}

Tender For Administrative Block Replacement Of Supply Rain Water Administrative Block Replacement Of Supply Rain Water And Sanitary Pipe Lines In The Utility Ducts And Repainting Works At Room No 102 Of Klc Administrative Block Ground Floor Room No 102 Pa, Thiruvananthapuram-Kerala

Public Works Department has published Tender For Administrative Block Replacement Of Supply Rain Water Administrative Block Replacement Of Supply Rain Water And Sanitary Pipe Lines In The Utility Ducts And Repainting Works At Room No 102 Of Klc Administrative Block Ground Floor Room No 102 Pa. Submission Date for this Tender is 30-12-2024. Pipe Laying Tenders in Thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

46862805
Tender For Administrative Block Replacement Of Supply Rain Water Administrative Block Replacement Of Supply Rain Water And Sanitary Pipe Lines In The Utility Ducts And Repainting Works At Room No 102 Of Klc Administrative Block Ground Floor Room No 102 Pa
Open Tender
NCB
Kerala
Thiruvananthapuram
30-12-2024

Tender Details

Tender For Administrative Block Replacement Of Supply Rain Water Administrative Block Replacement Of Supply Rain Water And Sanitary Pipe Lines In The Utility Ducts And Repainting Works At Room No 102 Of Klc Administrative Block Ground Floor Room No 102 Painting Works General Civil Work - GENERAL-Administrative Block - Replacement of Supply, Rain Water & Sanitary Pipe lines in the utlity ducts and repainting works at Room No 102 of KLC-Administrative BlockGround Floor Room No 102- Painting Works-General Civil Work Sl. No. Item Description 1 REPLACEMENT OF DUCT LINES 2 OD131426/2024-2025:Providing and fixing scaffolding system (cup lock type) on the inside utility ducts, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer in- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. 3 5.6:Reinforced cement concrete work in chimneys, shafts, up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand(Zone III) : 3 graded stone aggregate 20 mm nominal size) 4 6.3.1:Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With F.P.S. ( non modular ) bricks 5 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 6 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 7 5.9.11:Centering and shuttering including strutting, etc. and removal of form for:Chimneys and shafts 8 OD131425/2024-2025:Resettting and fixing scaffolding system (cup lock type) on the inside utility ducts, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer in- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. 9 15.42.1:Dismantling C.I or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead:75 to 80 mm dia pipe 10 15.42.2:Dismantling C.I or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead:100 mm dia pipe 11 15.42.3:Dismantling C.I or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead:150 mm dia pipe 12 OD127339/2024-2025:Engaging Plumber for dismantling PVC/GI Pipes from the Ducts as per the requirement and as per the directions from the departmental officers 13 OD127530/2024-2025:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineering-in-charge 160 mm dia 6 kgf/cm2 External work - Exposed on wall 14 50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 15 50.18.9.18.1:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 16 50.18.9.17.2:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall 17 50.18.9.20.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 18 50.18.9.20.5:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 19 50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee 20 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 21 50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 22 50.18.9.21:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow 23 50.18.9.21.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee 24 50.18.9.21.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 25 50.18.9.21.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 26 Painting Works - Room No 102 27 OD96069/2024-2025:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 28 22.23A:Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. 29 13.26:Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 30 13.51.2:Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces:Two coats 31 OD96071/2024-2025:Applying acid wash on floor or wall tiles including material, labour charges etc. complete 32 OD96141/2024-2025:Engaging coolie for cleaning the floors and Window grils etc as per the direction of teh departmental officers 33 OD132974/2024-2025:Machine polishing two coats to old marble floor using carborundum stone including labour charges etc complete .As per the direction of engineering in charge.

Key Value

Document Fees
INR 2760 /-
EMD
INR 31651.0 /-
Tender Value
INR 12.66 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail