Tender For State Plan-Setting Up Of Effluent Quality Testing Lab At Kottayam District Procurement Of Additional Equipments.-Supply And Installation Of Equipments In Effluent Lab At Kottayam District-General Civil Work - OD247433/2023-2024:Supply and Installation of Microcontroller based Ph meter With 3 point calibration pH : Range :1 to 14 pH Resolution :0.01pH Stability : 0.01pH per hour Relative Accuracy : ±0.02pH ±1Digit Slope :85% to 115% Standard Buffers: 7 .000, 4 .000 ,9.183 ph Buffer Deviation :±0.2ph mV Range : 0 to ±1999.9mV Resolution : 0.1mV Accuracy : ±1 mV ± 1 Digit Temperature Compensation :Auto/Manual Range : 10°C to 99.9°C Resolution : 0.1°C Accuracy :±0.5°C±1 Digit Display : 7 segment 7 digit led Warranty: 1 year AMC: 2 year OEM should have service center in Kerala Bidder should submitminimum 5 performance certificate of different users in Kerala for the quoted model. 3 OD247434/2023-2024:Supply and Installation of BOD INCUBATOR Technical Specifications:- • Double walled construction, inner chamber stainless steel. • Inside full length observation glass/transparent door. • Size of Inner chamber approximately 50 x 60 x 50 cm. • Facility for adjustable shelves to convenient heights, 4-5 removable shelves ofstainless steel/anodized aluminum to be supplied. • Interior lighting facility, insulated door fitted with heavy hinges handle locking,mechanical door lock. • Microprocessor controlled. • Temperature ranges 5 to 60° with accuracy 0.5°C. • Independent temperature measuring through PT 100 sensor with indicator LCDdisplay. • Recovery time short, precise regulation of temperature and acoustic alarm. • Digital safety thermostat (class 3) • Audiovisual alarm and sensor to cut off supply in case of temperature malfunction. • Adjustable ventilation rate 10-100% thin form air circulation. • Environmental factors: The unit shall be capable of operating continuously ambient temperature of 10-45°C and relative humidity of 35-95% • Power supply:-Power input to be 220-240VAC, 50Hz. • Resettable over current breaker shall be fitted for protection. • Suitable UPS with maintenance free batteries for minimum one hour back-up shouldbe supplied with the system. • Warranty preferably 5 years. • Satisfactory working report of the quoted model from three reputed governmentinstitutes/hospitals should be included (within two years of submission of bid). • All equipments should specify Design qualifications, installation qualifications, and Operational Qualifications and Performance qualifications. Validation and calibrationreports should have traceability towards applicable national/internationals standards. • Original product catalogue should be provided by the firm. Necessary documents, technical write up in English shall be attached with the offer both in hard and soft copies. Performance, efficiency, others factors such as distortion etc. as applicable be also furnished. • Installation: the bidder must arrange for the equipment to be installed by certified or qualified personnel; any prerequisites for installation to be communicated to the laboratory in advance. Onsite, in lab customer training to be provided. The equipment should be supplied with 2 meter cord at input and fitted with plugs of appropriate rating (5/15 Amp.) 4 OD247435/2023-2024:Supply and Installation ofWATER BATH Technical specifications:- • Stainless steel SS304 chamber interior • Capacity: 15 litres • Temperature range: 30 to 99 degree C • Temperature Stability: ± 0.5 degree C • Dimension: (335 X 408 X 280) mm • RTD Temperature sensor • PID Temperature controller • Accurate temperature control • Over temperature protection • Thermostat equip with flowing water cooler • Should have safty feature including audible alarm, adjustable digitable overtemperature protection, low level detection and high temperature cut-off. • Warranty: Preferably5 years. 5 OD247454/2023-2024:Supply and Installation ofSingle Distillation Unit Capacity of distilled water output : 2.5LPH Heater :Quartz 6 OD247455/2023-2024:Supply and installation of Analytical Weighing Balance - Capacity :220g(maximum). Readability: 0.001g (1 mg). Repeatability: 0.001g. Max Linearity : ± 0.002g. Typical Stabilization Time: 2 Second or better. Leveling: Level indicator on front display unit and easy to adjust manually from Front side. Display: Touch Screen with graphical display. Data Interface: Mini USB interface /USB interface. Facility for direct data transfer to Microsoft Windows Program and Printing. Protection : IP 43 Protection, Chemical resistant finish of the housing. The balance should have protection against unintentional changes of set-up settings. Power: 230V ± 10% . Should have calibration warning function and facility for calibration using external weight. Overload Protection and minimum weight information should be available on display. Application Programs: Weighing. Density termination, Counting, Conversion. Selectable weight units: All standard units. All standard accessories: Standard accessories like AC adaptor, in use cover for keypad protection, Dust Cover, cleaning brushes for proper operation of equipment. Rectangular removable all glass shielding opening from three sides, easy for proper cleaning. Hard copy of instrument manual with specification details. GLP compliance with NABL calibration certificate. IQ/OQ/PQ documentation shall be provided. During installation supplier shall calibrate the instrument using appropriate NABL certified weights. Warranty 3 years. 7 OD247456/2023-2024:Supply and Installation of HOT AIR OVEN Technical Specifications:- • Should be operated on 230V, 50Hz single phase AC supply and having temperature ranging between 50-200°C • Should be made of double walled chamber -Inner made of stainless steel SS 304 grade and powder coated outer surface. • Should provide with three heating elements on three sides of the equipment for uniform temperature on all shelves. • Should be provided with air circulating fan. • Should provide with a variable microprocessor based digital temperature controller with digital display and thermometer should be provided separate. • Should have a minimum chamber size of (L*B*H) 450*450*450 with 2 stainless steel trays with holes. • Should provide with air ventilations. • Warranty period preferably 3 years. 8 OD247457/2023-2024:Supply and Installation ofCOD Digestion Unit Reflux Type: Open Positions: 8 Capacity: 250 mlx 8 tubes Heating Block: Aluminium Temperature Range: Up to 180°C Temperature Accuracy: ±1°C Display: LED • Should have Process Time • Should have Temperature Control • Should have Time Control • Power Consumption should be less than 1400 W • Current Consumption should be less than 8A • Should Supply 8 Air Condensor • Should Supply 8 Test Tubes • Test tube tray Should be Supplied • Cooling tray Should be Supplied 9 OD250345/2023-2024:Supply and Installation ofMicro Controller based Conductivity-TDS Meter with cells and Temp. probe. Specifications:- Conductivity : Range : 0.1µS to200Ms(6 decadic ranges) Resolution : 0.001µS Accuracy : ±1% of F.S. ± 1Digit TDS Range : 0.1ppm to 200ppt.(6 decadic ranges) Accuracy : ±1% of F.S. ± 1Digit Temperature Range : 0 °Cto 100°C (Auto/Manual) Resolution : 0.1°C Accuracy : ±0.2°C±1 Digit Cell Constant : Acceptable from 0.1 to 5.0 Auto Temp. Compensation : 0 °Cto 100°C with PT 100 sensor Display : 7 Digits, 7 Segment LEDs (3 digits for TEMP/TEMPCO 4 digits for Conductivity/TDS) with Automatic decimal point selection TDS –Factor :0.0 to 9.99 user selectable Printer port :Epson compatible 80 Column Dot Matrix Accessories :i)Conductivity cells, cell constant 1.0 (2nos.) ii)Temperature probe (PT-100 Sensor) iii)Stand & Clamp Warranty: 1 year AMC: 2 year OEM should have service center in Kerala Bidder should submitminimum 5 performance certificate of different users in Kerala for the quoted model. 10 OD250346/2023-2024:Supply and Installation of Micro Controller based Turbidity meter Specifications: Ranges:0.05-1000 NTU in 4 Ranges (Automatic) a) 0.05-1 NTU b) 0.1-10 NTU c) 8-100 NTU d) 50-1000 NTU Accuracy : ±1.5% OF FSD in 0-500 NTU ±2% of FSD in 500-1000 NTU Repeatability : ±1% of FS (Std.) Source : LED Detector : Photodiode Display :2 Line 16 Ch.LCD Calibration : 1, 10, 100, 500 &Users selectable values Data Storage :Calibration & Data Stored in Memory Printer port :Epson Compatible 80 Column Dot Matrix Power : 230 Volts ± 10%, 50 Hz Accessories :Flat Bottom Test tubes (25mm Ø) 4 nos. & Light Shield Warranty: 1 year AMC: 2 year OEM should have service center in Kerala Bidder should submitminimum 5 performance certificate of different users in Kerala for the quoted model. 11 OD250343/2023-2024:Supply and Installation of UV-VIS Double Beam spectrophotometer Specifications • Optics : Double Beam • Mode of Operation : Instrument can operate standalone and Pc based • Wavelength:190-1100nm • Wavelength accuracy :± 0 .5nm • Wavelength resolution: 0.1nm • Spectral Bandwidth :1nm • Absorbance range:-4 Abs to 4Abs • Absorbance accuracy:±0.005 at 1Abs • Photometric Repeatability: ±0.002 Abs at 1 Abs • Display: 10 Inch With 1200 X 800 Resolution with touch screen • Sample holder: 5 position automatic sample holder and one for reference. • Stray light:≤0.1% T AT 220nm and 340 nm • Mode of operation: single wavelength, Multi wavelength, Scan, Time scan, DNA & Protein • Measuring mode: %T, Abs, Concentration,Nitrate analysisand Fluoride analysis • Source :Tungsten halogen lamp and Deuterium Lamp • Printer : Should support all type of Printers • Memory : 128GB • Software should have audit trial functionality. • Accessories: 1 pair Quartz cuvette, PC controlling software • Warranty: 1 year • AMC: 2 year • OEM should have service center in Kerala • Bidder should submitminimum 5 performance certificate of different users in Kerala for the quoted model. 12 OD291734/2023-2024:Supply and Installation of M1 CLASS WEIGHT BOX for ETP Lab having the following specification such as • Stainless Steel • 1 mg to 200 gm • Shape : Cylindrical with Knob 13 OD291790/2023-2024:Supply and Installation of REFRIGERATOR for ETP Lab with the following specifications, such as Refrigerator: • Capacity : 300 Liters, Double door with 5 Star rating 14 OD295288/2023-2024:Supply and Installation of FILTRATION ASSEMBLY WITH INBUILT PUMP for ETP Lab having the following specification such as •Flow rate : 4.5 L / Min • Tubing Connection : 8mm •Reusable Funnels with Suitable Adaptor Should be Supplied •Number of Branches : 3