Tender For Electrical Wiring Works For Proposed Xerox Shop And Ladies Parlour At Assam University Silchar. ; 1 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 2 2 x 4 sq. mm 3 2 x 2.5 sq. mm 4 Supply following size PVC/XLPE insulated and PVC sheathed 1.1 KV GSolid Aluminium conductor XLPE Insulated, cores laid up, PVC tape inner sheathed, Armouras specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .10.00 Sq.mm 4 Core armoured U.G. cable 5 Laying of one number PVC insulated and PVC sheathed / XLPEUpto 35 sq. mm 6 Supply fitting fixing of the ISI marked flat PVC cassing n capping on finished wall/surface of size 32 X 12 mm (make AKG,Anchor, Polygrip,presto plast,polycab, MW) complete with necessary drill and fixing with required size screw complete as directed. 7 Wiring for light point/ fan point/ exhaust fan point FRLS PVC insulated copper conductor single core cable in surfacewithearthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 8 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 9 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required 10 Single pole 11 Double pole 12 Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure)of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.25 KA 415V 50 Hz 4P MCCB(Schneider, Legrand, Siemens, Indo Asianmake) 63A TP&N 13 Earthing withG.I.earthpipe4.5metrelong,40mmdia including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 14 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring,washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 15 Wiring to 2 X 5 A pin 6 Amps modular plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Havells or Equivalent Make as approved by the Deptt.) with flat 19 mmISI marked casing n capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including two nos 5 pin 6A Modular type (2M) type plug socket and two nos 6 Amps modular(1M) switch (Legrand/havellls/L&T/Indo asian Glint) or equivalent make as approved by the Deptt.), PVC surface box (6M) switch board with required face plate complete (Legrand/havellls/L&T/Indo asian Glint)with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm.cable to third pin of the plug socket etc. as required complete, when placed elsewhere. 16 Supplying fitting & fixing of recessed 18 W LEDround/square lighting fixtures with die cast aluminium housing with all accessories electronic drivers, holders required for completing the installation and as directed by department.(Jaguar/Havells/Phillips,Crompton) 17 SITC of BLDC star rated 1200 mm Ceiling fan complete as directed by department(Havells, Orient, Usha, Crompton) 18 Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing n capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including providingand fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.),GI/ MS switchboard (I.S.I. marked)with phenolic laminated sheet cover earth continuity with 2.5 sq. mmcableto the 3rd pin of the socketas required complete. Short point up to 3.00 metre. length. 19 SITC of bulk head of 10W made of AL housing and LED light and driver complete as directed by department (Jaguar, Havells, Crompton) 20 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire