| 1 | S&F Installation, testing and commissioning ofMultigrade filter plant alongwith required footing work for commissioning of the sameas per following descriptions:-(a) One No. Multigrade filter plantcapacity of 125 Cum/Hr (MGF 2400) of size not less than 2400mm dia x 1875mm height with internals,Shell thickness 6 MM,Dish end thickness 8.0 MM,MS frontal pipe work 150 MM inlet to outlet terminals with valves, initial chargeofspeciallygraded filter sandmedia with supportingunder bed media. Make :ION Exchange/ Pearl Filters or equiv(b) Interconnecting Pipes 01 Lot for interconnection,Mild steel as per IS 2062 duly painted internally with 2 coats of potable quality anticorrosive bituminous black paint and externally 2 coats of synthetic paint over a coat of red oxide primer complete Vertical, single deck and multi grade pressure filter plant , filter media not less than 6560 Kgs,Media depth 915 MM .(c) Feed Pump ofcapacity 125Cum/Hr at 25/30 Mtr headwith suitable Induction motor -02 Nos and suitable foundation work.Make : Kirloskar/Crompton Greaves. Note For Srl item No 01 :(i)Painting charges for filter shell, oxidation chamber and pipe line shall be inclusive in the rate quoted by the contractor against this item.(ii)The quoted rate against this item shall be inclusive of all materials as per manufactures drawings design and specification frontal pipe line (above filter shell),level gauge, inlet/outlet connection - 01 Set,and civil worksincluding drain & pit to accommodate the entire plant etc as well as any misc fittings Tee, bend, MS pipe in required length including welding charges to connect filter plant with existing raw water pipe line(iii) The depth and quantity or filter media shall be as per manufacturers’/ particular specification.The plant shall be installed matching with existing water supply system including m&l for necessary connection/modification etc complete all as specified and as directediv) The size,thick and Quantity of gravels and Catalytic media shall be as per manufacturer standard description and as given in particular specification.(v)The plant shall have air release arrangement with 02 (Two) Nos pressure gauge to monitor head loss across the filter and sampling cocks on the inlet and outlet ends.(vi) The filter vessel shall have manhole, hand hole.and supporting legs complete in all respect. (vii) The drawing of same should be proposed by OEM and approved by GE before commencing of the work. |
| 2 | S&F Chemical/Polymer dosing system CDS-3 type with slow speed agitator for polymer dosing to floculator for increasing the process with connecting pipe lines all as specified and directed with Polymer (INDFLOC-238 or equiv Qty 50 Kg) tank capacity 150ltrs, Discharge 6 ltrs/Hr at 4 Kg/cm2 all as specified and directed. |
| 3 | S&F Chemicaldosing system CDS-3 type with high speed agitator for chlorine dosing toaeration chamber for prechlorination alongwith connecting pipe line, tank capacity 150ltrs, Discharge maximum 6 ltrs/Hr at 4 Kg/cm2 all as specified and directed. |
| 4 | Excavating in trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth for taking out/laying of under ground cable, pole or stay and getting out in soft/loose soil, complete all as specified and as directed. |
| 5 | Returning filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed. NOTE : The top of filled trench shall be made proud by using the excavated soil to cater for subsequent settlement of soil. |
| 6 | Removing excavated materials (soils) not exc 50.00mtr and depositing where directed at a level not exc 1.50 mtr above the starting point in soil, complete all as specified and as directed. |
| 7 | Supply and fix steel water tubing, galvanized, medium grade, with all fittings like bends, sockets, reducers etc as required in new or old alignment, on floor, trenches, vertically on overhead reservoir,complete all as specified and directed for following sizes:- Make: Jindal/ Prakash/ Tata |
| 8 | 200 mm bore |
| 9 | 150 mm bore |
| 10 | 100 mm bore |
| 11 | 40 mm bore |
| 12 | 20 mm bore |
| 13 | Supply and fix 200 mm bore CI Sluice valve PN-1.6 IS 14846-2000 with Spindle Iron (Heavy duty) Wheel head and both ends flanged and MS nut bolts and washers and pair of rubber/fiber gasket and fixed in position complete all as specified and directed. Make:-Zoloto/Kirloskar/ Leader |
| 14 | Supply and fix 150 mm bore CI Sluice valve PN-1.6 IS 14846-2000 with Spindle Iron (Heavy duty) Wheel head and both ends flanged and MS nut bolts and washers and pair of rubber/fiber gasket and fixed in position complete all as specified and directed. Make:-Zoloto/Kirloskar/ Leader |
| 15 | Supply and fix valve, reflux (NRV), with by pass arrangement 15 mm bore complete all as specified and directed. Make:-Zoloto/Kirloskar/ Leader |
| 16 | M & L Reinforced cement concrete1:2:4 nominal mixtype B1 using 20 mm graded aggregateas in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed . |
| 17 | M & L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 18 | M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 19 | M&L for CI/DI fittings for spigot & socketed CI pipes such as bends ( any type, radius & angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.), tee pieces single branch, \"Y\" junction, double branch, cross (all sockets or socket & spigot) collars, caps & plugs upto 300 mm bore complete all as specified and directed. |
| 20 | M&L forConstruction of brick masonary valve pit size 120x 120 x 120 CM (internal dimension) one brick thick wall in cm 1:4 and 100mm thick PCC 1:4:8 in foundation and 15 mm thick plastering.Providing valve pit cover made of 3.15 mm thick MS sheet/plate welded with 40x40x6 mm angle iron frame fixed or top of valve pit by means of hold fast 150mm long, embedded in PCC 1:2:4 type B1, bricks of size 230x110x75 including two coat of anticorrsive paint over a coat of red oxide primer and necessary earth work in soft/ loose soil complete all as specified and as directed. |
| 21 | M&L forCross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed. |
| 22 | Supply and fix/lay PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt of 25 Sqmm, conforming to IS 694 complete all as specified and directed.Make: Polycab(ISI Marked)/ Finolex(ISI Marked)/ Havells (ISI Marked)/ KEI (ISI Marked)/ Gloster (ISI Marked) |
| 23 | Supply and laying, connecting, testing, commissioning XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured,electric powercables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core conforming to IS 7098 laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc complete all as directed by Engr-In-Charge.Make: Polycab(ISI Marked)/ Finolex(ISI Marked)/ Havells (ISI Marked)/ KEI (ISI Marked)/ Gloster (ISI Marked)Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 24 | Supply and filling for dry sand in cable protection trenches before and after the cables are laid, for sand cushioning to cables complete all as specified and directed. NOTE : thickness after punning of sand shall be (minimum as specified in SSR) measured and paid in this item. |
| 25 | Material and labour for brick protection for UG XLPE cable with burnt clay old size sub class \"B\" bricks laid dry and flat abutting each other with gaps between adjacent brick not more than 10mm and width equal to length of brick in trenches across the cable complete all as directed by Engineer-In-Charge.Make: Best quality locally available which is duly approved by GE. |
| 26 | M & L for earthing complete with galvanised earth plate 60 cm X 60 cm X 6.00 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to connected to galvanised iron strip 32x6mm as earthinglead by means by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of earth wire and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI/CI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 3 on srl page No 497 of SSR Part I (2009)drawing and connection to earth test point including testing complete all as specified and directed.Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate.(ii)The cost of excavation, earth work is included in the quoted rate. |
