}

Supplying Installation Testing & Commissioning Of Ups System And Its Related Items At Regional Fsl Building At Darjipura, Dist:-Vadodara. (Priority 2022-23 Home Department) [5Th Attempt], Vadodara-Gujarat

Gujarat State Police Housing Corporation Limited has published Supplying Installation Testing & Commissioning Of Ups System And Its Related Items At Regional Fsl Building At Darjipura, Dist:-Vadodara. (Priority 2022-23 Home Department) [5Th Attempt]. Submission Date for this Tender is 16-01-2025. UPS Tenders in Vadodara Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

47049701
Supplying Installation Testing & Commissioning Of Ups System And Its Related Items At Regional Fsl Building At Darjipura, Dist:-Vadodara. (Priority 2022-23 Home Department) [5Th Attempt]
Open Tender
Indian
Gujarat
Vadodara
16-01-2025

Tender Details

Supplying Installation Testing & Commissioning Of Ups System And Its Related Items At Regional Fsl Building At Darjipura, Dist:-Vadodara. (Priority 2022-23 Home Department) [5Th Attempt]-Supplying and erecting approved make online Un-interruptible Power Supply system with IGBT Based rectifer and Inverter & sealed maintenance free batteries. Three phase Input and Three Phase output with Inbuilt Isolation transformer with 0.9 load power factor with battery, over under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following capacity & with required size and no of batteries for 1 hr Backup with Battery bank rack . For 10 KVA UPS . . (Make: APC / Socomec / Numeric make and model approved by EIC) Certification : BIS Rates are included 2 years standard ups warranty and battery bank. this warranty period includes UPS routine serive as per OEM Guideline and replacment of any parts damaged/failed to operate due to any reason. Agency must be replaced it within 2 days and shall make UPS in working condition. Also each battery of battey bank is gauranteed for replacement in case found faulty upto 2 years after commissioning. ( Battery make - Exide /mircoteck / luminous ). Suppy, installation, testing and commisioningof New Battery bank bank having back up capacity of 60 minutes suitable for 10 kva ups.Each battery is gauranted for 2 years after commissioning. i.e if any battery is failed then it must be replaced within 2 days. Rates are included for removing of existing battery bank with it connections and handing over to benificiary. Agency has to also provide the fitness certificate from battery manufacturer/Dealer and submit to G.S.P.H.C.L. Agency has to submit FDR of approved bank as per clause 2.0, section 3, of Rs. 12,05,864.00 or quoted amount whichever is higher to G.S.P.H.C.L. for minimum maturity period of Four years in favour of GSPHC, Which will be released after successful completion of 2 year gaurantee period & at the and of defect liability period. new battery bank Make , model and AH capcity and Nos must be as per replaced Battery bank only. All-in-all AMC charges after completetion no Two years from handing over project For 10 KVA Ups.Executing comprehensive (All-in-All) service & manitenance with spare parts as per terms & condition of tender for defect liability period by UPS manufacturer. For that main agency has togive All-in-All comprehensive maintenance contract to UPS manufacturer and copy of this contract will be submitted before final bill. Agency has to quote rate accordingly. Agency has to also provide the fitness certificate from UPS manufacturer and submit to G.S.P.H.C.L. Agency has to submit FDR of approved bank as per clause 2.0, section 3, of Rs.1,62,840.00 or quoted amount whichever is higher to G.S.P.H.C.L. for minimum maturity period of Four years in favour of GSPHC, Which will be released after successful completion of AMC & at the and of defect liability period. UPS OEM has to mantain written record of service & maintenance during defect liability daily period duly sigh by FSL. and submited regularly to GSPHCL. UPS Agency has to check all UPS input voltage, output voltage , , load current , protection system , switch over time on battery and BATTERY back up of 1 hour at the time of SD release and confirm with G.S.P.H.C.L. engineer and beneficiary. If required agency has to replace parts /cards in UPS and make it healthy working condition upto defect liability period. UPS agency has to do maintanance as per terms & condition altarenet in tender. Also UPS OEM agency should have proper dress code or identity card during any work ralated to UPS due to safety reasons For delay in rectifing the fault, penalty will be deduced from agency own risk and cost from S.D. Whenever agency applied for final SD to be released to department , agnecy must submit UPS OEM fittness certificate. No any additional payment will be given for UPS fitness certificate. Supplying and erecting approved make online Un-interruptible Power Supply system with IGBT Based rectifer and Inverter & sealed maintenance free batteries. Three phase Input and Three Phase output with Inbuilt Isolation transformer with 0.9 load power factor with battery, over under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following capacity & with required size and no of batteries for 1 hr Backup with Battery bank rack . For 20 KVA UPS . . (Make: APC / Socomec / Numeric make and model approved by EIC) Certification : BIS Rates are included 2 years standard ups warranty and battery bank. this warranty period includes UPS routine serive as per OEM Guideline and replacment of any parts damaged/failed to operate due to any reason. Agency must be replaced it within 2 days and shall make UPS in working condition. Also each battery of battey bank is gauranteed for replacement in case found faulty upto 2 years after commissioning. ( Battery make - Exide /mircoteck / luminous ). Suppy, installation, testing and commisioningof New Battery bank bank having back up capacity of 60 minutes suitable for 20 kva ups.Each battery is gauranted for 2 years after commissioning. i.e if any battery is failed then it