| 1 | Taking down carefully existing aluminium/copper point wiringfor (light, fan,bell,socket)complete with fittings such as Switches, sockets, ceiling roses, holders,bells & making goodthe disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed.Note : Rate for making good shall be deemed to be included in above item rate. |
| 2 | M&L Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through concealedin wall / roof/ceiling surface with cutting chases with concealed conduit with new provision of 1.6mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 2.8mm thick plastic laminate Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primerincluding continuous earth wire of size 1.5 Sqmm PVCstranded copper conductor unsheathed, insulated, stranded (Green colour) connected to common earthpoint dolly for forone light point/fan / bell point controlled by one way switch complete all as specified and directed . |
| 3 | All as per Srl item No. 02 here-in-before but for one three pin socket outlet 5 Amp on the same board with other switches complete all as specified and directed |
| 4 | All as per Srl item No. 02 here-in-before but for one switch socket outlet combination, 3 Pin 5 Amps, 230 Volts on independent board complete all as specified and directed |
| 5 | All as per Srl item No. 02 here-in-before for switch socket outlet 3 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5 Sqmm FRLS PVC unsheathed copper conductor and FRLS cable 2.5 Sqmm PVC insulated earth wire on independent board.complete all as specified and directed . |
| 6 | M&L Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through existingconcealed / surface conduit in wall / roof/ceiling surface with new provision of 1.6mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 2.8mm thick plastic laminate Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primerincluding continuous earth wire of size 1.5 Sqmm PVCstranded copper conductor unsheathed, insulated, stranded (Green colour) connected to common earthpoint dolly for forone light point/fan point/bell pointcontrolled by one way switch complete all as specified and directed . |
| 7 | All as per Srl item No. 06 here-in-before but for one three pin socket outlet 5 Amp on the same board with other switches complete all as specified and directed |
| 8 | All as per Srl item No. 06 here-in-before but for one switch socket outlet combination, 3 Pin 5 Amps, 230 Volts on independent board complete all as specified and directed |
| 9 | All as per Srl item No. 06 here-in-before for switch socket outlet 3 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5 Sqmm FRLS PVC unsheathed copper conductor and FRLS cable 2.5 Sqmm PVC insulated earth wire on independent board.complete all as specified and directed . |
| 10 | S&F switch piano, flush type, single pole, one way, 5/6 Amps, 230 volts, AC supply complete all as specified & directed |
| 11 | S&F socketone 3 Pin 5 Amps230 volt AC supply andincluding taking down old unservicable item complete all as specified and directed. |
| 12 | S&F piano type switch single pole 1 way 15/16 amps 230 volt AC supply andincluding taking down old unservicable itemcomplete all as specified and directed. |
| 13 | S&F socket 15/16 Amps230 volt AC supply andincluding taking down old unservicable itemcomplete all as specified and directed. |
| 14 | Supply and laying in replacement Submain wiring with two runs of single core PVC FRLS sheathed, insulated, copper cable of 6 Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 6 Sqmm for continous earth wire drawn into existing concealed PVC conduitcomplete all as specifiedand directed . Note :- Two runs of 6 Sqmm copper cable and one run of 6 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length) |
| 15 | Taking down and refixing of MCBs/MCCBswith necessary connections in DBs complete all as specified and directed . |
| 16 | S&F in replacement PVC non metallic rigid conduit, 20 mm external dia (medium grade) equivalent casing-capping exclusive of boxes but inclusive of all tees, bends, reducer, bell mouth tube ends and fixing accessories onin wall, floor and making good all disturbed surfaces matching with existing surfacescomplete all as specified and directed. |
| 17 | M&L for checking/inspection of non functional/non working geyser any capacity/make in existing location for identifying the defects/faults in geyser/wiring etc all as per complaint obtained from MES service center complete all as specified and directed. |
| 18 | M&L in replacement factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN DB) double door (IP-42 protection) fabricated from minimum 1.2 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates including one MCCB 100 Amp 4 pole 415V as incommer and 8 nos outgoing MCBs 230V as rating required at site including flexible pipe complete all as specified and conforming to IS: 8623 including making good disturbed surface complete all as specified and directed. Note:- All MCBs/MCCB and cable terminating into MCBs/MCCB shall be connected by using suitable copper lugs/thimble/sleeves and its cost shall be deemed to be included under this item. |
| 19 | M&L in replacement repair of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.2 mm thick CRCA sheet with metal double door (IP-42 protection ) fixed flush to wall and suitable for universal mounting and including 100 Amps bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with one MCB SPN 40 Amp as incomer and outgoings 6 Nos MCB as rating required at site incl flexible pipe complete all as specified and conforming to IS: 8623 including making good disturbed surface all as specified and directed.NOTE : All MCBs and cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under this item. |
| 20 | S&F in replacement PVC non metallic rigid conduit, 25 mm external dia (medium grade) ISI marked exclusive of boxes but inclusive of all tees, bends, reducer, bell mouth tube ends and fixing accessories on concealed including cutting chases in wall, floor and making good all disturbed surfaces matching with existing surfacescomplete all as specified and directed. |
