus )Driver Mk.- Philips Signify /Wipro / Xtanium / Inventronics.LED Chip mk.-Nichia,Cree,Osram, Lumiled. as approved by E.I.C as per site requirement] 100 Fixing only outdoor / street light type fluorescent light fittingcomplete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting [C-3/19] 101 Supply and delivery of230 V 450 mm (18 inch) sweep 1420 rpm metal body wall bracket fan for wall/ceiling, including rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd., as per direction by EIC.(Make -EPC / Crompton 450mm ACVORTEX 18 WM as approved by E.I.C)incl. inter connection & necy. arrangement as per direction of EIC. 102 Supply & delivery of230 V 80 W 1420 RPM 12 (300 mm) sweep metal body Exhaust fan (Make-EPC Exhaust fan - 300 mm - 12 1420 rpm metal body) incl. inter connection & necy. arrangement as per direction of EIC. 103 Supply & delivery of Twin LED tube light fitting complete with all accessories [Philips make Cat No. TMC-502 2 x T-LED 22W or equivalent model of / Wipro as approved by E.I.C] incl. supply of 2No. 4 long 18W tube (Make -Philips, cat no.-MASLED tube 1200mm 18W 865 T81 - 2100lm or equivalent model ofWipro as approved by E.I.C) 104 Supply & delivery of Single LED tube light fitting complete with all accessories [Philips make Cat No. TMC-502 1 T-LED 22W or equivalent model of Wipro as approved by E.I.C] incl. supply of 1No. 4 long 18W tube (Make -Philips, cat no.- MASLED tube 1200mm 18W 865 T81 - 2100lm or equivalent model of / Wipro as approved by E.I.C) 105 Supply & fixing of Single LED tube light of 4 long 18W tube (Make -Philips, cat no.- MASLED tube 1200mm 18W 865 T81 - 2100lm or equivalent model ofWipro as approved by E.I.C) on existing fittings by checking the connection, as per direction by EIC. 106 Supply & fixing of Single LED tube light of 4 long 30W tube (Make -Philips, cat no.- MASLED tube 30W 4100lm865 T8or equivalent model of / Wipro as approved by E.I.C) on existing fittings by checking the connection, as per direction by EIC. 107 Supply of 9 watt LED Bulb (Make -Philips Eye Pro or equivalent model of Crompton / Wipro as approved by E.I.C), as per direction by EIC. 108 Disconnection & dismantling existing old Electrical installation, Switch-board, wiring,Electrical fitting/fixtures etc with owns tools & takles incl. mending good damages as per GS and clearing/removing from the site 109 Electrical Load Balancing & proper distribution of the existing electrical system at Ground to 3rd floor by expert technician with proper socketing & DB arrangements for equal distribution of load as per directed by EIC. 110 Fan repairing Works 111 Opening the fan body part by part for cleaning and refixing the same, as per direction by EIC. [C3 / 22] 112 Testing of following A.C. Ceilling/Pedestal fan motor set, & rewinding of burn out coils by suppling the coil as per sample incl. changing of mica Sheet, Minalex paper, loop wires, backing vernishing and measuring R.P.M. etc. as per direction by E.I.C.a) New type ceilling Fan(1200mm) 113 Wall bracket Fan (450 mm) 114 Supply & fixing of 2.5 mfd fan condensor with proper connection & testing, As per direction by EIC.Make: Tibcon 115 Dismantling the old defective bush bearing including cutting hole of the fan cover for fixing the fabricated M.S. block as per ball bearning size including finishing by Lathe Machine one side cover fan , As per direction by EIC.a) A.C. Ceiling Fan (1200 mm). 116 Supply & Fixing of condensor clamp for existing ceiling fan, As per direction by EIC. 117 S & F new shaft of AC Ceiling fan (1200 mm ) including polishing and refixing with finishing as per direction by EIC. 118 S & F ball bearring instead of bush bearring [Bearring size 6201 ( Male TATA )].as per direction by EIC. 119 Carrying for ball bearring charges of above defective ceiling Fans from site to workshop and back to site after ball bearing changing. 120 Painting of ceiling fan with one coat of primer and two coat of synthetic enamel paint by spray painting after cleaning and removing the old paint. as per direction by EIC.[C-3/25] 121 Engraving the deptt. number with 10 mm lettering on the body offan upto 10 letters incl. hifen, stroke or stop, as per direction by EIC. [C-3/24(a)] 122 Extra for additional one letter incl. hifen, stroke and stop, as per direction by EIC. [C-3/24(b)] 123 LT Panels Repairing & Servicing Works 124 Servicing of 400A MCCB incomming L.T. Cubilcle Panel with TPN SFU outgoing by the following - i. cleaning the panels part by part with checking the locking arrangements, ii. oiling the cams gears spring, iii. shaping the contacts (if required), iv. checking the insulation value by L.T. Measuring Kit, v. checking the socketing with taping arrangement,vi. tightening the terminal with greasing, vii. checking the busbar arrangements with proper insulation, viii. checking the connection of metering & switching arrangements,ix. testing the tripping & overall functioning the panels, as per site condition & directionEIC. 125 Cleaning the rust by emery paper & painting with double coat primer including RAIL paint of the 3 nos LT panels at Meter room and building panel room. Finishing the paint surface by expert panel painter with proper painting arrangements & tools, as per direction by EIC. 126 Supply & Fixing of LV ring type tape insulated class 1 Current Transformer (CT) at the existing position of LT cubicle panel with dismentling the existing damaged CT. Fixing the CT with proper connection & taping arrangements as per site condition.Make - Kappa /AE as approved by EIC. 127 250/5 A ,15 VA, Cl. - 1 128 . 400/5 A ,15 VA, Cl. - 1 129 Supply & Fixing of Ammeter / Voltmeter selector switch on the existing panel position including dismentling the damaged switch with necessary wire connection & finishing, as per direction by EIC.Make - Kaycee / L&T / AE 130 Supply & fixing of Indicating LED Lamp with colour glasses showing (Red/Yellow/Blue/Amber) on the existing panel position including dismentling the damaged light with necessary wire connection & finishing, as per direction by EIC.Make- Siemens / L&T / Schneider,or equivalent. 131 Supply & fixing of 415 Volts 63 Amps FN type TPN switch fuse unit (SFU) with 3 nos 63 Amps 80 KA cylindrical HRC fuse link (L&T HF 63 A - SF90159) , fixing on angle iron frame at existing panel position with dismentling the damaged unit, as perdirection of EIC. ( Make - L&T - FN 63 TPN / FP - SK95421) 132 Supply & fixing of analog Ammeter on the existing panel position with dismentling the damaged meter including the connection & testing, as per direction of EIC. 133 0 - 400 Amps range ( Make - AE 400/5A 1.5 Analog AC Ammeter) 134 Supply & fixing of analog Voltmeter on the existing panel position with dismentling the damaged meter including the connection & testing, as per direction of EIC. 135 0 - 500 Volts range ( Make - AE 500 V 1.5 Analog AC Voltmeter) 136 Supply & fixing of heat shrink PVC sleeves thickness of 2.5 mm to 3.5 mm & suitable for 50mm x 6mm Copper flat plate on existing panel, finishing the sleeves with proper tools & tackles, as per direction by EIC. 137 Supply & fixing of hylam sheet (7 by 7 ) PPI make, suitable for existing panel switch insulation, finishing with proper tools & tackels, as per direction by EIC. 138 Distribution wiring in 1.1KV grade single core 1.5 Sq.mm. stranded FRLSH PVC insulated & unsheathed single core stranded copper wire (Make - Polycab / RR Kabel / Finolex ) incl. necy.socketing & taping arrangements as required for existing L.T. panel Interconnection & wiring by expert technician, also dismentling the old existing damaged wiring & finishing with proper tightening, as per direction by EIC. 139 Supplay & Laying of 1.1KV grade single core 16 Sq.mm stranded FRLSH PVC insulated & unsheathed single core stranded copper wire (Make - Polycab / RR Kabel / Finolex ) incl. necy.socketing & taping arrangements as required for existing L.T. panel Interconnection & wiring by expert technician, also dismentling the old existing damaged wiring & finishing with proper tightening, as per direction by EIC. 140 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. As per direction by EIC.[F - 5/9] 141 16 Sq.mm [F - 5/9/v] 142 DG Set (100 KVA) repairing & Servicing Works 143 Service charges for Checkingof 1 nos. 100 KVA 430 VDG set (Koel Green) by expert Engineer of OEMas per direction of E.I.C. 144 Service & Changes by new one of SPIN ON FILTER FOR LUBRICATING OIL of DG Set, As per direction of E.I.C. 145 Service & Changes by new one of FUEL FILTER ELEMENT PRE. (Bosch Part number 1 457 431 003) of DG Set, As per direction of E.I.C. 146 Service & Changes by new one ofFUEL FILTER ELEMENT MICRO.(Bosch Part number 9 451 037 409) of DG Set, As per direction of E.I.C. 147 Service & Changes by new one ofKOEL CARE Genuine Coolant Premix of DG Set, 26 Ltr. Canof coolant oil, As per direction of E.I.C. 148 Service & Changes by new one ofKOEL CARE Premium Genuine Oil of DG Set,5 Liters CAN of premium oil, As per direction of E.I.C. 149 Service & Changes by new one ofKOEL CARE Premium Genuine Oil of DG Set, 20 Liters CAN of premium oil, As per direction of E.I.C. 150 Service & Changes by new one ofDISTILLED WATER of DG Set,(2 LTR BOTTLE ofDISTILLED WATER) , As per direction of E.I.C. 151 Service & Changes by new one ofTHREADED BUSH. of DG Set,As per direction of E.I.C. 152 Service & Changes by new one ofAIR CLEANER PRIMARY ELEMENT FOR 12K22TA ENGINE FLEET GAURD 14 of DG Set,As per direction of E.I.C. 153 Service & Changes by new one ofAIR CLEANER SAFETY ELEMENT FOR 12K22TA ENGINE FLEET GAURD 14 of DG Set,As per direction of E.I.C. 154 Supply & Fixing 250 KVA DGs (Koel Green Company) Exhaust Cylindrical Silencer pipe of 8ft long mild steel Industrial Grade with polished finishing, As per direction By EIC. 155 Supply & Fixing 250 KVA DGs (Koel Green Company) Exhaust Cylindrical Additional pipe of mild steel Industrial Grade with polished finishing for outcome the exhaust line to outside of the Sub-Station Building, As per direction By EIC. 156 Supply and Fixing of 12 Volt 150 AH Tubular Batteries for 100 KVA DG set, with necessary connection & wiring including fixing on existing base frame, as per direction by EIC. (Make - Exide INVAMASTER series) 157 Lightining Arrestor Works 158 S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered/ welded with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar ( 4:2:1), including thimble joints of 7/16 SWG wire and (25 x 6) mm GI strip with SS nuts, bolts & washers. 159 Supply & fixing of 25 mm x 6 mm thick GI (Hot Dip) flat / stripsfor Horizontal & Vertical run on wall / floor with GI shaddles as required including drilling holes, bolts, nuts, washers, etc./ and mending good the damages to buildingworks . (Page : G-3/Item-5d). 160 Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: (P:J-1/Item-4)i)Length upto 0.5 Mtr 161 Length above 0.5 Mtr 162 Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. (P : J-1/Item-7) 163 Supply & Fixing of Testing Joints by 25 mm x 6 mm thick GI (Hot Dip) strip 125 mm long on wall after making suitable arrangement to establish a clearance of 50mm from wall for making junction connection with vertical conductor and conductor from earth electrode complete with S & F GI bolts, nuts, check-nuts, spring washers etc. as required. (Rate arrived from G.S. Page :J-2/Item-13) 164 Earthing with 65 mm dia GI pipe (TATA-Medium) 3.0 Mts. long with welded 2 nos. half circle bracket made of GI strip (65 x 8) mm. with two holes on extended portion of the each strip of length min. 250 mm , and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Rate arrived from G.S. Page : G-1/Item-2d) 165 Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. (For morum soil)(Page : G-1/Item-1b) . 166 Supply, Laying & Fixing of 50mm x 6mm galvanized (Hot Dip) steel strip in underground trench for interconnection between the Earth Points by joining (As per item no 11). (Rate arrived from G.S. Page : K-3/Item -134 + G-1/Item-1a.) 167 Jointing for Horijontal & vertical run of GI strip through welded joint of (25 x 6) mm or (50 x 6) mm GI Strip to Lap joints/ T joints, etc. and painting the joints with 2 (two) coats of bituminous paint.

Key Value

Document Fees
Refer document
EMD
INR 19166.0 /-
Tender Value
INR 9.58 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail