}

Tender For Balance Construction Work Of Drinking Water Facility At Mataundh Govt. Inter College At Dist. Banda (U.P.) - 1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding , banda-Uttar Pradesh

Uttar Pradesh Projects Corporation Limited has published Tender For Balance Construction Work Of Drinking Water Facility At Mataundh Govt. Inter College At Dist. Banda (U.P.) - 1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding . Submission Date for this Tender is 20-01-2025. Water Supply Project Tenders in banda Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

47226501
Tender For Balance Construction Work Of Drinking Water Facility At Mataundh Govt. Inter College At Dist. Banda (U.P.) - 1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding
Open Tender
NCB
Uttar Pradesh
Banda
20-01-2025

Tender Details

Tender For Balance Construction Work Of Drinking Water Facility At Mataundh Govt. Inter College At Dist. Banda (U.P.) - 1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 2 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 3 Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors. 4 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 5 Reinforced cement concrete work for Slab. (Using 1:1.5:3 Mix concrete) 6 Reinforced cement concrete work for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) 7 As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) 8 Reinforced cement concrete workfor thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) 9 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 10 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)UPTO P.L 11 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)ABOVE P.L 12 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) in foundation 13 First class brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc reqiored for proper completion of the work. 14 Painting with two coats of air blown bitumen 85/50 or 85/25 @ 1.7kg/sqm approxincluding cost of fuel if any. 15 Same as in item no. 10 abovebutin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. 16 Same as in item no.10 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 17 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for completion ofwork and including supply of steel its wastage bend hooks & authorised over lapping shall be measured upto floor two level. 18 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) 19 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand 20 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand 21 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). 22 Making of drain along with apron. 23 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 24 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 25 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth. 26 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth including cost of material, labour, T & P etc. complete. 27 Boring with 1.5 H.P Submersible Pump Set, 28 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 150mm dia 29 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (I) 110 mm nominal size dia 30 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (I) 110 mm nominal size dia. 31 Supplying, filling, spreading & leveling p gravel of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. 32 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 33 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of :110 mm dia 34 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 110 mm clamp. 35 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 110 mm dia. 36 PUMPING SET KSB make submersible pump set suitable for installation in bore well of min 110 mm inner dia preferably more and having under noted specifications.[1.5 H.P.} 37 Supply and fixing of finolex of copper cable ISI marked submersible cable of size 4 sq mm 38 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore 39 PLUMBING WORKS 40 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 42 110mm diameter 43 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 44 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 45 110mm 46 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 47 Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. 48 (internal work) 49 Exposed on wall 50 25mm dia nominal bore 51 Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 52 25mm dia nominal bore. 53 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 54 internal work -Exposed on wall 55 20mm dia nominal outer dia pipes 56 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. 57 Concealed work including cutting chases and making good the walls etc. 58 15mm dia nominal outer dia pipes 59 20mm dia nominal outer dia pipes 60 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 61 15mm nominal bore 62 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 63 15mm nominal bore 64 Providing and fixing of AQUA D PURE Commercial Water Purifier(RO+UV+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc. 65 Providing and fixing of Water Cooler 60LPH (Blue star Make) including all its accessories, complete in all respect including testing etc. 66 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 67 15mm nominal bore 68 Providing and fixing gun metal gate valve with wheel of approved quality. 69 25mm dia nominal bore 70 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 71 25 mm nominal bore 72 Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 73 Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 74 150 x 100 mm. size P type 75 With Sewer bricks conforming to IS : 4885 76 Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 77 90 mm O.D. 78 Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. 79 Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. 80 Size 90 mm 81 SUBHEAD I- WIRINGPOINTS 82 Wiring points for light with 1.5 sqmm.FRLSH PVC insulated single core Copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects. 83 Same as item No.(1) but for5amp plug point with piano type switch and socket etc. 84 Addition for light / fan points with modular type switchin place of piono type switch. 85 Addition for plugpointswith modular type switchin place of piono type switch. 86 Supply & wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FR PVC insulated 1100 V grade single core multistrand copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit complete, including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C. 87 Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 88 Supplyfixingand concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work( forTelephone) 89 Supply & fixing of LED Bulb with Holder 90 Supply and fixing of 6Amp to 32 Amp (10 KA)SP MCB in existing MCB, DB complete with connections as required. (CAT: A) 91 Supply and fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. 92 Supply and wiring of 4 core Armoured cable 10 Sqmm . FRLSH PVC insulated 1100 V grade Alluminium cable 93 GST extra as per applicable

Key Value

Document Fees
INR 5900 /-
EMD
INR 7000.0 /-
Tender Value
INR 3.48 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail