Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-01-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-02-2025 |
| Sl. No. | Item Description |
| 1 | Taking down old/burnt cable of any size and Supply and fixing Aerial bunched cable (AB) LT of size 3 core- x50sqmm+1-core x35 sqmm with three power cores stranded compacted circular aluminium conductor screened with black extruded semiconducting compound, natural coloured XLPE insulated core screened with black extruded semi conducting compound and one layer of copper tape and covered with black extruded PVC(core identification by colour tape marking red, yellow and blue with colour tape placed longitudinally under the copper tape) and one bare messenger wire shall be stranded non compacted circular aluminium alloy conductor all as specified and directed. Make-KEI, Havells, Gloster, PolycabNote:- The following hardware fittings and accessories shall be used to install erect and join the AB cable(i) Suspension clamp with eye hook(ii) Suspension fittings and corresponding eye hook(iii) Dead eye fittings(iv) Nylon Tie(v) connectors |
| 2 | Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 6 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 3 | Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 10 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 4 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 5 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 25 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 6 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 35 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 7 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 8 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 70 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 9 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 95 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 10 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 120 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 11 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 150 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 12 | S & F in replacement of LT cable joint kit complete set of heat shrink type, straight through of size 16 sqmm to 50 sqmm 04 core incl excavation and returning filling and making good distrubed surface complete all as specified and directed. |
| 13 | S & F in replacement of LT cable joint kit complete set of heat shrink type, straight through of size 70 sqmm to 95 sqmm 04 core incl excavation and returning filling and making good distrubed surface complete all as specified and directed. |
| 14 | S & F in replacement of LT cable joint kit complete set of heat shrink type, straight through of size 120 sqmm to 150 sqmm 04 core incl excavation and returning filling and making good distrubed surface complete all as specified and directed. |
| 15 | Cutting/trimming/Choppingof tree branches along the over head lines of LTupto 5 mtr from elect line on both sides of the span and disposing off the cut trees/branches to a distance of n.exc 50m and clearing the site as directed. |
| 16 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 16 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 17 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 25 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 18 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 35 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 19 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 50 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 20 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 70 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 21 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 95 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 22 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 120 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 23 | Replacement of aluminium cable thimbles/ line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 150 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells |
| 24 | Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6CM with Reinforcement bars of 8mm dia @120mm c/c excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. |
| 25 | Excavation in trenches not exceeding1.5 m wideand not exceeding 1.5 m deep for laying cable including gettingout in any type of soil complete all as specified and directed. |
| 26 | Returning filling including spreadingwateringand well ramming in layers not exc25cmcomplete all as specifed . |
| 27 | Removing surplus soilto distance not exceeding50 m and depositing where directed at a level notexceeding 1.5 m above the starting pointcomplete all asspecifiedand directed . |
| 28 | Sand cushioning to under ground cable, 8 cms thick before laying the cable and 15 cms thick after laying and stretching the cable in trenches including hand punning and consolidating, punned to 18cm thickness, complete all as specified and directed. Note : For payment purpose, only punned thickness shall be measured. |
| 29 | Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed. |
| 30 | S&F in replacement of steel tubular swaged type LT poles 9 meters long, pole should be in one piece only and smooth finishing and smooth finishing of pole, ISI marked complete with all accessories such as cast iron base plate, finial taper plug,bolts, nuts, screws, washers and drilling of holes for continuous Gl earth wire as specified type 410 SP-31 including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface incl taking down old PCC/Steel tubular pole complete all as specified and directed. |
| 31 | PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete all as specified. |
| 32 | PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in pole coping, roof kerbsincluding necessary form work, complete all as specified and directed. |
| 33 | S&F in replacement of MCCB, 4 Pole, Adjustable thermal & fixed magnetic, braking capacity 25 KA, 100 Amp complete incl fixing in existing LT panel with necessary arrengment complete all as specified and directed. |
| 34 | S&F in replacement of MCCB, 4 Pole, Adjustable thermal & fixed magnetic, braking capacity 36 KA, 125 Amp complete incl fixing in existing LT panel with necessary arrengment complete all as specified and directed. |
| 35 | S&F in replacement of MCCB, 4 Pole, Adjustable thermal & fixed magnetic, braking capacity 36 KA, 200 Amp complete incl fixing in existing LT panel with necessary arrengment complete all as specified and directed. |
| 36 | S&F in replacement of on load change over switch, 4 Pole, capacity 160 Amp with SS enclosure complete incl fixing on wall, open excution type with necessary fixing arrengment complete all as specified and directed. |
| 37 | S&F in replacement of on load change over switch, 4 Pole, capacity 200 Amp with SS enclosure complete incl fixing on wall, open excution type with necessary fixing arrengment complete all as specified and directed. |
| 38 | S&F in replacement of 50mm bore tubes \"light grade\" galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cable all as specified and as directed. |
| 39 | Scrapping existing painting of pumpset of capacity 60 HP incl painting of steel base structure, exposed suction/delivery pipe, valve header complete with emery paper/ wire brush and repaintingwithtwo coat of synthetic enamel paint ofcolour approved by Engr-in-charge all as specified and directed. Make of paint Asian , Berger, Durolux or equivalent as approved. |
| 40 | Scrapping existing painting of pumpset of capacity 20 HP incl painting of steel base structure, exposed suction/delivery pipe, valve header complete with emery paper/ wire brush and repaintingwithtwo coat of synthetic enamel paint ofcolour approved by Engr-in-charge all as specified and directed. Make of paint Asian , Berger, Durolux as approved. |
| 41 | Taking down 60 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting,and rewinding with super enamelled copper wire of best quality of existing size/guage and weight includingreplacement of insulation material ,varnish,bearing,connection plate and all other petty items required to make motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. |
| 42 | Taking down 20HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting,and rewinding with super enamelled copper wire of best quality of existing size/guage and weight includingreplacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed.Note for srl item No 41 & 42 (i) Transportation charges from installation to contractor workshop and back after repair are deemed to be included in the unit rate quoted for above item (ii) Cost of nuts, bolts, washers,connection plate,greese lubrication to bearing bushes ets are deemed to be included and However, supply only bearings and terminal plates will be measured and paid separetly under respective items. |
| 43 | Supply only the following parts for incorporating in item No 41 and 42 here-in-before :- |
| 44 | Motor bearingsfor 60 HP motor as per sample Make SKF/NBC, as approved. |
| 45 | Motor bearings for 20 HP motor as per sample Make SKF/NBC, as approved. |
| 46 | Terminal plate with brass nuts, washers suitable for 3 phase 60 HP Motor, as approved. |
| 47 | Terminal plate with brass nuts, washers suitable for 3 phase 20 HP Motor, as approved. |
