Providing Various Types Of Motors Pumps Etc Accessories And Repair To Various Motors And Pumps Etc Under Water Supply Department For M C Ahmedpur- 1 1 to 3 HP For FILTER Pump HouseFloculator Bridge3 Phase INDUCTION MOTORS(Kirloskar Manufctured) 2 5 HP For FILTER Pump HouseFloculator Bridge3 Phase INDUCTION MOTORS(Kirloskar Manufctured) 3 7.5 HP For FILTER Pump HouseFloculator Bridge3 Phase INDUCTION MOTORS(Kirloskar Manufctured) 4 1 HP new submersible single phase 5 1.5 HP new submersible single phase 6 2 HP new submersible single phase 7 3 HP new submersible single phase 8 3 HpThree Phase(including all required material for erection like wire, clamps with labour rate) 9 5 HP three Phase(including all required material for erection like wire, clamps with labour rate) 10 7.5 HPThree Phase(including all required material for erection like wire, clamps with labour rate) 11 10 HPThree Phase(including all required material for erection like wire, clamps with labour rate) 12 20 HP hree Phase(including all required material for erection like wire, clamps with labour rate) 13 40 HPThree Phase(including all required material for erection like wire, clamps with labour rate) 14 60 HPThree Phase(including all required material for erection like wire, clamps with labour rate) 15 100 HPThree Phase(including all required material for erection like wire, clamps with labour rate) 16 1 to 3 HP monoblock motor rewinding 17 5 HP monoblock motor rewinding 18 7.5 HP monoblock motor rewinding 19 Motor rewinding 0.5 HP to 3 HP( with labour charges ) V3 AND V4 Submersible pumps 20 Opening Dismantling, transporting & Fitting Charges 21 5to 7.5 HP Complete submersible pump & motor repair with, Requiredthurst Bearing, Motor Bushes, Pump Bushes, Pump Impeller, Housing NRV, pump IP, Motor base replacement V6 SUBMERSIBLE PUMPS 22 8 to 10 HPComplete submersible pump & motor repair with, Requiredthurst Bearing, Motor Bushes, Pump Bushes, Pump Impeller, Housing NRV, pump IP, Motor base replacement V6 SUBMERSIBLE PUMPS 23 20 HPComplete submersible pump & motor repair with, Requiredthurst Bearing, Motor Bushes, Pump Bushes, Pump Impeller, Housing NRV, pump IP, Motor base replacementV6 SUBMERSIBLE PUMPS 24 1 TO 5HP Opening Dismantling, transporting & Fitting Charges 25 5 To 10 HP Opening Dismantling, transporting & Fitting Charges 26 10 To 20 HP Opening Dismantling, transporting & Fitting Charges 27 30 to 35 HP Complete V8 submersible pump & motor repair with, Requiredthurst Bearing, Motor Bushes, Pump Bushes, Pump Impeller, Housing NRV, pump IP, Motor base replacement 28 40 HPComplete V8submersible pump & motor repair with, Requiredthurst Bearing, Motor Bushes, Pump Bushes, Pump Impeller, Housing NRV, pump IP, Motor base replacement 29 60 HPComplete V8 submersible pump & motor repair with, Requiredthurst Bearing, Motor Bushes, Pump Bushes, Pump Impeller, Housing NRV, pump IP, Motor base replacement 30 65 HPComplete V8 submersible pump & motor repair with, Requiredthurst Bearing, Motor Bushes, Pump Bushes, Pump Impeller, Housing NRV, pump IP, Motor base replacement 31 75 HPComplete V8 submersible pump & motor repair with, Requiredthurst Bearing, Motor Bushes, Pump Bushes, Pump Impeller, Housing NRV, pump IP, Motor base replacement 32 100 HPCompleteV8 submersible pump & motor repair with, Requiredthurst Bearing, Motor Bushes, Pump Bushes, Pump Impeller, Housing NRV, pump IP, Motor base replacement 33 30 HP Opening Dismantling, transporting & Fitting Charges 34 35 to 40 HP Opening Dismantling, transporting & Fitting Charges 35 60 to 75 HP Opening Dismantling, transporting & Fitting Charges 36 100 HP 37 Extension of Pipe at water source of pumps quote (30 HP & 40 HP & 60 HP& 65 Hp & 75HP & 100 HP) 38 100 HP V.T. Water Lubricated Pumps & Motors 39 VHS Motor rewinding 40 Motor Connection Plate 41 Motor thurst bearing 7320 42 Bottom bearing 6316 43 Complete removing & Erectioning of 100 HP VT Pump after repair 44 ATS Repairs 45 60 HP 46 65 HP 47 75 HP 48 100 HP 49 Transformer Oil 50 STARTER & PANEL ATS STARTER 51 starter wiring Checking 52 Contactor 315 Amps 53 Contactor 85 Amps 54 Contactor 115 Amps 55 Contactor 165 Amps 56 Contactor 200 Amps 57 Contactor 225 Amps 58 Relay Unit CT Operated for 100 HP 59 Delay on switch 60 Delay Off Switch 61 Supplying & erecting similar to L&T make timer for MK-1(For STAR/DELTA) motor starterupto 12.5 H.P.( with labour charges) 62 MPRD2 63 MCCB 400 Amps 64 MCCB 500 Amps 65 MCCB 600 Amps 66 VSS Selector switch 67 ASS Selector Switch 68 Supplying and erecting panel mounting type digitalammeter having Three and half digit LEDdisplay,external C.T. operated, calibrated for suitable tooperate on 500V 0to1000A AC supply with necessary PVCwire leads and lugs and mounting hardware on provided panelcomplete with calibration certificate from manufacturer. 69 Supplying and erecting panel mounting type digitalvoltmeter having Three and half digit LEDdisplay,calibrated for 0 to 750V AC suitable to operate on500V AC supply with necessary PVC wire leads and lugsand mounting hardware on provided panel complete withcalibration certificate from manufacturer. 70 Supplying and erecting modular type indicator lampISI markapproved make duly erected on provided plate and box withwiring connections complete 71 Simple Starter (Manufactured By L&T)-5Hp to 35 Hp 72 1 HP DOL starter 73 1.5 HP DOL starter 74 2 Hp DOL starter 75 3 HP DOL starter 76 5 HP DOL starter 77 7.5 HP DOL starter 78 10 HP DOL starter 79 20 HP Star Delta 80 25 TO 35 HP Star Delta 81 Starter Wiring Checking 82 Riley Kit(new) 83 Timer (new) 84 Blade Kit (new) 85 Magnet Coil (new) 86 Contacter (new) 87 Starter repairing 88 Lugje Aluminium 89 10 - 25 SQ MM 90 50 SQ MM 91 70Sq.mm to 95 Sq.mm. 92 120 Sq.mm. 93 150 Sq.mm. 94 185 Sq.mm. 95 240 Sq.mm. 96 300 Sq.mm. 97 Bearing 98 Bearing 7316 99 Bearing 6211 100 Bearing 7220 101 Bearing 6316 102 Bearing 6313 103 Bearing 6312 104 Bearing 6207 105 Bearing 7322 106 Bearing 6309 107 Bearing 6306 108 Bearing 6209 109 Bearing 6204 110 Bearing 6305 111 Bearing 32206 112 Bearing 32208 113 Bearing 6307 114 Bearing 6308 115 KitKat 116 16V AMP 117 32 AMP 118 63 Amps 119 100Amps 120 200Amps 121 300Amps 122 Main Switch 123 63 Amps(H.C.TYPE)(with erection) 124 100Amps(H.C.TYPE)(with erection) 125 200Amps(H.C.TYPE)(with erection) 126 400Amps(HRC TYPE FUSE)(with erection) 127 Cabling & Accessories 128 3.5 Core 120 Sq.mm. Armard Cable 129 3.5 Core 95 Sq.mm. Armard Cable 130 3.5 Core 50 Sq.mm. Armard Cable 131 3.5 Core 35 Sq.mm. Armard Cable 132 19/16 Copper Flexible Wire 133 1.0 Core 25 Sq.mm. Copper Cable 134 3 Core 2.5 Sq.mm. Copper Cable 135 3 Core 4 Sq.mm. Copper Cable 136 3 Core 6 Sq.mm. Copper Cable 137 3 Core 10 Sq.mm. Copper Cable 138 3 Core 16 Sq.mm. Copper Cable 139 3 Core 25 Sq.mm. Copper Cable 140 Supplying & erecting flat flexible 3 core 10 sq.mmPVC sheathed submersible type copper cable suitably clamped at fixed intervals with coloum pipe assembly complete. 141 Supplying & erecting flat flexible 3 core 16 sq.mmPVC sheathed submersible type copper cable suitably clamped at fixed intervals with coloum pipe assembly complete. 142 1.25 inch HDPE 143 1.5 Inch HDPE 144 2 Inch HDPE 145 2.5 inch GI C Class 146 3 to 3.125 nch GI C Class 147 4 inch GI C Class 148 15 mm dia bent 149 25 mm dia bent 150 40 mm dia bent 151 50 mm dia bent 152 65 mm dia bent 153 75 mm dia bent 154 100 mm dia bent 155 15 mm dia Tee 156 25 mm dia Tee 157 40 mm dia Tee 158 50 mm dia Tee 159 65 mm dia Tee 160 75 mm dia Tee 161 100 mm dia Tee 162 150 mm dia Tee 163 15 mm dia nipple 164 25 mm dia nipple 165 40 mm dia nipple 166 50 mm dia nipple 167 65 mm dia nipple 168 75 mm dia nipple 169 100 mm dia nipple 170 150 mm dia nipple 171 15 mm dia union 172 25 mm dia union 173 40 mm dia union 174 50 mm dia union 175 15 mm dia elbow 176 25 mm dia elbow 177 40 mm dia elbow 178 50 mm dia elbow 179 Supplying & erectingautomatic control panel for 1 Ph, 230 volt, A.c. Submersible/centrifugal pump set upto 2 HPconsisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof encloser with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase inbalence etc ( Similar to LT model no.MR G2) 180 Supplying & erectingautomatic control panel for 3 Ph, 415volt, A.c. Submersible/centrifugal pump set upto 7.5HPconsisting of DOL starter having relay range 9-14AMP,S.P.P., Combined ammeter/voltmeter, phase indicatinglamp enclosed in CRCA powder coated Vibration proofencloser with IP 54 protection. Control Panel should offersingle phasing, phase reversal, phase inbalence etc ( Similar toLT model no.MU G6/ CAT NO. SS97756 ) 181 Supplying & erectingautomatic control panel for 3 Ph, 415volt, A.c. Submersible/centrifugal pump set upto 7.5- 10HP consisting of DOL starter having relay range 13-21AMP,S.P.P., Combined ammeter/voltmeter, phase indicatinglamp enclosed in CRCA powder coated Vibration proofencloser with IP 54 protection. Control Panel should offersingle phasing, phase reversal, phase inbalence etc ( Similar toLT model no.MU G10 / CAT NO. SS95983 ) 182 Supplying & erecting automatic control panel for 3 Ph, 415volt, A.c. Submersible/centrifugal pump set upto 7.5- 10HP consisting of DOL starter having relay range 28-42AMP,S.P.P., Combined ammeter/voltmeter, phase indicatinglamp enclosed in CRCA powder coated Vibration proofencloser with IP 54 protection. Control Panel should offersingle phasing, phase reversal, phase inbalence etc ( Similar toLT model no.MU G10 H / CAT NO. SS95974 ) 183 Supplying & erecting automatic control panel for 3 Ph, 415volt, A.c. Submersible/centrifugal pump set upto 20 HPconsisting of Star Delta starter having relay range 13-21Amp,S.P.P., Combined ammeter/ voltmeter, phaseindicating lamp enclosed in CRCA powder coated Vibrationproof encloser with IP 54 protection. Control Panel shouldoffer single phasing, phase reversal, phase inbalence etc( Similar to LT model no.MU G20 / CAT NO. SS 95984 ) 184 Supplying & erecting automatic control panel for 3 Ph, 415volt, A.c.Submersible/centrifugal pump set upto 20HPconsisting of Star Delta starter having relay range 28-42Amp, S.P.P., Combined ammeter/ voltmeter, phase indicatinglamp enclosed in CRCA powder coated Vibration proofencloser with IP 54 protection. Control Panel should offersingle phasing, phase reversal, phase inbalence etc ( Similar toLT model no.MU G20H / CAT NO. SS 95975 ) 185 Supplying & erectingautomatic control panel for 3 Ph, 415volt, A.c.Submersible/ centrifugal pump set upto 30HPconsisting of Star Delta starter having relay range 30-50Amp, S.P.P., Combined ammeter/ voltmeter, phase indicatinglamp enclosed in CRCA powder coated Vibration proofencloser with IP 54 protection. Control Panel should offersingle phasing, phase reversal, phase inbalence etc ( Similar toLT model no.MU G30 / CAT NO. CS 96008 ) 186 Supplying & erecting automatic control panel for 3 Ph, 415volt, A.c.Submersible/ centrifugal pump set upto 10 HPconsisting of Star Delta starter having relay range 6-10 Amp,S.P.P., Combined ammeter/ voltmeter, phase indicating lampenclosed in CRCA powder coated Vibration proof encloserwith IP 54 protection. Control Panel should offer singlephasing, phase reversal, phase inbalence etc ( Similar to LTmodel no.MU G15/ CAT NO. CS94091SOVO ) 187 300 hp pump total repairwith transportation 188 300 hp pump bearingwith transportation 189 300 hp new ats with transportation 190 300ats repair with transportation 191 100 hp pump rewinding all repair 192 100 hp bearingwith transportation 193 100 hp ats repairwith transportation 194 100 hp new atswith transportation 195 100 hp shaft with transportation 196 300 hp shaftwith transportation 197 350kva transformer repairwith transportation 198 750kva transformer repairwith transportation 199 4 pole 63 amp mcb 200 pump timer 100 hp 201 pump timer 300 hp 202 indicator light 203 capacitor timer 140 amp 204 300 hp rewingingwith transportation 205 100 hp rewindingwith transportation 206 100 hp total pump repair with transportation 207 C.T. meter 315 Amps 208 Polypropylene Capacitor 1 to 25 KVAR (400 v) 209 metalized Polypropylene Capacitor 1 to 25 KVAR (400 v) 210 mada pump[ repair 211 capacitor 25kvar 212 contactor240 amp 213 contactor 400 amp 214 contactor650 amp 215 mcb 630 amp 216 metalized Polypropylene Capacitor 1 to 25 KVAR (400 v) 217 100 hp Motar Contact Kit 218 Bore Cap 219 Supply of Clamp set pair 220 1 inch 221 1.5 inch 222 2 inch 223 borewell /well testing charges 224 clean up of well 225 Casing Stand