Tender For Repairs Maintenance Of Split Acs Window Acs Package Acs And Deep Freezer Under Ge Golconda, golconda-Telangana

Military Engineer Services has published Tender For Repairs Maintenance Of Split Acs Window Acs Package Acs And Deep Freezer Under Ge Golconda. Submission Date for this Tender is 16-01-2025. AMC of Air Condition Tenders in golconda Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

46848120
Corrigendum : Tender For Repairs Maintenance Of Split Acs Window Acs Package Acs And Deep Freezer Under Ge Golconda
Open Tender
Indian
Telangana
Golconda
16-01-2025

Tender Details

Tender For Repairs Maintenance Of Split Acs Window Acs Package Acs And Deep Freezer Under Ge Golconda-- 1 Cold storage Room: Supply and fixingsemi sealed compressor of package plant of ( 1.5X4 TR) capacity from its installed position by placing dummy plates to suction and discharge valves, opening of the compressor, removing of all the internal parts, cleaning of all parts thoroughly, overhauling of the compressor, replacing of worn out parts such as suction reeds, discharge reeds, piston rings, compression rings, connecting rods, bearings, piston pins, springs, spring washers, nuts, bolts, washers `O’ rings, gasket set etc , reassembling of the all internal parts after replacing the worn out parts, rewinding of the compressor re-fixing back, removing of the dummy plate, oil changing and checking the oil pressure, vaccumising and leak testing and testing the compressor completely all as specified and directed by Engineer-in-Charge.NOTE: The rate quoted shall deemed to include for compressor oil. However refrigerant gas will bemeasured and paid separately as per actual requirement. 2 Supply and fix Copper pipe With insulation of any Size 5/8suitable for cold storageincluding taking out old pipe all as specified and directed by Engineer-in-Charge. 3 Supply and fix 3 Core Copper Cable of any Size suitable for cold storageall as specified and directed by Engineer-in-Charge. 4 Cleaning of the evaporator coils of requiredcapacity for (1.5X4) TR including cleaning with acid by forced feed method to remove the unwanted dust particles formed on the coil and fins, cleaning of the dust particles, parts of periodical maintenance, cleaning of liquid lines, strainer, expansion valve etc. and testing complete all as specified and directed by Engineer-in-Charge. 5 Testing of Nitorgen Pressureof GasSupply & charge refrigerant gas R-22 upto required level complete all as specifiedand directed. 6 Supply and fix cold storage room Temperature gauge as per sample complete and all as specified and directed by Engineer-in-Charge. 7 Supply and fix out door unitfan motor with blade water proof type suitable for cold storage unit all as specified and directed by Engineer-in-Charg 8 Servicing ofthe Cold Storage Unit of (1.5x4) ton capacity, cleaning of the evaporator coils externally,Water Washing with Jet Pump to remove the dust particles deposited on the cooling coil, cleaning of the condensing units to reduce the discharge pressure with the Caustic Soda / Chemical and testing complete all as directed. 9 S & Fixcapacitor of 50/60 MFD with ContactorsforCold Storage Plant all as directedand taking out the old unserviceable one. Make- CONCAP /BHEL/TIBCON 10 S & FixAir Filter to the Cold Storage Plant of ( 1.5x 4) Ton capacityand taking out the old unserviceable one. 11 S & Fix Thermostatset complete for Cold Storage Plant of( 1.5x 4) any make/model/capacity including removing the old unserviceable thermostatMake – Danfoss / Renutraul/Annapurna 12 SPLIT ACs /Window ACs .Taking down carefully old burnt/unserviceable compressor unit of 1.0 ton capacity window type / Split typeAC and replacing the same with New compressor including necessary accessories and mounting materials, welding, brazing, leak testing, vaccumising and charging the refrigerant gas to the required pressure and weight, reinstalling the AC unit at the same place including testing and commissioning complete to any make of AC all as directed. Make :Kirloskar / Voltas/ LG/ OEMNote:- Rate quoted shall be inclusive of R-22 refrigerant gas charging, testing and commissioning. 13 All as per item No : 12 above but for Window/Split type AC 1.50 Ton Capacity 14 All as per item No : 12 above but for Window/Split type AC 2.00 Ton Capacity 15 S & Fix Relay assembly and connecting with necessary wiring complete suitable for Window/Split type of AC 1.0/1.5/2.0 Ton Capacityand taking out the old unserviceable one. Make : Shriram /Renutraul / Voltas 16 S & FixOver load protector complete suitable for Window/ Split type AC of1.0/105/2.0Ton Capacity including removal of old Un Serviceable. Make : Shriram /Renutraul / Voltas 17 S & FixThermostat set complete for window/split type AC of any make/model ofCapacity 1.0/1.5/2.0 Ton including removing the old unserviceable Make –Renutraul/Annapurna/Usha / OEM 18 S & Fix Blower fan motor, withfixing arrangement complete operating on 215 / 240 Volts, single phase AC supply, multi speed suitable forWindow AC 1/1.5/2.0 Ton capacity including taking out the old one. Make : OEM 19 Rewinding of outdoor fan motor with same guage and turns and weight of copper enameled wire and replacement of bearing, testing and commissioning of 1.0/1.5/2.0 Ton split type AC of any make/ model complete all as directed. 20 S & Fix capacitor of 36/45 MFDforWindow/Split type ACs all as directedand taking out the old unserviceable one. Make- CONCAP /BHEL/TIBCON 21 S & Fixcapacitor of 50/60 MFDforWindow/Split type ACs all as directedand taking out the old unserviceable one. Make- CONCAP /BHEL/TIBCON 22 S & Fix Selector switch normal/Rotary complete for window type A/C 1 to 2 Ton capacity suitable for push button type including taking down the unserviceable one 23 S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for window /Split type AC 1 Ton to 2 Ton capacity and taking out the old unserviceable one. 24 S & FixWiring kit for window type AC of 1.0/1.5/2.0 Ton capacity with copper wire PVC insulated single core of size1.5 sq mm, clips, terminal connector etc complete all as directedand taking out the old unserviceable one. 25 Allas per item No : 25 above but forSplit type AC of capacity 1.0/1.5/2.0 ton . 26 Cleaning the unit with CTC except evaporator and condensor and leak testing the system with Nitrogen gas and detecting the leak and repairing, brazing and sealing the leakage including charging the refrigerant R-22gas to the required pressure and weight of gas for 1.0/1.5/2.0 Ton capacity window type ACof any make complete all as directedNote :- Gas charging will be measured separately against relevant item of this schedule. 27 Allas per item No : 26 above butSplit type AC of capacity 1.0/1.5/2.0 ton . 28 Servicing to the split type AC units of 1/1.5/2.0 ton capacity, cleaning of the evaporator coils externally with Caustic Soda / Chemical to remove the dust particles deposited on the cooling coil, cleaning of the condensing units to reduce the discharge pressure with the Caustic Soda / Chemical and testing complete all as directed. 29 Servicing of the window type Air Conditioners of capacity 1/1.5/2.0 ton capacity, cleaning of the evaporator coil externally with Cautic Soda / chemical to remove the dust particles, cleaning of the filters and testing complete all as directed. 30 S & FixAir Filter to the window /Split type Air Conditioners of 1/1.5 /2.0 Ton capacityand taking out the old unserviceable one. 31 S & FixEvaporator coil, including connected brazing welding work and provn of refrigerant suction/discharge line suitable forWindow Ac / Split TypeAc1.0/1.5 / 2.0TR capacity including removing the unserviceable evaporator coil from the existing position all as directed. 32 S & Fix new remote control assembly for split type AC 1.5 /2.0 TR capacity including removing of the old unserviceable complete all as directed. 33 Taking out the unserviceable condensor coil and S & F new condensor coil made out of 25 SWG copper tubing having 30/34G aluminium fins per CM length for window AC/Split type AC s of 1.5 Ton capacity all as directed including taking down old U/S condenser coil. 34 S & FixFront grill for Window AC as existing make/model and taking out the old unserviceable one. 35 S & Fixindoor blower motor for split type AC of capacity 1.5/2.0 Ton as per existing model complete all as directed and taking out the old unserviceable one. Make : OEM 36 S & FixPVC drain pipe 25 mm for rectifying water leakage from AC units complete all as directedand taking out the old unserviceable one. 37 S & Fixcopper tube of size 3/8, 5/8 inch dia includng necessary soldering , flooring and connecting and testing in between indoor to out door units of split type AC 1.5/2.0 Ton complete all as directedand taking out the old unserviceable one. 38 Description all as per Item No-37 above but size of copper tubing 1/2, 1/4 inch dia complete all as directed. 39 S & Fixinsulation felt for split type AC 1.5 / 2.0 Ton copper tube inlet/outlet to out door unit up to 3 mtr in length complete all as directed. 40 Taking out unserviceable 1 Pole contactor fromsplit AC and replacing the same with new contactor suitable for 240V,50Hz coil complete all as directedand taking out the old unserviceable one. 41 S & Fix Oscillation motor for the indoor unit of the split type AC of 1.5/2.0 Ton capacity complete all as directedand taking out the old unserviceable one. 42 Taking out unserviceable dummy nuts from the split AC unitsand S & Fix new Brass Dummy / Flare nuts of existing size complete all as directedand taking out the old unserviceable one. 43 S & FixFan blade for 1.5/2Ton capacity window/Split type ACsas per existing size/ modelcomplete all as directedand taking out the old unserviceable one. 44 Taking down UNSV Indoor unit of Split type AC of 1.5 TR capacity any make, model and S & F new indoor uint of same capacity suitable to existing Outdoor Unit including the necessary connections and testing complete all as directed.Make : OEM 45 Repairs to PCB ofsplit type AC 1.5 /2.0 TR capacity including of replacement of electronic spares complete all as directed. 46 DEEP FREEZERsTaking out burnt / unserviceable compressor from existing Deep Freezerand S & F new sealed compressor unit including necessary welding/brazing/pressure testing with refrigerant after charging leak proof condition and testing complete for Deep freezers of any capacity. Note:- Rate quoted shall be inclusive of R-134a refrigerant gas charging, testing and commissioning.Make : Kirloskar/ Shriram/Voltas/Hitachi 47 S & Fix Over load protector complete suitable for Deep Freezerof any make/model of capacity 280/310Ltrs including removal of old Un ServiceableMake : Shriram /Renutraul / Voltas 48 S & Fix Thermostate set complete for Deep Freezerof any make/model of capacity 280/310Ltrs includingremoving the old unserviceable Make – Danfoss / Renutraul/Annapurna 49 S & FixCopper capillary tube including strainer with necessary brazing, Leak Testing suitable for Deep Freezerand taking out the old unserviceable one. 50 Cleaning the gas system with CTC, rectification of Bodyleakages, M&L Charging gas with refrigerant gas incl cutting/welding/brazing and leak testing with nitrogen, testing including commissioning complete for deep freezer 280/310 ltrs capacity Note :- Gas charging will be measured separately against relevant item of this schedule. 51 Testing of Nitorgen Pressure, Supply & charge refrigerant gas R-22 upto required level complete all as specifiedand directed. 52 Testing of Nitorgen Pressure, Supply & charge refrigerant gas R-134 upto required level complete all as specifiedand directed. 53 S & FixFan Motor With blade for Deepfreezer of any sizeas per existing size/ modelcomplete all as directedand taking out the old unserviceable one. 54 S & Fix Plug Top of 15A/20A as per existing size/ modelcomplete all as directedand taking out the old unserviceable one.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 09-01-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-01-2025

Key Value

Document Fees
INR 500 /-
EMD
INR 19000.0 /-
Tender Value
INR 9.50 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.