Miscellaneous Civil Work At Bagol Gaushala, Nathdwara - Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soll and depositing and refilling of jhirt with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils Demolishing stone rubble masonry manually by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar Dismantling wood work in frames, trusses, purins and raftersup to 10 meter span and 5m height including, levelling stacking the material within 50m least Of sectional area below 40 5q.cm. Dismantling roofing including ridges, hips, valleys and rafters etc and stacking the within 50 meter least of. G.1. Sheet. Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 am. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. Camage of following material including loading unloading and stacking if required complete in all respect Earth, Sand, Lime, Moorum, manure or sludge, Building Rubbish, Stone Metal (Girt and ballast etc), Stone for Masonry work & Soling and Excavated rock etc for 5 km. Random rubble dry stone Kharanja under floor, Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering All work up to plinth level. M10 grade Nominal Mix 1.36 (1 cement 3 coarse sand: 8 graded stone aggregate 20mm nominal size) Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation, footings, strap beam, raft, bases of columns etc. Providing and laying in position specified grade of cement concrete for all ROC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers if required) excluding the cost of centering, shuttering and reinforcement M20 grade Nominal Mix/Design Mix Providing and laying cement concrete including ouring, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed biocks, anchor blocks, plain window sits, lets, levelling course etc up to foor five level excluding the cost of centering and shuttering M20 grade Nominal Mix 1: 1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). Centering & shuttering with plywood or steel sheets inauding strutting, propping bracing both ways with steel props and removal of formwork for upto finor five level for Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, silts, chhajas, Intel, beam, plinth beam etc Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level induding curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roots, griders having slopes up to 15, landings, balconies, shelves, chajjas, lintets, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix Design Mix Providing and fabricating reinforcement for RCC work including straightening, cutting, bending, placing in position in binding (including cost of binding wire) all complete up to floar three level Thermo mechanically treated bars (conforming to relevant IS code. Providing and laying in position cement concrete including curing, compaction etc complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level120 grade Nominal Mix 1: 1.5:3 (1 cement: 1.5 coarse sard: 3 graded stone aggregate 20mm nominal size). stone masonry for with hard stone in foundation and plinth in. Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:0 (1-Cement: 6-Band) Random Rubble stone masonry with hard stone in superstructure above plinth level and upto live level above 30cm. thick walis in: Cement Mortar 1.0 (1-Cement: 6-Sand) Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 14 (1 cement: 4 coarse sand Plaster on new surface on walls in cement sand mortar 1.4 including racking of joints etc. complete fine finish 25 mm thick. Finishing with neat cement (punning). Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1: 4 (1 cement: 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm Providing and fixing steel gate, grating, and grills made of angles, tees, square bars, flats, or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 mifixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished welded type tubes. Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated Jor L hooks, boils and nuts & mm diameter with bitumen and G.1. limpet washers or with G.1. limpet washers led with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontall vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 0.03 mm thick with zinc coating not less than 275 gm/m2 Colour washing of all shades to give an even shade including all scaffolding New work (two or more coats) with a base coat of white washing with lime. Providing and fixing 15 am wide 45 cm over all semi circular plain GS. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc including making necessary connections with rain water pipes complete, 0.83mm thick P&F ngid PVC Pipe (15:4985 mark) class 11/ 14 Kg. /0m2) approved quality make including joining the pipe with solvent cement rubber ring and lubricant Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement 2 coarse sand: 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design Half brick masonry in Superstructure, above plinth level upto floor V level using bricks of designation 75 Cement mortar 1:4 (1) cement: 4 coarse sand) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mam nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (15:504) of approved make in surface/moessed Si marked medium duty PVC conduit & its accessodes, round tiles, Hot Dipped Galvanized Modular Box with earth terminal, & A Modular switch, Modular plate with grid plate, screws, making connections, testing etc as required. Short point (up to 3 mtr.) Medium point (up to fl mir) Long point (up to 10 mtr) Supplying and fixing of power plug point Modular socessones on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover gate including cost of modular 16 amp. Switch and socket outlet making connection testing, etc as required. Supplying and drawing FR PVC insulated & unsheathed fexible copper conductor ISI marked (15:094) of 1,1 kV grade and approved make in existing surface or recessed conduiticasing capping including making connections etc. as required Gr-1 1 x 1.6 sq.mm. 2x2.5 sq. mm + 1x1.5sqmm 2 x 4.0 sq. mm. 1x2.5 sq mm. 2x60 sq mm. +1 x 2.5 sq. mm. P&F 240/415 V MCB of breaking capacity not less than 10 KA (B C/D tripping characteristic) Il marked 15 8828(1996)/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required GROUP 1 Single pole MCB A to 32 A rating Four pole MCB 40 A 63 A rating B&F following sizes (dia) of ISI marked virgin material MIMS ( 18:9537P) PVC conduit along with ISI marked (15:3419-1988) accessories as required in recess including cutting the wal covering conduit and making good the same as required. For additional technical parameters of product/work refer Annexure A attached with this BSR 20 mm 25 mm Providing & Fixing of HEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade cailing fan Confarming to all the performance requirements laid down in 15 374:2019 including all amendments, as applicabile; & Carry Bl5 licensing (in marking) with down rod up to 80 cm with secondary support safety cabile (steel ropel catter pin with x 1.5 sq.mm рис іnsulated flexible copper conductor making connection Testing ets as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure A attached with the 5-1200 mm Sweep REE 3 Star rabed (service value 5.0 to 5.5) P&P following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc as required & step fan regulator 2 Module fire retardant poly carbonate with silver contacts including making connections testing eto as required 5 step fan regulator 2 Module Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver System lumen efficacy z 110 Im/Walt output, internal surge protection of 25 KV with Short & Open circuit protection, THD 10% P. F20 95. CRI >80, lite time of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends CCT 3000K/4000K/5700K 5000 K/6500K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate (TC). Manufactures Word Mark Name Engraved Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED foxtures (LM79 & LM80) certificate/ Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure A attached with this BSR 570mm (+/-10%) batten with min. lumen output 1000 Im Supply & Laying following size earth wire in horizontal or vertical run in ground surface/recess including riveting, soldering, saddles. making connection with Gl/Cu purity purity 95% thimble eis, as required. Al as per pre approved by Engineer in charge For additional technical parameters of products work refer Annexure A attached with this BSR & SWG tinned copper Wire Plate Earthing as per 15:3043 with Hot dipped G.J. Earth plate of size 600mm x 600mm x 8.0mm by embodying 3 to 4 mtr, below the ground level with 20 mm da DI B dass watering Pipe Including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid sutable for safe working load 5000 Kg or more of size Top Dia. 225 10 260 mm. Bottom Dia 300 to 350 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products work refer Annexure A attached with this BSR Providing & Fixing of Recessedisurface mounting heavy duty horizorital type Double Door (Metal/ Glazed Distribution board with Metal end box made out from Galvanized steel/CRCA sheet not less then 1.2 mm thick conforming to 18-8823-14 3/IEC 81430-1 & 3, powder painted complete with reversible door (for) double door DB only 100 amp. Insulated copper bus bar/shorting link copper neutral link, copper earth link color coded interconnecting wire set of suitable rating and din bar masking sheet, making internal DB terminations with copper luga Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL/CPRI/ ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product/ work refer Annexure A attached with this BSR4 Way (2) 16 Way (10+2) Providing & Laying P.V.C./XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to 18:1554 P47187098 P 1 of 1.1 KV with H4 Grade slectrolytic aluminium conductor confirming to 15 8130 of purity >99.0%, round/ flat strip armouring of cables, Inner/outer sheath confirming to 15:5831 in existing RCC/Hume/Stoneware/PVC pipe/ open duct/sable trench Cable tray(with cable tie) including testing etc. as required of following size: OEM must have its own in house NABL accrediated Laboratory for testing procedure as per 15:10810 For additional technical parameters of product/work refer Annexure A attached with this BSR 25aq mm 3.5 core Providing & Fixing of IK08, IP 68 protected LED Street Light Luminaire on existing bracketipole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV) stablization report submitted for UV cover) (Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each. The System efficacy > 125 im/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff 300 V AC and Auto resetting Safety Power Factor 0.95 driver Efficiency >85% THD(1) <10% Humidity 10% to 90% RH Working Temp -SC to 45C driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened, CRI >70 and CCT 5700K +355K. Surge protection shall be min 24 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity, Fixture shall be AS PER IS 10322 Complianced OEM Must have its own in house NABI, lab setup for all testing facilities for LED foxtures. (LM79/LM80) Certificate/ report with lable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge For additional technical parameters of products/ work refer Annexure A attached with this BSB LED Street Light fidure with Minimum Providing & Fixing of Street light bracket made out from following size of B class Medium class G1. Pipe confirming to IS: 1239 P-1 (2004) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure A attached with this BSR 32 mm Dia