Tender For Procurement Of Ae Make Transducers, NELLORe-Andhra Pradesh

Boards / Undertakings / PSU has published Tender For Procurement Of Ae Make Transducers. Submission Date for this Tender is 25-01-2025. Audio Transducers Tenders in NELLORe Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

46828597
Corrigendum : Tender For Procurement Of Ae Make Transducers
Open Tender
Indian
Andhra Pradesh
Nellore
25-01-2025

Tender Documents

Tender Details

Procurement Of Ae Make Transducers , Ac Current Transducer: (Pd1-53135) Input: 0-5.333A Ac, Ange:0-24Kaac Ctr: 22500/5A, Output 1: 4-20Madc At 500 Ohm Output 2: 4-20Madc At 500 Ohm Accuracy: +/-0.2 Percent Aux.Supply: 240V Ac,Ac Voltage Transducer (Pd1-51135) Input: 0-122.22 Vac, Range: 0-30 Kvac Ptr: 27Kv/ 3/110/ 3 Output 1: 4-20Madc At 500 Ohm Output 2: 4-20Madc At 500 Ohm Accuracy: +/-0.2 Percent Aux.Supply: 240V Ac,Frequency Transducer (Pd1-54135) Input: 110Vac, Range: 45-50-55 Hz Output 1: 4-12-20Madc At 500 Ohm Output 2: 4-12-20Madc At 500 Ohm Accuracy: +/-0.2 Percent Aux.Supply: 240V Ac,Watt Transducer (3P-2E-3W) (Pd3-57336) Input: 0-905.34W, Range: 0-1000 Mw Ptr: 27Kv/ 3/110/ 3 , Ctr: 22500/5A Output 1: 4-20Madc At 500 Ohm Output 2: 4-20Madc At 500 Ohm Accuracy: +/-0.2 Percent Aux.Supply: 240V Ac,Var Transducer (3P-2E-3W) (Pd3-56336) Input: (-)905.34 - 0 - (+)905.34 Var, Range: (-)1000 - 0 - (+)1000 Mvar, Ptr: 27Kv/ 3/110/ 3 , Ctr: 22500/5A Output 1: 4-12-20Madc At 500 Ohm Output 2: 4-12-20Madc At 500 Ohm Accuracy: +/-0.2 Percent Aux.Supply: 240V Ac,Power Factor Transducer (3P-2E-3W) (Pd3-55336) Input: 5A, 110V, Range: 0.5Lag-1.0-0.5Lead Output 1: 4-12-20Madc At 500 Ohm Output 2: 4-12-20Madc At 500 Ohm Accuracy: +/-0.2 Percent Aux.Supply: 240V Ac,Va Transducer (3P-2E-3W) (Pd3-58336) Input:905.34 Va, Range:0 - 1000 Mva, Ptr: 27Kv/ 3/110/ 3 , Ctr: 22500/5A Output 1: 4-20Madc At 500 Ohm Output 2: 4-20Madc At 500 Ohm Accuracy: +/-0.2 Percent Aux.Supply: 240V Ac,Ac Voltage Transducer (Pd1-51135) Input: 0-137.5 Vac, Range: 0-500 Kvac Ptr: 400Kv/ 3/110/ 3 Output 1: 4-20Madc At 500 Ohm Output 2: 4-20Madc At 500 Ohm Accuracy: +/-0.2 Percent Aux.Supply: 240V Ac,Ac Voltage Transducer (Pd1-51135) Input: 0-150 Vac, Range: 0-150 Vac Output 1: 4-20Madc At 500 Ohm Output 2: 4-20Madc At 500 Ohm Accuracy: +/-0.5 Percent Aux.Supply: 240V Ac

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 09-01-2025 PROCUREMENT OF AE MAKE TRANSDUCERS 17-01-2025
2 17-01-2025 PROCUREMENT OF AE MAKE TRANSDUCERS 25-01-2025

Key Value

Document Fees
Refer document
EMD
INR 565.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB