| 1 | M&L Removing Complaint of Blockage (viz Blockage in Bath, Kitchen, WC & Drainage in Traps/Line from Trap to 1st Manhole, Blockage in Sewage Line from 1st Manhole to Septic Tank, Cleaning of Manhole) by deploying Trades Men as per Stipulated Time Frame from 9.00 AM to 5.00 PM (Complaints as per MES Complaint register), complete all as specified and as directed. |
| 2 | M&L Clearning Choked Sewer Lines of 100 mm dia and over upto any depth, Manually or thorough Mechanical Appliances and Making Sewer Line Functional complete including Working Under Foul Condition and depositing the sludge, rubbish, etc. off the Premises outside the MOD/AF Land or Sewage Treatment Plant, complete all as specified and as directed. |
| 3 | M&L Removing Manhole Cover and Desludging/Desilting/Cleaning of existing Manholes of varying depth filled with Sludge by means of Manually or through Mechanical Appliances complete, Working Under Foul Condition and resetting the Manholes Cover in same Position and depositing and removal of Sludge, Rubbish, etc. off the Premises Outside Defence Land, complete all as specified and as directed. |
| 4 | M&L Dewatering Sludge from Soakage Wells by Pumping out as required to keep the Complete Sewage System in order and as to avoid any Over flowing of Sewage Water including removing of Soak Well water pumped out as such out side of Defence Land by means of Pumps and Tankers (Capacity of Water Tanker shall be 5000 Litres) as required including Operating and Supervisory Staff(s) so as to keep the whole Station area Pollution Free, complete all as specified and as directed.NOTE : Each Trip of Tanker to be taken Out side of MOD/AF Land in presence of JE in-Charge.This includes deployment of necessary T&P and nothing shall be Paid Extra. |
| 5 | Cleaning of Sewage pipe line (RCC/SGSW) of Upto 300mm bore by means of sewage cleaning jet machine /Super sucker machine and clean out the sluge /liquid mud or any other obstruction material to any depth including nesesarry rodding, working in foul position and depositing of sludge/silt/liquid mud beyond the premises of MOD land etc complete with all specified pressure rating and complete all as directed by Enge-in-charge.Note :- All other arrangment of electricity, water, etc included in quoted cost.Also the jet machine/super sucker machine to be deployed and work for atleast 8 hours in oneday incl atleast 05 person of labour to carry out neccessary cleaning of manhole/sewer line at the time of deployment of machine in the station. |
| 6 | Cleaning of Sewage pipe line (RCC/SGSW) of Upto 300mm bore by means of sewage cleaning jet machine /Super sucker machine and clean out the sluge /liquid mud or any other obstruction material to any depth including nesesarry rodding, working in foul position and depositing of sludge/silt/liquid mud beyond the premises of MOD land etc complete with all specified pressure rating and complete all as directed by Enge-in-charge.Note :- All other arrangment of electricity, water, etc included in quoted cost.Also the jet machine/super sucker machine to be deployed and work for atleast 8 hours in oneday incl atleast 05 person of labour to carry out neccessary cleaning of manhole/sewer line at the time of deployment of machine in the station. |
| 7 | Taking down PVC (SWR) pipesof any description with fitting and making good to disterbed surfaces complete all as specified and directed. |
| 8 | S&F in repair 110mm bore PVC(SWR) pipes single socketed in any lengthpressure rating 4Kg/Sq cmmedium Grade fixed to walls or laid to floor or trenches with dash through nut and bolt at every 2mtr length including)includingall fittings complete all as specified and directed by Engineer-in-charge.Notes : The Area includes in this items to working in shaft portion upto 6th storied building. |
| 9 | S&F in repair 75mm bore PVC(SWR) pipes single socketed Pressure rating @4Kg/Sq cm medium grade in any length with rubber ring joint, fixed to walls or laid in floor or trenches including taking down eaves, gutters rain water pipes (any size or pattern) including all fittings(Tee, elbow etc) complete all as specified and directed by Engineer-in-charge.Notes : The Area includes in this items to working in shaft portion upto 6th storied building. |
| 10 | S&F in repair75mm bore PVC (SWR) bends any radius With or without access door complete all as specified and directed by Engr-in-charge. |
| 11 | All as per item no 10 but 100 mm bore -ditto-. |
| 12 | S&F in repair100 mm bore PVC (SWR) bends any radius With or without access door complete all as specified and directed by Engr-in-charge. |
| 13 | Taking up or down Steel Tubing 25mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.Notes : The Area includes in this items to working in shaft portion upto 6th storied building. |
| 14 | S&F in repair 25 mm bore dia galvanized steel tubes medium grade with all fittings laid concealed in walls including cutting through wall, floors, etc and their making good, complete all as specified and direced. |
| 15 | Excavation in trenches n.exc 1.50 m wide and n.exc 1.50 m in depth for foundation or shafts,wells,cesspits, manholes,pier holes,cable laying,sewage/water lines etc complete and getting outin soft/loose soil complete all as specified and directed. |
| 16 | Demolition and breaking of drain pipes of 150 mm dia (Salt galzed ware, AC or Reinforced concrete set in cement mortar etc complete all asdirected |
| 17 | Demolition and breaking of drain pipes of 200 mm dia (Salt galzed ware, AC or Reinforced concrete set in cement mortar etc complete all asdirected |
| 18 | Demolition and breaking of drain pipes of 100 mm dia (Salt galzed ware, AC or Reinforced concrete set in cement mortar etc complete all asdirected |
| 19 | M&L for double wall corrugated drain pipes of 150 mm dia bore class SN-8, laid and jointed using rubber ring joints complete with collars etc complete all as specified and as directed. |
| 20 | M&L for double wall corrugated drain pipes of 200 mm dia bore class SN-8, laid and jointed using rubber ring joints complete with collars etc complete all as specified and as directed. |
| 21 | M&L for double wall corrugated drain pipes of 100 mm dia bore class SN-8, laid and jointed using rubber ring joints complete with collars etc complete all as specified and as directed. |
| 22 | Returning filling in including spreading leveling watering and well ramming in layer not exc 25cm thick comple all as specified and directed.. |
| 23 | Removal of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.50 mtr above the starting point complete all as specified. |
| 24 | Demolition of cement concrete (reinforced) in any description and in any postion not otherwise specifically provided for etc complete all as directed |
| 25 | M&L for Pre-Cast reinforced cement concrete 1:2:4 type B-1 with using 20 mm gradedcrushed stone aggregates as in cover slabs (for manholes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plan faces set in cement mortar (1:4) including necessary use and waste form work etc complete all as specified and as directedNote - Reinforcement shall be measured and paid separetly |
| 26 | M&L for TMT bars upto 10mm diaas in reinforcement for concrete, cut to length, bent to shape required including cranking , bending spiraly for hooping for columns, hooking with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and as directed |
| 27 | Taking down cement plaster of any description on brickwalls, etc including raking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed. |
| 28 | Rendering 15 mm thick on brickor concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement, complete all as specified and directed. |
| 29 | Demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 30 | Demolition of cement Concrete/lime concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 31 | Dismantling floor, hearth or any type of tiling including cement mortar bedding (but not backing), removing serviceable tiles from site and rubbish off the premise complete all as specified and directed. |
| 32 | M&L Non skid coloured ceramic tiles area of each tileexceeding 0.06 Sqm and n exc 0.11 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick Screed bed or bedding layer of mortar for lying floor finished in Cement Mortar 1:4 complete all as specified and directed. |
| 33 | M&L Glazed coloured ceramic tiles in vertical surfaces 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surface as backing coat coat of dado/skirting etc complete all as specified and as directed . (Notes : rates are inclusive of taking down doors/fittings and refixing it.) |
| 34 | S&F Vitreous China White Wash Down Water Closet Pan (orissa pattern) size suitable at site with Trap and Fixing Bolts and Making Good to Floor/ distrubed surfaces and fixed-in-repairs with PVC flushing cistern of 10 ltr, complete all as specified and as directed. |
| 35 | M&L for plain cement concrete1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in bed of drain foundation, filling and mass concrete complete all as specified and directed. |
| 36 | M&L for Brick work with sub class \"B\" Old size bricks, straight or curved on plan to any radius in cement mortar (1:4) as in half brick wall and pointed flush in same mortar as work proceeds on one side complete all as specified. |
| 37 | M&L Brick work with sub class ‘B’ bricks(old size brick), straight or curved on plan exc 6 mtr mean radius built in cement mortar (1:4) and external face of brick work pointed flush in the same mortar as the work proceeds, complete all as specified and as directed |
| 38 | M&L Brick work with sub class ‘B’ bricks(old size brick), straight or curved on plan exc 6 mtr mean radius built in cement mortar (1:4) and external face of brick work pointed flush in the same mortar as the work proceeds except bricks, complete all as specified and as directed |
| 39 | M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone agggregate as in surface channel drain and bedding including necessary form work and weathering, slightly rounded or chemfered angles complete all as specified and directed. |
| 40 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds,mitred/stoppedends etc complete all as specified and as directed |
| 41 | M&L for plain cement concrete 1:2:4 type, B1 (using 20 mm graded crushedstone aggregates) as in copings including necessary use and waste offormwork, weathering, slightly rounded or chamfered angles and throating etc complete all as specified and as directed |
| 42 | M&L preparing old/newDecorated/Treated Plastered surfaces of Wallsby brooming down or steel wire brushing and scraping downand applying one or more(as required) Coats of Weather Coat Exterior Paint (in Camuflage/Plain pattern as ordered) with approved Tint(as per Manufacturer\"s instructions), complete all as specified and as directed. |
| 43 | Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness ( below or above ground level) and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas complete all as specified and directed. |
| 44 | M&L for 40mm thick PCC 1:2:4 type D-2 (using 40mm graded stone aggregate) in sub base of floor or as in floor complete all as specified and as directed . |
| 45 | M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in sub base of floor or plinth protection complete all as specified and as directed . |
| 46 | M&L for Machine Pressed, Glossy finish Pre-Cast concrete interlocking coloured paver block of glass fibre reinforced vibro compacted any shape and size conforming to IS-15658:2006 of 60mm thickness made with M35 grade concrete match with grey cement and pigment etc including 20 mm thick sand cushioning complete all as specified and directed. |
| 47 | M&L for exterior grade coloured, glossy finished, rubber pressed precast chequered cement concrete tiles 30cmx30cmx25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments complete including 20 mm thick sand cushioning all as specified and directed |
| 48 | M&Lfor preparation of old concrete surface of kerb stone and applying Two coat of synthetic enamel paint etc complete all as specified and as directed |
| 49 | M&L for Rough cast plaster on brick walls consisting crushed stone or fine gravel mixed of size 6mm with coarse sand and cement in the ratio 1:1:1 shall be applied and finish even completed all as specified &directed by Engr-in-charge. |
| 50 | M& L preparing newly for rough cast plastered/ newly platered surfaces of walls and applying two coat of arcylic weather coat exterior paint ( with approved tint in camouflage/plain pattern as directed) over a coat of primer ( as per manufacturer\"s instruction) all as specified and directed. |
| 51 | M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate asin floor 40 mm thick finishing the surface without using extra cement |
| 52 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded aggregates) as in foundation and mass concrete etc complete all as specified and directed |
| 53 | Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed. |
| 54 | S&F MS framed work such as grills, gratings etc with ends of bars shouldered and or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walk way railing grame work of wastertanks and similar work confiming to Fe.290, Gde E-165 etc complete all as specified and as directed |
| 55 | Dismantling post or struts (wood, steel or RCC) any section including taking out embedded portion and making good disturbed ground posts embedded in natural ground complete all as directed. |
| 56 | Earth work excavation in post holes ( or similar holes) in soft / loose soil ,each not exceeding 0.50 Cum ,getting out ,returning filling in and ramming earth or broken rubble mixed with earth around ,in layers not exceeding 25 cm ,watering and removing surplus soil complete all as specified and directed. |
| 57 | S&F Framed mild steel work as in posts/ struts in fencingincluding cutting tops to shape, drilling holes,bolting,rivetting flatetc. complete conforming to Fe-290 gde E165 complete all as specified and directed. |
| 58 | S&F Framed mild steel work as in gates including pintel hinges, stops, hand made sliding bolts etc. complete conforming to Fe-410-0 or Fe-310-0 complete all as specified and directed. |
| 59 | S&F 8 mm dia and over Machine made MS screw bolts with hexagonal or square head at one end and screwed the other each screwed end to be fitted with washers and one hexagonal nut exc 5and notexc 10 cm long complete all as specified and directed. |