| 48 | \"Supply and fixing in replacementof LT Panel board indoor type with neoprene rubber gasket and locking arrangement vermin/ dust/ weather proof, self ventilation with wire mesh at suitable interval on both side, totally enclosed bus bar chamber fullycomparted type, frontopenable hinged independent door for each compartment with lockingarrangement and common openable hinged door from rear side of suitable size made out of 2 mm thick CRCA sheet duly powdercoated paint factory made (CPRF approved), 415 volts, TPN, 50 Hz both sides properly welded MS angle 50x50x6mm 4 Nos, at all vertical corners grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) and connecting the incoming/ out going feeders by providing cable glands and cable lugs complete all as specified and didrected comprising of following accessories.Make of panel- Indian Transformers & Electricals Pvt Ltd. Gurgaon, Legrand, Schnieder, L&T Note :- Panel should be TTA in accordance with IEC 61439 part I &IIand shall comprise the following :- |
| 49 | MCCB TP NL LT 415 volt 50 Hz, AC 160 Amps 36 KA with adjustable thermal setting With on/off/trip indicator.andStandard Extended Rotary Handle, Spreaders, Phase Barrier.-01 NoMake :-L&T/legrand/Schneider(ii) Soft Starter 60 H.P. contactors, relays, CT/PT, timers, ROMfor suitable rating having inbuilt display with ON, OFF , Trip Indicating Light, Push Buttons, Digital MFM with CT, Control Fuse etc fitted in panel board for showing V,I,Hz,Pf complete all as specified and directed- 01 Nos.Make-L&T/Siemen/Schnieder (iii) Smart Motor Controller Protection Having Feature as Protection against UV,OV, Phase loss,Phase unblanced , Phase Asymetery & Auto Phase Polarity Correction with Time Delay & Having Display of V, I ,Pf, Hz for 100 Amp- 1 No. |
| 50 | Dismantling and Taking down centrifugal pumpset from plateform and disconnecting suction and delivery pipe line and electrical connections, transport the same to workshop for repair and after repairing transporting the pumpset from workshop to site , installation at site connecting suction and delivery pipe and electrical connection complete all as directed by Engineer-in-charge for 60 HP pump capacity Note :- The rate is deemed to be included the cost of providing foundation nuts,bolts and washers gland packing, greasing,oiling and oil sheet gasket (ii) The spare parts will be measured and paid separately under relevant items of supply only. |
| 51 | Description all as per Srl Item No 45 here-in-before, but of capacity 20 HP. |
| 52 | Supply only the following parts for fixing in 60HP Capacity centrifugal pumpset:- |
| 53 | Bronze impeller |
| 54 | Casing ring |
| 55 | Impeller ring brass nut |
| 56 | Impeller key |
| 57 | Coupling key |
| 58 | Coupling rubber bushes |
| 59 | Shaft sleeve(steel) |
| 60 | Bearing |
| 61 | Shaft (steel) |
| 62 | Brass bush |
| 63 | Gland bolt/nut |
| 64 | Supply only the following parts for incorporating in 20HP Capacity centrifugal pumpset:- |
| 65 | Bronze impeller |
| 66 | Casing ring |
| 67 | Impeller ring brass nut |
| 68 | Impeller key |
| 69 | Coupling key |
| 70 | Coupling rubber bushes |
| 71 | Shaft sleeve(steel) |
| 72 | Bearing |
| 73 | Shaft (steel) |
| 74 | Brass bush |
| 75 | Gland bolt/nut |
| 76 | Lifting submersible pump from the existing bore hole/tube well for repairs complete including disconnecting electric connections from starter, disconnecting the water connections carefully by unscrewing the nuts, bolts, washers, rubber flanges etc and taking out the submersible pump set of capacity 12.5 HP with column pipes of size 80/100/150 mm bore and two runs of submersible cable and stacking properly for reuse and lowering complete in borewell afterrepairs from workshop, rejointing each column pipe, submersible cable connection, testing, complete all as specified & directed. Note :-(i) Transportation charges from installation to contractor workshop and back after repair are deemed to be included in the unit rate quoted for above item (ii) Cost of nuts, bolts, washers,connection plate, greese lubrication to bearing bushes ets are deemed to be included in the quoted rates. However, Supply ofrelevant parts of pumps and motorswill be measured and paid separetly. |
| 77 | Supply only following spare parts for submersible pumpset:- |
| 78 | Impeller brass |
| 79 | Stage bowl |
| 80 | Bowl fixing steel nut and bolt |
| 81 | Bearing sleeve |
| 82 | Bearing bush |
| 83 | Neck ring |
| 84 | Casing wear ring |
| 85 | Shaft steel |
| 86 | Strainer |
| 87 | Stage gasket |
| 88 | Rewinding of AC 3 phase submersible motor of capacity 12.5 HP by cutting of burnt out winding, cleaning of starter slots, cleaning,bleaching of motor and rewinding with appropriate guage of copper winding wire complete including all required parts complete all as specified and directed. Note: Taking down of unsv parts and fixing the same with new ones in the item Nowill be taken under relevant items here-in-after. |
| 89 | Supply only following spare parts of motor of submersible pumpset:- |
| 90 | Thrust bearing plate |
| 91 | Motor bearing bush |
| 92 | Assembly for coupling sleeve |
| 93 | Drain plug |
| 94 | Sand guard |
| 95 | Key for thrust plate |
| 96 | Supply and fixing Vinyl display board of frame size 6 ft x 4 ftshowing schematic diagram of electric/water supply distribution network as sketch provided to be fixed on walls in installationall as specified and directed. |
| 97 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified anddirected. |
| 98 | Materialand labour for point wiring complete with 1.5 sqmm PVC insulated, FRLStype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including Casing and caping of suitable size on walls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colouresandincluding 1.5 Sqmm PVC insulated multistranded FRLStype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:-(Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washers to be used of same make/brand onlyand shall be deemed in to included in quoted rate only.) |
| 99 | One light point/fan /bell pointcontrolled by one switch. |
| 100 | One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . |
| 101 | One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . |
| 102 | Materialand labour for point wiring complete with 2.5 sqmm PVC insulated, FRLStype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including Casing and caping of suitable size on walls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colouresandincluding 2.5 Sqmm PVC insulated multistranded FRLStype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:-(Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washers are to be used of same make/brand onlyand shall be deemed in to included in quoted rate only.) for One 6 pin 16/6 amps power socket outlet point controlled by one 16 amps switchon independent board. |
| 103 | Modular type switch 6 Amps, single pole, 1way,1 module, 240V, ISI Marked including Modular cover plate with frame Complete all as specified and as approved by GE.“Cat part No:- Crabtree (Havells) or its equivalent cat part of makeAnchor, Legrand, Schneider as approved by GE”. |
| 104 | Modular type switch 16 Amps, single pole, 1way,1 module, 240V, ISI Markedincluding Modular cover plate with frame Complete all as specified and as approved by GE.“Cat part No:- Crabtree (Havells) or its equivalent cat part of makeAnchor, Legrand, Schneider as approved by GE”. |
| 105 | Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Markedincluding Modular cover plate with frame Complete all as specified and as approved by GE.“Cat part No:- Crabtree (Havells) or its equivalent cat part of makeAnchor, Legrand, Schneider as approved by GE”. |
| 106 | Modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Markedincluding Modular cover plate with frame Complete all as specified and as approved by GE.“Cat part No:- Crabtree (Havells) or its equivalent cat part of makeAnchor, Legrand, Schneider as approved by GE”. |
| 107 | Fan regulator modular type electronic compatible with BLDC fan, stepped type 100 Watts, 2 module 240Volts, AC ISI marked complete all as specified and directed.“Cat part No:- Crabtree (Havells) or its equivalent cat part of makeAnchor, Legrand, Schneider as approved by GE”. |
| 108 | Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 109 | Energy saving LED lamps 7 watt, 230 volts, 50 HZ , 0.95 PF. Complete all as specified.Make- Havell Cat part No LHLDERHEMD8X007 or equivalent of Make-Phillips, Crompton, wipro, bajaj as approved. |
| 110 | Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed |
| 111 | LED light fitting decorative box type 20 watt, 4 feet, 85%energy efficiency,0.9 PF, inbuilt driver, pre-wired and connecting up with twin core twisted copper wire from LED fitting to ceiling roseand removing old unserviceable fitting complete all as specified and directed.Cat Part No-BS20WLED 830 SPCSS of Havells or its equivalent of Bajaj, Crompton, Orient as approved. |
| 112 | LED light fitting decorative box type 10 watt, 2 feet, 85%energy efficiency,0.9 PF, inbuilt driver, pre-wired and connecting up with twin core twisted copper wire from LED fitting to ceiling roseand removing old unserviceable fitting complete all as specified and directed. Cat Part No-BS10WLED865 SPCSS of Havells or its equivalent of Bajaj, Crompton, Orient as approved. |
| 113 | LED light fitting 1x10W, 220V, Bulk head luminaries including LED driver holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make- Havell Cat part No-RUGBYGENXFTS10WLED865SSYMBOPC or equivalent of Make-Phillips, Crompton, wipro, bajaj as approved. |
| 114 | Supply & fixing and in repair sheet metal enclosure acrylic door 240 volts AC,SPNdistribution board 8 wayfor flush mounting with 200amps copper busbar,neutral bar,earth barand MCB incomer of rating upto 100Amps ,MCB SPN/DP,and MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plate withIP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coatall as specified and as directed. Make:- Legrand cat Part No. 5076 21 8 way / Hager cat Part No.VYS08G / L&T Cat Part No:-DBSPN008GD as approved |
| 115 | MCB single pole & neutral 40 to 63 amps 240 volts 10 KA \"C\" series fixed in repair, complete all as specified.Make:-Havells cat part No-DHMGCSPF040or its equivalent cat part of make-Legrand / ABB / L&T as approved by GE |
| 116 | MCB SP 6 to 32 Amps 10 KA,\"C\" series,AC,240Volts,50Hz , ISI marked fixed in repairs complete all as specified and directed.Make:- Legrand cat No.4085 87 to 4085 95 / Hager Cat Ref No.NCN106N to NCN132N / Havells Cat No.DHMGCSPF006-032as approved |
| 117 | Sub main wiring complete with 2 runs of 6 sqmm single core copper conductor (ISI marked)cable1100 volts grade,FRLS type, PVC insulated, unsheathed, flexible, multi strandedcolour coded cables drawn throughrigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLStype as earth continuity conductor connected to common earth dollyincluding making good the disturbed surfaces to match with existing surface including taking down of old existing submain cable complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 118 | Supply & fixing and in repair sheet metal enclosure double door 240 volts AC, VTPNdistribution board 4 wayfor flush mounting with 200amps copper busbar,neutral bar,earth barand MCB incomer of rating upto 125Amps and MCB SP/DPas outgoing and complete connecting cable linkswith top and bottom removable gland plate withIP 43 DBs protection and including M&L for MCCB 125Amp, TPN 16KA, 415 Volts as incomer and 06 Nos MCB, SP, 63 Amp, C Series as outgoing including making good the disturbed surfaces to match with existing surface and colour coatall as specified and as directed. Make:- Legrand cat Part No. Indo asian 811888 equivalent to Havells, L&T/ Legrand as approved |
| 119 | Taking down old /unsv earthing and Earthing complete with galvanized steel earth plate electrode 600mm x600mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground leel, connecting to the Galvanised earthing lead strip 32x6mm size, by means of bolts, nuts, heck nuts and washers of galvanized iron and earth lead protected by provision of GI medium grade pipe 65mm bore incl provision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape Gl medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 40mm x 8mm Fl with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs, all as per electrical plate No 5 of SSR-1991 Part I and connected to earth test point all as specified or indicated incl testing on completion. |
| 120 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 70 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 121 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 95 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 122 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 120 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 123 | Surface dressing in hard/dense soil n exc averaging 15cm deep for cleaning the area by cutting the unwanted bushes/vegitation growth in and around the area of installations/around the valve pit chamber/along the pipe line route if required etc all as specified and directed. |
| 124 | Taking down old/unsv flood lights from high mast light of any type and S&F LED flood light of capacity100 watt built withdie-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lightingand making connection with copper flexible cable of suitable size to light fitting fixed, complete all as specified and directed.Cat part No;- LF20-122-060-57-G2 or its equivalent cat part of Make as specified in list of make here in after as spproved by GE. |
| 125 | MCCB , 4 Pole, adjustable thermal & fixed magnetic, braking capacity 36 KA, 125 Amp complete incl fixing in replacement existing LT panel with necessary arrangement complete all as specified and directed. |
| 126 | MCCB , 4 Pole, adjustable thermal & fixed magnetic, braking capacity 36 KA, 200Amp complete incl fixing in replacement existing LT panel with necessary arrangement complete all as specified and directed. |
| 127 | On load change over switch, 4 pole, capacity 160 Amp with SS enclosure complete including fixing in replacement on wall, open execution type with necessary fixing arrangement complete all as specified and directed. |
| 128 | On load change over switch, 4 pole, capacity 200 Amp with SS enclosure complete including fixing in replacement on wall, open execution type with necessary fixing arrangement complete all as specified and directed. |
| 129 | LED light luminaire 600mm x 600mm 35/36 watt, 220 AV recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, Holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size in repairs complete all as specified and directed.Cat Part No-PLANO2X2PLR36WLED 865TAPS of make Havells or equivalent cat part of make as specified in the list of makes here-in-after as approved by GE. |
| 130 | Supply and fixing in replacement “Lithium based Energy Efficient Integrated Solar Street Light of 24 Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 53/55Wp , Lithium Battery 11.1/12.8V, 28.6AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 12-14kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant. CAT part No- SOLAR AIO 24 W ofMake Havells or equivalent cat part of Make as specified in list of make here in after as approved by GE. |
| 131 | Chlorine testing kit complete with test tubes, solution complete all as specified and directed. |
| 132 | Portability test of the water sample collected at dugwell water points and send to the authorized laboratory and submission of the test report complete all as directed. |
| 133 | Star-delta starter manually operated 3 phase 415 volts, wall mounted suitable for operating submersible pump motor of capacity upto 30 HP fixed in repairs complete all as specified and directed. |
| 134 | Supply and laying in replacement of submersible cable of copper conductor flat or circular, 1100 volt grade of size 10 Sq mm 3 core incl copper lugs complete all as specified and directed. |
| 135 | Supply, laying and testing ERW MS pipe line of 80 mm bore size MS flanged 15 mm thick welded on both ends of ERW tubing incl nuts, bolts washer and packing material (Rubber sheet) etc Pipes laid in ground or passing through Yards or on Pillars incl taking down old unsv CI/MS/GI pipe complete all as specified and as directed.Note: The rate for cutting of road, path, culvert, floor etc for laying of pipeline and making good the damaged surface deemed to be included in the quoted rate. |
| 136 | Supply only chlorination chemical highly efficient (high strength) calcium based granular(65 to 70% chlorine content) disinfectant more stable than chlorine gas/bleaching powder high stable in sealed container for water treatment stability projected shelf life of chlorination of chemical must be one year with min loss of chlorine ISI marked as approved. Note:- The contractor has to produce manufacturer test certificate and purchase voucher from authrozied dealer for every lot of item of calcium based granual for the verification of genuineness of material. No material is accepted without test certificate. |
| 137 | S&F in repairs for Heavy duty Chemical Dosing system plunger type suitable to inject solution upto 25 LPH working pressure 10 kg/cm2 comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM assembly with agitator in one motor, agitator with SS sweep blade duly FRP coated, FRP tank 150 Itrs capacity, complete unit mounted on heavy duty MS fabricated frame duly anticorrosive paint complete with Chemical grade PVC NRV. along with Control panel for Dosing Pump suitable for Model SSAPS/CDSPT/25 made of powder coated MS fabricated box consisting of LED indicator, digital Volt meter, Amp meter, single phase preventor, High voltage low voltage protection incl UPVC pipe conection, ball valve and 2.5 sqmm three phase pvc cable connection as required at site complete all as directed.Model No:- SSAPS/CDSPT/25/ST of Sathya Sai Aqua Pura Services or its equivalent in Matrix International/ Flow Control Pumps & Systems Pvt. Ltd. Nashik/ Declibag technologies pvt ltd or equivalent make approved by Garrison Engineer |
| 138 | S&F in repairs for mechanical joint with both end flange alongwith nut, bolt, washer etc complete suitable for fixing CI/DI pipe of size 150 mm dia by cutting of rusted / damaged pipe incl excavation of soil and returning filling complete all as directed. |
| 139 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 140 | Pre cast Reinforced cement concrete 1:2:4, B-1 (Using 20mm graded crushed stone aggregate) as in manhole covers slab/shelves etc in cement mortar 1:6including necessary form work for fair finished surfaces complete all as specified and directed. |
| 141 | TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail