Tender For 28039195 Gas Calorimeter Bop Upstr 28039195 0001 0001 300922907 CALORIMETER,GAS,IC,900KCAL/NM3,+/-1.0% Technical Details Name : Jitendra Chaursia Contact : Email : JITENDRA.CHAURASIA@AMNS.IN 1 NO CALORIMETER,GAS TYPE:ISOTHERMAL , RANGE:900 KCAL/NM3 , ACCURACY:+/- 1.0 % RESPONSE TIME:100 MS , OPERATING TEMPERATURE:60 °C SAMPLE GAS:BLAST FURNACE GAS , POWER SUPPLY:230 VAC PRESSURE RATING:0.04-0.12 BAR , MOUNTING:PANEL , IP RATING:IP55 OUTPUT SIGNAL:4-20 MA DC Item Details : * Annexure-1: Data Sheet of CV Analysers for BF gas: * GENERAL Tag Number - 17-CV-001 Service <(>&<)> Component - Measurement of Wobbe Index, CV for BF Gas Line No - BFG-2600-43-05-003 Schematic diagram No - H019-MND-GASN-GMS-U-PID-001 Area Classification - Zone - Hazardous - Zone:1, Gr: IIB * SAMPLE GAS COMPOSITION Component - CO2 CO H2 N2 O2 Max. dust conc. Units - Vol% Vol% Vol% Vol% Vol% mg/Nm3 Min. conc.- 20 20 3 Balance 1 <(><<)> 5 Max. conc.- 23 24 6 Balance 1 <(><<)> 5 Dust Level- <(><<)> 5 mg/Ncum * SAMPLE TAPPING POINT Sample Temp in Deg.C (Normal <(>&<)> Max) - Ambient Temp in Deg.C - 45/60 Deg.C - 45 Deg.C Samp. Pr.:(Nor./Max) - 1050±50 mmWC Water Vapor / Moisture - BF gas shall be 100% saturated Vent to / Return Pressure - Exhaust Gas to vent to atmosphrere above Man height Sample pressure - Positive Pipe diameter at tapping point - DN 2600 Sampling System location - Analyser room No. of tapping points - One * SAMPLE HANDLING SYSTEM Sampling system - non-redundant Sample probe head, tube assembly - Material - Vendors scope - SS316 Probe length required - --- - VTS Heat trace tube for sample gas transportation with all necessary accessories and JB’S - 1/2OD SS316 Sample tube length as per process requirement - Max sample tube length allowed - 50M - VTS Sample Gas Pump - ---- Quantity - One Make - Model - VTS - VTS Power Supply - Power Consumption - 230 VAC, 50 Hz - NON-UPS - VTS Sample Gas Cooler- ------ Quantity - ------ Make - Model - 230 VAC, 50 Hz - NON-UPS - VTS Power Supply - Power Consumption - 230 VAC, 50 Hz - NON-UPS - VTS Auto Drain Pump - ------ Make - Model - VTS - VTS * CALIBRATION GAS CYLINDERS Specifications - VTS Cylinder Capacity - VTS Quantity - VTS * GAS ANALYZERS Type of Analyzer - Measuring Principle - Online - Combustion calorimeter Location of analyzer - Inside room Power Supply - 230 VAC, 50 Hz (UPS) <(>&<)> 230 VAC, 50 Hz (NON-UPS) Power consumption, kVA - VTS Output Signals - Three analog (4-20 mA DC) outputs: Calorific lWbbid(&)Sifiit Page 2 of 3 ArcelorMittal Nippon Steel India Limited AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000127259 Date 13.01.2025 Submission Date 20.01.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Mr. Divyakumar Patel Contact Email DIVYAKUMAR.PATEL@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 2 28039195 0002 0002 300923083 CALORIMETER,GAS,IC,0-4250KCAL/NM3,CO Technical Details Name : Jitendra Chaursia Contact : Email : JITENDRA.CHAURASIA@AMNS.IN 1 NO CALORIMETER,GAS TYPE:ISOTHERMAL , RANGE:0-4250 KCAL/NM3 , ACCURACY:+/- 1.0 % RESPONSE TIME:100 MS , OPERATING TEMPERATURE:80 °C SAMPLE GAS:COKE OVEN GAS , POWER SUPPLY:230 VAC PRESSURE RATING:0.098-0.1471 BAR Item Details : * Annexure-2: Data Sheet of CV Analysers for CO gas: * GENERAL Tag Number - 17-CV-002 Service <(>&<)> Component - Measurement of Wobbe Index, CV for CO gas Line No - COG-1600-43-05-006 Schematic diagram No - H019-MND-GASN-GMS-U-PID-001 Area Classification - Zone - Hazardous - Zone:1, Gr: IIB Analyzer Type - Non-redundant * SAMPLE GAS COMPOSITION - Component - CO2 CnHn O2 CO H2 CH4 N2 Units - Vol% Vol% Vol% Vol% Vol% Vol% VOL% Min. conc.- 3 1.5 0.2 6 52 24 4 Max. conc.- 4 2.5 0.2 7 59 28 10 - NH3: 30mg/Ncum - BTX:28-35g/Ncum - H2S: 0.2g/Ncum - Tar:0.005g/Ncum - C10H8: 150mg/Ncum - HCN:1.3g/Ncum - Dust:5-10 mg/NM3 * SAMPLE TAPPING POINT Sample Temp in Deg.C (Normal <(>&<)> Max) - Ambient Temp in Deg.C - 45/80 Deg.C - 45 Deg.C Samp. Pr.:(Nor./Max)-Dust Level - 1300±50 mmWC - <(><<)> 5 mg/Ncum Water Vapor / Moisture - Vent to / Return Pressure - Exhaust Gas to vent to atmosphrere above Man height Sample pressure - Positive Pipe diameter at tapping point - DN 1600 Sampling System location - Open air No. of tapping points - One * PRIMARY SAMPLE HANDLING SYSTEM Automatic back purging of Sample Line till tapping point - Required Tar Seperator - Required High Impact Chamber - for heavies removal - Required * SECONDARY SAMPLE HANDLING SYSTEM Sampling system - non-redundant Sample probe head, tube assembly - Material - Vendors scope - VTS Probe length required - VTS Heat trace tube for sample gas transportation - 1/2OD SS316 Sample tube length as per process requirement - 50 m Max sample tube length allowed - VTS Sample Gas Pump - Quantity - One Make - Model - VTS - VTS Power Supply - Power Consumption - 230 VAC, 50 Hz-NON-UPS - VTS Sample Gas Cooler - Quantity - Make - Model - VTS - VTS Power Supply - Power Consumption - 230 VAC, 50 Hz-NON-UPS - VTS Naptha Seperator-Required - Naptha Seperator with 2 Levels of Filteration - VTS Auto Drain Pump - Make - Model - VTS * CALIBRATION GAS CYLINDERS Specifications - VTS Cylinder Capacity - VTS Quantity - VTS * GAS ANALYZERS Type of Analyzer-Measuring Principle - Online - Combustion calorimeter Location of analyzer - Inside room Power Supply - 230 VAC, 50 Hz (UPS) <(>&<)> 230 VAC, 50 Hz Page 3 of 3 ArcelorMittal Nippon Steel India Limited AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000127259 Date 13.01.2025 Submission Date 20.01.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Mr. Divyakumar Patel Contact Email DIVYAKUMAR.PATEL@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 3 28039195 0003 0003 300923010 CALORIMETER,GAS,IC,0-1750KCAL/NM3,LD Technical Details Name : Jitendra Chaursia Contact : Email : JITENDRA.CHAURASIA@AMNS.IN 7 NO CALORIMETER,GAS TYPE:ISOTHERMAL , RANGE:0-1750 KCAL/NM3 , ACCURACY:+/- 1.0 % RESPONSE TIME:100 MS , OPERATING TEMPERATURE:40-60 °C SAMPLE GAS:LD GAS , POWER SUPPLY:230 VAC PRESSURE RATING:0.13-0.14 BAR , MOUNTING:PANEL Item Details : * Annexure-3: Data Sheet of CV Analysers for LD gas: * GENERAL Tag Number - 17-CV-003 Service <(>&<)> Component - Measurement of Wobbe Index, CV for LD gas Line No - LDG-1800-43-05-001 Schematic diagram No - H019-MND-GASN-GMS-U-PID-001 Area Classification - Zone - Hazardous - Zone:1, Gr: IIB Analyzer Type - Non-redundant * SAMPLE GAS COMPOSITION Component - CO CO2 N2 H2 Units - Vol% Vol% Vol% Vol% Min. conc. - 50 13 Balance - Max. conc. - 70 15 Balance - Dust Level - * SAMPLE TAPPING POINT Sample Temp in Deg.C (Normal <(>&<)> Max) - Ambient Temp in Deg.C - 45/60 Deg.C - 45 Deg.C Samp. Pr.:(Nor./Max) - 1400±50 mmWC Water Vapor / Moisture - Vent to / Return Pressure - Exhaust Gas to vent to atmosphrere above Man height Sample pressure - Positive Pipe diameter at tapping point - DN 1800 Sampling System location - Analyser room No. of tapping points - One * SAMPLING SYSTEM Sampling system - non-redundant Sample probe head, tube assembly - Material - Vendors scope - SS316 Probe length required - VTS Heat trace tube for sample gas transportation - 1/2OD SS316 Sample tube length as per process requirement - 50 m Max sample tube length allowed - VTS Sample Gas Pump - One Quantity - One Make - Model - VTS - VTS Power Supply - Power Consumption - 230 VAC, 50 Hz-NON-UPS - VTS Sample Gas Cooler - Quantity - Make - Model - VTS - VTS Power Supply - Power Consumption - 230 VAC, 50 Hz-NON-UPS - VTS Auto Drain Pump - Make - Model - VTS - VTS * CALIBRATION GAS CYLINDERS Specifications - VTS Cylinder Capacity - VTS Quantity - VTS * GAS ANALYZERS Type of Analyzer-Measuring Principle - Online - Combustion calorimeter Location of analyzer - Inside room Power Supply - 230 VAC, 50 Hz (UPS) <(>&<)> Power consumption, kVA - VTS Output Signals - Three analog (4-20 mA DC) outputs: Calorific value, Wobe index <(>&<)> Specific gravity. Alarm Relays - Two alarm relay outputs (High and Low Calorific value, set points adjustable at Site) Data communication <(>&<)> Diagnostics - Over Profinet Accuracy - +/- 1.0% F.S. CV or Wobbe Index Linearity - -2% Repeatability - +/- 0.5%