}

Tender For Repair/ Replacement Of Old Unsv Internal Wiring, Summer Appliances, Geyser, Mcb, Mccbs And Other Misc E/M Work At Pratap Chowk, Taurus Enclave, Officer Md Accn, Arjan Vihar, New Pratap Chowk, Double Story Officer Md Accn And Adjoining Unit Ar, delhi-Delhi

Military Engineer Services has published Tender For Repair/ Replacement Of Old Unsv Internal Wiring, Summer Appliances, Geyser, Mcb, Mccbs And Other Misc E/M Work At Pratap Chowk, Taurus Enclave, Officer Md Accn, Arjan Vihar, New Pratap Chowk, Double Story Officer Md Accn And Adjoining Unit Ar. Submission Date for this Tender is 18-01-2025. Air Conditioner Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

46849354
Corrigendum : Tender For Repair/ Replacement Of Old Unsv Internal Wiring, Summer Appliances, Geyser, Mcb, Mccbs And Other Misc E/M Work At Pratap Chowk, Taurus Enclave, Officer Md Accn, Arjan Vihar, New Pratap Chowk, Double Story Officer Md Accn And Adjoining Unit Ar
Open Tender
Indian
Delhi
Delhi
18-01-2025

Tender Details

Repair/ Replacement Of Old Unsv Internal Wiring, Summer Appliances, Geyser, Mcb, Mccbs And Other Misc E/M Work At Pratap Chowk, Taurus Enclave, Officer Md Accn, Arjan Vihar, New Pratap Chowk, Double Story Officer Md Accn And Adjoining Unit Area Under-- 1 Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge. 2 M & L for Point wiring complete with 1.5 sqmm single core PVC unsheathed insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through existing metalic/non-metalic rigid PVC conduit medium grade ISI Marked not less than 20 mm dia including all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc by cutting chases and including provision of 1.5 sqmm PVC unsheathedinsulated copper cable FRLS as earth continuty, suitable fabricated branded modular metal flush box / M S steel terminal boxes duly make embossed, concealed in wall and making the adjacent surfaces smooth through POP work & painting as per site requirement incl provision of modular inner and outer cover plates with laminated top sheet cover for housing switches , socket out let and fan regulators etc concealed in walls with suitable , all as specified and as directed for the followings:- 3 One light/Exh fan point controlled by oneway switch 4 One bell /buzzer point controlled by one bell push 5 One light point controlled by two Nos two way switches 6 One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board. 7 One 3 pin 5 Amps socket outlet point controlled by oneway switch on same board 8 All as per item No 2 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete. 9 Supply & fixing in replacement of white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge. 10 Supply & fixing in replacement of white cover plate with frame 3/4 module complete all as specified and directed by Engineer in charge. 11 Supply & fixing in replacement of white cover plate with frame 6 module complete all as specified and directed by Engineer in charge. 12 Supply & fixing in replacement of white cover plate with frame 8 module complete all as specified and directed by Engineer in charge. 13 M&Lswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified. 14 M&LModular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified. 15 M&Lswitch modular type 6amp SP two way, 1 module complete all as specified. 16 M&L Modular Bell pushbutton SP with indicator 6 Amps, 1 module 230V AC complete. 17 M&L switch Modular type 16 Amps 1Way, 1 module with modular plat, 230V AC complete. 18 M&LModular socket outlet 2/3 pin 6/16Amp universal socket 2 module complete. 19 M&L modular stepped type electronic fanregulator 120W, 2 module complete . 20 M&L Switch piano flush button type single pole one way 6 Amps complete all as specified. 21 M&L switch piano flushbutton type single pole 16 Amps complete all as specified. 22 M&L socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified. 23 M&L socket outlet6 Amp flush button type complete all as specified. 24 M&L regulator electronic5 steps type suitable for 1200/1400 mm sweep 230 volts. 25 M&L bell electric (dingdong) 230 volt, SPall complete all as specified and directed . 26 M/L insulated body, angle holder (metal ring) with back plate complete. 27 S&F ceiling rose surface PVC type with three terminals complete all as specified and directed . 28 M&L sheet metalenclosure, single pole and neutralwith a two pin and earth plug and socket 240 Volts grade10Amps complete with onesingle poleMCB C series 20 A capacity complete all as specified. 29 Taking out existing and repair /replacement of Modular mini MCB 20 to 32 Amps 240 volts 10 KA 50 HZ C curve complete. 30 S & F LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2000 systems lumen outputwith lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. 31 S & F LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. 32 S & F LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 25,000 burning hours at L70 criteria,Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. 33 S&F in replacement of decorative type wall mounted luminaire (Comet)with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge . 34 S & F surface ceiling mounted, LEDdown light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 25000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driverwithvoltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. 35 S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified. 36 S & F LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified. 37 S&F Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 4 sqmmcable shall be measured as one RM. 38 S&F Sub main wiring with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 6 sqmmcable shall be measured as one RM. 39 S&FSub main wiring with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 10 sqmmcable shall be measured as one RM. 40 S & F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete. 41 S&FMCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete. 42 S&F MCB DB SPN 02 way, single door 240 V AC 50Hz , with 10 Amps MCBSPN as incomer / out goingcomplete. 43 S &F MCB DP 6-32 Amps 240 volts 10 KA 50 HZ C curve complete. 44 S & F MCB DP 40 to 63 Amps 240 volts 10 KA 50 HZ C curve complete. 45 S & F MCB SP 6-32 Amps 240 volts 10 KA 50 HZ C curve complete. 46 S & F MCCB 250 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting . 47 S & F and Replacement of Ventilating Fanupto 250 mm sweep, not less than 1200 RPM, non metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. 48 S&F and replacement of wall mounted fan 400 mm sweep, aerodynamic designed, air delivery ≥ 70 CMM, thermal over load protected motor, 3 blade white colour, 230 volts, 50 Hz, 1420 RPM with 90 degree oscillation and having speed & oscillation control by two pull cords system complete all as specified . 49 Taking down ceiling fan / exhaust fan/ fresh air/ Wall mounted fanincluding refixing the same after necessary repairs/ replacement of unserviceable/ wornout part and testing as per entire satisfaction of Engr-in- Charge complete all as specified and directed.Note : Spare parts shall be measured and paid seperately under relevent of supply only. 50 M&L for opening up the winding of ceiling fan 1200 mm 1400 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete.Taking down and testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge. 51 M&L for opening up the winding of Exhaust fan 225/300/450 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Taking down and testing of the exhaust fan after refixing in position to the entire satisfaction of Engr-in-Charge. 52 S&F in replacement Ceiling fan blade suitable for 1200mm /1400 mm sweep of any make with suitable size as per site requirement complete all as specified and directed by Edngineer-in-Charge. (As per sample). 53 S&F in replacement exhaust fan Metal blade suitable for 225/300mm sweep of any make with suitable size of split pin as per site requirement complete all as specified and directed by Edngineer-in-Charge.(As per sample). 54 S&F PVC canopy upper and lower of celing fan of any make & size complete with nuts, bolts & washers as per sample approved (As per sample) complete all as specified and directed by Edngineer-in-Charge. 55 Taking down old unserviceable down rod and supply and fix 1.5 mtr long down rod duly made out off Mild steel including taking down & refixing of existing ceiling fan of any sweep and make and making connection from ceiling rose to PVC connector complete all as specified and directed by Engineer-in-Charge. 56 S&F in replacement ceiling fan down rod 0.6 mtr long duly made out off mild steel including rubber bush nut, bolt, washer and split pin complete all as specified and directed by Engineer-in-Charge. 57 S&F in replacement capacitor of2.5 MFD complete all as specified and directed by Engineer-in-Charge. 58 S&F in replacement capacitor 3.15 MFD complete all as specified and directed by Engineer-in-Charge. 59 S&F in replacement onlyball bearing No. 6202 complete all as specified and directed by Engineer-in-Charge. 60 S&F in replacement onlyball bearing No. 6203 complete all as specified and directed by Engineer-in-Charge. 61 M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dustetc.and endorsement of fan no.with black synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. 62 M & L for painting of exhaust fans complete, in situ with synthetic enemel paint by spraying including filling cavities with filler, one coat after cleaning all dustetccomplete all as specified and directed by Engineer-in-Charge. 63 S&F inreplacement PVC cable copperconductormulti strandrad flexible 23/.0076 twin core and making connections from ceiling rose to fan complete all as specified and directed by Engineer-in-Charge. 64 S&F in replacement Fresh air fan motor of suitable capacity as required on site 230 volts, 50 Hz, AC supply suitable for 300/250/200 mm size Fresh air fan as per sample complete all as specified and directed by Engineer-in-Charge. 65 S&F in replacement only exhaust fan motor of suitable capacity as required on site, 230 volts,50Hz,suitable for 225/300 mm size exhaust fan complete all as specified and directed by Engineer-in-Charge. 66 S&F in replacement non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as specified and directed by Engineer-in-Charge. 67 S&F in replacement for fixing in replacement safety pressurevalve (as per sample)for geysers complete all as directed by Engineer-in-charge. 68 S&F in replacement SS braided pipe of 12 mm (internal) suitable for hot/cold water, 600 mm long with brass nuts and rubber washers complete all as specified and directed by Engineer-in-Charge. 69 S&F in replacement heating element of 2 KW,(as per sample) with nut bolt washercomplete all as specified and directed by Engineer-in-Charge. 70 S&F in replacement of thermostat for 25/35/50 ltrs capacityof geysers complete all as specified and directed by Engineer-in-Charge. 71 S&F in replacementneonlamp/indicator lamp for geysers complete all as specified and directed by Engineer-in-Charge. 72 S&F in replacement plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer-in-Charge. 73 S&F socket 3 pin 20 amp earth metal clad(ISImarked) complete all as specified and directed by Engineer-in-Charge. 74 S&F in replacementfastner 100mm long & 6mm dia long with suitable size of nut for fixing geyser/Exhaust Fan complete all as specified and directed by Engineer-in-Charge. 75 Repair and replacement of Elecronic mother board / PCB, Existing sensor, Exhaust motor etc of Existing electric chimney and repair/replacement of unsv any parts (FLEXIBLE HOSE PIPE) etc of electric chimney of any make as per site requirment complete all as specified and directed by Engineer-in-Charge. 76 M&L for cleaning service of electric chimney and repair/replacement of unsv any parts of electric chimney of any make as per site requirment complete all as specified and directed by Engineer-in-Charge. 77 S&F LED 2 X 2 ft backlite surface mounted fitting 36/40 Wattsnot less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours ,Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed. 78 Schedule of Credit

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 11-01-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-01-2025

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail