Tender For Augmentation And Expansion Of C. Room With Other Misc. Civil Works At 33 Kv S/S Under Aen A-I Newai., 1 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 3: 6 or richer mix.(B-14.2.1) 2 Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:In cement mortar.(B-14.9.2) 3 Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead:(A)Of area 3 square meter and below.(B-14.12.1) 4 (B)Of area exceeding 3 square meter..(B-14.12.2) 5 Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.(B-14.25) 6 Dismantlingroofingincludingridges,hips,valleysandraftersetc.andstackingthewithin 50 meter lead of:.G.I. Sheet.(B-14.28.1) 7 (B) Asbestos Sheet.(B-14.28.2) 8 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead.(B-14.18) 9 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar.(B-14.7.3) 10 Dismantlingprecastconcreteorstoneslabsinwallpartitionsetc.includingstackingwithin50 meter lead:Thickness 40mm up to 75mm(B-14.40.2) 11 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.(B-14.55) 12 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches by sandla/loi. (only for colour changing )..(B-12.35.7) 13 Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :- (I)Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried. (II) Applying Epoxy primer on the exposed steel bars.(III)Applying Epoxy hardener and resin mix (as per manufectureds specification) on concrete and steel bars with brush.(IV) Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.(V) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.(VI) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. .(B-13.29) 14 Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:For thickness of tiles 10mm to 25mm.(B-14.23.1) 15 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils(B-1.8) 16 P & L in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering -All work up to plinth level. (A) 1:4:8 ( 1 cement : 4 coarse sand: 8 graded stone aggregate 40mm nominal size.) (B/3.1.6) 17 (B) M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size).(B/3.1.1) 18 RR stone masonry for with hard stone in foundation and plinth in CSM above 30cm thick wall in CM 1:6 (1cement :6 Sand). (B/6.1.6) 19 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand.(B-1.27(b)). 20 RR dry stone kharanja under floor. (B-11.26) 21 Renewing glass panes, with putty and nails wherever necessary. Float glass panes of thickness 5mm. (B- 13.4.2) 22 S & F stone lintels / bed plates of approvedquarry rough dressed in cement mortar 1:4 : Up to 15 cm thick. (B-6.18.1) 23 P & L in position specified grade of CC for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1: 3 (1cement :3 coarse sand) and making good the joints & cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15̊ landings, balconies, shelves, chjjas, lintels, bands, plain windows sills, staircases and spiral staircases. M20 grade Nominal Mix / Design Mix. (B-4.3) 24 C & S with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for superstructure up to floors, roofs, landings staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintl, beam etc.(B-4.10.2) 25 P & F reinforcement for R.C.C. work including straightening, cutting, banding, placing in position and binding (including cost of binding wire) all complete up to floor five level. Hot rolled deformed bars (IS:1139). (B-4.13.2) 26 Halfbrick masonry in superstructure, above plinth level upto floor V level using bricks of designation 75. Cement mortar 1:6 (1cement: 6 coarse sand). (B-5.8.3) 27 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :: Cement mortar 1 : 6 (1 cement : 6 coarse sand)(B-5.2.2) 28 Grading for roof water proofing treatment with CementConcrete1:2 :4(1cement:2coarsesand:4gradedstoneaggregate20mmnominalsize) with water proof compound as per manufactures specification. (B-10/10.17.1) 29 P & F precast cement concrete coping 1:2:4 mix 50 mm thick copmlete as per specification : (B-3.8) 30 Providing Gola 75×75 mm in cement concrete 1:2:4(1Cement:2coarse sand: 4 stone aggregate 10mm and down gauge) including finishing with cement morter 1:3 as per standard design.(B-10/10.22) 31 P & Fsteel glazed doors windows andventilator shutters of standerdrollde steel section joints mitred andwelded with steel lugs 13x3mm, 10 cm, long embeded in cement concrete block 15X10X10CM of 1:3:6 (1 cement : 3 coarse sand:6 gradedstoneaggregate20mm nominal size) of with wooden plugs and screws of rawl plugs and screws with fixing clips or with bolts and nyts as required includingprovidingand fixing of plain glass panes 4mm thickwith cooper glazing clips and special metal sash puttyof approvedmake of metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handlwds peg stay etc. as required:(A) Window side hung /Ventilators top or centre hung (openable) (B-9.19.3) 32 Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20×3mm with suitable screw at not exceeding 150 mm distance.