| 60 | S & F for 8 mm dia or over MS bars as in strainers forchain link fencing including necessasary welding and fixing to angle iron complete all as specified and directed. |
| 61 | Dismantling fencing wire mesh, any type etc complete all as specified and directed |
| 62 | Fixing only chain link fencingincludingline wires, any mesh, size and any type of standards, rails, straining bolts etc. complete all as specified and directed. |
| 63 | S & F in repair galvanised 2 strand steel barbed wire 2 mm dia barbed with 2.3 mm dia barbs at 75 to 80 mm spacing and straining, fixed to fencing post tieing at crossing with and including galvanised mild steel wire complete all as specified and directed. |
| 64 | Supply only Chain link MS galvanised fencing , any size or type complete all as specified and directed. |
| 65 | Preparation ofold painted steel surfaces of any description over 10 cm width or girthand applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 66 | Preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 67 | S&F 30-35 mm thick GRC/GFRC Jali by drilling or patching it in walls/RCC Columns including dismantling old RCC jali all as specified anddirected |
| 68 | M&Lfor PCC 1:3:6 type C1using 20mm graded stone aggregate, 75 mm thick as in plinth protection finished even and fair without using extra cement complete all as specified and directed. |
| 69 | M&L for 25 mm thick precast chequeredtiles glossy finish of size 300 x 300 mm, coloured, pre-polished, set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles, as in floor, laid over and including 20mm thick screed bed i, all as specified and as directed. |
| 70 | M&L for 1.00 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed. |
| 71 | S&F in repair Steel rolling shutters 1.25 mm laths, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete with all necessary fittings all as specified and directed |
| 72 | M&L Repairs/Maintenance of Steel Gate/ Collapsible Gate( of any size), Oiling/ Greasing of all Moving Parts of the Gate and making Serviceable for Free Movement of Gate including replacement/adjustment, welding, drilling, etc. of all Minor Parts (viz Nuts, Bolts, Rods, Flat Iron, Angle Iron, Guide Rail, Ball Bearing, etc. of Steel Gate including Taking down and Re-fixing Steel Gate wherever necessary, complete all as specified and as directed. |
| 73 | M&L Taking down existing Steel Rolling Shutter including Hood Cover, Pull and Push type, area not exc. 8.0 Sqm Each, Sides of clear Opening and Cleaning the Side of Shutter Suspension Shafts, Anti-guide Channels and Greasing all the Moving Parts of the Rolling Shutter and straightening Rolling Shafts and replacement of Bolts, Nut, etc. as required for Smooth Functioning of Shutter and Re-fixing the same including Hood Cover, complete all as specified and as directed. |
| 74 | Supply, fabrication and fixing of stainless steel 304 grade letters including vowels smooth finish as per sample provided (Hindi/ English) on granite wall/Steel sheet made out of 1 mm thick stainless steel sheet (minimun size not less than 40mm thick, 40mm in width and 300 mm high) and 10 mm dia, 75mm long MS studs weld with back side of letters as per site requirement fix on granite wall/Steel sheet making holes by drilling machine and studs fix with epoxy adhesive/nut bolts complete all as directed by Engr-in-Charge. |
| 75 | Dismantling of plain or corrugated steel sheeting or mangalore tile roof any guage, thickness from roof covering complete all as specified and directed. |
| 76 | S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screwscomplete all as specified and as directed. |
| 77 | S&Fstructural steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. .Fe-410- W(Gde E-250)quality-B complete all as specified and as directed. |
| 78 | S & F in repair hot dipped galvanised concertina razer tape coil 1020 mm dia, spring steel high tensile centre core wire 2.5 mm dia having 200-250gm zinc coating, 0.5 mm thick razer sheethaving 90-120gm, zinc coating & min 10 mm width ( before wraping centre core wire),with GI clip 1.6 mm thick complete all as specified and directed. |
| 79 | M&L for preparing old plastered surafce of wall for finishing with acrylic smooth exterior paint of required shade upto two storey of two or more coat applied @1.67ltr / 10 sqm over a coat of primer all as specified and directed |
| 80 | Preparing Old Treated/Painted Steel and Iron Surfaces of any description, and applying Two Coat of Synthetic Enamel Paint (First quality) for Y shape Mild steel Angle Frame( area exc 0.25 Sqm but not exc 0.50 Sqm Each) fixed on boundary walls (Straining /Supported to barbed Wire and Concertina Coil) complete all as specified and as directed. |