Tender For Laboratory Maintenance work in Microfluidics lab IWUNB at CSIR AMRPI, Bhopal- 1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand(zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources). 2 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. 3 Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. 4 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. . Size of Tile 600 x 600 mm 5 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling/grouting and finishing complete as per direction of Engineer-in-charge. 6 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes 110 mm diameter 7 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. ----12.42.1 Coupler-----12.42.1.2 110 mm 8 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion. ----12.42.5 Bend 87.5° 12.42.5.2 110 mm bend 9 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. ----12.42.6 Shoe (Plain)12.42.6.2 110 mm Shoe 10 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermalexpansion.Single tee with door 110x110x110 mm 11 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 12 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13 Wall painting with premium acrylic emulsion paint of interior grade(Plastic Paint), having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.and colour.Two orcoats. 14 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. 15 Removing dry or oil bound distemper, oil paintwater proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.Line drawings is included and for any query related to this item site visit may be done and E-in-c may be contacted if required. 16 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 17 Cutting holes up to 30x30cm in walls including making good the same 18.76.1 with common burnt clay F.P.S. (non modular) bricks 18 Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. 19 Labour for shifting, removing wastage and other miscellaneous work. 20 Cleaning of roof including shifting of unuseful and unwanted material like bottles, aluminium partition boxes and other materials by manual labour to scrap yard 21 Providing and fixing false ceiling in required and shape to suspended to ceiling at a suitable height of 30 cm in GI runners and channel frame work profle section in Gyproc board in desired shape and size including coping, flat surface and desired cutting in architectural shape as per direction of E-in-charge 22 P/f Aluminium Partion in fixed portion including door/ window section in aluminium sectionpowder coated medium gauge with 4mm glass and particle board as per requirement and required sealing rubber including fitting with clip, rubber as required with screws, handles, Latch, hinges lock etc all fittings and fixtures as requiredand desired by E-in-C. 23 Shifting of AC including Refilling/ topupof gas if required and putting them in brackets/ stand of outdoor unit. 24 Injecting chemical for control of termite by anti-termite treatment by suitable chemicals as permanufacturer specifications including the cost of chemical emulsion along wall and floor usingchemical emulsion of the vertical/ horizontal surfaceas per the site requirement and instruction of E-in-C In wall,floor, foundation, side , roof sides and plinth beam corner. 25 Fixing of pipe of suitable size round/square 50 mm in existing Railing by suitable means and connecting it to existing railing by suitable fitting fixturesincluding painting of railing by synthetic enamel paint as per instruction and direction of E-in-C 26 Providing and applying multicoat synthetic plaster as per approved design, pattern texture in 3 mm thick on new plastered surface finished in proper line and level as directed by Engineer-in-charge in five coats consisting of composition of four order of application given as under includig all materials, labour Tools and Plant etc.1) Scrapping of the new surface and applying sealer primer mixed with water in the ratio 1:3 (part sealer primer : 3 part water) and applying by brush @ 0.25 kg/sqm.2) Applying levelling coat of spectrum rustic fine or equivalent with trwel as a putty finished to generate required texture by trowel.3) Applying third coat of synthetic plaster with trwel @ 2.5 kg/sqm finished to generate required texture by trwel.4) Applying two coats of exterior super fine pigmented acrylic wall coating as top coat @ 0.5 kg/sqm in two coats and colours as approved by Engineer-in-charge all up to a height of 10mRustic in wall 27 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer for door weight upto 36 kg to 80 kg and door width from 701 mm to 1100 mm, with speed adjustment with necessary accessories and screws etc. complete. 28 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box/celling rose and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C. 29 Wiring for circuit / submain wiring alongwith earth wire with the following size of FRLSPVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required 30 a) 2 X 1.5 Sq.mm + 1 X 1.5 Sq.mm earth wire. 31 b) 2 X 2.5 Sq.mm + 1 X 2.5 Sq.mm earth wire. 32 c) 2 X 4 Sq.mm + 1 X 4 Sq.mm earth wire. 33 d) 2 X 6 Sq.mm + 1 X 6 Sq.mm earth wire.. 34 e) 4X10 sq mm + 2X6 sq mm earth Wire 35 f) 4X16 sq mm + 2X6 sq mm earth Wire 36 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (Make - BEC/Kissan/Kasta/ Supreme/ Sudhakar/ Reliance) 37 a) 20mm 38 b) 25mm 39 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 40 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 41 Supplyiong and Fixing following size/ Modular plate, GI box alongwith modular base & cover plate for modular switchesin recess ets as required 42 6 module 43 8 module 44 Supplying and fixingfollwing modular Switch/Socket on the exixting modular plate & switch box including connections excluding moddular plate etc as required. 45 3 pin5/6 Amps Socket outlet 46 15/16 A switch 47 6 pin 15/16 A socket outlet 48 Supplying and fixing following way surface/recess,Verticle type ,415 volt TPN MCCB Distributionboard ofsheet steel,dust protected ,duly powder painted ,inclusive of 200 Amp tin Bus bar ,common Neutral link ,earth bar, din bar for mountingMCBs( but without MCB or Incomer ) as required 49 12 way (4 +36), Double door 50 Supplying installation testing & commissioning of 100 watt integral LED floodlight fitting with driver inside a PDC Housing, highly efficient, reliable with Driver & all accessories i/c connection complete etc. as required. 51 Supplying Installation testing and commissioning of min200 mm , 1350rpm PVC exhaust fan including louver/ shuter as front cover in the existing opening, including making good the damage, connection with 3 x 1.5 Sq. mm copper conductor i/c testing, commissioning etc. as required. (Make:Crompton/Orient/Havells/usha) 52 Supplying Installation testing and commissioning of 300mm , Wallfan , including making good the damage, connection with 3 x 1.5 Sq. mm copper conductor i/c testing, commissioning etc. as required.(Make:Crompton/Orient/Bajaj ) 53 Supplying,installation,testing and commissioning of prewired LED compact light fitting of following type complete with all accessories etc. recess/surface/panel/flase ceilingi/c connection with3 x 1.5 sq. mm FRLS PVC insulated copper conductor wire earthing etc. as reqd. 54 a)supplying and fixing of LED Recess/surface mounted downlight 15/18 watt with Lamp complete with connection and testing etc as required as per Havellsmodal no.LHEAABPIL1WO012or similar make like havells/ Crompton/philips/wipro) 55 b) LED BETTEN fittings surface/recess mounted in 4 feet length, 20/22 W 4000 lumens , cuminous efficiency105 Lum//Watt, cool day lightCRI 80, CRCA body , IP20 life L 70, 40 K, PF>0.95, THD<10%with PC glossy diffueser suitable for short circuit & overvoltage cut offi/c connectionwith 1.5 sq. mm FRLS PVC insulated, copper conductor , single core cable & earthingcomplete etc. as reqd. 56 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel/distribuibution board including drilling holes in cubicle panel, making connections, etc. as required. 57 200 Amps ,25 KA