(B-9.26) 33 Providing and fixing square bars or other flat welded to windows, ventilators etc. (B-9.27) 34 P & F T-iron frames for doors, windows & ventilators of mild steel Tee- section, joints mitred & welded with 15 X 3 mm lugs 10cm long embeded in CC blocks 15X10X10 cm of 1:3:6 (1cement :3 coarse sand: graded stone aggregate 20mm nominal size) or with woodenpluges & scews of plugs & scews or with fixing clips or with bolts & nuts as require including fixing of necessary butt hinges & screws & applying a priming coat of approved steel primer. (B-9.5) 35 S & F in walls machine cut and polished stone shelves,tands and in 1:3 with machine cut edges: (A) Kota stone minimum 30 mm thick (B-6.17.3) 36 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 market using phenol formal dehysresin in glue both side with approved steel bildding complete as pr annexure A,30 mm thick commercial vernier both side. (B-8.13.2.1) 37 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13.. (B-8.14) 38 Applying priming coat:With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. (B-12.45.1) 39 P & F M.S. Sheet 1mm thick single leaf door shutter in angle iron frame 35 x35x5 mm suitablly diagonally braced with 25 x 3 mm flat iron above & below lock rail of size 50x5 mm beading extra including all fittings, as per direction of Engg. Incharge but excluding cost of chowkhats: including two coat of anti-corrosive red oxide primer paint. (B-9.17) 40 Add Extra for Double leaf door shutter (B-9.17.1) 41 P &F 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shadesglazed tiles conforming to IS: 13753 & IS:15622 of size 200mm x 300 mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls & pillars). (B-7.12) 42 P & L 1st quality MAT finished ceremic tile size 300 x 300 mm confirming to IS: 13755 and IS:15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement mortar bed).(B-7.13) 43 Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1: 4 (1 cement : 4 coarse sand) (A) For area of each slab upto 2001 to 5000 Sq.Cm. (B-11.18.2) 44 Kota stone slabs 25mm thick in riser of steps, Skirting, dado and pillars laid on 12mm (Average) thick cement mortar 1:3 (1cement:3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete: for area of each slab from 2001 to 5000 Sq.Cm. (B-11.19.2) 45 Providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80x25 mmx1.25 mm thick with 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer In Charge. (B-9.39) 46 Add extra for Square or Rectangular Pillars in Superstructre brick work up to five storey:Upto 45 cm length and all sides are free(B-5.3.1) 47 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix (B-4.2) 48 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc.(B-4.10.3) 49 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement :3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer in- charge). (B-11.29) 50 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joints etc. complete fine finished. (A) 20mm thick. (B-12.3.2) 51 (B) 12 mm thick. (B-12.3.3) 52 (C) 25 mm thick. (B-12.3.1) 53 6mm cement plaster to ceiling of mix 1:3 (1cement:3 fine sand).(B-12.5) 54 Finishing walls with acrylic smooth exterior paint of required shade including all scaffolding. New work (two or more coats applied @ 1.67 ltr/10sqm over & including base coat of water proofing cement paint applied @ 2.20 Kg/10sqm). (B-12.42) 55 Painting with synthetic enamel paint of approved brand and manufacture to give and even shade : (A) Two or more coats on new work. (B-12.46.1) 56 (B)One or more coats on old work. (B-12.46.2) 57 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete. New Plastered Surface. (three or more coats) (B-12.22.1). 58 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: (A) Newwork(twoormorecoats) over and including scrapping and priming coat with cement primer. (B-12.37.1) 59 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mm and 10 mm thick as per approved design. (B-12.20) 60 Making grooves as per design in plaster 10mm to 20mm wide. (B-12.19) 61 Providing and laying ofpaver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement)M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc. Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004Add extra over item No. 11.38, A to C if reflective paver block, manufactured with wet cast vibration system in two layers is used.(B-11.38.3.(A)+11.39) 62 P&F WVC wash basin (Ist quality IS: 2556 mark) of approved make with C.I. brackets duly painted, 1 No.15mm C.P. Pillar cock (IS: 8934 mark) & 32mm C.P. brass waste coupling of approved make, 25mm G.I. waste pipe complete including cutting and making good the walls,580mm X 450mm. (S-1.36.4) 63 P&F Towel rail or Ring of approved quality/make C.P.brass towel rail with brackets 450x20mm. (S-1.47.3) 64 P&F PVC storage tank (IS: 12701 marked including the BIS license No.) of approved make with cover,25 mm dia IM long over flowing & 25 cm. Long wash out pipe with plug & socket, including making connection etc. Complete of approved deisgn : 500 liters capacity. (S-2.26.3) 65 P&F Looking Mirrors with P.V.C. frame of approved (atul/Modi guard.Sanit Gobin or equivalent) size 500x400mm. (S-1/1.45.1) 66 P & F Chlorinated Polyvinyl Chloride (CPVC) pipe, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete as per direction of Engineer in Charge. ( Internal work Exposed on wall). (A) 15mm nominal outer dia pipes. (S-2.37.1) 67 (B) 25mm nominal outer dia pipes. (S-2.37.3) 68 P & F Chlorinated Polyvinyl Chloride (CPVC) pipe, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. ( External work). (A) 15mm nominal outer dia pipes. (S-2.39.1) 69 (B) 25mm nominal outer dia pipes. (S-2.39.3) 70 Making connection of GI distribution branch with GI main including all fitting : Upto 25mm dia.(S-2/2.3.1) 71 P&F bib cock (IS : 8931 mark), Superior quality of approved make.(A) CP Brass bib cock 15mm nominal bore. (S-2.7.3) 72 P&F ball cock (IS : 1703 mark) with rod& PVC ball complete: Brass wt. Not less than 300gm 15mm. (S-2.11.1) 73 P & F Full way valve (IS : 778 Mark) or wheel valve of approved make. (A) Gun-metal 15mm nominal bore. (S/2.15.1) 74 (B) Gun-metal 25mm nominal bore. (S/2.15.3) 75 P&F inlet connection (Angle velves) superior quility of approved make for washbasin Gyser etc. CP intel connection 15 mm Brass (IS: 8931 marked). (S-2.12.1) 76 P & F 15 mm. Dia Connection Pipe of approved quality/make :PVC pipe withC.P. Brass nuts upto length, 300mm. (S-2.13.1) 77 Construction of manhole in all typeof soil inner size 90X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm thick CC 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M -15 grade C.C fooring, making, channels, 80mm thick stone slab covering with 40mm thick M- 15 grade C.C flooring, Cement cocer with frame of 450mm dia, earthork etc. as per design including disposal of surplus earth within 50 mtr. lead. Depth up to 0.5 m.(S-3.19.1) 78 Providing and laying cement concrete 1:5:10( stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150mm thick bed concrete ( Width W= Dia of pipe in Cm + 30Cm.) conrete width to be reduced from width W at centre of pipe to 0 at top of pipe(Excluding cost of pipe).100 mm diameter S.W. Pipe.(S-3.3.1) 79 Construction of chamberin all typeof soli with300 mm. thick masonry in CM 1:6 m 10Cmthick C.C1:5:10 infoundation, 20mm thick inside plaster in CM 1:6, finshed with floatinf neat cenent50 mm thickM-15 grade C.C flooring, Ferro work etc. complete as perdesing includingdisposal of surplus earth within a lead of50 mtr. Inside size 300 X 300 mm depth upto 0.5 M Cement cover with frame.(S-3.21.1) 80 P&F rigid PVC pipe (IS:4985 mark) class-II (4kg/Cm2approved quality/ make including jointing the pipe with solvent cement rubber ring and lubricant (A) 75 mm dia (S-3.16.2) 81 (B) 110mm dia (S-3.16.3) 82 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:(A) Bend 87.5. 110mmdia(S/3.17.9/(II)) 83 (B) Bend 45. 110mmdia(S/3.17.8/(II)) 84 (C )Coupler (Soket) 110mmdia. (S/3.17.1/(II)) 85 (D)Pipe clip.110mm dia.(S/3.17.15/(ii)) 86 (E)VENT Cowel .110mm dia.(S/3.17.12/(ii)) 87 (F )PLAIN TEE 110mmdia. (S/3.17.3/(ii)) 88 Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size :(A) 15mm dia nominal bore (S-2.32.1) 89 (B) 25mm dia nominal bore (S-2.32.3) 90 P & F sand cast Floor Trap (Nahni) of (IS : 1729 mark) of approved quality / make with socket down or hinged grating including good the floor.Size 100x100mm. (S-3.12.1) 91 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR (A) Short point (upto 3 mtr)(E-1.1) 92 (B) Medium point (up to 6 mtr) (E-1.2) 93 (C) Long point (uo to 10mtr) (E-1.3) 94 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. On Board (E-1.3.1) 95 Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR(E-7.36) 96 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR (A) 2×2.5 sqmm+1x1.5 sq.mm (E-4.1.7) 97 (B) 2×4.0 sqmm+ 1x2.5 sq.mm( E-4.1.14) 98 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .8 SWG copper Wire 8 SWG copper Wire(E-14.6.5) 99 Pipe Earthingas per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(E-14.1) 100 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR.1170mm (+/-10%) LED batten with min. lumen output 2200 lm (E-17.1.1) 101 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR. 32 mm Dia.(E-18.18.3) 102 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR(E-5.9) 103 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating (E-6.1.1.2) 104 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR Double pole isolator30 A / 40 A rating(E6.2.1.1) 105 Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted complete with din rail making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRSuitable for Six / Eight module for MCB/ RCCB(E-6.9.2) 106 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR (A) 6.0 Sq. mm X 2 core (E-11.2.2.1) 107 (B)4.0 Sq. mm X 2 core (E-11.2.1.1) 108 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 0% lumen maintened , CRI >70 and CCT 5700K +355K. Surgeprotection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/ Name engraved/Embossing on die cast housing to allow traceability/ authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/ accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer. Annexure A attached with this BSR. (A) LED Street Light fixture with Minimum lumen output 3700 lm(E-18.12.2) 109 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Capacity 4.5 Kg.(E-24.66.2) 110 Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulbin existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70,minimum life time of minimum25000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR.9 Watt(E-17.9.3) 111 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR.20mm.(E-1.4.1) 112 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 )(E-15.7.2) 113 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating(E-7.29.1) 114 Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge of welding meachine and TP etc complete.(B-13.23) 115 Renewing glass panes,with putty and nails wherever necessary.Float glass panes of thickness 4 mm (B-13.4.1) 116 Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc. (B-13.24) 117 Repair to damaged cement plaster of stone chajja with CM 1 : 3 of required thickness on top &bottom as per existing pattern and making patta etc complete up to three floor level as per direction of Engineer in charge including all necessary scoffolding etc (B-13.31) 118 Supply and fixing of Cement Bonded Particle Board (as per 14276) wall paneling using 10 MM thick Cement Board with frame work made of GI stud section of size 48mm x 35mm x 0.55mm thick placed at every 610 mm C/C intervals vertically and at 1200mm internals horizontally fixed to the wall by means of self expansion screws and caps. Cement Board panel is to be fixed to frame by means of self taping screws placed at every 300 mm intervals leaving 3mm gap between two panels. The cost inclusive of one coat of Altek primer and two coats of Altek smooth finish and cost & conveyance of all materials, labor charges etc. complete as per the direction of Engineer in charge.. (B-17.9) 119 Providing & fixing calcium silicate perforated ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge of thickness of tiles as mentioned below:-8 mm thick(B-10.33.2) 120 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Surface Moutning.Minimum lumen output 4200 lm (E-17.4.2.3) 121 Labour Charges for removing WVC pan:(A) European W.C.(S/1.58.2) 122 (B)Flushing cistern(S/1.58.3) 123 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor (S/1.3) 124 P & F water closet Seat Covers with brass hinges complete :Solid PVC (IS 2548 marked) grade-I White for EWC.(S/1.7.2) 125 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: PVC withPVCbend and superior internal fittings as per IS : 7231 . (S/1.20.3) 126 Removing & Re fixing of P.V.C. Cistern fittings (Syphon, Ball cock & Handle Set) complete as per direction of Enginner-in-Charge (S/1.67) 127 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. Flat Back (large) or half stall size 610x400x80mm.. (S/1.14.2) 128 Providing and Fixing Chiken wire mesh at the joint of masonry members/ R.C.C. Memberswith Nails complete in all respect. (B-17.35) 129 Supplying and fixing Rollor Blinds of good quality and approved make made out of Imported fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction and sample approved by engineer-in-charge. (B-16.58) 130 Making the opening inmasonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground. For door/windows/clerestory windows (B-13.3)