| 1 | Repairs of Refrigerators/ D-Frizzier (50 Machines) |
| 2 | Compressor replacement by its original manufacturer item |
| 3 | Gas charging with Nitrogen pressure testing and evaluation. |
| 4 | Replacement of relay with testing its cooling performance. |
| 5 | Replacement of gasket set. |
| 6 | Replacement of strainer and capillary. |
| 7 | Replacement of thermostat. |
| 8 | Replacement of fan Motor Refrigerator |
| 9 | Compressor for Refrigerator |
| 10 | Compressor for D-Frizzier |
| 11 | Replacement of Freeger Coil for Refrigerator |
| 12 | Replacement of fan motor D-Frizzier. |
| 13 | Replacement of Drier / Filter |
| 14 | Spray Painting with complete unit by dismantling and re-erection |
| 15 | Compressor replacement for Refregerator upto 220 ltr. |
| 16 | Compressor replacement for Refregerator upto 350 ltr. |
| 17 | Compressor replacement for D frizzerupto 350 ltr. |
| 18 | Compressor replacement for D frizzerabove 350 ltr. |
| 19 | Gasket set for D-Frizzer |
| 20 | Gasket set for D-Refregerator |
| 21 | Replacement of fan blade for D-frezzer |
| 22 | Repairs of split type Air Conditioner (390Machines) Voltas, Blue star, Videocon, carrier etc |
| 23 | Replacement of compressor by its original manufacturer item. |
| 24 | Wiring Checking & Repairing |
| 25 | Replacement of starting capacitor. |
| 26 | Replacement of running capacitor. |
| 27 | Replacement of thermostat switch. |
| 28 | Replacement of Air-filter. |
| 29 | Replacement of strainer and capillary. |
| 30 | Rewinding of fan motor with servicing. |
| 31 | Gas charging with Nitrogen pressure testing and evaluation the system. |
| 32 | Servicing, checking of its cooling performance. |
| 33 | Refrigeration pipe with standard work drain arrangement in PVC pipe |
| 34 | Drain pipe for Air-Conditioner machine. |
| 35 | Outdoor unit fan motor blade. |
| 36 | Replacement ofPCB |
| 37 | Replacement of Outdoor Fan Motor |
| 38 | Dismantling and Re Installation of Split A.C. |
| 39 | Installation of Split A.C. |
| 40 | Replacement of Contactor 240 volt |
| 41 | Replacement of compressor 1.0 TR |
| 42 | Replacement of compressor 1.5 TR |
| 43 | Replacement of compressor 2.0 TR |
| 44 | Replacement of Indoor Unit Blower Motor |
| 45 | Repalcment of universal PCB |
| 46 | Repalcment of Air swing motor |
| 47 | Repalcment of oLP forComprossor |
| 48 | Repalcement fo Relay |
| 49 | Repalcemnent of evaporator coil |
| 50 | Replacement of Outdoor Unit Condensor Coil (Copper) |
| 51 | Replacement of Remote Handset |
| 52 | Laying of Copper Piping cable & Insulation for Suction & Discharge |
| 53 | Insulation of Suction & Discharge Copper Pipe |
| 54 | Replacement of Non-Return Valve for Suction & Discharge |
| 55 | MS Stand to Outdoor Unit |
| 56 | Replacement of Complete Outdoor Unit 1.0 TR |
| 57 | Replacement of Complete Outdoor Unit 1.5 TR |
| 58 | Replacement of Complete Outdoor Unit 2.0 TR |
| 59 | Replacement of Complete Indoor Unit 1.0 TR |
| 60 | Replacement of Complete Indoor Unit 1.5 TR |
| 61 | Replacement of Complete Indoor Unit 2.0 TR |
| 62 | Remote for any AC |
| 63 | Repair of window type Air Conditioner (50 Machines) |
| 64 | Replacement of compressor 1.0 TR |
| 65 | Replacement of compressor 1.5 TR |
| 66 | Replacement of compressor 2.0 TR |
| 67 | Wooden Frame for Installation of Window AC |
| 68 | Window Modification Grill Cutting, Glass Cutting and Fixing Window Frame etc. |
| 69 | Replacement of PCB Kit for Window AC |
| 70 | Replacement of relay unit. |
| 71 | Replacement of starting capacitor. |
| 72 | Replacement of running capacitor. |
| 73 | Replacement of thermostat unit. |
| 74 | Replacement of selector switch. |
| 75 | Replacement of over load protector. |
| 76 | Replacement of Air filter. |
| 77 | Rewinding of fan motor with servicing. |
| 78 | Gas charging with Nitrogen pressure testing and evaluation of complete system. |
| 79 | Servicing, checking of cooling performance with individual testing of components oiling of fan motor cleaning of complete components by air pressure blower by dismantling and assembling after servicing. |
| 80 | Erection of window mounted type room Air- Conditioner, fitting with 10 cms x 10 cms wooden frame grouted in races or fitted in window to required size with necessary material. |
| 81 | Repairs of water cooler (75 Machines) |
| 82 | Replacement of compressor 40/80 LTR |
| 83 | Replacement of compressor 60/120 LTR |
| 84 | Replacement of compressor 150/150 LTR |
| 85 | Replacement of Condensor Coil |
| 86 | Replacement of Drier / Filter |
| 87 | Replacement of Non Return Valve |
| 88 | Replacement of relay Unit |
| 89 | Replacement of OLP. |
| 90 | Replacement of running capacitor. |
| 91 | Replacement of starting capacitor. |
| 92 | Replacement of strainer and capillary. |
| 93 | Replacement of thermostat switch. |
| 94 | Replacement of drain tray. |
| 95 | Replacement of stain less steel water tap ½”. |
| 96 | Replacement of water filter |
| 97 | Replacement of gasket set. |
| 98 | Repairs of front/side/panel. |
| 99 | Spray painting with previous destroy and two coats painting. |
| 100 | Gas charging with Nitrogen pressure testing and evaluation the complete system. |
| 101 | Servicing wiring, checking of cooling performance with individual testing of components of complete unit. |
| 102 | Replacement of drain tray stain less steel |
| 103 | Replacement of front panel with top ½” and two side panel spray painting with previous destroy and two coat painting |
| 104 | Replacement of fan motor |
| 105 | Making hole with core cutting in stone wall |
| 106 | Civil work for concelling copper pipe, Drainpipe and cable etc. |
| 107 | Refflling the hole after Disementalling |