Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-02-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 12-02-2025 |
| 2 | 24-01-2025 | CORRIGENDUM NO 01 | BOQ | 05-02-2025 |
| Sl. No. | Item Description |
| 1 | Material and labour for taking down ceiling fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismentaling of blades and deposited to store for repair all as specified and directed. |
| 2 | Supply and fixing in repair fan condencer 2.5/ 4MFD, 240 volts suitable capacity for ceiling/ exhaust Fanall as specified and directed. |
| 3 | Supply and fixing in repair ball bearing of suitable size and capacity for ceiling/ Exhaust fan all as specified and directed. |
| 4 | Supply and fixing in repair hanging assymbly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed. |
| 5 | Material and labour for painting of ceiling fanusing synthetic enamel paint in two coat over one coat of primer of any make/sweep/model etcafter cleaning/washing and fill up cavities using fillerincluding writing MES NO Black Colour complete all as specified and directed. |
| 6 | Material and labour for hanging only ceiling fan any type/sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades all as specified and directed. |
| 7 | Material and labour for rewinding of ceiling fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 1200/ 1400 mm sweep complete all as specified and directed.NOTE for item No 1 to 7 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate.(ii) The cost of shifting the fan from MES store yard to contractors workshop andback shall be included in the item.(iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair,in failing so, the amount @ Rs. 20/- per fan per day shall be deductedfrom the contractor due till the returning of fan duly tested. |
| 8 | Material and labour for taking down Exhaust fan / wall mounted fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismentaling of blades and deposited to store for repair all as specified and directed. |
| 9 | Material and labour for rewinding of Exhaust fan/wall fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 230 to 450 mm sweep complete all as specified and directed.NOTE for item No 2,3 and 8 to 12: -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate.(ii) The cost of shifting the fan from MES store yard to contractors workshop andback shall be included in the item.(iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair,in failing so, the amount @ Rs. 20/- per fan per day shall be deductedfrom the contractor due till the returning of fan duly tested. |
| 10 | Supply and fixing in repair metal fan blade including fixing mountings and accessories of exhaust fan of 230 to 450 mm sweep complete all as specified and directed. |
| 11 | Material and labour for fixing only exhaust fan any type/sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades, louvers etc all as specified and directed. |
| 12 | Supply and fixing of plastic body exhaust fan, AC singal phase,240 volts of size 250 mm sweep with heavy duty, plastic body with louvers connecting up including provision of fixing clamp, nut bolts and cable from ceiling rose or connector to fan,including taking down old unserviceable pastic body exhaust fan complete all as specified and directed. |
| 13 | Supply and fixing of wall mounting fan,AC single phase,240 Volts of size 400 mm sweep,1400 rpm ,copper wound complete all as specified and directed. |
| 14 | Taking down old unserviceable geyser of cap 25 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse inciuding all necessary minor repairs /servicing etcand checking serviceability of parts, necessary cleaning, soldering / welding works as required & reassembling the geyser, making necessaryadjustment and refixing the repaired geyser in position, connecting to existing electric & water connectionsand testing at site complete all as specified and directed. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate.(b) Examine any water leakage from geyser/storage tank.(c) Carry out operation of all stop cocks, pressure reducing valves,etc. to ensure free movement of the working parts.(d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items.(g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item of BOQ. |
| 15 | Taking down old unserviceable geyser of cap 50 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse including all necessary minor repairs /servicing etcand checking serviceability of parts, necessary cleaning, soldering / welding works as required & reassembling the geyser, making necessaryadjustment and refixing the repaired geyser in position, connecting to existing electric & water connectionsand testing at site complete all as specified and directed. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate.(b) Examine any water leakage from geyser/storage tank.(c) Carry out operation of all stop cocks, pressure reducing valves,etc. to ensure free movement of the working parts.(d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items.(g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item of BOQ. |