| 21 | M&L in replacement MS sunken box 1.6 mm thick galvanised steel pressed sunken terminal boxesas per existing size, painted on both sides inside and outside with one coat of red oxide primer of suitable sizes for mounting of switches sockets, fan regulatorsetc. with 3mm thick plastic laminated sheet covers per existing size andincluding taking down old unservicable items, making good to the disturbed surfaces of walls, matching the colour with existing surfacecomplete all as specified & directed. |
| 22 | M&L for providing earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried dirictly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0 sqmm size upto 7.5 meter long by means of bolts,nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.5 of SSR Part-1 and connected to equipment including necessary excavation/ earth work in any type of soil/rock strata,funnel with wire mesh and 20mm dia pipe for protection of earth wire PCC pit with 40mm thick PCC cover etc. complete all as specified and directed. |
| 23 | M&L for providing earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried dirictly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth strip 25x4mm size upto 7.5 meter long by means of bolts,nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.5 of SSR Part-1 and connected to equipment including necessary excavation/ earth work in any type of soil/rock strata,funnel with wire mesh and 20mm dia pipe for protection of earth wire PCC pit with 40mm thick PCC cover etc. complete all as specified and directed. |
| 24 | M&L in repair of aluminium strip 25mm x 3.15 mm complete with new porceline insulator by means of screws of suitable size for isolation of strip complete all as specified and directed. |
| 25 | M&L in repair of test point terminal block made of GI Sheet box of size 90x90x90mm made of 1.6mm plain sheet and screwed to wall for protection of test point complete all as specified and directed. |
| 26 | M&L in repair of single pointed aluminium rod 12 mm dia and 300 mm long fixed on the roof including all fittings, fixtures and PCC 1:2:4 type B-1 blocks 100mm x 100mm x 100mm complete all as specified and directed. |
| 27 | M&L in repair of galvanized iron strip 25x4 mm buried in ground 150 mm below ground including all excavation and earth work connecting at ends, jointing etc complete all as specified and directed. |
| 28 | M& L for demantaling old existing broken earth pit chamber and prepare new chamber as per SSR norms complete all as specified and directed. |
| 29 | M&L for piling angle iron structure of height 0.5 m from ground level with PVC/mettalic sheet of size 50X50X5mm having printed the format of Earthing details such as location, date of measurment, resistance in Ohms, next due date and other details near earthings pit complete with PCC work complete all as specified and directed. |
| 30 | Taking out old earth continuity conductor with air termination rod from wall /roof/ground and refixing the same after cleaning with new porceline insulator by means of new screws of suitable size for isolation of strip complete all as specified and directed. |
| 31 | Labour for cutting grass/herbs near installaion complete including cleaning the area near earthing pits complete all as directed. |
| 32 | M&L PCC earthing chamber cover for earthing Pit of size 400x400x35mm complete all as specified and directed. |
| 33 | Material & Lobour for checking of earthings resistance of exixting earthing pit near lighting arrestors,panels,DBs, DG sets,pump houses, transformers/any other place by disconnecting the earthing strip from terminal/junction and maintening the register duly signed by user,contractor and concerned JE E/M including writing the result on nearby wall/sheet where ever possible using black paint for background and yellow/white colour for alphabet complete all as specified and directed. Note:-The Contractor to provide one electrician and one helper along with earth tester and accessories.The rates for the same are deemed to be included in the quoted rates of the contractor. |
| 34 | Supply and laying in replacement 2.5 sqmm 4 core PVC FRLS sheathed, insulated, copper cable multi stranded, 1100 volts grade complete all as specified and directed. |
| 35 | M & L for Cutting chases in bricks wall /PCC walls for taking out blocked concealed conduitedand making goodto surface in cement mortar 1:3 and with finish to match the existing surface complete all as specified and directed. |
| 36 | Laying only In Repair for sub main wiring as 1 x single core PVC FRLS insulated copper multistranded 1.5/2.5/4.0/6.0 sqmm in existing rigid PVC conduit including connection with electrical appliances complete all as specified and directed. |
| 37 | Fixing only switch/socket/fan regulator/ fan regulator at site all as specified and directed. |
| 38 | Fixing only in repair of LED tube light fiting 20W/ 10W (4f/2ft long) 230 V, surface/ wall mounted LED batten with polycarbonate housing & integrated electronic driver and including connections up with copper conductor wire at site complete all as specified and directed. |
| 39 | Fixing only in repair different types of MCBs 230V at site complete all as specified and directed. |
| 40 | Fixing only in repair geyser heating element 1500 watt suitable for any type, size & make of geyser as per existing complete all as specified and directed. |
| 41 | Fixing only thermostat of geyser suitable for any type, size & make of geyser as per existing range temperature complete all as specified and directed.. |
| 42 | Fixing only hot water PVC connection of 15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both ends complete all as specified and directed. |
| 43 | Fixing only geyser with new anchor fastener for hanging the geyser on wall and making good the distributed surface completeall as specified and directed. |
| 44 | Fixing only exhaust fan with cutting hole of suitable size and making good the distributed surface completeall as specified and directed. Note :-The complaint are required to be attended/rectified on the same day of the reporting. However in exceptional case, if any complaint could not be attended on the same day. The same will be cleared within 48 hours of the reporting. |