| 27 | Supply,Fabrication,installation including testing & commissioning of LT motor/starter panel Indoor Type,IP-43,suitable dimension upto1500X1200X450 MM,CPRI approved of suitable size made out of MS sheet 2mm thick and angle iron 40x40x6 mm factory made weather proof/vermin proof (double door) totally enclosed front and backopenable padestal type with suitable locking arrangements and coating with polystrene/epoxy powder over a coat of zinc chromate and comprising of following items complete with rubber gland for proper closing of panels all as specified and directed by Engr-in-Charge. (a) Copper busbar suitable for three phase four wire system of current rating 300/400 Amps and insulated with proper colour coding-01set.(b) MCCB Four Pole of capacity 160-200Amps withthermal release type with O/l and S/C protection and rupturing capacity 35 KA- 01 No (Incomer). (c) MCCB TP 415 volts current rating 63 amps and rupturing capacity 25 KA - 02 No (Out going). (d) Fully autromatic star delta starter push button type air break suitable for elctric motor 3 Phase 50 HZ 415 volts of capacity upto 25/30 HP with relay, single phase preventor complete without encloser - 02 Nos.(e) Digital volt meter of range 0-500 volts off size of 96 mm squre with selector switch -01 No.(f) Digital Ameter of range 0-500 Amps of size 96 sq mm square with suitable Ct,s coil and selector switch -01 No (01 Nos Incomer + 02 Nos Outgoing).(g) Indicator lamp LED type - Set of three.(h) Single phase preventor - 02 Nos(k) Motor protection relay -02 No.Note : Rate includes dismantling of surface and fixing of panels with required pcc, nuts and bolts etc. |
| 28 | Supply and laying, connecting, testing, commissioning HT UG cable XLPE Insulated, armoured,electric powercables (heavy duty) 11 KV grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 120 Sqmm 3.0 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc.including taking out old unserviceable cable all as directed by Engr-In-Charge.Make: Polycab(ISI Marked)/ Finolex(ISI Marked)/ Havells (ISI Marked)/ Gloster (ISI Marked)/ KEI (ISI Marked)Note:-(a) Excavation, sand cushioning, bricks, GI Pipe laying shall be measured and paid separately. |
| 29 | Supplying and laying un-reinforced precast concrete cable cover, class HVP,type 1 with peak, size 300 mm x 180 mm x 40 mm complete all as specified. |
| 30 | Supply and fix for 100 mm bore tubes \"light grade\" galvanised with all fittings laid in trenches of complete all as specified and directed by Engineer-In-Charge.Note :- Excavation & earth work shall be measured and paid separately under respective items of this schedule. Make : Tata / Jindal Steel / Prakash/ Surya Roshni ltd |
| 31 | Material and labour for heat shrinkable indoor type end termination jointing kit for HT 11000 Volts (Earthed) grade cable of 120 Sqmm 3 core size complete with jointing material and accessories complete all as directed by Engineer-In-Charge.Make: M-Seal/ Cab-Seal/ Denson/ Raychem/ Birla 3M |
| 32 | Material and labour for outdoor type heatshrinkable cable end termination jointing kitfor HT 11000 Volts (Earthed) grade cable of 120 Sqmm 3 core size complete with jointing material and accessories complete all as directed by Engineer-In-Charge.Make: M-Seal/ Cab-Seal/ Denson/ Raychem/ Birla 3M |
| 33 | Material and labour for heat shrinkable outdoor type straight through jointing kit for HT 11000 Volts (Earthed) grade cable of 120 sqmm 3 core size complete with jointing material and accessories complete all as directed by Engineer-In-Charge.Make: M-Seal/ Cab-Seal/ Denson/ Raychem/ Birla 3M |
| 34 | Material and labour for ACSR conductors suitable for 11 KV HT with all connected connectors and lugs complete all as directed by Engineer-In-Charge. |
| 35 | M&L for horizontal boring for 100mm bore GI pipe under road/pavement/hard standing at 0.9m to 1.5 m depth from top of road level and insert 100mm medium GI for Laying XLPE UG Cable with all necessary fittings and without any damage of road/pavement/hard standing surface complete all as specified and directed.Note :- (i) Necessary earth work shall be carried out and the cost for the same shall be included in the rate quoted for this item. |