| 16 | Supply only heating element of capacity 2 KW of geysers of any make ISI marked complete all as specified and directed. |
| 17 | Supply only apparatus plate assembly with rubber gasket including nuts, bolts, washers for geysers of 50/35/25 ltrs capacity complete all as specified and directed. |
| 18 | Supply only thermostat ISI marked suitable for the Geysers 25 ltrs capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample complete all as specified and directed. |
| 19 | Supply only thermostat ISI marked suitable for the Geysers 50 ltrs capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample complete all as specified and directed. |
| 20 | Supply only temperature resistent SS braided pipe suitable to sustaine pressure up to 8 bar90 Cm long suitable forout going / Hot water connections of Geyser with washer etc. complete as an directed. |
| 21 | Supply only Non-return valve 15mm / 20mm dia of brass ISI marked as per requirement complete all as specified and directed. |
| 22 | Supply onlyIndicators of Geysers of any capacity/type (Red & Green) as per requirement complete all as specified and directed. |
| 23 | Supply only Geyser storage inner tank made out ofstainless steel sheet suitable for 25 ltrs capacitycomplete all as specified and directed. |
| 24 | Supply only geyser storage inner tank made outof stainless steel sheet suitable for 50 ltrs capacity complete all as specified and directed. |
| 25 | Supply only nut and long bolt set fastener made of steel, length not less than 6 cm as per site requirement for fixing of geysers complete all as specified and directed. |
| 26 | Supply only safety valve plug made out brass metal with fusible lead, inner thread type suitable for geyser of any type/capacity complete all as specified and directed. |
| 27 | Supply and fixing in repair copper cable PVC insulated and PVC sheathed flexible size 2.5Sqmm 3 core complete all as specified and directed.(Cable shallbe in suitable length as per site requirement). |
| 28 | Supply only heating element of capacity 1.5 KW of geysers of any make ISI marked complete all as specified and directed. |
| 29 | Supply onlymetal clad plug top 3 pin 20 Amp 230 Volts round shape suitable for AC box complete all as specified and directed. |
| 30 | Material and labourfor attending day to day complaints of E/M nature by means of checking unserviceable Electrical fitting and fixture and emergent fault rectification in elctrical circuit inclno light , earth leakage, short cicuit, neutral breakmains /sub mains/internal circuits of existing system of main building / block ,making continious electric supply including carrying out minor repairs etc as required to make system in order / functional by replacing, copper cable , copper thimbles, glands, earthing wire complete all as specified and as directed as required at site by Engineer-in-Charge. NOTE : - (a) Items reqd for replacement such as switchs, sockets for power/light/ fan/ bell/geyser points including complete will be measured and paid under respective items of BoQ. (b) Contractor rep/supervisor will report to MES Service Centrealongwith qualified/Experianced electrician and helper to collect dockets between 0900 hrs to 1000 hrs on all working daysfor rectification of complaints and resubmit the dockets after completion of each job of each jobon the same day.If contractor is failed to submit the docket within 48 hoursafter issuing of dockets , the contractor i liable to pay the penalty i.e. 20.00per docket per day till the re-submission of docket.(c) Contractor will attend emergent nature of work i.e. no light, short circuit after working hours/holiday as when ordered. The rate of the is deemed to be included in above quoted rates. |
| 31 | Supply only switch piano 5 Amps, flush type, single pole, one way,230 volt, AC supply, ISI Marked, complete all as specified and as directed. |
| 32 | Supply onlyswitch, single pole two way 6 Amps, 230 volts AC circuit complete all as specified and as directed. |
| 33 | Supply only switch piano 15 Amps flush type one way 230 Volts,50 Hz , AC supply, complete all as specified and as directed. |
| 34 | Supply only bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, complete all as specified and as directed. |
| 35 | Supply only socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as specified and as directed. |
| 36 | Supply only socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified and as directed. |
| 37 | Supply only ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed. |
| 38 | Supply only fan regulator electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and as directed. |
| 39 | Supply and fix door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified. |
| 40 | Supply only lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed. |
| 41 | Supply only switch modular 6 amps, one way single module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed. |
| 42 | Supply only switch modular 16 amps, one way single module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed. |
| 43 | Supply only socket modular 6 amps, 5 pin combined universal socket 2 module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed. |
| 44 | Supply only socket modular 6/16 amps, 2 in 1, combined universal socket 2 module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed. |
| 45 | Supply only fan regulator step type one module / 2 module, 120W, 230 Volts, 50 Hz, AC complete with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed. |
| 46 | Supply only bell pushmodularwith and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed. |
| 47 | Supply only Fan condenser 2.5 mfd complete all as specified and as directed. |
| 48 | Supply only PVC insulated, unsheathed cable 4.00 Sqmm single core 1100 volt grade with multi stranded copper conductor complete all as specified and as directed. |
| 49 | Supply only PVC insulated, unsheathed cable 2.5 Sqmm single core 1100 volt grade with multi stranded copper conductor complete all as specified and as directed. |
| 50 | Supply only Cable PVC copper conductor flexible twin core 0.75mm complete all as specified and directed. |
| 51 | Supply onlyMCB single pole, 240 volts, 50Hz , breaking capacity 10KA, \"B\" curve 6 to 32 Amps, ISI marked complete all as specified and as directed. |
| 52 | Supply only MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, \"B\" curve 40 to 63 Amps, ISI marked complete all as specified and as directed. |
| 53 | Supply only MCB single pole and neutral 240 volts, 16 to 32 Amps,10KA, 50 Hz,\"B\" Seriescomplete all as specified and as directed. |
| 54 | Supply only PVC Plug Top 3 pin suitable for 5/6 Amp socket complete all as specified and directed by Engr-in-Charge. |
| 55 | Supply only PVC Plug Top 3 pin suitable for 15 Amp socket complete all as specified and directed by Engr-in-Charge. |
| 56 | Supply only MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, \"B\" Seriescomplete all as specified and as directed. |
| 57 | Dismantling/taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc. complete all as specified and directed. |
| 58 | Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic,medium grade PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flushboxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paintincluding modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed.NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately.2. All chases will be cut by chase cutter only. |
| 59 | Description all as per item No 58.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed. |
| 60 | Description all as per item No 58.00 here in before but for socket out let point 5 Amps on independentboard complete all as specified and directed. |
| 61 | Description all as per srl item No 58.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switchwith using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed. |
| 62 | Material and labour for point wiring in existing conduit using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSHPVC insulated and unsheathed stranded cable drawn through inexisting non metallic/mettalicmedium grade concealed/Surface conduit and including replacement of its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paintincluding modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathedFRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/Bell Point controlled by one switch complete all as specified and as directed.NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately.2. All chases will be cut by chase cutter only. |
| 63 | Description all as per item No 62.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed. |
| 64 | Description all as per item No 62.00 here in before but for socket out let point 5 Amps on independentboard complete all as specified and directed. |
| 65 | Description all as per srl item No 62.00 above but point wiring for onesocket out let 15&5 Amps (independent) controlled by one switchwith using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed. |
| 66 | Supply and fix modular switches, one way,6 amps one module, 230V, 50 Hz supply, complete all as specified and directed. |
| 67 | Supply and fix modularswitches, oneway, 20 Amps, one module, 230 volt , AC supply, complete all as specified and directed. |
| 68 | Supply and fixmodular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed. |
| 69 | Supply and fix modular socket outlet 6/20 amps,3 pin, 2 module, complete all as specified and directed. |
| 70 | Supply and fix fan regulator step type one module / 2 module, 100w 230 Volts, 50 Hz, AC complete all as specified and directed. |
| 71 | Supply and fix modular switches, bell push,6 amps one module, 230V, 50 Hz supply, complete all as specified and directed. |
| 72 | Supply and fix modular blanking plate 1 module complete all as specified and directed. |
| 73 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with FRLSH )accessories, concealed on wall/ceilingand including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existing for one light/fan point/bell point controlled by one switch. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately . 2. All chases will be cut by chase cutter only. |
| 74 | Description all as per item No 73.00 here in before but for socket out let point 5 Amps on same board,complete all as specified and directed. |
| 75 | Description all as per item No 73.00 here in before but for socket out let point 5 Amps on independentboard,complete all as specified and directed. |
| 76 | Description all as per item No 73.00 above but with 2.5 Sqmm cable for 3pin 15 Amps switch socket outlet (Power Point),complete all as specified and directed. |
| 77 | Supply and fix switch piano 5 Amps, flush type, single pole, one way,230 volt , AC supply,ISI Marked, complete all as specified and directed. |
| 78 | Supply and fix switch piano 15 Amps flush type one way 230 Volts,50 Hz , AC supply, ISI Marked, complete all as specified and directed. |
| 79 | Supply and fix bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed. |
| 80 | Supply and fix socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as speciied and directed. |
| 81 | Supply and fix socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified. |
| 82 | Supply and fix ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified. |
| 83 | Supply and fix fan regulator electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and directed. |
| 84 | Supply and fix lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,complete all as specified. |
| 85 | Supply and fix door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified. |
| 86 | Supply and fix in repair sheet metal enclosure SP with two pin and earth plug and socketincluding metal clad top with one single pole, MCB 20 Amps, \"B\" curve, 240 volts complete all as specified and directed. |
| 87 | Supply and fixing of LED light fitting 1x20W , 220V,not less than 100 lumen per watt, AC with aluminium housing with batten type with driver , holder including 20W LED tube light for connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connector complete all as specifid and directed. Note: LED cool white/warm white must get approved from engineer-in-charge. |
| 88 | Supply and fix channel for fixing of LED tube rod of CRCA body suitable for 18/20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. ( Tube rod shall be measured and paid for separately ).Note: - Channelmust be get approved from Engr in charge to check fesibilty i.e. one end contact or two end contact |
| 89 | Supply and fix in repair 18 W/ 20WLED tube rod, environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed. Note: - Tube rod must be get approved from Engr in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing LED fittings . |
| 90 | Supply and fix batten type withsurface mounted LED tube light fitting with high efficient diffuser mirror light, polycarbonate housingin CRCA body suitable and including 10 watt LED tube rod high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.Note: LED cool white/warm white must get approved from engineer-in-charge. |
| 91 | Supply and fixbulk head light fitting, 10 watt, energy efficient withlamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting completeincluding disconnecting and taking down old existing light fitting of any descriptioncomplete all as specified and directed. |
| 92 | Supply and fixbracket for security light made up of 25/40mm dia suitable for security light, 0.9 metre long MS pipe,light grade, bent of 135 degree angle to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed. |
| 93 | Supply and fix LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDshaving optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any positioncomplete all as specified and directed. |
| 94 | Supply and fixLED security light luminaire 45 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed. |
| 95 | Supply and fixinverter LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDshaving optical grade polycarbonate lens with 4 hours battery back up all accessories internally pre wired and including connecting up with Two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed. |
| 96 | Supply and fixing of recess/ surface mounted LED flat panel 2\" x 2\" with high efficient LEDs and glare free full decorative light fitting, 36 watt, energy efficient provided withincluding LED36 watt withprovision of 2/3 core PVC copper conductor cab |
| 97 | Material and labour for sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 2.5 sqmm drawnin and including rigid non metallic PVC medium grade 20 mm dia New concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSHof 2.5 sqmm,green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed. NOTE: - 3 run of 2.50 sqmmcable with concealed conduct shall be measured as 1 unit. |
| 98 | Material and labour for sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 6sqmm drawnin and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSHof 6 sqmm, green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed. NOTE:-3 run of 6.0 sqmmcable with concealed conduct shall be measured as 1 unit. |
| 99 | Material and labour for sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 4 sqmm drawnin and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSHof 4 sqmm,green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed. NOTE:- 3 run of 4.0 sqmmcable with concealed conduct shall be measured as 1 unit. |
| 100 | Material & labour for earthing with Galvanised Steel earth plate electrode 60cmx 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by usingGalvanised Iron wire 4 mmas earthing lead(upto terminal point) by means ofbolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm diaGI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6)type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type ofsoil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 ofSSR 1991(Part-I) Taking out old unserviceable earthing complete all as specified and directed. NOTE : - The rates for earth work, GI protection pipe, funnel, wire wesh, CI cover, etc shall be deemed to beincluding in quoted rates. |
| 101 | Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and includingMCCB 4 pole thermal release type ,125AMPS ,25 KAas incomer and MCB sas out going complete with making suitable size of MS cabinet 1.2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed. |
| 102 | Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and includingMCCB 4 pole,100AMPS 16 KAas incomer and MCB sas out going complete with making suitable size of MS cabinet 1.2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed. |
| 103 | Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and includingMCCB 4 pole thermal release type ,160 AMPS ,25 KAas incomer and MCB sas out going complete with making suitable size of MS cabinet 1.2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed. |
| 104 | Supply and fixing in repairSPN distibution board 12 way, double door, IP 43, as per IS 8623including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets complete all as specified and directed. |
| 105 | Supply and fixing in repairSPN distibution board 8 way, double door, IP 43, as per IS 8623including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets complete all as specified and directed. |
| 106 | Supply and fixing of LED light fitting 1x22W , 220V, AC not less than 100 lumen per watt with batten type with driver , holder including 22W LED tube light for connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connector complete all as specifid and directed |
| 107 | Supply and fixing in repairSPN distibution board 4 way, double door, IP 43, as per IS 8623including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets complete all as specified and directed. |
| 108 | Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, \"B\" curve 6 to 32 Amps, ISIcomplete all as specified and directed. |
| 109 | Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, \"B\" curve 40 to 63 Amps, ISI marked complete all as specified and directed. |
| 110 | Supply and fixing in repair MCB single pole and neutral 240 volts, 16 to 32 Amps,10KA, 50 Hz,\"B\" Series complete all as specified and directed. |
| 111 | Supply and fixing in repair MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, \"B\" Seriescomplete all as specified and directed. |
| 112 | Supply and fixing sheet steel enclosure with separate busbar chamber for cable terminationwith and including MCCB four pole, 240 volts, 50Hz , breaking capacity 25KA, 125 Amps, thermal release type, complete all as specified and directed. |
| 113 | Supply and fixing sheet steel enclosure with separate busbar chamber for cable terminationwith and including MCCB four pole, 240 volts, 50Hz , breaking capacity 16KA, 100 Amps, thermal release type, complete all as specified and directed. |
| 114 | Supply and fixing in repair Isolator four pole, 240 volts, 50Hz , breaking capacity 16KA, 100 Amp complete all as specified and directed. |
| 115 | Supply and fixing in repair isolator four pole, 240 volts, 50Hz , breaking capacity 10KA, 63 Amps, C curve complete all as specified and directed. |
| 116 | Supply and fixing in repair PCB unit of suitable size for BLDC Ceiling fan of 1200mm sweep, single phase, 240 V complete all as specified and directed. |
| 117 | Supply and fix in repair post top lantern LED 30W , cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessoriesinternally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed. |
| 118 | Supply and fix in repairMCCB four pole 415 volts, 160 Amps,25KA, 50 Hz, thermal release complete all as specified and as directed. |
| 119 | Supply and fix in repairMCCB four pole 415 volts, 125 Amps,25KA, 50 Hz, thermal release complete all as specified and as directed. |
| 120 | Supply and fix in repairMCCB four pole 415 volts, 100 Amps,16KA, 50 Hz thermal release complete all as specified and as directed. |
| 121 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 6 Sqmm including all incoming and outgoing connection with proper size of thimble complete all as directed and specified. |
| 122 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 10 Sqmm including all incoming and outgoing connection with proper size of thimble complete all as directed and specified. |
| 123 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 16Sqmm including all incoming and outgoing connection with proper size of thimble complete all as directed and specified. |
| 124 | Material and labour for taking down existing lighting fiting any type/size/Make/capacity and re-fixing the same after minor repair/cleaning including replacement connection wire with suitable size coper wire twin core 0.75 sqmm for connection from ceiling rose to light fitting complete all as specified and directed. |
| 125 | Material and labourfor replacemnt of existing rusted modular metal flush box of 1 to 3 module and fixing of GI flush box of 1 to 3 module for housing of modular switch, sockets, regulators etc including taking down existing flush box and making good the disturbed surface after completion of work all as specified and as directed |
| 126 | Material and labourfor replacemnt of existing rusted modular metal flush box of 4 to 8 module and fixing of GI flush box of 4 to 8 module for housing of modular switch, sockets, regulators etc including taking down existing flush box and making good the disturbed surface after completion of work all as specified and as directed |
| 127 | Material and labourfor replacemnt of existing u/s modular cover plate with frame of 1 to 3 module and fixing modular cover plate of 1 to 3 module for housing of modular switch, sockets, regulators etc including taking down existing modular cover plate with frame all as specified and as directed |
| 128 | Material and labourfor replacemnt of existing u/s modular cover plate with frame of 4 to 8 module and fixing modular cover plate of 4 to 8 module for housing of modular switch, sockets, regulators etc including taking down existing modular cover plate with frame all as specified and as directed |
| 129 | Supply and fixing in repairs LED Lamps 9 Watt B22/E27 suitable for batten holder including taking down existing lamp of any description complete all as specified and directed. |
| 130 | Supply and fixing in repairs LED Lamps 12 Watt B22/E27 suitable for batten holder including taking down existing lamp of any description complete all as specified and directed. |
| 131 | Disconnecting and taking down old existing wall fitting of any description and in any position and Supply and fixing surface mounting type LED round type Decorative ,wall mouting , STYLO bowl type/metal base with glass with 7 Watt LED Warm white B22 Lampincluding connecting up with three core 1.5 sqmm flexible copper conductor cablecomplete all as specified and directed. |
| 132 | Supply and fix in repair LED based Bollard light 10 wattwith aluminium pipe housing not less than 65mm dia with glare free PMMA Diffuser, IP 65 of height not less than 600mm all as specified and directed. Note : price including taking down old, supply and fixing of new bollard along with connected work i.e. excavation, PCC block of 150x150x250mm etc. |
| 133 | Supply and fix in repair LED based Bollard light 15 wattwith aluminium pipe housing not less than 65mm dia with glare free PMMA Diffuser, IP 65 of height not less than 1 m all as specified and directed. Note : price including taking down old, supply and fixing of new bollard along with connected work i.e. excavation, PCC block of 150x150x250mm etc. |
| 134 | Material and labour for cutting & making hole in wall of suitable size in round/ square shape for fixing Exhaust fan of size upto 300mm sweep and making good with plaster / matching with existing surface complete all as specified and directed. |
| 135 | Supply and laying in trenches service cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power 1100 volts grade with stranded aluminium conductorof size 25 Sqmm 4 core complete in repairs all as specified and directed. |
| 136 | Supply and laying in trenches service cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power 1100 volts grade with stranded aluminium conductorof size 16 Sqmm 4 core complete in repairs all as specified and directed. |
| 137 | Supply and fixing cable protection GI Tubes of bore 50 mm ,\"light grade\" ,with all fittings and fixed complete to walls and ceilings or laid in floors,complete all as specified and directed. |
| 138 | Excavation in trenchesnot exceeding 1.5 Mtrs wide and not exc. 1.5 Mtr deep and getting out soft/loose soil complete all as specified and as directed by Engineer -in-Charge |
| 139 | Returning, filling in including spreading levelling , watering and well ramming in layers not exc 25cm thick after the cable have been laid testing complete all as specified and directed by Engineer -in-Charge |
| 140 | Removal of excavated surplus soil to a distance not exc 50 Mtrs and depositingwhere directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engineer-in-Charge |
| 141 | Material and Labour for unwashed dry sand cushioning for cable protection , fillingin treches complete all as specified and directed by Engineer-in-charge. |
| 142 | Material and labour for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks complete all as specified and directed. |
| 143 | NOTE:- Amount of credit ofRs. 1,14,394.00 for retrieved materials is mentioned in Schedule of Credit Page No 19 & 20 of tender documents in pdf form which will be deducted offline while acceptance of tender. |