must be replaced within 2 days. Rates are included for removing of existing battery bank with it connections and handing over to benificiary. Agency has to also provide the fitness certificate from battery manufacturer/Dealer and submit to G.S.P.H.C.L. Agency has to submit FDR of approved bank as per clause 2.0, section 3, of Rs. 2,81,152.00 or quoted amount whichever is higher to G.S.P.H.C.L. for minimum maturity period of Four years in favour of GSPHC, Which will be released after successful completion of 2 year gaurantee period & at the and of defect liability period. new battery bank Make , model and AH capcity and Nos must be as per replaced Battery bank only. All-in-all AMC charges after completetion nof Two years from handing over project For 20 KVA Ups.Executing comprehensive (All-in-All) service & manitenance with spare parts as per terms & condition of tender for defect liability period by UPS manufacturer. For that main agency has togive Allin- All comprehensive maintenance contract to UPS manufacturer and copy of this contract will be submitted before final bill. Agency has to quote rate accordingly. Agency has to also provide the fitness certificate from UPS manufacturer and submit to G.S.P.H.C.L. Agency has to submit FDR of approved bank as per clause 2.0, section 3, of Rs.35282.00 or quoted amount whichever is higher to G.S.P.H.C.L. for minimum maturity period of Four years in favour of GSPHC, Which will be released after successful completion of AMC & at the and of defect liability period. UPS OEM has to mantain written record of service & maintenance during defect liability daily period duly sigh by FSL. and submited regularly to GSPHCL . UPS Agency has to check all UPS input voltage, output voltage , , load current , protection system , switch over time on battery and BATTERY back up of 1 hour at the time of SD release and confirm with G.S.P.H.C.L. engineer and beneficiary. If required agency has to replace parts /cards in UPS and make it healthy working condition upto defect liability period. UPS agency has to do maintanance as per terms & condition altarenet in tender. Also UPS OEM agency should have proper dress code or identity card during any work ralated to UPS due to safety reasons For delay in rectifing the fault, penalty will be deduced from agency own risk and cost from S.D. Whenever agency applied for final SD to be released to department , agnecy must submit UPS OEM fittness certificate. No any additional payment will be given for UPS fitness certificate. Supplying and erecting approved make online Un-interruptible Power Supply system with IGBT Based rectifer and Inverter & sealed maintenance free batteries. Three phase Input and Three Phase output with Inbuilt Isolation transformer with 0.9 load power factor with battery, over under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following capacity & with required size and no of batteries for 1 hr Backup with Battery bank rack . For 30 KVA UPS . . (Make: APC / Socomec / Numeric or equivalent make and model approved by EIC only) Certification : BIS Rates are included 2 years standard ups warranty and battery bank. this warranty period includes UPS routine serive as per OEM Guideline and replacment of any parts damaged/failed to operate due to any reason. Agency must be replaced it within 2 days and shall make UPS in working condition. Also each battery of battey bank is gauranteed for replacement in case found faulty upto 2 years after commissioning. ( Battery make - Exide /mircoteck / luminous ). Suppy, installation, testing and commisioningof New Battery bank bank having back up capacity of 60 minutes suitable for 30 kva ups.Each battery is gauranted for 2 years after commissioning. i.e if any battery is failed then it must be replaced within 2 days. Rates are included for removing of existing battery bank with it connections and handing over to benificiary. Agency has to also provide the fitness certificate from battery manufacturer/Dealer and submit to G.S.P.H.C.L. Agency has to submit FDR of approved bank as per clause 2.0, section 3, of Rs.4,39,834.00 or quoted amount whichever is higher to G.S.P.H.C.L. for minimum maturity period of Four years in favour of GSPHC, Which will be released after successful completion of 2 year gaurantee period & at the and of defect liability period. new battery bank Make , model and AH capcity and Nos must be as per replaced Battery bank only. All-in-all AMC charges after completetion nof Two years from handing over project For 30 KVA Ups.Executing comprehensive (All-in-All) service & manitenance with spare parts as per terms & condition of tender for defect liability period by UPS manufacturer. For that main agency has togive All-in-All comprehensive maintenance contract to UPS manufacturer and copy of this contract will be submitted before final bill. Agency has to quote rate accordingly. Agency has to also provide the fitness certificate from UPS manufacturer and submit to G.S.P.H.C.L. Agency has to submit FDR of approved bank as per clause 2.0, section 3, of Rs.51566.00 or quoted amount whichever is higher to G.S.P.H.C.L. for minimum maturity period of Four years in favour of GSPHC, Which will be released after successful completion of AMC & at the and of defect liability period. UPS OEM has to mantain written record of service & maintenance during defect liability daily period duly sigh by FSL. and submited regularly to GSPHCL. UPS Agency has to check all UPS input voltage, output voltage , , load current , protection system , switch over time on battery and BATTERY back up of 1 hour at the time of SD release and confirm with G.S.P.H.C.L. engineer and beneficiary. If required agency has to replace parts /cards in UPS and make it healthy working condition upto defect liability period. UPS agency has to do maintanance as per terms & condition altarenet in tender. Also UPS OEM agency should have proper dress code or identity card during any work ralated to UPS due to safety reasons For delay in rectifing the fault, penalty will be deduced from agency own risk and cost from S.D. Whenever agency applied for final SD to be released to department , agnecy must submit UPS OEM fittness certificate. No any additional payment will be given for UPS fitness certificate. Providing & Erecting Mains with ISI marked, 1.1 KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS:694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. For 35.00 Sq.mm For One wire 25.00 sq. mm For One wire 16.00 Sq.mm Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid material with ignition free & flame proof confirming BS with necessary end caps Internal and external bend, flat bends, coupler, tee etc. All necessary accessories and measuring of following sizes. [1] 50 mm x 50 mm trunking (MK /Legrand/OBO Make Only) 100 mm x 50 mm trunking r (MK /Legrand/OBO Make Only) Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board having IP42 & above protection as per require made from 2 mm. thick CRC M.S. sheet for outer body & doors, 1.5 mm. thick CRC M.S. sheet for internal partitions with necessary supporting angles, flats including skirting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-In-Charge with erection of supplied switchgears, busbars with suitable size of interconnecting PVC copper wire / Copper- Aluminium strips, rubber gromets, rib, control wires, backelite control fuses, measuring instruments, earth bus & earth bolts, foundation flange-bolts-base plates, sufficient nos. of hinged doors, handle with locking arrangement, rubber gasket complete with Required Nos. heavy Duty Connector. heavy duty end terminal connection,danger notice board,necessary ventilation,earthing strip complete.The panel shall be supplied with Seven Tank chemical process which shall be carried out before applying painting, painted with powder coating. (The rates excludes the cost of switchgears, busbars, interconnecting mains & Copper / Aluminium strip, fuse, meters etc. The dimension shall be measured excluding base beams) Factory inspection for verification of quality,workmanship and as per drawing & testing before dispatch the material as per tender condition. The standard companies switch gear shall be used and only manufacturers at CPRI approved factory as per IEC 61439 and shall be certified by that company whose switch gears are used after fabrication for beneficial use. With 350 mm depth Panel manufacturer have to give 3 years maintenance and service support if in case of breakdown or fault. Panel manufacturer have to submit electrical meter calibration report. Agency should design the panel in such a way that there should not be any excess in panel area (sq.mtr) & length of bus bar (mtr), if any excess occurs draw attention to GSPHCL at the time of approval of G.A. drawing. Loading and unloading of above item shall be done by hydra and skill work force under supervision of electrical engineer and guidelines given by manufacturer to avoid damage to the item. Picture of it to be submitted in running bill / final bill. Size of door and Ele. room / Pump room shall be checked by agencys engineer before giving order. If found any problem in size discuss with GSPHCL engineer for rectification before giving order. [Including Necessary numbering / marking on PANEL done with red colour radium sticker as per site requirement and instructions given by EIC on site. Font / number size given by EIC on site as per requirement] Supplying and erecting tripple pole & neutral 440V / 500 V Panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current / cross section area) duly wraped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports / insulators, main cable socket to each bar, erected in existing cubical panel with necessary connections.For electrolyte copper busbars Suitable for 100 Amp. capacity Suitable for 200 Amp. capacity Providing & Erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 K.A. at 415 V. having normal current rating 125A. with Fixed/Variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only Providing & Erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 K.A. at 415 V, having normal current rating 25 A to 100 A. with Variable/Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only No. 16 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity [c] 63 Amp. 17 Providing & Erecting Approved make ISI mark ELCB confirming to IS:12640/1988 having sensitivity of 30 mA and breaking capacity of 10 KA and suitable for 240/415 having characteristic of quick acting & Tripping with all advance feature & do not incorporate any electronic component (mounted in three phase MCBDB for phase isolation) Suitable for operation on single phase 240 Volt max rating of (i) For 40 Amp. DP 18 Supplying, erecting, testing and commissioning of approved make panel mounting type Digital Voltmeter having 3 digits LED display 0 to 750 AC Volts range having 0.5 Class accuracy erected on existing panel board with all connection, wiring ete., with manufacturers calibration certificate. 19 Supplying, erecting, testing and commissioning of approved make panel mounting type Digital Ammeter having 3 digits LED display, external CT operated, calibrated for 0 to 400 Amps. suitable operate on 500 volt AC having 0.5 Class accuracy erected on existing panel board with all connection wiring ete., with manufacturers calibration certificate. 20 Supplying and erecting Ammeter / Voltmeter selector switch for 3 phase AC Supply 500 V on existing panel board with necessary connections. 21 Supplying and erecting approved make set of indicator lamps of LED type lamp, lense cover, Bakelite holder complete erected with necessary connections. 22 Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15 VA burden 0.5 class accuracy erected in existing CRCA box duly secured with insulating materials connected to the meter

Key Value

Document Fees
INR 1500 /-
EMD
INR 45852.0 /-
Tender Value
INR 45.49 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail