}

Tender For Procurement And Installation Of Audio Visual Equipments In The Administrative Building At Bari Brahmana Campus Of Jkedi, brahmana-Jammu And Kashmir

Jammu And Kashmir Small Scale Industries Development Corporation Limited has published Tender For Procurement And Installation Of Audio Visual Equipments In The Administrative Building At Bari Brahmana Campus Of Jkedi. Submission Date for this Tender is 02-01-2025. Audio Video Equipment Tenders in brahmana Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

46906689
Tender For Procurement And Installation Of Audio Visual Equipments In The Administrative Building At Bari Brahmana Campus Of Jkedi
Open Tender
Indian
Jammu And Kashmir
Brahmana
02-01-2025

Tender Details

Procurement And Installation Of Audio Visual Equipments In The Administrative Building At Bari Brahmana Campus Of Jkedi- 1 DISTRIBUTION BOARDS (DBS)Supplying, receiving, storing, handling erecting, testing and commissioning of cabinet type of original factory fabricated double door distribution board 18n guege rust inhibited and backed enamel painted sheet steel and comprising of Incoming ELCB/MCB, outgoing MCBs bus bar (copper), double door, neutral bus bar or links, top & bottom detachable conduit entry plates, earthing terminals with bolts, grouting etc. complete as par specifications (Class of Protection IP-42)Make: Schneider/Siemens/Havells/Legrand(Section-A DBS AND INTERNAL WIRING WORK) 2 Distribution Boards;6 ways TPNDB with 24 Nos. SPMCBs of 10A/20A rating & controlled by 1 No. 63A 4P ELMCB 3 6 ways TPNDB with 12 Nos. SPMCBs of 10A/20A rating & controlled by 3 No. 63A DP ELCB + 1 No. 63A 4P MCB. 4 WIRING FOR CIRCUIT & MISCELLANEOUS WORKSupply, receiving, storing, handling, fixing, wiring for miscellaneous work using 1100 V grade, PVC insulated, Cu conductor stranded wiring cable drawn in rigid U PVC, Conduit (ISI marked), in surface/concealed system complete. with all concuit accessories such as indentification ferrules etc. As per specification conduit being laid either in ceiling slab or wall chase including making & filling chases with cement mortor/ wooden partition above false ceiling with hanging support wherever required as shown in the relevant drawing. Make: Anchor/Havells/Finolex/Polycab/V-Guard(Section-A DBS AND INTERNAL WIRING WORK) 5 4 X 6 Sq.mm. Cu. Wires in 32 mm dia conduit along with 2 X 4 sq mm. PVC insulated copper earth wire. 6 4 X 10 Sq.mm. Cu. Wires in 40 mm dia conduit along with 2 X 6 sq.mm. PVC insulated copper earth wire. 7 Supplying all materials receiving, storing, handling, fixing, wiring & testing for light, fan, exhasut fan, GA socket etc starting from point control box to the outlet using 1100 volts grade 2.5c sq mm. PVC insulated copper conductor stranded wiring cable in concealed/ surface system using 20mm/ 25mm/32 mm rigid U PVC conduit ends, draw, boxes fanhook boxes, fan regulator boxes together with wiring accessories such 6 A module type switch, 3 pin 6A module type socket Batten Holders (wherever required) chrome plated brass screws, including 1.5 sq mm PVC insulated single strand Cu, earth wire, indentification ferrules at either ends complete in all aspects. Conduit being concealed either in ceiling slab/wall chase including making & filling chases with cement mortar etc. wooden partition/above false ceiling with hanging support wherever required as per standard specifications & relevant drawing (Section-A DBS AND INTERNAL WIRING WORK) Make:Anchor/Havells/ABB/Schneider/LegrandNote. i) Each Circuit shall have indipendent earth wire. Each point should be earth 8 one light point controlled by 1No. 6A module type switch 9 A set of two light point controlled by 1 No. 6A module type switch. (2 points counted as 1set) 10 A set of 3 light point controlled by 1 No. 6A module type switch. (3 points counted as 1set) 11 A set of 4 light point controlled by 1 No. 6A module type switch. (4 points counted as 1set) 12 A set of 2 Nos. 3 pin 6A Socket point controlled by 1 No. 6A module type switch 13 A set of 3 Nos. 3 pin 6A Socket point controlled by 1 No. 16A module type switch 14 A set of 1 Nos. 6 pin 16A Socket point controlled by 1 No. 16A module type switch 15 POWER SOCKET POINTSSame as item no. 3.1 but wiring for 6 pin 16A module type socket point using 4.0 sq.mm. PVC insulated Cu. Conductor stranded wiring cable from DB to first socket & same wiring cable from 1st socket to 2nd socket including providing & fixing of 6 pin module type socket with 16A module type switch earthing the third pin with 2.5 sq.mm. PVC insulated single strand copper earth wire, painting etc as required. Make:Anchor/Havells/ABB/Schneider/Legrand(Section-A DBS AND INTERNAL WIRING WORK) 16 Power socket point (Ist point 17 Power socket point (lInd point) 18 Supplying and wiring 33 pin 32A power plug with concealed PVC conduit including P/E 3 pin 32A metal clad socket with 32A DP MCB in sheet enclosure incl. 19 Providing and fixing of Led Panels along with all accessories required for fixing and testing with electric board that may be required to be installed at site wherever found to be necessary as per the direction of Engineer Incharge.75 inch smart led panels for smart classes, HD 4K resolution Make:Panasonic/Samsung/Sony/LG (complete item as approved by Engineer Incharge) 20 STEEL CONDUITSSupply and fixing of the following rigid ERW steel conduits bearing ISI markling with all accessories such as junction boxes, bends, tees as required, the conduits being laid in ceiling slab or floor finish, columns or wall chase/ above false ceiling/ between wooden partition, with hanging support wherever required etc., making and filling of chases with cement mortar and providing G.I. pull wires in conduits.(Make:BEC/AKG/Steel Craft/Ravindra( SECTION-B: CONDUITS FOR TELEPHONES & COMPUTER COMMUNICATION SYSTEM) 21 40 mm conduit 22 32 mm conduit 23 25 mm conduit 24 20 mm conduit 25 PVC CONDUITSSupply & fixing of the following rigid U PVC 2 mm wall thickness conduits bearing ISI marking with all accessories such as junction boxes, bends, tees as requied, the conduits being laid in ceiling slab or floor finish, columns or wall chase/ above false ceiling/ wooden partition with hanging support wherever required etc. making & filling of chases with cement mortar and providing G.I pull wires in conduits.Make: Anchor/Polycab/AKG/Finolex (MMS)(SECTION B: CONDUITS FOR TELEPHONES & COMPUTER COMMUNICATION SYSTEM) 26 40 mm conduit 27 32 mm conduit 28 25 mm conduit 29 20 mm conduit 30 Telephone Tan Blocks/Junction BoxesSupplying and fixing of the following Telephons TAG Blocks made out of MS sheets of 2 mm thickness wherever required as shown in the relevant drawings Properly welded complete with all accessories such as tag block, connectormounting strips tapped holes, fixing bolts, approved shad of point after primer as specification and relevant drawing (SECTION B CONDUITS FOR TELEPHONES & COMPUTER COMMUNICATION SYSTEM)a) 20 Pair Telephone Tag block in suitable M.S. Box. Make: Krone/Phoenix/Wago/Beldon/Panduit/Huawei/Legrand 31 Telephone Sockets/Lan SocketsSupplying and fixing Module type telephone socket, lan socket & tv socket in a suitable glvanized boxMake: Krone/Phoenix/Wago/Beldon/Panduit/Huawei/Legrand(SECTION-B CONDUITS FOR TELEPHONES & COMPUTER COMMUNICATION SYSTEM) 32 RJ-11 socket 33 RJ-45 socket 34 Telephone Sockets/Lan SocketsSupplying, wiring & connecting telephone outlet with four pair 0.6mm dia twin core tinned copper conductor PVC insulated cables in existing conduits.Make: Krone/Phoenix/Wago/Beldon/Panduit/Huawei/Legrand(SECTION-B: CONDUITS FOR TELEPHONES & COMPUTER COMMUNICATION SYSTEM) 35 Supplying, wiring & connecting telephone outlet with two pair 0.6mm dia twin core tinned copper conductor PVC insulated cables in existing conduits. 36 Computer Communication Wiring (LAN Wiring)Supply receiving, storing & laying CAT-5/CAT-6 LAN wiring cable in existing conduits / existing race ways. (SECTION-B CONDUITS FOR TELEPHONES & COMPUTER COMMUNICATION SYSTEM) Make: Anchor/ Havells/ D-link/V-guard 37 A set of 3 Nos. 3 pin 6A Socket point controlled by 1 No. 16A module type switch 38 A set of 1 Nos. 6 pin 16A Socket point controlled by 1 No. 16A module type switch 39 TELEPHONE CABLESSupplying wiring and connecting following pairs 0.6 mm dia twin core finned copper conductor PVC insulated and sheathed Unarmoured telephone cables in existing conduitsMake: Finolex/Delton/Anchor/KEI/Polycab/Bonton. (SECTION B CONDUITS FOR TELEPHONES & COMPUTER COMMUNICATION SYSTEM)20 Pair Cable. 40 SITCof the following luminaries comprising of basic channel, holder, Low loss copper ballast starter, condenser, control gear box complete with decorative attachements, lamps etc as per specification and as pergiving below Decorative attachements, lamps etc. as per specification and as per catalogue number giving below.Make: Wipro/Jaquar/ Philips/Havells/ syska 41 LUMINAIRES & FIXTURES FOR CONFERENCE HALL & BOARD ROOM)a) Receised type fluorescent fixure with lamp2x2 panel 42 1x1 panel (12+12) 43 Decorative 12v/ 50wt halogen complete(12+12) 44 LED strip light 24 w SSK-ST 8060 (90+90) 45 Providing and supplying Installation and testing of 3 TR Hitachi/ LG/ Voltas/ Blue Star,Carrier,Lloyd,Daikin Split type with remote control including voltage stabilizers (Hot & Cold AC two Ton Capacity) Make: Microtek/ V-GUARD/Luminius/ Philips.(For Board Room) Including Copper Pipe from Indoor unit to Out door unit as per Specification. 46 Supplying, testing and commissioning of PVC heavy class pipes duly insulated with all necessary fittings such as elbows, tees, reducers etc. And supports such as clamps with installation.inculding labour, fitting etc (FOR BOARD ROOM)Make: Anchor/Polycab/AKG/Finolex 47 MS Stands Providing and fixing MS Stands for outdoor condensing. (ISI) 48 Copper Refrigerant Piping Providing and fixing copper refrigerant pipping duly insulated to connect indoors units and outdoor units as per required dia.(ISI) and as per Engineer Incharge. 49 Wiring for air conditioners 10mm Coper wire. Make: Havells/ anchor/ polycab/ finolex 50 CHAIRMAN DELEGATE SYSTEM HOST PARTICIPANT SYSTEMHPS (Host Participant System) ControllerCentral Control Unit which shall have Inbuilt recording, inbuilt software for conference management, Total harmonic distortion (THD) <0.02%, Signal to Noise ratio (S/N) >89dBA, Crosstalk >75dB, Dynamic range 94dB, Frequency response 20Hz ~ 20KHz, etc complete as required.Make: Adonis AV / VAL audio / Sennheiser 51 HPS Mic host (Chairman Unit)The microphone unit shall have Frequency Response of 35- 20000Hz while the Speaker shall have frequency response of 20Hz to 20000Hz or better, Total harmonic distortion (THD) <0.02%, Signal to Noise ratio (S/N) >86dBA,Maximum microphone input >100dB SPL, Dynamic range 94dB, Speaker rated output >75dB SPL at 0.5m, (For Conference Hall & Board Room): (1+1)Make: Adonis AV / VAL audio / Sennheiser 52 HPS Mic participant/ Delegate unitThe microphone unit shall have Frequency Response of 35- 20000Hz while the Speaker shall have frequency response of 20Hz to 20000Hz or better, Total harmonic distortion (THD) <0.02%, Signal to Noise ratio (S/N) >86dBA,Maximum microphone input >100dB SPL, Dynamic range 94dB, Speaker rated output >75dB SPL at 0.5m, (For Conference Hall & Board Room): (1+1)Make: Adonis AV / VAL audio / Sennheiser 53 AUDIO/VIDEO CONFERENCE SYSTEMPTZ Camera with 12X Optical Zoom12X PTZ Camera-HDMI 2.0 and USB 3.0 synchronous Video outputs 1/2.7 HDCMOS sensors Zoom-12X Optical Zoom Wide Viewing Angle 65 Degrees Full HD 1080p signal output format with a high frame rate of 60 fps Supports H.264 on Ethernet, RS232 for Control Sensor- HD-CMOS, Iris: f=3.85~43.06mm +_ 5% ; F1.8 ~ F3.56(For Conference Hall & Board Room) : (1+1) Make: Adonis AV / ATDSC / Vaddio 54 CODECThe (1+3) party Appliance shall support H 261H.263 H.263, H.263, H.264. Η 204HP. ITU-T H.238.BFCP, H.264 Baseline Profile,Main: Max. 1080p 30 frames/second, Sub: Max. 1080p 30 frames/second, G.711 μ-law, A-law (3.4 kHz@64 kbps) Remote Camera Control H.224, H.281 (Zoom/Pan/Tilt/Preset), Boundary microphoneMaximumPickupRange,Approx.2m(radius), HDVC web Cloud Licence System should be enable to joinfromdayonetoanyWebconference(Viz.Microsoft Teams, Zoom, Webex, etc.), OS Windows 7, 8.1, 10x4, USB Port USB 2.0 or later, ( Conference Hall & Board Room) (1+1)Make Adonis AV / Panasonic / Lifesize 55 DIGITAL SIGNAL PROCESSOR8 input 8 output Digital Signal Processer with inbuilt Acoustic Echo Cancellation 6.5mm Line Input and Line Output Terminal, 48 KHz sampling rate, 400 Mhz 24 bit floating point DSP processor, Parametric equalizer type: PEQ/Lo-Shelf/HiShelf, High and low pass filters: Bessel/Butterworth/ Link Riley slopes selectable from 6~48dB/ Oct, (For Conference Hall & Board Room) (1+1)Make: Adonis AV / VAL audio / BSS 56 Amplifier Type1HQ Amplifier Power Output 240W / 360W RMS output power, It features both 4-16 ohm operation and 70V/100V LMT output., Overload. Over heat, Multi Input Amplifier Balanced output, 3 Mic, 2 Aux, 1 Media Player, Mic -echo, delay & repeat, 6 Zone, Bass, Treble, Master, Power ON/OFF, (For Conference Hall & Board Room) (1+1) Make: Adonis AV / VAL audio / Martin Audio 57 WALL MOUNT SPEAKERS5.25 LF Driver and 0.5 mylar tweeter / 1 HF Driver, Power Handling: 60W / 40W RMS, 100 V tapping 2W, 4W, 8W & 16W selectable via rotary switch, 110 Db peak max SPL, Frequency Response (-10dB): 70Hz-20khz, (For Conference Hall & Board Room) (6+6) 12 NosMake: Adonis AV / VAL audio / Martin Audio 58 Cronus USB3.0 (40)40 USB 3.0 Active Optical Cable Only. Support data rate of upto 5Gbps. Support resolutions of upto 1080P@60Hz or higher (For coneference Hall & Board Room) (2+2) =4 Nos Make: Adonis AV / Bestnet / D-Link/ Lindy 59 SPEAKER CABLE200 meters 2 Core18 AWG 1.5 sq mm Speaker cable (For Conference Hall & Board Room): (200m+200m) = 400 mMake- Krystals / Belden / Falcon 60 85 LFD DISPLAY WITH WALL MOUNT Large Format Display with wall mount, Aspect Ratio -16:9, Resolution - 3840 x 2160 - 4k UHD, Brightness* - 350 cd/m2, Inbuilt Memory 4 GB RAM & 32 GB memory, Android: v11.0, CPU : Quad Core, Estimated Life Time: 50000 Hrs (Typical), Viewing Angle (HxV) - 178x178, Touch Technology: Infrared, Touch Point: 20, Expansion: Windows OPS: Intel Statandard 80 Pin OPS - Optionals, (For Conference Hall & Board Room) (1+1) Make SAMSUNG / Panasonic / Delta 61 50 LFD DISPLAY WITH WALL MOUNTLarge Format Display, ASPECT RATIO 16:9, RESOLUTION UHD(3840*2160), DISPLAY AREA(H x V): 120.96 (H)*68.04 (V) cm, PIXEL PITCH: 0.0105 (H)*0.0315 (V) cm, DISPLAY COLOURS: 1.07 Billion, VIEWING ANGLE: (HORIZONTAL / VERTICAL) 178 °/178 ° (H/V), AUDIO OUTPUT POWER (RMS): 20 W(10+10 W), CPU: Cortex-A55 x4,1.1 GHz Processor, GPU: Triple core Mali470 600 Mhz, OS & VERSION: INFO Android P - 9.0, MEMORY FLASH: 16 GB EMMC, RAM: 2.0 GB with wall mount (For Conference Hall & Board Room) (2+2) 4 Nos Make SAMSUNG / Panasonic / Delta 62 18U - 19U RACK For Housing all rack mountable equipment (For Conference Hall & Board Room): (1+1)Make- TRS / Valrack / President 63 CABLES AND CONNECTORSCables and connectors and other required items as per site (For Conference Hall & Board Room) Complete Job (ISI) 64 POWER BACKUP6 KVA Online UPS With 1 Hour Backup(For Conference Hall & Board Room): (1+1)Make Microtek/ Luminius/ V-Guard/EATON 65 Supply, Installation, Testing & CommissioningInstallation, Integration, rack Management, Cabling. Testing and Commissioning (ISI)(For Conference Hall & Board Room) Complete Job: (1+1)

Key Value

Document Fees
INR 5000 /-
EMD
INR 204760.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail